Camden Door Controls CM-331-40, CM-331-41, CM-331-42, CM-331-43, CM-331-44 User Manual

...
0 (0)

CM-331 & CM-332 Series

Active Infrared “Hands-Free” Switches

Installation Instructions

Section 1: General Description

Sure-Wave™ hands-free switches are active infrared devices designed for use with an automatic door operator or other access control products.

Applications include low-energy doors, drive-up windows, health-care facilities, manufacturing… etc.

These units will fit in a variety of locations from 1 ¾” door frames to single and double gang electrical boxes. Various sized surface mount boxes are available from Camden.

There are 2 Line Powered models available:

CM-331 – Single relay output CM-332 – Dual relay output

Three standard faceplates widths are available:

Jamb Mount /N: 1 ¾” x 4 ½” polycarbonate or stainless steel, fits 1 ¾” door frames or our CM-23D jamb box.

Single Gang: 2 ¾” x 4 ½” polycarbonate or stainless steel, fits on single gang electrical boxes

Double Gang /W: 4 ½” x 4 ½” polycarbonate or stainless steel, fits on double gang or 4 x 4 electrical boxes.

All faceplates are available with a variety of graphics/text: /40 Waving Hand symbol

/41 Waving Hand Icon and Wave to open text

/42 Waving Hand Icon, Wave to Open text and Wheelchair symbol

Light Ring – SGLR Option

Camden CM-331 and CM-332 Sure-Wave are available with a light ring option. This provides an illuminated ring for visual confirmation of the switch activation. The light ring can be set to various combinations of colors, Blue, BlueRed, or Green-Red.

BY CAMDEN

CM-TX-99 RF Module

Camden CM-331 and CM-332 Sure-Wave can be fitted with an optional Lazerpoint CM-TX-99 RF Module. The CM-TX-99 RF Module enables the Sure-Wave to product an RF output when activated, that is compatible with our Lazerpoint Series receivers.

Section 2: Installation

Mounting

Sure-Wave may be mounted in door jambs, single or double gang electrical boxes, and 4 x 4 boxes.

NOTE:

The sealing gasket (included) is recommended for outdoor or wet locations. If using with Automatic doors install in accordance with ANSI A156.10 / A156.19. Select from one of the following three mounting subsections:

Single Gang Electrical Box: CM-331 & CM-332

1a – If using an in-wall box ensure the box is plumb and square, and flush with the wall surface. (See Diagram 1)

1b – If using a surface box, ensure it is secure & plumb.

2 – Bring your 4-conductor wire through the back or side of the enclosure and leave approximately 6” tail for wiring connection.

3 – Make the electrical connections to the device according to the wiring section (following).

4 – Using the dip switch located on the end of the unit, set the operating mode. (See Section 4)

5 – Attach the unit to the enclosure using the two #6-32 screws provided.

6 – Apply power and adjust range and time delay via the potentiometers on the front of the unit. (See Section 4 for adjustments)

7 – Attach the faceplate to the unit using the two black #6-32 x 3/8 machine screws or tamperproof screws.

Do not overtighten!!

Page 1 of 8

Camden Door Controls CM-331-40, CM-331-41, CM-331-42, CM-331-43, CM-331-44 User Manual

CM-331 & CM-332 Active Infrared “Hands-Free” Switches Installation Instructions

Smooth

Wall Finish

Wall

Flush

 

Wall Box

 

Rough Wall

 

Finish

 

Recessed

Unaligned

Box

Box

2-Gang (or 4x4) Electrical Box: CM-331W & CM-332W

Diagram 1 - Proper Box Installation

1a – If using an in-wall box ensure the box is plumb and square, and flush with the wall surface. (See Diagram 1)

1b – If using a surface box, ensure it is secure & plumb.

1c – If using a 4 x 4 box, ensure the box is plumb and square, and flush with the wall surface, then attach the metal adaptor plate (included in the CM-331W & CM-332W packages) to the box using appropriate fasteners.

2 – Bring your 4-conductor wire through the back or side of the enclosure and leave approximately 6” tail for wiring connection.

3 – Make the electrical connections to the device according to the wiring section (following).

4 – Using the dip switch located on the end of the unit, set the operating mode. (See Section 4)

5 – Attach the unit to the enclosure using the two #6-32 screws provided.

6 – Apply power and adjust range and time delay via the potentiometers on the front of the unit. (See Section

4for adjustments)

7 – Attach the faceplate to the unit using the two black #6-32 x 3/8 machine screws or tamperproof screws.

Do not overtighten!!

Door Frame: CM-331W & CM-332W

1a – If mounting directly in a 1¾” wide aluminum jamb, make a cutout in the door frame at the intended location as per Diagram 2 on page 4.

Drill and tap two mounting holes as shown.

1b – If mounting the unit in our CM-23d deep jamb box, first mount the jamb box according to the instructions packaged with the enclosure. Using the CM-23D as a guide, drill a wire access hole through the jamb to fish the wiring through.

2 – Bring your 4-conductor wire through the back or side of the enclosure (or Jamb) and leave approximately 6” tail for wiring connection.

3 – Make the electrical connections to the device according to the wiring section (following).

4 – Using the dip switch located on the end of the unit, set the operating mode. (See Section 4)

5 – Attach the unit to the enclosure or jamb using the two #6-32 screws provided.

6 – Apply power, and adjust range and time delay via the potentiometers on the front of the unit. (See Section 4 for adjustments)

7 – Attach the faceplate to the unit using the two black #6-32 x 3/8 machine screws or tamperproof screws.

Do not overtighten!!

