Campbell Hausfeld GN301502AC, GN30c502AC User Manual

0 (0)
entangled in moving components, causing equipment damage and or personal injury.
9. Keep all persons away from parts that move or become hot during operation.
10. Be sure all powered devices are shut off prior to connecting them to the generator.
11. Keep the generator clean and well maintained at all times.
Never operate this generator in an explosive atmosphere or poorly ventilated area.
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.
IN951300AV 2/00
Operating Instructions Models GN301502AC and GN30C502AC
Generators
These generators are powered by air­cooled four cycle engines and designed to run at maximum RPM and give a continuous wattage as rated.
When unpacking, inspect carefully for any damage that may have occurred during transit. Make sure any loose fittings, bolts, etc., are tightened before putting unit into service.
1. Before starting or servicing any generator, read and understand all instructions. Failure to follow safety precautions or instructions can cause equipment damage and/or serious personal injury. Engine instructions for these units are contained in a separate manual. Retain all manuals for future reference.
2. Never use this generator for any application other than that specified by the manufacturer. Never operate this generator under conditions not approved by the manufacturer. Never attempt to modify this generator to perform in any manner not intended by the manufacturer.
3. For maintenance and repairs, use only products and parts recommended by the manufacturer.
4. Be sure that the generator is properly grounded to an external ground path prior to operation. Refer to the section entitled
“Grounding Instructions” for proper grounding procedures.
5. Be sure that the generator is operated only by persons who have read and understand these instructions.
6. Be sure that the generator is placed on a flat level surface prior to and during operation. The generator must not slide or shift during operation.
7. Keep all persons away from the generator during operation.
8. Do not allow persons wearing loose clothing or jewelry to start or operate the generator. Loose clothing or jewelry may become
Fig. 1 - Assembled Units GN301502AC and GN30C502AC
For parts, product & service information
visit www.campbellhausfeld.com
or call 1-800-803-1436
© 2000 Campbell Hausfeld / Scott Fetzer
Description
Unpacking
General Safety
BUILT TO LAST
TM
MANUAL
!
WARNING
PRE-OPERATION
1. Check engine oil level every time you start your generator. Refer to
the Engine Manual for SAE, API and fill quantity specifications.
2. Use of a Ground Fault Circuit Interrupter (GFCI) is strongly recommended. Ground Fault Circuit Interrupters can significantly reduce the possibility of injury if an electrical short occurs.
A Ground Fault
Circuit Interrupter may not be effective if used on a generator that is not grounded!
3. When installing a GFCI, be sure to
follow all national and local regulations, or call a licensed or certified electrical technician.
GROUNDING
1. Use the ground terminal and wing
nut on the generator frame to connect the unit to a suitable ground source. Securely fasten the end terminal of the ground wire to the ground terminal on the generator frame. Tighten the washer and wing nut on top of the ground wire end terminal.
2. The ground wire should be made of
#8 gauge wire. Do not use wire with
a higher gauge number. Higher gauge numbers indicate thinner wire, which may not provide an adequate ground path.
3. The other end of the ground wire must be securely fastened to an approved ground source.
The following are ground sources approved by the National Electric Code. Other ground sources may be acceptable. Refer to the National Electric Code and local regulations for further ground source information. If not sure of regulations or procedures, obtain assistance from a qualified (licensed or certified) electrical technician.
a. An underground water pipe at
least ten feet in length.
b. A non-corrosive underground
pipe at least eight feet in length and 3/4 inch diameter.
c. A steel or iron underground rod
at least eight feet in length and 5/8 inch diameter.
d. A non-ferrous rod at least eight
feet in length, 1/2 inch in diameter, and approved for grounding purposes.
Any rod or pipe used for grounding must be driven to eight feet deep or buried in the deepest possible trench.
2
Operating Instructions
12. Be sure that all tools and appliances are in good repair and are properly grounded. Use devices that have three prong power cords. If an extension cord is used, be sure that it has three prongs for proper grounding.
Do not operate this generator on wet
surfaces or in the rain.
13. Never operate the generator with damaged, broken or missing parts, or with any guarding components removed.
Shut off the
generator engine and disconnect the spark plug wire before performing any service or maintenance to the unit.
14. Use only unleaded fuel. Do not refill
the fuel tank while the engine is running. Use precautions to prevent fuel spillage during refills. Be sure the fuel tank cap is securely in place before starting the engine. Allow engine to cool for at least two minutes before refueling.
Never mix oil with
gasoline for this engine. Oil is used for engine lubrication purposes only.
