Bunn LCA-2, Chilled LCC-2, LCA-2 PC User Manual

1.96 Mb

LCA-2

LCA-2 PC

LCC-2

POW

ER

 

READ

Y

 

TION

POR

 

RIN

SE

REFI

LL

 

HO

 

INSTALLATION & OPERATING MANUAL

BUNN-O-MATIC CORPORATION

POST OFFICE BOX 3227

SPRINGFIELD, ILLINOIS 62708-3227

PHONE: (217) 529-6601 FAX: (217) 529-6644

To obtain the Illustrated Parts Catalog, visit the Bunn-O-Matic website, at www.bunn.com. This is absolutely FREE, and the quickest way to obtain the catalog. Contact Bunn-O-Matic Corporation at 1-800-286-6070 to obtain a paper copy of the required Illustrated Parts Catalog mailed via U.S. Postal Service.

34766.0000J 01/07 ©2002 Bunn-O-Matic Corporation

www.bunnomatic.com

CONTENTS

Warranty...........................................................................

2

Introduction......................................................................

3

User Notices.....................................................................

3

Electrical Requirements....................................................

4

Plumbing Requirements...................................................

5

Initial Set-up.....................................................................

5

Electrical Hook-up............................................................

5

Plumbing Hook-up...........................................................

5

Setting Dispenser Flow Rate.............................................

6

Selecting the Correct Pump Tubing..................................

7

Operating Controls & Interface.........................................

8

Initial Fill & Heat...............................................................

9

FlavorGard™ Feature.......................................................

10

Rinse Alarm Feature.......................................................

10

BIB Empty Lockout Feature............................................

11

Brew Temperature Lockout Feature................................

11

Programming the Dispenser Flow Rate..........................

12

Loading the Concentrate.................................................

18

Priming the Concentrate Lines........................................

18

Operating the Pull & Hold Dispenser..............................

19

Operating the Preset Portion Control Dispenser.............

20

Filling Cambros or other large containers.......................

20

Cleaning & Preventive Maintenance................................

21

Replacing the Pump Tubing............................................

22

Draining the Hot Water...................................................

23

Troubleshooting..............................................................

24

Field Calibration of the Concentrate Pumps....................

29

Dispenser Flow Rate Calibration.....................................

30

Field Calibrating the Hot Water Flow Rate.......................

30

Field Calibrating the Empty BIB Warning........................

31

Schematic Wiring Diagrams...........................................

32

BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY

Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows:

1)All equipment other than as specified below: 2 years parts and 1 year labor.

2)Electronic circuit and/or control boards: parts and labor for 3 years.

3)Compressors on refrigeration equipment: 5 years parts and 1 year labor.

4)Grinding burrs on coffee grinding equipment to grind coffee to meet original factory screen sieve analysis: parts and labor for 3 years or 30,000 pounds of coffee, whichever comes first.

These warranty periods run from the date of installation BUNN warrants that the equipment manufactured by it will be commercially free of defects in material and workmanship existing at the time of manufacture and appearing within the applicable warranty period. This warranty does not apply to any equipment, component or part that was not manufactured by BUNN or that, in BUNN’s judgment, has been affected by misuse, neglect, alteration, improper installation or operation, improper maintenance or repair, damage or casualty. This warranty is conditioned on the Buyer 1) giving BUNN prompt notice of any claim to be made under this warranty by telephone at (217) 529-6601 or by writing to Post Office Box 3227, Springfield, Illinois 62708-3227; 2) if requested by BUNN, shipping the defective equipment prepaid to an authorized BUNN service location; and 3) receiving prior authorization from BUNN that the defective equipment is under warranty.

THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTY, WRITTEN OR ORAL, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF EITHER MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. The agents, dealers or employees of BUNN are not authorized to make modifications to this warranty or to make additional warranties that are binding on BUNN. Accordingly, statements by such individuals, whether oral or written, do not constitute warranties and should not be relied upon.

If BUNN determines in its sole discretion that the equipment does not conform to the warranty, BUNN, at its exclusive option while the equipment is under warranty, shall either 1) provide at no charge replacement parts and/or labor (during the applicable parts and labor warranty periods specified above) to repair the defective components, provided that this repair is done by a BUNN Authorized Service Representative; or 2) shall replace the equipment or refund the purchase price for the equipment.

THE BUYER’S REMEDY AGAINST BUNN FOR THE BREACH OF ANY OBLIGATION ARISING OUT OF THE SALE OF THIS EQUIPMENT, WHETHER DERIVED FROM WARRANTY OR OTHERWISE, SHALL BE LIMITED, AT BUNN’S SOLE OPTION AS SPECIFIED HEREIN, TO REPAIR, REPLACEMENT OR REFUND.

In no event shall BUNN be liable for any other damage or loss, including, but not limited to, lost profits, lost sales, loss of use of equipment, claims of Buyer’s customers, cost of capital, cost of down time, cost of substitute equipment, facilities or services, or any other special, incidental or consequential damages.

34766 010407

INTRODUCTION

The Liquid Coffee Ambient Dispenser (LCA-2) and the Liquid Coffee Chilled Dispenser (LCC-2) delivers two types of coffee plus hot water. The dispenser can be set up for continuous draw (by the cup) for self-serve applications, or portion-control to fill carafes and decanters for wait staff. Product Flavor Profile is extended with chilled product storage cabinet featured in the LCC-2.

USER NOTICES

Carefully read and follow all notices on the equipment and in this manual. They were written for your protection. All notices are to be kept in good condition. Replace any unreadable or damaged labels.

00986.0002

To reduce the risk of electric shock, do not remove or open cover.

No user-serviceable parts inside. Authorized service personnel only. Disconnect power before servicing.

This equipment must be installed to comply with the Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the Food and Drug Administration (FDA). For models installed outside the U.S.A., comply with the applicable Plumbing /SanitationCode.

00656.0000

Optional Field Wiring

208-240 V, 25.8 A, 6200 W 1PH, 2-Wire + GND, 60HZ or

120/208-240 V, 25.8 A, 6200 W 1PH, 3-Wire + GND, 60HZ

37881.0000

28181.0003

 

11646.0002

34766 010407

HEATER RED
10A. FUSE - WHITE
HEATER RED

ELECTRICAL REQUIREMENTS

CAUTION: The dispenser must remain disconnected from the power source until specified in Electrical HookUp.

The LCA-2 and LCC-2 dispensers are supplied with a 120-volt / 15 Amp cord set and require a 2-wire, grounded, individual branch circuit rated for 120 volts AC, 15 amp, single phase, 60Hz. The mating connector must be a NEMA 5-15R.

The LCA-2C and LCC-2C dispensers are supplied with a 120-volt / 20 Amp cord set and require a 2-wire, grounded, individual branch circuit rated for 120 volts AC, 20 amp, single phase, 60Hz. The mating connector must be a NEMA 5-20R.

These dispensers can be Field Wired for 208 or 240 volt applications. This requires a 2 or 3-wire, grounded, individual branch circuit rated for 208/240 volts AC, 30 amp, single phase, 60 Hz.

NOTE: The internal terminal block must be rewired for 208/240 applications, (see Optional Field Wiring Diagram).

FIELD WIRING TERMINAL BLOCK DIAGRAM

Models without Master ON/OFF Switch

HEATER RED

10A. FUSE - WHITE

10A. FUSE - BLACK

LIMIT SW. - BLACK

 

 

208 or

10A. FUSE - WHITE

120V A.C.

10A. FUSE - BLACK

240V A.C.

10A. FUSE - BLACK

 

Fig. 1

LIMIT SW. - BLACK

Fig. 2

LIMIT SW. - BLACK

For all 208 - 240 Volt Connections: Use No. 10 AWG Wires suitable for 90°C (194 °F)

120V

A.C.

208

 

or

 

 

 

240V A.C.

120V

A.C.

 

 

 

 

 

 

 

 

Fig. 3

1.Unit shipped per Fig. 1, wired for 120V A.C./2-Wire.

2.For 208 - 240V A.C./2-Wire per Fig. 2: Move both the Red-Heater wire and the White-Fuse wire to the Top Red Terminal as shown.

3.For 120/208 - 240V A.C./3-Wire per Fig. 3: Move the Red Heater wire to the Top Red Terminal as shown.

FIELD WIRING TERMINAL BLOCK DIAGRAM

Models with Master ON/OFF Switch

RED

 

RED

 

RED

 

 

TO MASTER

120V A.C.

TO MASTER

208 or

TO MASTER

120V A.C.

208 or

ON/OFF

ON/OFF

ON/OFF

 

240V A.C.

240V A.C.

SWITCH

 

SWITCH

 

SWITCH

120V A.C.

 

BLACK

Fig. 1

BLACK

Fig. 2

BLACK

Fig. 3

 

 

 

 

 

For all 208 - 240 Volt Connections: Use No. 10 AWG Wires suitable for 90°C (194°F)

1.Unit shipped per Fig. 1, wired for 120V A.C./2-Wire.

2.For 208 - 240V A.C./2-Wire per Fig. 2.

3.For 120/208 - 240V A.C./3-Wire per Fig. 3.

34766 010407

PLUMBING REQUIREMENTS

The dispenser may be connected to a cold or hot water system (140°F Max.) with operating pressure between 20 and 90 psi (138 and 620 kPa) from a 1/2” or larger supply line. A shut-off valve should be installed in the line before the dispenser. Install a regulator in the line when pressure is greater than 90 psi (620 kPa) to reduce it to 50 psi (345 kPa). The water inlet fitting is 3/8” flare. Dispensers set up to deliver to 1.8 Oz./sec. (53.2 ml/sec) per dispense tip, require a water supply source that can deliver a minimum of 1.7 gpm (6.4 lpm) at the inlet fitting. Dispensers set up to deliver 2.6 Oz./sec. (76.9 lpm) per dispense tip, require a water supply source that can deliver a minimum of 2.4 gpm (9.2 lpm) at the inlet fitting.

