Bunn TF Server DSG2 1.0, TF Server DSG2 1.5 Owner's Manual

0 (0)

Digital

ThermoFresh®

1.0 & 1.5 Gallon Server

with Countup Timer

USE & CARE INFORMATION

CAUTION: CLEAN AND SANITIZE YOUR SERVER BEFORE USING. SEE NOTE #1 of DAILY CLEANING.

BUNN-O-MATIC CORPORATION OF CANADA

280 INDUSTRIAL PARKWAY SOUTH,

AURORA, ONTARIO, L4G 3T9

PHONE: (905) 841-2866 FAX: (905) 841-2775

43240.7009B 11/12 ©2012 Bunn-O-Matic Corporation

INTRODUCTION

This server is intended for use with a BUNN® DUAL® TF DBC®, SINGLE® TF DBC® or ICB family brewers. When proper precautions are followed, 1.0 up to 1.5 gallons of coffee may be brewed directly into the server and then transported to a remote serving location. The server must be placed on a sturdy counter or shelf.

NOTE: Calibration of the brewer is required prior to the use of the Digital TF Server.

USER NOTICES

The notices on this server should be kept in good condition. Replace unreadable or damaged labels.

WARNING

 

 

AVERTISSEMENT

 

 

 

 

HOT LIQUID

 

 

LIQUIDE CHAUD

 

 

 

 

 

 

 

 

35710.7000

DO

NE

 

 

 

 

 

 

 

E

 

 

 

N

 

 

 

 

G

 

 

 

 

 

 

E

 

 

 

 

 

 

O

M

R

 

 

 

 

 

 

T SUB

 

 

 

R

 

 

 

P

 

 

 

E

 

 

 

 

 

G

 

 

 

 

 

 

A

 

R

 

 

 

 

 

 

 

 

S IMME

 

 

 

 

 

 

 

45457.7000

 

39043.0000

39043.0001

39043.0002

DAILY CLEANING

CAUTION: CLEAN AND SANITIZE YOUR SERVER DAILY

NOTE: Bunn-O-Matic recommends the 3 step method for cleaning and sanitizing the server. The 3 step method consists of hot soapy water using an approved detergent, a fresh water rinse, and an aqueous sanitizing solution using an approved non-chlorine sanitizer. Do not submerge server.

1.Run a complete brew cycle of just hot water into the server and let it set for a minute. Empty the server completely by opening the faucet.

2.Remove the sensor assembly, fill server with cleaning solution and thoroughly clean the inside of server.

3.Rinse server thoroughly using fresh water rinse.

4.Fill server with sanitizing solution and let the server set for 5 minutes, then drain through fully open faucet. Thoroughly rinse server after sanitizing.

5.Remove the faucet handle/stem assembly by unscrewing the faucet nut just beneath the faucet handle.

6.Use enclosed cleaning brush to thoroughly clean the faucet body and tube.

7.Disassemble the faucet/stem assembly. Thoroughly wash all faucet parts in a mild detergent and water solution. Rinse the parts in hot water. Sanitize the parts for five minutes, thoroughly rinse, then air dry completely.

8.Use enclosed cleaning brush to thoroughly clean the fill tube of the sensor assembly.

NOTE: Never submerge the Digital ThermoFresh® Server Display or sensor assembly in water.

9.Wipe sensor assembly with a clean, damp cloth.

10.Reassemble the faucet and attach it to the dispenser.

11.Wash the entire outside surface of the server and display with a clean damp cloth.

PERIODIC CLEANING

1.Remove the sensor assembly from the server.

2.Remove the two thumb screws and slide display assembly from the server.

3.Wipe the surface of the display unit, area under the display unit, and sensor assembly with a clean damp cloth.

4.Wash the entire outside surface of the sensor assembly with a mild detergent and water solution and rinse with hot water. Do not submerse. NOTE: Thoroughly cleaning the sensor assembly fins will prevent inaccurate level readings.

5.Replace the display unit and sensor assembly.

2

43240.9 030912

 

SERVER WITH STAND

REPLACEMENT PARTS

17

16 15 14 13

1.

42554.1001

Display Kit, Countup (Includes items 2 - 4)

 

 

 

42826.1000

Screw, Thumb #6-32 x .25"

 

12 34

2.

46247.1000

Batteries, 4 Pack AAA

 

1

3.

42546.0001

Gasket, Battery Cover

 

 

4.

42547.0001

Cover, Battery

 

2

 

02361.0000

Screw, Pan Head #4-40 x .25"

 

 

5.

43135.0000

Handle, Faucet

18

3

6.

29165.1002

Faucet Bonnet

 

 

7.

00601.1000

Faucet Spring (Package of 6)

32

4

8.