NO TOOLS REQUIRED FOR ASSEMBLY
NEVER OPERATE YOUR GENERATOR UNDER THESE CONDITIONS:
1. Rain or inclement weather
2. Excessive vibration
3. Sparking
4. Engine misfire
5. Electric output loss
6. Changing or fluctuating engine speed
7. Overheating in connected equipment
8. Damaged receptacles
9. Damaged, broken or missing parts
10. Guarding components removed
ALWAYS OPERATE YOUR GENERATOR UNDER THESE CONDITIONS:
1. Read and understand these instructions
2. Clear of all persons
3. Properly grounded (generator)
4. Properly grounded (tools, appliances, etc.)
5. Flat level surfaces
6. Well ventilated areas
www.campbellhausfeld.com
Fig. 2 - Handle Assembly
General Safety (Continued)
Assembly
Operation
!
WARNING
!
DANGER
!
CAUTION
!
WARNING
3
Models GN301502AC and GN30C502AC
STARTING
1. Check oil level and fuel.
2. Remove all electrical loads from the generator.
3. Set the switch to the ON position.
4. Move the choke/run switch to the choke position.
5. Pull the starter rope with a brisk smooth motion.
6. Move the choke/run switch to the run position.
7. After each start up, allow engine to run 2-3 minutes with no load.
Engine speed is
preset to provide proper output voltage. Never attempt to modify or adjust engine speed or output voltage.
ENGINE BREAK-IN
After initial start-up, the engine should be broken in according to the manufacturer’s instructions. Refer to the engine manual for the proper break-in procedure.
GENERATOR SHUT OFF
1. Remove all electrical load devices
from the generator.
2. Allow the engine to run for 2-3
minutes with no electrical loads.
3. Set the switch to the OFF position.
This will stall the engine.
4. Verify that the generator has completely stopped.
5. Allow the unit to cool before installing any covers.
LOAD DEVICES
1. The 120 volt receptacles are rated for 15 amps.
2. Total combined load through any combination of receptacles must not exceed the rated load limits of the generator.
NOTE: Power draw can be calculated by multiplying volts and amps. The resulting number is wattage.
Never exceed the posted maximum wattage for the generator or any individual receptacle. Refer to owner's
manuals and product tags to determine the wattage of electrical load devices.
Long power cords and extension cords draw additional power. Keep cords at minimum possible length.
Precautions must be taken to prevent electrical back feeding into utility systems. This requires isolation of the electrical system. To isolate the electrical system, perform the following procedures:
1. Turn off the main electrical system switch prior to connecting the generator.
2. In accordance with national and local standards, a double throw transfer switch must be installed in the system.
Always shut off
main power prior to temporary connection of the generator to a building electrical system.
Installation of the
generator as a backup electrical source must be performed by a qualified (licensed or certified) electrical technician.
2.5 300 600 1000 600 375 250 5 600 1200 500 300 200 125
7.5 900 1800 350 200 125 100
10 1200 2400 250 150 100 50 15 1800 3600 150 100 65 20 2400 4800 175 125 75 50 25 3000 6000 150 100 60 30 3600 7200 125 65 40 4800 9600 90
Amps Watts Watts #8 #10 #12 #14 #16
120 V 240 V Wire Wire Wire Wire Wire
EXTENSION CORDS
MAXIMUM RECOMMENDED LENGTHS (IN FEET)
Operation (Continued)
www.campbellhausfeld.com
Air conditioner 2000-3000 Automatic washer 150-1500 Brooder 100+ Clothes dryer 5000-10,000 Coffee maker 400-700 Electric drill (small) 225-1000 Electric drill (large) 500-1000 Fan 40-200 Freezer 300-500 Hot plate 330-1100 Iron 500-1500 Light bulb As Rated
Load Device Watts Load Device Watts
Radio 50-200 Refrigerator 190-2000 Skillet 1200 Space heater 600-4800 Sump pump 400-3000 Television 200-500 Toaster 900-1700 Vacuum cleaner 200-300 Water pump 1000-3000 Water heater 1000-5000 Small hand saw 1000-2000 Large hand saw 1500-2500
ESTIMATED POWER USAGE (WATTS)
Installation for Stand-by Use
!
CAUTION
!
WARNING
!