NOTE: Bunn-O-Matic recommends 3/8” tubing from the 1/2” water supply line. At least 18 inches of FDA approved flexible beverage tubing, such as reinforced braided polyethylene or silicone, before the dispenser will facilitate movement to clean the counter top. Bunn-O-Matic does not recommend the use of a saddle valve to install the dispenser. The size and shape of the hole made in the supply line by this type of device may restrict water flow.

This equipment must be installed to comply with the Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the Food and Drug Administration (FDA). For models installed outside the U.S., you must comply with the applicable Plumbing/Sanitation Code for your area.

INITIAL SET-UP

NOTE: The LCC-2 (Chilled Unit) weighs approximately 80 lbs. (36.3 kg) and the LCA-2 (Ambient Unit) weighs approximately 70 lbs. (31.8 kg). If necessary, use more than one person when lifting or moving the dispenser.

1.Locate and remove the information packets and tube kits from top of packaging and set aside.

2.Remove foam packing and cut around the bottom of box.

3.Remove the box and the rest of the foam packing.

4.Open the dispenser door and remove the drip tray and the lower splash guard panel.

5.Set dispenser on the counter where it is to be used. CAUTION: DO NOT LIFT ON THE DOOR.

6.Confirm the dispenser is level on the counter.

ELECTRICAL HOOK-UP

CAUTION: Improper electrical installation will damage electronic components.

1.An electrician must provide electrical service as specified in conformance with all local, state and federal electrical codes.

2.Using a voltmeter, check the voltage and color-coding of each conductor at the electrical source.

3.Connect the dispenser to the power source.

4.If plumbing is to be hooked up later, be sure the dispenser is disconnected from the power source. If plumbing has been hooked up, the dispenser is ready for Initial Fill & Heat.

PLUMBING HOOK-UP

1.Flush the water line to remove any debris or foreign material.

2.Securely attach the water line to the 3/8” flare fitting, on bottom right side of the dispenser.

3.Turn on the water supply and check for leaks.

34766 010407

SETTING DISPENSER FLOW RATE

The dispenser comes from the factory with flow restrictors in the mix chambers. With the restrictors in place the dispense rate is about 1.8 oz./sec (53.2 ml/sec) and is used primarily for cup at a time dispensing. The flow restrictors can be removed to increase the dispense rate to about 2.5 oz./sec (74 ml/sec) for larger volume dispensing (airpots, carafes, etc.).

NOTE: The hot water FlowRate is fixed at approximately 1.7 oz/sec. and can not be adjusted.

Removing the restrictors:

1.Disconnect the dispenser from the AC power source.

2.Open the Product Cabinet door.

3.Remove the concentrate tube, vent line and grommet from mix chamber ports in side the product cabinet.

4.Remove the two screws that fasten mix chamber to the control panel.

5.Gently pull mix chamber away from dispenser to expose water line connection, (you may have to rotate it slightly).

6.Disconnect FlavorGard™ sensor wire and hot water tubing from the mix chamber.

7.Remove the flow restrictor from the inlet to the mix chamber.

8.Reconnect FlavorGard™ sensor wire and hot water tubing to the mix chamber.

9.Place mix chamber back into position in the dispenser, (you may have to rotate it slightly) and secure it with the two screws

10.Reposition the grommet, vent line and pump tubing onto the mix chamber ports.

Caution: Failure to properly replace and secure any of the above components may result leaks and/or cause damage to the dispenser.

If you changed the Dispenser Flow Rate, you will need to reprogram the dispenser to the new rate, seeProgramming the Dispenser.

CAUTION: Failure to reprogram the Dispenser Flow Rates will result in inaccurate Mix Ratios.

Reprogramming the Dispenser Flow Rate:

1.Remove the lower splash guard panel and locate the Programming module.

2.Use the Down Arrow key to enter into the programming function and scroll through the menu’s to the “CAL LEFT SIDE?” menu and select “YES”.

3.Scroll down to the “CAL LF WTR VOL” menu

4.Use the (+) & (-) keys to enter a volume of 50 Oz. (1478 mL). This will recalibrate the Left dispenser to the new rate.

5.Scroll down to the “CAL RT WTR VOL” menu

6.Use the (+) & (-) keys to enter a volume of 50 Oz. (1478 mL). This will recalibrate the Right dispenser to the new rate.

7.Select “Exit” to leave the programming menu.

Note: The default volume of 50 Oz (1478 mL), is the typical Cal Volume for a 2.5 Oz/sec Flow Rate Test, see Field Calibration of the Concentrate Pumps / Dispenser Flow Rates.

34766 120105

SELECTING THE CORRECT PUMP TUBING

There are two pump tube sizes available for use with this dispenser. To determine the correct tubing for you application, first determine the dispenser flow rate you intend to use, refer to Setting Dispenser Flow Rate. Then look up the recommended tube size for the mix ratio of your concentrate, refer to the Tube Selection Chart.

 

 

 

 

 

 

TUBE SELECTION CHART

 

 

 

 

 

 

 

 

 

 

Dispense

Concentrate Ratios

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rate

25

30

35

40

45

50

55

60

65

70

75

 

80

85

90

 

95

100

 

1.8 Oz/sec.

3/16” I.D. TUBING

 

 

 

 

1/8” I.D. TUBING

 

 

 

 

 

 

(53 ml/sec.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.5 Oz/sec.

3/16” I.D. TUBING

 

 

 

 

 

 

 

1/8” I.D. TUBING

 

 

 

(74 ml/sec.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Examples:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.For a Dispenser Flow Rate of 2.5 Oz./sec (74 mL/sec) and a Mix Ratio of 35:1 – use 3/16” I.D. Tubing.

2.For a Dispenser Flow Rate of 1.8 Oz./sec (53 mL/sec) and a Mix Ratio of 60:1 – use 1/8” I.D. Tubing.

Tube kits can be purchased from BUNN-O-MATIC.

Part # 34727.1000 for 3/16” I.D. Tubing or #34728.1000 for 1/8” I.D. Tubing.

INSTALLING THE PUMP TUBING (Refer to the Tubing Installation Instructions in side the cabinet door for details.)

1.Loosen the thumbscrew securing the tubing retainer plate to the pump housing. Set it and the retainer plate aside.

2.Depress the tension screw and remove it from the notch in the pump body, releasing the spring tension on the pump band.

3.Apply lubricant (BUNN-O-MATIC part number M2531.0001) to the new pump tubing.

4.Insert the tubing onto the mix chamber port and wrap the tubing around the pump rotor, making sure that the elbow and clamps end up on the bottom side of the pump body.

5.Close the compression band reinsert the tension screw into the notch in the pump housing.

6.Replace the tubing retainer plate and tighten the thumbscrew.

7.Reconnect bag connector to the product box.

8.Repeat steps 1 through 7 for the other pump.

9.Prime the pumps. Refer to Priming the Concentrate Lines section.

Thumbscrew

 

 

 

 

 

 

 

 

 

 

 

 

 

Tension

 

 

 

 

2.0”

 

 

 

 

 

2.0”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Screw

 

Lubricate between arrows

 

 

Remove Retaining Plate Release Spring Tension

Remove Tubing

 

 

Lubricate New Tube

Tension Screw

 

Tube Clamp

 

Install New Tubing

Completed Installation

34766 112502

OPERATING CONTROLS AND INTERFACE

1a. Dispense Handles: Pull and Hold to dispense product.

1b. Dispense Switches: Push and Release to dispense product for Portion Control Models. 2. Stop Switch: Momentary switch stops all dispense functions.

3a. Hot Water Switch: Push and Hold switch to dispense hot water from the center dispense tip. 3b. Push and Release switch for Portion Control Models.

4.Alternate Portion Control Switch: Momentarily pushed to select the Alternate Portion Control Volume #2.

5.Function Selector Switch: Allows the user to set the dispenser into different dispensing modes.

a.Rinse: Dispenses hot water onlyFlushes the mix chamber and dispense tip.

b.Prime: Dispenses concentrates only – Primes the concentrate pump.

c.Normal: Normal dispense mode - Dispenses mixed product (concentrate and water).

6.Mode Selector Switch: Allows the user to set the dispenser into different operating modes.

a.Run: Normal operating position.

b.Off: Turns off all functions including tank heater and chiller.

WARNING - The OFF Mode does not remove AC power from the dispenser. Disconnect power source before servicing the dispenser

c.Night: Anti-pilfering mode that disables dispensing, but keeps the tank heater and chiller (if applicable) operational.

7.Door Interlock Switch: Unit will not dispense product if the door is open.

8.Power LED: Red - illuminates when AC power is applied to dispenser.

9.Ready LED: Green - illuminates when the water is at the preset ready temperature.

10.Portion LED: Yellow - illuminates when the portion dispense option has been selected, (5 second delay).

11.Rinse LED: Yellow - illuminates when the optional preset rinse alarm time has elapsed.

12.Left Refill LED: Yellow - illuminates when the Left Concentrate BIB needs replaced.

13.Right Refill LED: Yellow - illuminates when the Right Concentrate BIB needs replaced.

14.Programming Keypad: Used in conjunction with the LCD display to program and calibrate the dispenser to customer specific requirements. (Located behind the splash guard panel)

15.LCD Display: Displays programming menus and fault messages. (Located behind the splash guard panel)

5

6

1

4

BUNN ICED COFFEE

AMBIENT UNIT

8

7 9

10

11

12

15 13 14

2

3

34766 120105

INITIAL FILL & HEAT

1.Select Normal on the Function Selector Switch and Run on the Mode Selector Switch.