Wiring

 

N

C

N

 

 

 

 

 

 

 

 

 

C

O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TB 3

 

 

 

 

 

 

 

 

 

Relay

DIP 3

LED Control

 

 

 

 

 

 

 

1

 

4

 

 

 

 

 

Request To

 

1

 

2 3

DIP Switch

 

 

 

 

 

 

 

O N

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

Exit Input

 

2

 

TB 2

 

 

 

 

 

 

 

Door Contact

 

3

 

 

 

Plugin for

 

 

 

 

 

 

 

 

 

 

 

Input

 

4

 

 

 

 

 

 

 

 

 

 

optional

 

 

 

 

External LED

 

5

 

 

 

 

 

 

 

 

6

 

 

 

CM-TX-99 RF

 

 

 

Ring Control

 

 

 

 

 

module

 

 

 

 

 

TB 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CM-331

Power In Power In

 

 

 

N C

N

 

N

C

N

 

 

 

 

 

 

C

O

 

C

 

O

 

 

 

 

 

 

TB 3

 

TB 4

 

 

 

 

 

 

Relay

DIP 3

Relay

 

 

 

 

 

 

1

 

3 4

 

2

 

 

 

 

 

 

Request To

 

 

1 2

 

 

LED Control

 

 

 

 

 

1

 

O N

 

 

DIP Switch

 

 

 

 

 

Exit Input

2

TB 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Door Contact

3

 

 

 

 

Plugin for

 

 

 

 

 

Input

4

 

 

 

 

 

 

 

 

 

5

 

 

 

 

optional

 

 

 

 

 

External LED

 

 

 

 

 

 

 

 

 

Ring Control

6

 

 

 

 

CM-TX-99 RF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TB 1

 

 

 

 

module

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CM-332

Power In Power In

 

 

 

 

 

Page 2 of 8

CM-331 & CM-332 Active Infrared “Hands-Free” Switches Installation Instructions

CAUTION:

Do not apply power to the unit until all secondary wiring is complete, and dip switches have been set.

Power – TB1

Camden CM-331/332 Sure-Wave switches can be powered from 12 or 24 Volts, AC or DC. Connect power to pins 1&2 on the TB1. This is a non-polarized connection.

Inputs

Camden Sure-Wave switches provide inputs for Door Contacts, Request to Exit and remote control of the LED

Light ring. These inputs are found on TB2. All inputs require a dry contact closure to operate.

TB2 Inputs

Pin

Function

Description

Number

 

 

 

1

Request to Exit

A dry contact closure across these

 

 

 

 

inputs will activate the relay(s) as per

 

 

2

Request to Exit

their settings.

 

 

 

 

3

Door Contact

Normally closed, Used for Security

 

 

4

Door Contact

Mode

 

 

 

 

5

Remote LED

External light ring control. A closed dry

 

 

 

 

contact on this input will toggle the

 

 

6

Remote LED

light ring color.

 

 

 

 

Outputs

The Sure-Wave switches provide Form ‘C’ relay outputs. The CM-331 has 1 Form ‘C’ output and the CM-332 has 2 Form ‘C’ outputs. Selecting the correct output is also dependant on the operating mode chosen. Most applications will utilize the N.O. and Common terminals.

Relay 1 Output (TB3)

1Normally Closed

2 Common

3Normally Open

Relay 2 Output (TB4), (CM-332)

1Normally Closed

2 Common

3Normally Open

Section 3: Applications & Set-up

Applications

DIP 1

DIP 2

 

 

LED Enable

O N

O N

Motion Sensing

 

2 1

2 1

 

Audio Enable

Modes

 

 

Fail Safe

4 3

4 3

Relay Operation

EXT

 

 

Modes

 

 

Sounder

 

 

J 1

 

 

 

 

 

Activate

 

 

 

 

 

LED

 

 

Error/Alarm

 

 

 

 

 

LED

 

 

 

 

 

 

 

 

POT 2

 

 

POT 1

 

 

Relay

 

 

 

 

OP Time

 

Range

 

 

 

 

 

Adj.

 

 

 

 

 

 

 

 

DIP 1

 

CM-331

 

LED Enable

O N

 

Audio Enable

 

2 1

 

 

 

Fail Safe

 

3

 

 

 

 

 

 

 

 

EXT

 

4

 

 

 

 

 

 

 

Sounder

 

 

 

 

Error/Alarm

 

 

 

 

 

LED

 

 

 

 

POT 3

 

 

 

 

Range Sequence

 

 

 

 

Delay Adj.

 

 

POT 1

Range Adj.

CM-332

DIP 2

1 Motion Sensing

O N

Modes

2

3

Relay Operation

4

Modes

 

J 1

 

Relay

 

LED

POT 2

Relay 1

OP Time

POT 4

Relay 2

OP Time

DIP 1 – Options Switch

SW1 – LED Enable

When SW1 is ON, the green LED will illuminate when the switch is activated. When SW 1 is OFF (default), the green LED will remain off.

SW2 – Audio Enable

When SW2 is ON, an audible beep is generated when the switch is activated. When SW2 is OFF (default), no audible beep is generated.

SW3 – Fail Safe/Fail Secure

This option changes the state of the relays on the Sure-Wave switches. When SW3 is ON, the relay outputs are switched. NO becomes NC and NC becomes NO. SW3 is OFF by default.

SW4 – External LED Control

The LED light ring can be controlled externally by providing a contact closure on the REM input (pins 5&6) on TB2. When SW4 is ON, a contact closure across the REM input will change the light ring color from its idle to active colors.

When SW4 is OFF, the light ring colors change with the state of the switch.

Page 3 of 8