WARNING
4
Operating Instructions
Fig. 3 - Wiring Diagram for GN301502AC and GN30C502AC
Rotor
Stator
Brushes Slip Rings
R
BK
Main Winding 120V
Main Winding 120V
Excitation Winding
R
Y
W
BK
G
BL
BL
R
BK
BK
R
AC
AC
G
Circuit Breaker
Circuit Breaker
Bridge Rectifier 200V, 8A
Capacitor
120V Duplex NEMA 5-15R
G
BK
BK
W
R
www.campbellhausfeld.com
INFREQUENT USAGE
If the generator is used infrequently, starting difficulty may occur. To help prevent difficulty starting, the generator should be run for approximately 30 minutes per week.
STORAGE
If the generator is not to be used for extended periods of time, the following pre-storage procedures should be performed:
Maintenance
1. Make sure engine oil is filled to the proper level.
2. Drain all fuel from the tank, lines, and carburetor.
3. Remove the spark plug, and pour approximately one teaspoon of oil into the spark plug hole.
4. Pull the starter cord several times to spread the oil throughout the cylinder.
5. Slowly pull the starter cord, until resistance is felt. This indicates that
the piston is moving upward on the compression cycle, and the intake and exhaust valves are closed. (The piston pushes a small amount of air from the spark plug hole on compression).
Refer to the engine manual that accompanies this unit for instructions regarding maintenance of engine components.
5
Zero output from receptacles
Low output voltage with no load
6 Vac or above
Below 6 Vac
High output voltage with no load
Low output voltage under load
Erratic output voltage
Noisy operation
1. Engine speed is too slow
2. Open, shorted, or incorrect wiring
3. Faulty capacitor
4. Open/shorted rotor or stator windings
5. Open rectifier
1. Engine speed is too slow
2. Open rectifier
3. Faulty capacitor
4. Open/shorted rotor or stator windings
1. Generator head not magnetized
1. Faulty capacitor
2. Engine speed is too fast
1. Open rectifier
2. Engine speed too slow at full load
3. Excessive load applied
1. Surging engine
2. Dirty, corroded, or loose wiring connection
3. Unbalanced load applied
1. Loose generator or engine bolt
2. Short circuit in generator field or load
3. Faulty bearing
1. Adjust engine speed
2. Referring to the wiring diagram, clean
and reconnect all wiring
3. Replace capacitor
4. Test winding resistance, replace winding
if necessary
5. Test rectifier, replace if necessary
1. Adjust engine speed
2. Test rectifier, replace if necessary
3. Replace capacitor
4. Test winding resistance, replace winding
if necessary
1. Re-magnetize generator head
1. Replace capacitor
2. Adjust engine speed
1. Test rectifier, replace if necessary
2. Adjust engine speed
3. Reduce the applied load
1. Refer to engine manual
2. Referring to the wiring diagram, clean
and reconnect all wiring
3. Remove all loads, then apply each one individually to determine which one is causing erratic function
1. Tighten all mountings
2. Test winding resistance, replace field winding if necessary Test load devices for shorts. Replace defective load device.
3. Replace bearing
These diagnostic and repair procedures should be performed by an authorized service center.
Troubleshooting Chart
Symptom Possible Cause(s) Corrective Action
GN301502AC and GN30C502AC
www.campbellhausfeld.com
Operating Instructions
Limited Warranty
1. DURATION: From the date of purchase by the original purchaser as follows: Standard Duty - One Year, Serious Duty - Two Years, Extreme Duty - Three Years. Units used for rental, industrial or commercial purposes are warranted for 90 days from date of purchase.
2. WHO GIVES THIS WARRANTY (WARRANTOR): Campbell Hausfeld / Scott Fetzer Company, 100 Production Drive, Harrison, Ohio, 45030, Telephone: (800) 803-1436
3. WHO RECEIVES THIS WARRANTY (PURCHASER): The original purchaser (other than for purposes of resale) of the Campbell Hausfeld generator.
4. WHAT PRODUCTS ARE COVERED BY THIS WARRANTY: Any Campbell Hausfeld portable generator supplied or manufactured by Warrantor.
5. WHAT IS COVERED UNDER THIS WARRANTY: Substantial defects on material and workmanship which occur within the duration of the warranty period.
6. WHAT IS NOT COVERED UNDER THIS WARRANTY: A. Implied warranties, including those of merchantability and FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED FROM THE DATE OF
ORIGINAL PURCHASE AS STATED IN THE DURATION. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you.