2.Confirm the water supply is on.

3.Connect the dispenser to the power source. The Red POWER LED will illuminate and water will begin flowing into the tank. The dispenser will automatically stop filling when the tank is full. The dispenser will not begin heating the water until after the tank is filled. Dispenser models with product chillers will begin to cool the cabinet at this time.

4.The Green READY LED will illuminate when the tank temperature reaches the preset ready temperature. Note: The time required to heat the water initially will vary depending on the AC Power supplied to the dispenser.

While the tank is heating, the dispenser may be readied for use as described in Programming Functions & Basic 1 1

3

4

34766 112502

Alarm Level Selected
Disabled Warning Only
Warning w/ Brew Lockout

FlavorGard™ Feature

FlavorGard™ is a patented feed back control loop that monitors the mixed product and adjusts the concentrate delivery rate to maintain a consistent mix profile, i.e. Flavor Profile. The system consists of a conductance probe mounted in the final stages of the mixing chamber, a metering pump with RPM sensor and a digital controller. Once you have completed the installation of the dispenser, entered the desired mix ratio for your concentrate, dispensed several cups of the mixed product, and are satisfied with the Flavor and Strength being delivered, simply enable FlavorGard™, (refer to FlavorGard™ in Programming the Dispenser).

The dispenser will automatically calibrate the system to all the factors that make up your particular mix profile, (e.g. water source, filtration system, Brand of concentrate and mix ratio selected, etc.).

NOTE: It is very important that you have dispensed enough product to insure that the dispenser is fully functional and you are satisfied with the Flavor Profile of the mix product before enabling FlavorGard™.

Once FlavorGard™ is enabled, the dispenser will continuously monitor the mix product as it is being dispensed and adjust the metering pump speed to maintain a consistent mixed product, thus eliminating factors such as (settling of the concentrate, tube wear, viscosity changes, liming, etc.).

The system is designed to work with in the range of variations that can be caused by these factors. The factory preset range is (+/- 10 %) and is adjustable to a Max of (+/- 15%). This insures that the FlavorGard™ system is not responding to factors that cannot be corrected by minor adjustments to the speed of the metering pump, (e.g. kinked hoses, low water pressure, severely worn tubes, empty BIB’s, etc).

NOTE: Changes to Concentrate Ratios or Dispenser Flow Rates will automatically disable FlavorGard™. You will need to re-enable FlavorGard™, once you are satisfied with the new Flavor Profile.

Rinse Alarm Feature

Periodic rinsing of the mix chambers and dispense tips is essential for proper maintenance and optimum performance of the dispenser. The automated Rinse Alarm feature has three levels of operation, Disabled, Warning Only and Warning with Brew Lockout, see chart for details.

Alarm Mode

None

Rinse LED will come on 4 hrs prior to the selected time interval and remain on until the Rinse procedure has been performed. The dispenser will continue to serve product.

Rinse LED will come on 4 hrs prior to the selected time interval and remain on until the Rinse procedure has been performed. The dispenser will Lockout and not continue to serve product once the selected time interval has elapsed.

NOTE: The time interval between Rinses is adjustable from 8 to 24 hrs.

The dispenser is shipped with the automated Rinse Alarm disabled, (No Alarm). It is up to the user to determine the Rinse time interval and the level of warning required, based on their application and maintenance procedures. To enable the automated Rinse Alarm feature, refer to RINSE ALARM ? in Programming the Dispenser.

10

34766 050103

 

Rinse Procedure:

1.Open the cabinet door and select Rinse on the Function Selector switch – close the door.

2.Place a 2 Liter (1/2 Gal) container under the Left dispense tip.

3.Activate the Left dispenser until water flow stops automatically, approximately 20 sec.

4.Repeat Steps 2 & 3 for the Right dispense tip.

The Rinse LED will turn OFF, when the Rinse procedure has been satisfied for both sides.

5. Open the cabinet door and select Normal on the Function Selector switch – close the door.

1 5

BIB Empty Lockout Feature

The dispenser can be set to not dispense product when the concentrate BIB is empty. To enable this feature, first calibrate the Empty BIB Threshold (refer to Field Calibrating the Empty BIB Warning). Then enable the BIB Empty Lockout feature (refer to the BIB Empty Lockout menu in Programming the Dispenser). The dispenser will now Lockout dispensing and flash the Right or Left “REFILL LED” corresponding to the empty BIB. Once the BIB has been replaced, PRIME the concentrate line (refer to Priming the Concentrate Lines) and then dispense mixed product until the “REFILL LED” goes out. NOTE: If the dispenser fails to clear the BIB Empty Lockout, repeat the Priming operation a second time to insure the concentrate is flowing properly.

Brew Temperature Lockout Feature

The dispenser can be set to not dispense product if the hot water is not up to the preset READY temperature. To enable this feature set the READY temperature to the minimum allowable dispense temperature. Then enable the Brew Lockout feature, refer to READY TEMP and BREW LOCKOUT, in Programming the Dispenser.

11

34766 042304

 

PROGRAMMING THE DISPENSER

Remove the lower splash guard assembly to access the digital programming module with LCD display. Press the Down Arrow key to inter the programming menu.

Use the Up and Down Arrow keys to scroll through the menu screens.

Select Exit to leave the programming function and return to normal operations. NOTE 1: Flashing menu items indicate which selection is active.

NOTE 2: Values shown below are the factory default values for English units. NOTE 3: Values in [X - X] are the Min. and Max. for that function.

 

MENU SCREEN

ACTION

DESCRIPTION

 

 

 

 

 

 

TANK TEMP XXX

 

UsetheDownArrowKeytoenter

Normal Display for LCA models, (No Chiller)

 

AMBIENT UNIT

 

Programming Functions

 

 

 

 

 

 

 

 

 

 

 

 

 

TANK TEMP XXX

 

UsetheDownArrowKeytoenter

Normal Display for LCC models, (with Chiller)

 

 

 

CABINET TEMP XX

Programming Functions

 

 

 

 

 

 

 

 

 

 

 

 

L DISPENSE RATIO

 

Use the (+) or (-) buttons to

Enter the desired Mix Ratio for the concentrate

(-) 35:1 (+)

 

 

adjust the Mix Ratio

used in the Left dispenser. [20:1 - 100:1]

 

 

 

 

 

 

 

 

 

 

SET LF TUBE SIZE

 

Select tube size.

Enter Pump Tube Size to be used in the Left

1/8

EXIT 3/16

 

 

metering pump, (see Tube Selection Chart)

 

 

 

 

 

 

 

 

 

 

R DISPENSE RATIO

 

Use the (+) or (-) buttons to

Enter the desired Mix Ratio for the concentrate

(-) 35:1 (+)

 

 

adjust the Mix Ratio

used in the Right dispenser. [20:1 - 100:1]

 

 

 

 

 

 

 

 

 

 

SET RT TUBE SIZE

 

Select tube size.

Enter Pump Tube Size to be used in the Right

1/8

EXIT 3/16

 

 

metering pump, (see Tube Selection Chart)

 

 

 

 

 

 

 

 

 

 

FLAVOR GUARD ?

 

Select(YES)toactivate. Select

Select Yes, if you are ready to calibrate the Flavor

 

NO

EXIT YES

 

(NO) to deactivate.

Guard sensor. Select NO, if you do not wish to

 

 

 

 

 

 

use this feature, (see Flavor Guard)

 

 

 

 

 

 

If NO - go to LF DISP VOLUME menu.

LF TASTE OK ?

Select (YES) or (NO)

Select YES, if you have dispensed several cups

NO

EXIT YES

 

and are satisfied with the Left dispenser flavor.

 

 

 

Select NO, if you have not run taste test.

 

 

 

 

 

 

FIND LF TARGET

Place a 16 Oz. (500 mL) cup

Calibrates the Left FlavorGard™ sensor to the

PULL

DISPENSE

under the Left dispense tip, then

current MixProfile. The dispenser will shut OFF

 

 

activate the Left dispenser

automatically when finished.

 

 

 

 

 

RT TASTE OK ?

Select (YES) or (NO)

Select YES, if you have dispensed several cups

NO

EXIT YES

 

and are satisfied with the Right dispenser flavor.

 

 

 

Select NO, if you have not run taste test.

 

 

 

 

 

 

FIND RT TARGET

Place a 16 Oz. (500 mL) cup

Calibrates the Right FlavorGard™ sensor to the

PULL

DISPENSE

under the Right dispense

current MixProfile. The dispenser will shut OFF

 

 

tip, then activate the Right

automatically when finished.

 

 

 

 

dispenser

 

12

34766 042304

 

MENU SCREEN

ACTION

DESCRIPTION

 

 

 

LOCK FLAVOR ?

Select (YES) or (EXIT)

Select YES, to Lock In sensor calibration. NOTE:

EXIT YES

 

Display will return to “Find LF Target” if sensor

 

 

calibration is out of range.

 

 

 

 

 

FLAVORS LOCKED

NONE

Confirms that sensor calibration was in range and

EXIT

 

accepted. Scroll down to continue.