29164.1000

Faucet Stem (Package of 6)

 

 

9.

00600.1000

Faucet Seat Cup (Package of 6)

19

5

10.

42567.0000

Faucet Body

 

 

11.

42543.0000

Guard, Faucet

33

6

 

35074.1000

Screw, Pan Head M4 x .7 x .25

 

 

12.

43231.0000

Washer, M4 x 9MM

35

7

42584.1000

Plug, Front (Package of 10)

 

 

13.

42818.1001

Sensor Assy, 1.0 Gal (Includes items 14 &15)

20

8

 

42565.1000

Sensor Assy, 1.5 Gal (Includes items 14 &15)

 

 

14.

42563.1002

Cap, Sensor Assy (Package of 5)

21

9

15.

39043.0000

Decal, Do Not Submerge

 

 

16.

42562.0000*

Handle, Server

22

10

17.

42758.0000*

Shoulder Screw

 

 

18.

42585.1000

Plug, Rear (Package of 10)

23

11

19.

43246.1000

Cover Assy, Top

 

 

 

42761.0000*

Screw, Pan Head M4 x 9

24

 

20.

35710.0000

Decal, Warning Hot Liquid

 

 

21.

32591.1000

Tube, Silicone .50" ID x 12.0" LG (cut to length)

25

 

22.

28526.1000

Tube, Silicone .31" ID x 12.0" LG (cut to length)

 

31

23.

42912.0000

Foot, Rubber

26

 

 

43163.0000

Screw, Pan Head #8 x .75"

 

 

24.

42295.0001

Elbow, 90°

27

 

25.

42890.1000

Base Cover

 

 

26.

35016.0001

Insert, Stand

 

 

27.

38929.0002

Stand, Server

 

 

 

39617.0000

Screw, Pan Hd Plastite #6 x .75"

28

 

28.

38930.0002

Base Plate, Stand

 

 

 

44010.0000

Screw, Pan Head #8 x .50"

29

 

29.

39443.1003

Pad, Adhesive Back .75" Dia.

 

 

30.

38931.1002

Kit, Drip Tray (Includes item 31)

 

P4166

31.

38932.0000

Cover, Drip Tray

 

 

 

32.

45457.0000*

Decal, Do not Submerge

 

 

33.

39043.0002*

Decal, Do not Spray

 

30

34.39043.0001* Decal, Do not Submerge Server

35.42889.0000 Seal

36.35071.0000 Decal, Black Wrap 1.5 Gal. (Not Illustrated)

37974.0000 Decal, Black Wrap 1.0 Gal. (Not Illustrated)

37.35301.0001 Brush, Cleaning (Not Illustrated)

*Components of item 19

3

43240.9 030912

Bunn TF Server DSG2 1.0, TF Server DSG2 1.5 Owner's Manual

SERVER WITHOUT STAND

REPLACEMENT PARTS

17

16

15

14

13

 

1.42554.1001 Display Kit, (Countup)(Includes items 2 - 4)

 

42826.1000

Screw, Thumb #6-32 x .25"

12

28

2.

46247.1000

Batteries, 4 Pack AAA

 

 

3.

42546.0001

Gasket, Battery Cover

 

 

4.

42547.0001

Cover, Battery

 

 

 

02361.0000

Screw, Pan Head #4-40 x .25"

 

 

5.

43135.0000

Handle, Faucet

 

 

6.

29165.1002

Faucet Bonnet

18

 

7.

00601.1000

Faucet Spring (Package of 6)

 

8.

29164.1000

Faucet Stem (Package of 6)

26

 

9.

00600.1000

Faucet Seat Cup (Package of 6)

 

10.

42567.0000

Faucet Body

19

 

11.

42543.0000

Guard, Faucet

 

 

35074.1000

Screw, Pan Head M4 x .7 x .25

27

 

 

43231.0000

Washer, M4 x 9MM

 

12.

42584.1000

Plug, Front (Package of 10)

29

 

13.

42818.1001

Sensor Assy, 1.0 Gal (Includes items 14 &15)

 

 

42565.1000

Sensor Assy, 1.5 Gal (Includes items 14 &15)

20

 

14.

42563.1002

Cap

 

15.

39043.0000

Decal, Do Not Submerge

21

 

16.

42562.0000*

Handle, Server

 

17.

42758.0000*

Shoulder Screw

22

 

18.

42585.1000

Plug, Rear (Package of 10)

 

19.

43246.1000

Cover Assy,

23

 

 

42761.0000*

Screw, Pan Head M4 x 9

 

20.

35710.0000

Decal, Warning Hot Liquid

24

 

21.

32591.1000

Tube, Silicone .50" ID x 12.0" (cut to length)

 

22.