B. ANY INCIDENTAL, INDIRECT, OR CONSEQUENTIAL LOSS, DAMAGE, OR EXPENSE THAT MAY RESULT FROM ANY DEFECT, FAILURE,
OR MALFUNCTION OF THE CAMPBELL HAUSFELD PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
C. Any failure that results from an accident, shipping damage, purchaser’s abuse, neglect or failure to operate products in accordance
with instructions provided in the owner’s manual(s) supplied with product. D. Pre-delivery service, i.e. assembly, oil or lubricants, and adjustment. E. Items or service that are normally required to maintain the product, i.e. lubricants and filters. F. Gasoline engine components are expressly excluded from coverage under this limited warranty. Such components should be
returned by the purchaser to the original manufacturer or to its authorized repair stations for service.
7. RESPONSIBILITIES OF WARRANTOR UNDER THIS WARRANTY: Repair or replace, at Warrantor’s option, generator or component(s) which have failed within duration of the warranty period.
8. RESPONSIBILITIES OF PURCHASER UNDER THIS WARRANTY: A. Provide dated proof of purchase and maintenance records. B. Deliver or ship the Campbell Hausfeld generator or component to the nearest Campbell Hausfeld Authorized Service Center. Freight
costs, if any, must be borne by the purchaser.
C. Use reasonable care in the operation and maintenance of the generator as described in the owner’s manual(s).
9. WHEN WARRANTOR WILL PERFORM REPAIR OR REPLACEMENT UNDER THIS WARRANTY: A. Repair or replacement will be scheduled and serviced according to the normal work flow at the servicing location, and depending
on the availability of replacement parts.
B. If the purchaser does not receive satisfactory results from the Authorized Service Center, the purchaser should contact Campbell
Hausfeld (see paragraph 2). Limited Warranty applies in the U.S. and Canada only and gives you specific legal rights. You may also have other rights which vary from State to State or country to country.
6
www.campbellhausfeld.com
7 Fr
S’il vous plaît lire et conserver ces instructions. Lire attentivement avant de monter, installer, utiliser ou de procéder à l’entretien du produit décrit. Se protéger ainsi que les autres en observant toutes les instructions de sécurité, sinon, il y a risque de blessure et/ou dégâts matériels! Conserver ces instructions comme référence.
IN951300AV 2/00
Instructions D’Utilisation Modèles GN301502AC et GN30C502AC
Génératrices
Fig. 1 - Modèles GN301502AC et GN30C502AC Montés
© 2000 Campbell Hausfeld / Scott Fetzer
Description
Ces génératrices sont actionnées par des moteurs à quatre temps, refroidis par l’air et sont conçues pour le fonctionnement aux tr/min maximum afin de fournir la puissance en watts classifiée.
Lors du déballage, l’examiner soigneusement pour rechercher toute trace de dommage susceptible de s’être produit en cours de transport. Serrer tous raccords, boulons, etc., avant d’utiliser le modèle.
1. Lire attentivement toutes les instructions avant le démarrage ou l’entretien d’une génératrice. Manque de suivre les précautions de sécurité ou les instructions peut résulter en dommage de l’équipement et/ou en blessures personnelles graves. Les instructions du moteur pour ces modèles sont dans un manuel séparé. Conserver tous les manuels comme référence.
2. Ne jamais utiliser cette génératrice pour une application qui n’est pas spécifiée par le fabricant. Ne jamais faire fonctionner cette génératrice sous des conditions qui ne sont pas approuvées par le fabricant. Ne jamais essayer de modifier cette génératrice afin qu’elle fonctionne de manière qui n’est pas approuvée par le fabricant.
3. Utiliser seulement les produits et les pièces de rechanges recommandés par
Déballage
Généralités sur la Sécurité
le fabricant pour l’entretien et la réparation.
4. S’assurer que la génératrice soit mise à la terre correctment à un trajet de mise à la terre extérieur avant de faire fonctionner le modèle. Se référer à la section “Instructions de Mise à la Terre” pour la méthode de mise à la terre correcte.
5. S’assurer que la génératrice soit utilisée par des personnes qui se sont familiarisées avec ces instructions.
6. S’assurer que la génératrice soit située sur une surface plate et nivelée avant et pendant son fonctionnement. La génératrice ne doit pas glisser ni se déplacer pendant le fonctionnement.
7. Garder toutes les personnes à l’écart de la génératrice pendant son fonctionnement.
8. Ne jamais permettre les personnes avec des vêtements ou des bijous flottants de démarrer ni de faire fonctionner la génératrice car ces vêtements ou bijoux peuvent s’emmêler dans les pièces mouvantes, ce qui pourrait endommager l’équipement et/ou causer des blessures personnelles.