 

 

 

Portion Control Settings for Pull and Hold Dispensers

For Portion Control Dispensers (LCA-2 PC, LCA-2C PC, LCA-2A PC) go to Full Time Portion Control Settings

LF DISP VOLUME (-) 4.0oz (+)

RT DISP VOLUME (-) 4.0oz (+)

Use the (+) or (-) buttons to adjust the Left portion volume

Use the (+) or (-) buttons to adjust the Right portion volume

Full Time Portion Control Settings

Set the volume to be dispensed during a Left Portion controlled dispense to: [0 - 640 Oz.] or [0 - 18.93L]

Set the volume to be dispensed during a Right Portion controlled dispense to: [0 - 640 Oz.] or [0 - 18.93L]

LF DISP VOLUME 1 (-) 4.0oz (+)

LF DISP VOLUME 2 (-) 0.0oz (+)

RT DISP VOLUME 1 (-) 4.0oz (+)

RT DISP VOLUME 2 (-) 0.0oz (+)

WATER DISP VOL 1 (-) 0.0oz (+)

WATER DISP VOL 2 (-) 0.0oz (+)

Use the (+) or (-) buttons to adjust the Normal Left volume

Use the (+) or (-) buttons to adjust the Alternate Left volume

Use the (+) or (-) buttons to adjust the Normal Right volume

Use the (+) or (-) buttons to adjust the Alternate Right volume

Use the (+) or (-) buttons to adjust the Normal Hot Water volume

Use the (+) or (-) buttons to adjustthe AlternateHotWater volume

Set the desired portion control volume to be dispensed during a Normal Left dispense to: [0 - 640 Oz.] or [0 - 18.93L]

Set the desired portion control volume to be dispensed during a Alternate Left dispense to: [0 - 640 Oz.] or [0 - 18.93L]

Set the desired portion control volume to be dispensed during a Normal Right dispense to: [0 - 640 Oz.] or [0 - 18.93L]

Set the desired portion control volume to be dispensed during a Alternate Right dispense to: [0 - 640 Oz.] or [0 - 18.93L]

Set the desired portion control volume to be dispensed during a Normal Hot Water dispense: [0 - 640 Oz.] or [0 - 18.93L]

Set the desired portion control volume to be dispensed during a Alternate Hot Water dispense: [0 - 640 Oz.] or [0 - 18.93L]

13

34766 120105

 

 

MENU SCREEN

ACTION

DESCRIPTION

 

 

 

 

 

 

TANK TEMP 180

 

Use the (+) or (-) buttons to

Sets the water Tank temperature [120 - 200°F]

 

(-) EXIT (+)

 

adjust the target Temp.

or [49 - 93°C]

 

 

 

 

 

 

 

 

 

 

 

READY TEMP 175

 

Use the (+) or (-) buttons to

Sets the hot water Ready temperature. Typically

 

(-) EXIT (+)

 

adjust the target Temp.

set to the minimum desired dispense temp.

 

 

 

 

 

 

 

 

 

 

 

 

CABINET TEMP 65

 

Use the (+) or (-) buttons to

LCC Models Only: Sets the Chilled Cabinet target

 

 

 

(-) EXIT (+)

adjust the target Temp.

temperature [50 - 75°F] or [4 - 24°C]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LF PRODUCT DISP

 

Select (RESET) to clear total

Selecting Reset will clear the Current accumulated

 

.0GAL RESET?

 

 

volume of concentrate dispensed through the Left

 

 

 

 

 

dispenser. Gal (Liters)

 

 

 

 

 

 

 

 

 

 

LF PRODUCT DISP

 

NONE

Displays the Total accumulated volume of

 

.0GAL

 

 

concentrate dispensed through the Left dispenser.

 

 

 

 

 

Not Re-settable. Gal (Liters)

 

 

 

 

 

 

 

 

 

 

RT PRODUCT DISP

 

Select (RESET) to clear total

Selecting Reset will clear the Current accumulated

 

.0GAL RESET?

 

 

volume of concentrate dispensed through the

 

 

 

 

 

Right dispenser. Gal (Liters)

 

 

 

 

 

RT PRODUCT DISP

 

NONE

Displays the Total accumulated volume of

 

.0GAL

 

 

concentrate dispensed through the Right

 

 

 

 

 

dispenser. Not Re-Settable. Gal (Liters)

 

 

 

 

 

The following functions can be Password Protected. If you wish to prevent others from accessing these functions, enter a 4 digit code of your choice. Record your password code [_ _ _ _], as you will need it to access these functions in the future.

 

ENTER PASSWORD

Use the (+) or (-) buttons to

Enter the access Code to view the remaining

(-)

0

(+)

enter password.

functions. Factory Default = 0.

 

 

 

 

 

 

 

 

 

 

 

SET PASSWORD ?

Use the (+) or (-) buttons to

Enter your own Code to prevent access to the

(-)

0

(+)

change the password.

remaining functions. [0 to 9999]

 

 

 

 

 

 

 

 

 

SELECT UNITS

Select the preferred units

Used to select the preferred units of measurement.

 

ENG

EXIT METRIC

 

(Oz., Gal, deg F) or (mL, L, deg C)

 

 

 

 

 

 

 

 

 

CHILLED UNIT ?

Select (YES) or (NO)

LCA Models without Chiller select (NO)

 

NO

EXIT

YES

 

LCC Models with Chiller select (YES)

 

 

 

 

 

 

 

 

 

RINSE ALARM ?

Select (YES) or (NO)

Selecting Yes will enable the Rinse Alarm function,

 

NO

EXIT

YES

 

(see Rinse Alarm)

 

 

 

 

 

 

If NO - go to BIB EMPTY LOCKOUT menu.

14

34766 120105

 

MENU SCREEN

RINSE TIME ?

(-) 12 Hrs (+)

RINSE LOCKOUT ?

NO EXIT YES

BIB EMPTY LOCKOUT NO EXIT YES

BREW LOCKOUT ?

NO EXIT YES

DLY REPEAT DISP (-) 0 SEC (+)

ACTION

DESCRIPTION

Use the (+) or (-) buttons to

Enter the desired time between required Rinse

adjust Rinse Alarm delay

Cycles in hours, [8 - 24 hrs.]

Select (YES) to enable

Select YES to Lockout dispensing until the Rinse

 

Alarm has been cleared. Default is NO

Select (YES) to enable

Select YES to Lockout dispensing until the

 

Concentrate BIB has been replaced. Default is

 

NO

Select (YES) to enable

Select YES to Lockout dispensing until the hot

 

water tank is at READY Temp. Default is NO

Use the (+) or (-) buttons to

Enter the desired time delay before allowing the

adjust the Delay Time

next dispense to take place, [0 - 10 sec.]

The following functions are for diagnostic and troubleshooting purposes and typically do not have to be adjusted. Contact your local service agent for assistance before making changes to these functions.

CAL LEFT SIDE ?

Select (YES) to enable

Selecting Yes will enable the Left Dispenser

EXIT YES

 

Calibration routine, (see Field Calibration before

 

 

attempting to calibrate the dispenser).

 

 

If NO - go to CAL RIGHT SIDE menu.

CAL LEFT PUMP ? PULL DISPENSE

CAL LF PUMP VOL (-) 43mL (+)

CAL LF WTR FLOW ? PULL DISPENSER

CAL LF WTR VOL (-) 36.0OZ (+)

CAL LEFT SIDE ? EXIT YES

CAL RIGHT SIDE ? EXIT YES

Place a 50 mL (#34843.1000) graduated cylinder under the Left dispense tip, then activate the Left Dispenser

Use the (+) or (-) buttons to enter volume collected

Place a 64 Oz. (2000 mL) container under the Left dispense tip, then activate the Left Dispenser

Use the (+) or (-) buttons to enter volume collected

NONE

The Left Pump will dispense concentrate for 20 seconds, then shut off automatically. Collect and measure the concentrate dispensed.

Enter the volume of concentrate measured from the Left Pump in mL, (not Oz.) regardless of Preferred Units selected.

The Left Dispenser will dispense hot water for 20 seconds, then shut off automatically. Collect and measure the water dispensed.

Enter the volume of the water measured from the Left dispenser in Oz. (mL).

Scroll down to bypass this screen.

Select (YES) to enable Selecting Yes will enable the Right Dispenser Calibration routine. Calibration routine, (see Pump Calibration) prior

to calibrating the dispenser.

15

34766 120105

 

MENU SCREEN

ACTION

DESCRIPTION

If NO - skip to next menu.

CAL RIGHT PUMP ? PULL DISPENSER

CAL RT PUMP VOL (-) 43mL (+)

CAL RT WTR FLOW PULL DISPENSER

CAL RT WTR VOL (-) 36.0OZ (+)

CAL RIGHT SIDE ? EXIT YES

Place a 50 mL (#34843.1000) graduated cylinder under the Right dispense tip, then activate the Right Dispenser

Use the (+) or (-) buttons to enter volume collected

Place a 64 Oz. (2000 mL) container under the Right dispense tip, then activate the Right Dispenser

Use the (+) or (-) buttons to enter volume collected

NONE

The Right Pump will dispense concentrate for 20 seconds, then shut off automatically. Collect and measure the concentrate dispensed.

Enter the volume of concentrate measured from the Right Pump in mL(not Oz.) regardless of Preferred Units selected.

The Right Dispenser will dispense hot water for 20 seconds, then shut off automatically. Collect and measure the water dispensed.

Enter the volume of the water measured from the Right dispenser in Oz. (mL)

Scroll down to bypass this screen.

For Portion Control Dispensers (LCA-2 PC, LCA-2C PC, LCA-2A PC) only

CAL HOT WTR FLO ? PULL DISPENSE

CAL HOT WTR VOL (-) 34.0OZ (+)

XXX CAL -> XXX

(-) TankTemp (+)

FlvrGrdRange 10%

(-) EXIT (+)

LfFlvrGrdTargets

RPM XXX-CON XXX

RtFlvrGrdTargets

RPM XXX-CON XXX

Place a 64 Oz. (2000 mL) container under the Hot Water dispense tip, then activate the Hot Water Dispenser

Use the (+) or (-) buttons to enter volume collected

Use the (+) or (-) buttons to adjust temperature reading

Use the (+) or (-) buttons to adjust % value

NONE

NONE

The Hot Water Dispenser will dispense for 20 seconds, then shut off automatically. Collect and measure the water dispensed.