28526.1000

Tube, Silicone .313" ID x 12.0" (cut to length)

25

 

23.

42912.0000

Foot, Rubber

 

 

43163.0000

Screw, Pan Head #8 x .75"

 

 

24.

42295.0001

Elbow, 90°

 

 

25.

42890.1000

Base Cover

 

 

26.45457.0000* Decal, Do not Submerge

27.39043.0002* Decal, Do not Spray

28.39043.0001* Decal, Do not Submerge Server

29.42889.0000 Seal

30.35071.0000 Decal, Black Wrap 1.5 Gal. (Not Illustrated)

37974.0000 Decal, Black Wrap 1.0 Gal. (Not Illustrated)

31.35301.0001 Brush, Cleaning (Not Illustrated)

*Components of item 19

STAND FOR SERVERS WITHOUT STAND

REPLACEMENT PARTS

-39795.0003 Stand, Assy (Includes items 1 - 8)

1.

39449.0005

Bracket, Rear

2.

39448.0003

Bracket, Front

3.

38929.0002

Stand, Server

4.00970.0000 Nut, Keps #8-32

5.38930.0002 Base Plate, Stand

44010.0000

Screw, Pan Head #8 x .50"

6.39443.1003 Pad, Adhesive Back .75" Dia.

7. 38932.0000

Cover, Drip Tray

8.38931.1002 Drip Tray Kit (Includes item 7)

2

1

3

 

4

5

6

1

2

3

4

5

6

7

8

9

10

11

7

8

4

43240.9 030912

 

DIGITAL DISPLAY

The Digital ThermoFresh® Server is equipped with a digital probe and display called a Digital Sight Gauge. The probe contains a circuit board designed to sense liquid levels & hold times. During the monitoring process, the probe sends information to the display. The display then allows the user to monitor the liquid level and freshness (hold time) of the beverage held in the server.

HORIZONTAL BAR

Using the Digital Sight Gauge display, the liquid level in the server can be

 

monitored by watching the horizontal bars. The 1.0 gallon display is equipped with

 

4 bars and the 1.5 gallon with 6 bars to represent the level inside the dispenser.

 

(each bar represents a quart, or one quarter of a gallon)

 

All four/six bars will be displayed when the server is full. When the level of

 

the liquid drops to a certain level, the highest bar on the display will no longer be

 

illuminated. These bars will continue to disappear as the level inside the dispens-

 

er drops. (See Fig. 1)

 

COUNT UP TIMER

FIG. 1

The Digital display is set to count up to 4:00 hours. The display counts up in one minute increments, flashing at 2:00 hours and continuing to flash once it reaches 4:00 hours. (See Fig. 1)

TIMER RESET

The display will reset to 0 when any of the following occurs:

The liquid level in the server is increased by 1 bar for a sustained period of time. (brewing into, or adding additional liquid to existing beverage)

A fresh new beverage is brewed into the server.

When the contact pins of the sensor assembly are disengaged from the display for more than 20 seconds.

DISPLAY OFF

When the sensor assembly on the server is removed or loosened for more than 20 seconds, the display on the Digital Sight Gauge breaks contact with the pins on the surface of the server. When this happens, the outline that surrounds the Horizontal Level Bars will flash on and off and the time disappears. This indicates that the display has been disengaged from the probe and cannot receive data.

When the display is in place and engaged, but the server is empty, the outline surrounding the Horizontal Level Bars will be on but not flashing and the Freshness Time will not be displayed. All other portions of the display will not be visible. This indicates the display is engaged and ready to receive data from the probe, but the server is empty.

The only time the display will be completely blank, is when the batteries have been removed or have expired. (See the “Battery Replacement” section for additional

information.)

Flashing Notification Table

 

Position

Minutes

FRESHNESS TIME

0

30

1

60

This unit is factory set to count up to 2:00 hours, and begin flashing. If a reset condition

2

90

has not occurred, it will continue to flash and count up to a maximum of 4:00 hours.

3

120 (Default)

Flashing notification is adjustable and can be set between 15 minutes and 3 hours 45

4

150

5

180

minutes in 15 minute increments. Setting changed by opening battery compartment and

6

210

positioning rotary switch using a small screwdriver. Settings are defined in the Flashing

7

240

Notification Table.

8

15

 

LOW BATTERY INDICATOR

9

45

A

75

When the batteries in the display unit are running low, the display is also equipped with

B

105

C

135

a battery icon. The upper most bar used in monitoring liquid levels, will begin to flash in the

D

165

shape of a battery to indicate that it is time to replace the batteries. (See FIG. 1)

E

195

 

 

F

Disable Timer

5

43240.9 030912

 

Loading...
+ 9 hidden pages