9. Garder toutes personnes à l’écart des pièces mouvantes ou qui peuvent devenir chaudes pendant l’opération.
10. S’assurer que tous les appareils actionnés soient hors circuit avant de les brancher à la génératrice.
BUILT TO LAST
TM
MANUEL
8 Fr
Instructions d’Utilisation
NE JAMAIS FAIRE FONCTIONNER VOTRE GÉNÉRATRICE SOUS CES CONDITIONS:
1. La pluie ou le temps inclément
2. Vibration excessive
3. Étincellement
4. L’allumage du moteur raté
5. Perte de puissance électrique
6. Changement ou variation de la vitesse du moteur
7. Surchauffage de l’équipement branché
8. Prises de courant endommagées
9. Pièces endommagées ou manquantes
10. Pièces détachées protectrices enlevées
TOUJOURS FAIRE FONCTIONNER VOTRE GÉNÉRATRICE SOUS LES CONDITIONS SUIVANTES:
1. Lire et comprendre ces instructions
2. Endroit libre de toutes personnes
3. Mise à la terre correctement (génératrice)
4. Mise à la terre correctement (outils, appareils, etc,.)
5. Surfaces plates et égales
6. Endroit bien aéré
11. Toujours garder la génératrice propre et en bon état de marche.
Ne jamais faire fonctionner cette génératrice dans un endroit explosif ni mal­aéré.
12. S’assurer que tous les outils et appareils soit en bon état de marche et qu’ils soient mis à la terre correctement. Utiliser les appareils avec des cordons d’alimentation à trois broches. Si un cordon prolongateur est utilisé, s’assurer qu’il ait trois broches pour assurer la mise à la terre correcte.
Ne pas
faire fonctionner cette génératrice sur une surface trempe ni dans la pluie.
13. Ne jamais faire fonctionner la
génératrice avec des pièces endommagées, cassées ou manquantes, ni sans pièces protectrices.
Couper
(off) le moteur de la génératrice et débrancher le fil de la bougie d’allumage avant de procéder au service ou à l’entretien du modèle.
14. Utiliser un combustible sans plomb
seulement. Ne pas remplir le réservoir à essence pendant que le moteur soit en marche. Éviter le déversement d’essence pendant le remplissage. S’assurer que le bouchon de réservoir à essence soit en place avant le démarrage du moteur. Permettre que le moteur se refroidisse pour au moins deux minutes avant le remplissage.
Ne jamais
mélanger l’huile avec l’essence pour ce moteur. Utilisez l’huile pour le graissage du moteur seulement.
Généralités sur la Sécurité (Suite)
AUCUN OUTIL EXIGÉ POUR LE MONTAGE
PRÉ-FONCTIONNEMENT
1. Vérifier le niveau d’huile avant chaque démarrage du moteur. Se
référer au Manuel de Moteur pour SAE et API et les spécifications de quantité de remplissage.
2. L’utilisation d’un disjoncteur DDFT (GFCI) est recommandée. Les disjoncteurs DDFT (GFCI) peuvent réduire le risque de blessures s’il y a un court circuit.
Il est possible qu’un interrupteur DDFT (GFCI) ne sera pas efficace si utilisé sur une génératrice qui n’est pas mise à la terre!
3. Suivre tous les codes Locaux et Nationaux pour l’installation d’un disjoncteur DDFT (GFCI), ou contacter un électricien ou technicien diplômé ou certifié.
MISE À LA TERRE
1. Utiliser la borne de mise à la terre et l’écrou à oreilles situé sur le bâti de la génératrice pour brancher le modèle à une source de mise à la terre convenable. Fixer avec sûreté, la borne d’extrémité du fil de terre à la borne de mise à la terre sur le bâti de la génératrice. Serrer la rondelle et l’écrou à oreilles par dessus la borne d’extrémité du fil de terre.
2. Le fil de terre doit être fabriqué de fil de calibre #8. N’utilisez pas un fil avec un numéro de calibre plus haut. Un numéro de calibre plus haut indique un fil plus mince qui ne pourrait fournir un trajet de mise à la terre suffisant.
3. L’autre bout du fil de terre doit être fixé avec sûreté à une source de mise à la terre approuvée.
Les sources de mise à la terre suivantes sont approuvées par le National Electric
Assembly
Fig. 2 - Montage de Manche
Fonctionnement
!
AVERTISSEMENT
!
AVERTISSEMENT
!
DANGER
!
ATTENTION
!
AVERTISSEMENT
Loading...
+ 16 hidden pages