Enter the volume of the water measured from the Hot Water Dispenser in Oz. (mL)

Adjust the display reading to match a calibrated probe inserted next to the Tank Sensor, °F (°C).

Used to set the maximum adjustment the Flavor Guard feature is allowed to make, [3 - 15%].

Displays the Left Dispenser target RPM and Conductance Reading, (Diagnostics Only)

Displays the Right Dispenser target RPM and Conductance Reading, (Diagnostics Only)

16

34766 120105

 

MENU SCREEN

ACTION

 

 

BIB EMPTY -> 500

Use the (+) or (-) buttons to

(-)

EXIT

(+)

adjust empty BIB threshold

 

 

 

 

 

 

XX

REFILL -> 155

Use the (+) or (-) buttons to

(-) EXIT (+)

adjust Refill threshold

 

 

 

 

WTR START DELAY

Use the (+) or (-) buttons to

(-) .15SEC (+)

adjust delay time

 

 

 

 

WTR STOP DELAY

Use the (+) or (-) buttons to

(-) .15SEC (+)

adjust delay time

 

 

 

 

TEST LED’S ?

Select (YES) or (NO)

NO EXIT

YES

 

 

 

 

 

TEST SWITCHES ?

NONE

UseSwitchToTest

 

 

 

 

 

DESCRIPTION

Used to set the Conductance Threshold for the Empty BIB warning. Default is 500

Used to set the Conductance Threshold for the Tank Refill Probe.

Dispense Valve ON Delay. Eliminates weak mix at the beginning of a dispense.

Dispense Valve OFF Delay. Flushes the mix chamber at the end of a dispense.

LED diagnostics. Selecting YES will light all Front Door LED’s.

Switch Diagnostic: Activate switches separately to test. Display will indicate which Switch has been activated. NOTE: Door Interlock switch must be held closed.

TEST REFILL ?

Momentarily depress (YES)

Refill Valve Diagnostic: Press YES to momentarily

 

EXIT YES

 

energize the Solenoid. CAUTION: Inlet Valve will

 

 

 

open and water will flow, if connected and turned

 

 

 

 

 

 

ON.

 

 

 

TEST HEATER ?

Momentarily depress (YES)

Tank Heater Diagnostic: Press YES to momentarily

 

EXIT YES

 

energize the Tank Heater Circuit.

 

 

 

CAUTION: AC power will be applied to the Tank

 

 

 

 

 

 

Heater Circuit.

 

 

 

ENTER ASSET #

Use the (+) or (-) buttons to

Allows the user the option of entering an Asset

(-) 000000 (+)

adjust the ASSET NUMBER

Number. Default is 000000

 

 

 

 

 

 

SERIAL #

NONE

Displays the manufacture’s Serial Number (should

LCA 0000000

 

be identical to the Serial Number on the machine

 

 

 

Data Plate)

 

 

 

 

 

 

FACTORY DEFAULTS

Select (YES) or (NO)

CAUTION: Selecting YES will RESET all

NO

YES

 

Programming Functions to the Factory Default

 

 

 

settings. NOTE: On LCC Models the Chiller will

 

 

 

 

 

 

have to be reset to the ON condition, (see Chilled

 

 

 

Unit programming function).

17

34766 061605

 

LOADING THE CONCENTRATE

1.Thoroughly mix concentrate by vigorously shaking the product Bag-In-Box (BIB).

2.Pull the BIB connector through the hole provided in the box and place it on the drip tray with the connector facing up. (See Fig. 1)

3.Open the dispenser door and locate the appropriate left or right BIB Adapter fitting.

4.Pull the Adapter fitting down and connect it to the BIB. (See Fig. 2)

5.Place the BIB upright in the machine, rotating it into position with the connector facing forward.

6.Rotate the BIB Adapter to avoid sharp bends in the tubing and allow it to be routed between the two pumps.

Refer to the Tube Installation Decal on the door for proper routing. (See Fig. 3)

7.Close the cabinet door.

Fig. 1

Fig. 2

Fig. 3

PRIMING THE CONCENTRATE LINES

1.Open the dispenser door.

2.Load concentrate per instructions in the section titled Loading the Concentrate.

3.Select Prime on the Function Selector Switch and Run on the Mode Selector Switch.

4.Close the dispenser door.

5.Place a container under the appropriate dispense tip.

6.Activate the appropriate dispenser until concentrate flows from the dispense nozzle. Priming may take 5 to 10 seconds.

7.Open the dispenser door, select Normal on the Function Selector Switch, and then close door.

Note: Concentrate may continue to drip out of dispense tip. The user may wish to run a Rinse Cycle (refer to Rinsing) after Priming the dispenser to clean out the remaining concentrate.

7

3

3

18

34766 042304

 

OPERATING THE PULL & HOLD DISPENSER

(Models LCA-2, LCA-2C, LCA-2A, LCC-2, LCC-2C, LCC-2A)

Set the Function Selector Switch to Normal and the Mode Selector Switch to Run.

1.Pull and Hold Dispense Mode (Cup at a time)

a.Place cup on the cup tray beneath the desired dispensing tip. For a large container, flip the cup tray up and place the container on top of the drip tray.

b.Pull and Hold the corresponding dispense handle until the cup or other container is full.

c.Remove cup or container.

2.Portion Dispense Mode (Preset volume dispensing) Refer to Programming Functions on how to set this volume.

a.Place the appropriate size container beneath the desired dispensing tip. For large containers, flip the cup tray up and place the container on top of the drip tray.

b.Momentarily press the Portion Switch. The Portion LED will illuminate for 5 seconds after the Portion Switch is pressed.

c.Momentarily pull the corresponding dispense handle, then release. If the user waits longer than 5 seconds to pull the handle, the dispenser will default back to the Pull & Hold Mode. Portion Dispense Mode can be disabled at any time during the portion dispense by either momentarily pulling the Dispense Handle again or pressing the Stop button.

d.Wait for container to fill and the dispenser to quit dispensing, then remove container.

3.Hot Water Dispense

a.Place container under the hot water dispenser (center of machine). For large containers, flip the cup tray up and place the container on top of the drip tray.

b.Push and hold the Hot Water Switch until the water reaches the desired level, then release.

c.Remove container.

Filling Cambros or other large containers:

The dispenser is designed primarily for cups or other small containers that will fit under the dispense tips. However, it may be used to fill larger containers (up to 2 Gal) by use of an extension hose on the dispense tip. Removing the Flow Restrictors will increase the dispenser flow rate to 2.5 Oz/sec. (74 mL/sec.) and reduce the time to fill larger containers, (see Setting Dispenser Flow Rate.)

Care must be taken to insure that the mixed product flows freely from the dispense tip into the container.

1.Use a 5/8” I.D. or larger, NSF (National Sanitation Foundation) approved hose.

2.Use as short a hose as possible with no loops, bends or kinks in it.

3.Insure that the outlet of the hose is below the dispense tip and that the mixed product flows freely into the container

A properly sized and positioned hose will not run full or back up into the dispense tip. Failure to follow these directions can alter the mix ratio and/or cause flooding of the vent tube.

NOTE: The temperature of the product being dispensed will start to drop after ~2 gal. continuous draw. Recovery time will be dependent on the temperature of the supply water and the voltage at which the heater

coil is being operated.

19

34766 042304

 

 

 

OPERATING THE PRESET PORTION CONTROL DISPENSER

(Models LCA-2 PC, LCA-2C PC, LCA-2A PC)

Set the Function Selector Switch to Normal and the Mode Selector Switch to Run.

Dispensing Preset Portions of Coffee or Hot Water

1.Primary Volume Portion Dispense Mode. (Volume 1) Refer to Programming Functions on how to set this amount.

a.Place cup on the cup tray beneath the desired dispensing tip. For a large container, flip the cup tray up and place the container on top of the drip tray.

b.Momentarily press the appropriate dispense switch. The dispenser will automatically dispense the beverage at the preset amount. Allow the mix chamber to drain at the end of the cycle.

c.Remove cup or container.

2.Alternate Volume Portion Dispense Mode. (Volume 2) Refer to Programming Functions on how to set this volume.

a.Place the appropriate size container beneath the desired dispensing tip. For large containers, flip the cup tray up and place the container on top of the drip tray.

b.Momentarily press the Portion Switch. The Portion LED will illuminate for 5 seconds after the Portion Switch is pressed.

c.Momentarily press the corresponding Dispense Switch. If the user waits longer than 5 seconds to push the switch, the dispenser will default back to the Primary Volume preset amount. Alternate Portion Dispense Mode can be disabled at any time during the portion dispense by either momentarily pushing the Dispense Switch again or pressing the Stop button.

d.Wait for the container to fill and the dispenser to quit dispensing, then remove the container.

Push and Hold Dispensing of Coffee or Hot Water

Push and Hold Dispense Mode. See Programming Functions on how to set the Preset Volume to Zero.

a.Place cup on the cup tray beneath the desired dispensing tip. For a large container, flip the cup tray up and place the container on top of the drip tray.

b.Push and hold the corresponding dispense switch until the container is full.

c.Remove cup or container.

Filling Cambros or other large containers:

The dispenser is designed primarily for cups or other small containers that will fit under the dispense tips. However, it may be used to fill larger containers (up to 5 Gal) by use of an extension hose on the dispense tip. Removing the Flow Restrictors will increase the dispenser flow rate to 2.5 Oz/sec. (74 mL/sec.) and reduce the time to fill larger containers, (see Setting Dispenser Flow Rate.)

Care must be taken to insure that the mixed product flows freely from the dispense tip into the container.

1.Use a 5/8” I.D. or larger, NSF (National Sanitation Foundation) approved hose.

2.Use as short a hose as possible with no loops, bends or kinks in it.

3.Insure that the outlet of the hose is below the dispense tip and that the mixed product flows freely into the container

A properly sized and positioned hose will not run full or back up into the dispense tip. Failure to follow these directions can alter the mix ratio and/or cause flooding of the vent tube.

NOTE: The temperature of the product being dispensed will start to drop after ~2 gal. continuous draw. Recovery time will be dependent on the temperature of the supply water and the voltage at which the heater coil is being operated.

20

34766 120105

 

CLEANING & PREVENTATIVE MAINTENANCE

General Cleaning and Sanitizing Procedures

Note: The BUNN® Liquid Coffee Dispenser incorporates a “user selectable” rinse reminder feature, which lights the Rinse LED on the front panel and disables dispensing when it is time to rinse. See Programming Functions to activate this feature.

Daily: RINSING

1.Open the dispenser door.

2.Select Rinse on the Function Selector Switch and Run on the Mode Selector Switch.

3.Close the dispenser door.

4.Place a 1/2 gal (2 liter) container under the appropriate dispense nozzle or nozzles.

5.Activate the Dispenser of the appropriate side or sides for approximately twenty seconds or until the hot water is clear or has no concentrate coloring in it.

6.Open the dispenser door, select Normal on the Function Selector Switch, and then close door.

Note: To clear the “Rinse” alarm, activate each dispenser until the flow stops automatically (approx. 20 seconds for each tip). The “Rinse” alarm LED will turn off when the Rinse Procedure has been satisfied for both sides.

Daily: PARTS WASHING

1.Remove and wash the drip tray, drip tray cover, and cup tray in a mild detergent solution. Rinse thoroughly.

2.Wipe splash panel, area around dispense nozzles, door, and cabinet with a clean damp cloth.

Weekly: SANITIZING

1.Open the dispenser door.

2.Select Prime on the Function Selector Switch and Run on the Mode Selector Switch.

3.Remove the bag connector from the product box and disassemble or prop open the internal valve to allow free flow of product through the connector. NOTE: Cutting the mating fittings from an empty bag makes an excellent “free flowing” connector for this purpose.

4.Place the bag connector into a one-gallon (3.8 liter) container of warm soapy tap water 140°F (60°C).

5.Place an empty container under dispense tip and activate the corresponding Dispenser until the clean soapy water is dispensed from the dispense tip.

6.Repeat steps 4 and 5 with warm tap water 140°F (60°C) to rinse the soapy water from the pump tubing. Continue dispensing until the water is clear, and no soapy water is being dispensed.

7.Prepare 2.5 gallons (9.46L) of sanitizing solution by dissolving 1 packet of Kay 5 sanitizer into 2.5 gallons (9.46L) of 120°F (48.9°C) water to ensure 100 ppm of available chlorine.

8.Again, repeat steps 4 and 5 with the sanitizing solution. Once sanitizing solution is being dispensed, stop dispensing and allow the solution to sit for 5 minutes.

9.Repeat step 6 to flush out the sanitizing solution from the pump tubing.

10.Remove the mating connector from the bag connector.

11.Reattach the bag connector to product box.

12.Select Normal on the Function Selector Switch and Run on the Mode Selector Switch.

13.Activate the Dispenser until concentrate/water mixture appears. Then dispense one 12 ounce (354.9 ml) glass of concentrate/water mixture and discard.

14.Repeat steps 1 through 13 for other dispense head.

15.Wipe internal and external surfaces with a clean, damp cloth.

21

34766 042304

 

REPLACING THE PUMP TUBING

The pumps and tubing used in the dispenser are designed to give maximum performance and long life. However, the tubes are a wear item and must be replaced periodically. How long the tubes last is dependent on usage and properties of the concentrate. Excessive wear will reduce the output of the pumps resulting in a weak mixed beverage. Bunn-O-Matic recommends replacing the Pump Tubing a minimum of once every 6 months or sooner if warranted.

Refer to the Tube Replacement Instruction on the Cabinet door for details.

1.Rinse the pump tubing with warm tap water (Refer to steps 1 - 5 of the Weekly Sanitizing instructions) prior to removing the tubes to avoid concentrate spills.

2.Loosen the thumbscrew securing the tubing retainer plate to the pump housing. Set it and the retainer plate aside.

3.Depress the tension screw and remove it from the notch in the pump housing, releasing the spring tension on the pump band.

4.Open the compression band and gently pull the pump tube from around the pump’s rotor.

5.Inspect the pump bands for signs of wear. Replace if necessary.

6.Apply lubricant (BUNN-O-MATIC part number M2531.0001) to the new pump tubing’s rotor side.

7.Insert the tube onto the mix chamber port, then wrap the new tubing around the pump rotor, making sure that the elbow and clamps end up on the bottom side of the pump housing.

8.Depress the tension screw and insert it in the notch in the pump body, reapplying spring tension on the pump band.

9.Replace the tubing retainer plate and tighten the thumbscrew.

10.Repeat steps 1 through 9 for the other pump.

Thumbscrew

 

 

 

 

 

 

 

 

 

 

 

 

 

Tension

 

 

 

 

2.0”

 

 

 

 

 

2.0”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Screw

 

Lubricate between arrows

 

 

Remove Retaining Plate Release Spring Tension

Remove Tubing

 

 

Lubricate New Tube

Tension Screw

 

Tube Clamp

 

Install New Tubing

Completed Installation

22

34766 112502

 

DRAINING THE HOT WATER TANK

CAUTION: The dispenser must be disconnected from the power source throughout these steps.

1.Disconnect the dispenser from the power source.

2.Shut off and disconnect the incoming water supply.

3.Remove the front splash panel.

4.Pull out drain tube to empty into a sink or a container with a minimum of five-gallon capacity.

5.Make sure drain clamp is closed. Then, remove drain plug.

6.Direct tube into sink or container and open drain clamp. Continue draining tank until ALL of the water is out. Be very careful with the draining water because it can be very hot.

7.Close drain clamp, insert drain plug, place drain tube back into machine, and replace splash panel.

Note: The dispenser must be refilled using the Initial Fill & Heat steps before reconnecting the power source.

23

34766 112502

 

Troubleshooting

A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department.

Only qualified service personnel should perform inspection, testing, and repair of electrical equipment.

Shorting the terminals or the application of external voltages to electronic components may result in component or circuit board failure.

Intermittent operation of electronic circuit boards is unlikely. board failure will normally be permanent. If an intermittent condition is encountered, the cause will likely be a switch contact or a loose wire connection at a terminal or crimp.

Solenoid removal requires interrupting the water supply to the valve. Damage may result if solenoids are energized for more than ten minutes without a supply of water.

The use of two wrenches is recommended whenever plumbing fittings are tightened or loosened. This will help avoid twists and kinks in the tubing.

Make certain that all plumbing connections are sealed and all electrical connections are tight and isolated.

This dispenser is heated at all times. Keep away from combustibles.

WARNING:

Exercise extreme caution when servicing electrical equipment.

Disconnect the brewer from the power source when servicing, except when electrical tests are specified. The red “Power LED” on the door indicates that the unit is connected to AC Power.

Follow recommended service procedures.

Replace all protective shields or safety notices.

Front Panel LED Display Messages

Power LED “OFF”

Dispenser Not plugged in.

Check Power Cord

No AC Power

AC Circuit Breaker OFF

Check the AC Power Circuit Breaker

 

 

Service Required

 

 

 

 

 

 

Ready LED “OFF”

Usage has exceeded the

Check Tank Temp Setting

Water Temp. Too Low

capacity of the Tank Heater

Check Ready Temp. Setting

 

 

Service Required: Change the Supply Voltage,

 

 

see Optional Field Wiring

 

 

 

 

 

 

Rinse LED “ON”

Rinse Cycle Required

Rinse Dispenser, see Rinse Procedure

Rinse Timer

 

 

 

 

 

 

 

 

Rinse LED “FLASHING”

Dispenser Locked Out

Rinse Dispenser, see Rinse Procedure

Rinse Lockout Enabled

Rinse Cycle Required

 

 

 

 

 

 

 

Portion LED “ON”

Alternate Portion Dispenser

Activate the Dispenser within 5 sec. to

Portion Dispense

Volume #2 has been selected

dispense the pre-selected volume.

Enabled

 

 

 

 

 

24

34766 042304

 

Troubleshooting (Continued)

Left Refill LED “ON”

Concentrate BIB is Empty.

Replace BIB, see Loading the Concentrate

Left BIB Empty

BIB Not properly connected

Check BIB Connector Fittings

 

Tubing kinked or blocked

Check Tubing Installation

 

Empty BIB warning set too high

Check Threshold, see Field Calibrating the

 

 

Emoty BIB Warning

 

 

 

 

 

 

Right Refill LED “ON”

Concentrate BIB is Empty.

Replace BIB, see Loading the Concentrate

Right BIB Empty

BIB Not properly connected

Check BIB Connector Fittings

 

Tubing kinked or blocked

Check Tubing Installation

 

Empty BIB Warning set too high

Check Threshold, see Field Calibrating the

 

 

Empty BIB Warning

 

 

 

 

 

 

Left Refill LED

Left Dispenser will not operate

Replace BIB, see loading the Concentrate

“FLASHING”

 

 

Empty BIB Lockout

 

 

Enabled

 

 

 

 

 

 

 

 

Left Refill LED

Left Dispenser will not operate

Replace BIB, see loading the Concentrate

“FLASHING”

 

 

Empty BIB Lockout

 

 

Enabled

 

 

 

 

 

All LED’s “FLASHING”

The Dispenser has detected an

Fault Detected

Internal Fault

Remove the lower splash guard to view the Fault message, See Diagnostics. After the fault has been repaired or corrected - Hold the “Stop” button for 10 seconds to clear the message.

25

34766 102103

 

Troubleshooting (Continued)

Dispenser Diagnostics-LCD Display

Screen Displayed

 

Possible Cause

Troubleshooting Procedures

 

 

 

 

 

 

LF TARGET RPM

1.

The Tube Size selected for the Left

Refer to “Selecting the Correct Pump

TOO HIGH !!

 

Hand Dispenser is too small for the

Tubing” section of the manual.

 

 

 

 

application.

 

 

 

 

 

 

 

 

 

 

 

 

TUBE TOO SMALL

2.

The Ratio selected for the Left Hand

Refer to recommended Dispense Ratio

CHECK DISP RATIO

 

Dispenser is not correct for the

on the product label.

 

 

 

 

application.

 

 

 

 

 

 

 

RT TARGET RPM

1.

The Tube Size selected for the Right

Refer to “Selecting the Correct Pump

TOO HIGH !!

 

Hand Dispenser is too small for the

Tubing” section of the manual.

 

 

 

 

application.

 

 

 

 

 

 

 

 

 

 

 

 

TUBE TOO SMALL

2.

The Ratio selected for the Right

Refer to recommended Dispense Ratio

CHECK DISP RATIO

 

Hand Dispenser is not correct for the

on the product label.

 

 

 

 

application.

 

 

 

 

 

 

 

LF TARGET RPM

1.

The Tube Size selected for the Left

Refer to “Selecting the Correct Pump

TOO LOW !!

 

Hand Dispenser is too large for the

Tubing” section of the manual.

 

 

 

 

application.

 

 

 

 

 

 

 

 

 

 

 

 

TUBE TOO LARGE

2.

The Ratio selected for the Left Hand

Refer to recommended Dispense Ratio

CHECK DISP RATIO

 

Dispenser is not correct for the

on the product label.

 

 

 

 

application.

 

 

 

 

 

 

 

RT TARGET RPM

1.

The Tube Size selected for the Right

Refer to “Selecting the Correct Pump

TOO LOW !!

 

Hand Dispenser is too large for the

Tubing” section of the manual.

 

 

 

 

application.

 

 

 

 

 

 

 

 

 

 

 

 

TUBE TOO LARGE

2.

The Ratio selected for the Right

Refer to recommended Dispense Ratio

CHECK DISP RATIO

 

Hand Dispenser is not correct for the

on the product label.

 

 

 

 

application.

 

 

 

 

 

 

 

LEFT BIB EMPTY!

1.

Concentrate BIB is Empty.

Replace BIB, see loading the Concentrate

 

 

 

2.

BIB Not properly connected.

Check BIB Connector Fittings

REPLACE PRODUCT

3.

Tubing kinked or blocked.

Check Tubing installation

CHECK THRESHOLD

4.

Empty BIB Warning set too high.

Check Threshold, see Field Calibrating

 

 

 

 

 

the Empty BIB Warning

 

 

 

 

 

 

RIGHT BIB EMPTY!

1.

Concentrate BIB is Empty.

Replace BIB, see loading the Concentrate

 

 

 

2.

BIB Not properly connected.

Check BIB Connector Fittings

REPLACE PRODUCT

3.

Tubing kinked or blocked.

Check Tubing installation

CHECK THRESHOLD

4.

Empty BIB Warning set too high.

Check Threshold, see Field Calibrating

 

 

 

 

 

the Empty BIB Warning

 

 

 

 

 

 

26

34766 011604

 

Troubleshooting (Continued)

Screen Displayed

 

Possible Cause

 

Troubleshooting Procedures

 

 

 

 

 

 

 

 

OVERFLOW CUP

1.

Refill valve stuck open

 

Service Required

FULL. EMPTY CUP

2.

Faulty refill probe

 

Service Required

 

 

 

 

 

 

 

 

 

 

 

3.

Faulty overflow switch

 

Service Required

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEATING TIME TOO

1.

Tank Heater failure

 

Service Required

LONG

2.

Triac failure

 

Service Required

 

 

 

 

 

 

CHECK HEATING

 

 

 

 

CIRCUIT

3.

Tank Temp. sensor failure

 

Service Required

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FILL TIME TOO LONG

1.

Water shut off to dispenser

 

Check water supply shut-off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHECK WATER SUPPLY

2.

Inlet Solenoid Valve failure

 

Service Required

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TANK TEMP SENSOR

1.

Corresponding Temperature

Sensor

Service Required

OUT OF RANGE

 

Probe wire(s) broken or disconnected

 

CHECK

 

 

 

 

 

 

 

 

FOR BAD

 

 

 

 

CONNECTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COOL TEMP SENSOR

1.

Corresponding Temperature

Sensor

Service Required

OUT OF RANGE

 

Probe wire(s) broken or disconnected.

 

CHECK

 

 

2.

Product cabinet temperature too low.

Service Required

 

FOR BAD

CONNECTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EVAP TEMP SENSOR

1.

Corresponding Temperature

Sensor

Service Required

OUT OF RANGE

 

Probe wire(s) broken or disconnected.

 

CHECK

 

 

 

 

 

 

 

FOR BAD

2.

Evaporator temperature too low.

Service Required

CONNECTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

TANK TEMP SENSOR

1.

Corresponding Temperature

Sensor

Service Required

OUT OF RANGE

 

Probe wire(s) shorted to housing, or to

 

 

 

 

 

 

 

each other.

 

 

CHECK WIRE FOR

 

 

 

 

SHORTS

 

 

 

 

 

 

 

 

 

 

 

 

 

COOL TEMP SENSOR

1.

Corresponding Temperature

Sensor

Service Required

OUT OF RANGE

 

Probe wire(s) shorted to housing, or

 

 

 

 

 

 

 

to each other.

 

 

CHECK

WIRE FOR

 

 

 

 

SHORTS

2.

Product cabinet temperature too high.

Service Required

 

 

 

 

 

 

 

 

 

27

34766 011604

 

Troubleshooting (Continued)

Screen Displayed

 

Possible Cause

Troubleshooting Procedures

 

 

 

 

 

 

EVAP TEMP SENSOR

1.

Corresponding Temperature Sensor

Service Required

OUT OF RANGE

 

Probe wire(s) shorted to housing, or

 

 

 

 

 

to each other.

 

CHECK WIRE FOR

 

 

 

SHORTS

2.

Evaporator temperature too high.

Service Required

 

 

 

 

 

 

 

 

 

 

 

 

LEFT PUMP FAULT!

1.

Motor failure

Service Required

CHK PUMP WIRING

2.

RPM Sensor failure

Service Required

 

 

 

CHK RPM SENSOR

 

 

 

CHK TUBING AREA

 

 

 

 

 

 

 

 

 

RT PUMP FAULT!

1.

Motor failure

Service Required

CHK PUMP WIRING

2.

RPM Sensor failure

Service Required

 

 

 

CHK RPM SENSOR

 

 

 

CHK TUBING AREA

 

 

 

 

 

 

 

 

 

COOLER FAULT!

1.

Cabinet circulating fan failure

Service Required

EVAP TEMP TOO HI

2.

Ice build up on evaporator coils

Service Required

 

 

 

CHECK EVAP FAN

 

 

 

CHK EVAP SENSOR

3.

Evaporator sensor failure

Service Required

 

 

 

 

 

 

 

 

 

 

 

 

COOLING TIME

1.

Air intake filter clogged

Clean Air Filter

TOO LONG

2.

Wiring failure

Check wiring harness for breaks,

 

 

 

CHECK

AIR FILTER

 

 

shorts, open connectors

CHECK COOLING UNIT

3.

Compressor failure

Service Required

 

 

 

 

 

 

 

COND PROBE FAULT

1.

Tube leaking

Check pump & tubing for proper

CHECK COND PROBES

 

 

installation

 

 

 

2.

Dispense switch failure

Service Required

CHK DISP SWITCHES

 

 

 

CHK CONNECTIONS

3.

Dispense valve leaking

Service Required

 

 

 

 

 

 

JUMPER FAULT!

1. Invalid wire harness configuation

Service Required

CONFIG NOT VALID

 

 

 

CHECK J-18

ON CONTROL BOARD

28

34766 010407

 

Field Calibration of the Concentrate Pumps / Dispenser Flow Rates

The factory set Default Values for the Pump & Dispenser Flow Rates are very accurate and typically do not need to be field calibrated. However, if the mix ratio accuracy is ever in question, this procedure can be used to recalibrate the unit in the field.

Equipment Required:

50 to 100 ml graduated cylinder, with 1 ml graduations. 64 Oz (2000 ml) graduated container.

Remove the lower splash guard assembly to access prior to starting this procedure

NOTE: You can calibrate either the Concentrate Pump or the Dispenser Flow Rate independently. Simply scroll through the menu screen to the desired section and perform only those steps.

Calibrating the Left Side Dispenser

Concentrate Pump Calibration

1.Select PRIME on the Function Selector Switch. (refer to Priming the Concentrate Lines).

2.Place a container under the Left Dispense Tip and prime the concentrate lines until a steady stream of concentrate comes out the tip (approximately 10 seconds).

3.Stop the Priming and allow the tip to stop dripping. Discard the concentrate collected.

4.Select NORMAL on the Function Selector Switch.

5.Locate the programming module and use the Arrow Down key to scroll through LCD screens until CAL LEFT SIDE appears and press the YES button.

6.The CAL LEFT PUMP menu screen will be displayed. Place a 50 ml graduated cylinder under Left Dispense Tip and activate the Left Dispenser momentarily. The dispenser will run the Left Concentrate Pump for 20 seconds and then shut OFF automatically.

7.Keep the graduated cylinder under dispense tip until all the concentrate has dripped out.

8.Measure the volume of concentrate collected in the graduated cylinder.

Acceptable ranges for the volume collected

Tubing Size

Volume Collected

3/16” tubing

40

- 47 ml.

1/8” tubing

17

- 22 ml

9.If the amount collected is not within the acceptable range, empty the graduated cylinder and repeat STEPS 6 – 8.

10.If the amount collected is still not within range, replace the pump tubing with a new Tube Kit, (refer to the Tube Replacement Instructions).

11.When satisfied with the volume of concentrate collected, press the Down Arrow Key

12.The CAL LF PUMP VOL menu screen will be displayed. Use the (-) / (+) keys to adjust number displayed to the amount measured in STEP 8.

(Continued Next Page)

29

34766 042304

 

Field Calibration of the Concentrate Pumps / Dispenser Flow Rates

(Continued)

Dispenser Flow Rate Calibration

13.Press Down Arrow Key to display the CAL LF WTR FLO menu screen.

14.Place a 64 Oz (2000 ml) graduated container under Left Dispense Tip and Pull the Left Dispense Handle momentarily. The dispenser will dispense water for 20 seconds and then shut OFF automatically.

15.Keep the graduated container under dispense tip until all the water stops dripping.

16.Measure the volume of water collected in the graduated container.

Acceptable ranges for the volume collected

_____Dispenser Flow Rate___________

____Volume Collected____

1.8 Oz/sec (53 ml/sec) w/ flow restrictor

32

- 38

Oz, (946 - 1124 ml)

2.5 Oz/sec (74 ml/sec) w/o flow restrictor

46

- 52

Oz ,(1360 - 1538 ml)

17.If the amount collected is not within the acceptable range, empty the graduated container and repeat STEPS 14 – 16

18.If the amount collected is still not within range, inspect the dispense valves, tubing and mix chamber for lime, kinks or other obstructions.

19.When satisfied with the volume of concentrate collected, press the Down Arrow Key.

20.The CAL LF WTR VOL screen will be displayed. Use the (-) / (+) keys to adjust number displayed to the amount measured in STEP 16.

21.Press Down Arrow Key again to exit the CAL LEFT SIDE functions.

Calibrating the Right Side Dispenser

Repeat STEPS 1-21 above for the “CAL RIGHT SIDE” menus.

Field Calibrating the Hot Water Flow Rate

1.Locate the programming module and use the Arrow Down key to scroll through the LCD screen until “CAL HOT WTR FLO?” appears.

2.Place a 64 Oz (2000 ml) graduated container under Hot Water Tip and press the hot water switch. The unit will dispense Hot Water for 20 seconds and then shut OFF automatically. Keep the graduated container under the dispense tip until all the water stops dripping.

3.Measure the volume of water collected in the graduated container. The acceptable range for the volume collected is 32 - 38 Oz. (946 - 1124 ml).

4.If the amount collected is not within the acceptable range, empty the container and repeat steps 2 & 3.

5.If the amount collected is still not within range, inspect the hot water valve, tubing and fittings for lime, kinks, or other obstructions.

6.When satisfied with the volume of concentrate collected, press the Down Arrow Key.

7.The “CAL HOT WTR VOL” screen will be displayed. Use the (-) / (+) keys to adjust number displayed to the ammount measured in step 3.

8.Press Down Arrow Key again to exit this function.

30

34766 120105

 

Field Calibrating the Empty BIB Warning

The dispenser will automatically turn on the Left or Right “REFILL LED”, see Operating Controls and Interface, when the corresponding BIB is Empty. The Refill message is triggered when the FlavorGardTM sensor reading drops below the minimum setting. The factory set minimum is 500 and should be correct for most locations. However, in some areas the hardness of the local water supply may effect this reading. If the Refill message doesn’t come on when the BIB is empty or the message comes on too early and there is still concentrate left in the BIB, use the following procedure to find the correct Empty BIB threshold.

Calibrating The Empty BIB Threshold

1.Remove the lower splash guard assembly to access the digital programming module with LCD display.

2.Open the cabinet door and set the Function Switch to the “Rinse” position. Close the door.

3.Place a large container under the Left dispenser tip, then activate and hold the left dispenser.

4.Dispense long enough to rinse all the concentrate out of the mix chamber and for the Conductance reading to stabilize and stop dropping.

5.Record the nominal Conductance value displayed. (NOTE: It is typical for this value fluctuate (+/- 25) points about the nominal value}. This is the conductance reading of the water in your area.

6.Repeat steps 3, 4 & 5 for the Right dispenser.

7.Add 100 points to the larger of the Left or Right side Conductance value. This is the new Empty BIB threshold value for your dispenser.

8.Enter this new value into the Empty BIB Alarm threshold, see Programming the Dispenser.

31

34766 120105

 

 

 

 

 

 

 

 

 

 

SCHEMATIC WIRING DIAGRAM

 

 

 

 

 

 

 

 

 

 

 

 

 

L1

 

 

 

 

LCA-2/LCA-2, PC/LCA-2C/LCA-2C, PC/LCC-2/LCC-2C

 

 

 

N (120V 2-Wire)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N (120/208-240V 3-Wire)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GRN

 

L2 (120/208-240V 3-Wire)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L2 (208-240V 2-Wire)

 

 

 

 

 

 

BLK-14

 

 

 

 

 

 

 

 

 

 

 

 

LIMIT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW. & THERMOSTAT

 

 

 

 

THERMOSTAT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TRIAC

 

TANK HEATER

BLK-14 1

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED-14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED-14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK-14

BLU-14

 

 

BLU-14

 

 

 

 

RED-14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TUBE

 

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TAN

 

 

 

 

 

 

PORTION

 

 

 

 

 

 

 

 

 

 

 

WARMER

 

RED

 

 

 

UNIVERSAL

 

 

 

 

 

 

 

CONTROL

 

 

 

 

OVERFLOW

 

 

 

 

 

 

 

BLK

 

 

POWER SUPPLY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TUBE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PROTECTION SW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

RED

WHI/GRY

 

 

 

WARMER

 

 

BLK

 

 

WHI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-V

N(L2)

 

 

 

 

 

 

 

DOOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+V

L(L1)

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHI/GRY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GRN

 

 

 

 

 

 

 

 

 

 

 

 

RED/BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-V

GRN

 

 

 

 

 

 

 

 

 

 

 

RED

SOL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+V

 

 

 

 

 

 

 

 

 

 

 

 

 

HOT WATER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TOUCHPAD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

SOL

 

BRN/BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RIGHT DISP

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES (+)

3

 

 

 

 

 

 

TAN BLK

WHI

RED GRN

BLK

WHI

GRY ORN BLK BLK

 

 

 

 

 

RED

 

 

BRN/WHI

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

SOL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EXIT

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHI/BLU

 

 

 

 

LEFT DISP

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

J2-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO (-)

 

 

 

 

 

 

J1-1

J1-4

 

J2 -8

J15-1

J15-4

J3-1

 

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

SOL

 

BLU/BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHI/RED

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REFILL

 

 

 

 

 

 

LEFT RPM

 

 

 

 

J14-1

 

 

 

 

 

J3-6

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SENSOR

 

GRN

BLU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

RED

 

 

 

 

 

 

C

 

 

 

J4-1

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED/BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RIGHT RPM

BLK

BLK

 

 

 

 

 

 

O

 

 

 

 

BRN/WHI

 

 

 

 

 

 

 

 

 

 

 

 

SENSOR

 

GRN

VIO

 

 

 

J14-7

 

 

 

 

 

BRN/BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VIO

 

 

 

 

 

 

J4-5

WHI/GRY

 

 

 

 

 

 

 

 

 

 

 

 

LEFT

 

 

 

 

 

 

J7-1

 

T

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK

RED

 

 

 

 

 

BLU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

 

BLU/BLK

 

 

 

 

 

 

 

 

 

 

 

 

PUMP

 

 

WHI/YEL

 

 

RED

 

 

 

 

 

 

J5-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YEL

 

 

 

YEL

 

 

 

O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ORN

J7-5

 

L

 

 

 

J5-3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK

RIGHT

RED

 

 

 

 

 

BLK

 

 

 

P

 

 

 

J16-1

BLU

 

 

 

 

 

 

 

 

 

 

 

 

PUMP

 

 

ORN

 

 

 

RED

 

 

 

 

 

 

ORN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHI/ORN

 

 

WHI/ORN

 

 

 

 

 

 

 

WHI/ORN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHI/YEL

J7-10

 

B

 

 

 

 

WHI/YEL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J16-5

PNK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

O

 

 

 

VIO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J8-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J8-3

 

R

 

 

 

 

BLK

 

 

 

 

 

 

 

 

 

BLK ORN

 

 

 

 

 

 

 

 

GRN

 

J18-1

 

D

 

 

 

 

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GRN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J16-12

BLK

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P

 

WHI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

BLK

 

 

 

 

 

 

 

GRN

 

J18-6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHI/YEL

 

BLK

WHI/ORN

BLK

GRN

 

 

 

 

 

 

 

 

 

DISPENSERS WITH

20

 

15

10

 

5

 

1

 

 

 

 

 

t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PORTION CONTROL

J6-

 

J6-

J6-

 

J6-

 

J6-

 

 

 

 

LEFT

 

 

RIGHT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONDUCTANCE

 

CONDUCTANCE

 

 

 

 

 

 

 

 

 

 

 

 

GRN GRN/WHI

BLU/WHI BLU/BLK

ORN GRN/BLK WHI/BLK

WHI RED/BLK RED/WHI ORN/BLK WHI/GRY

WHI/VIO WHI/YEL TAN RED

 

BLK

 

 

 

 

SENSOR

 

SENSOR

 

 

 

LF DISP. SW.

 

S

J1-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLU/WHI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I

 

 

RED/BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T

 

 

GRN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

J1-5

 

ORN/BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

 

 

 

 

 

 

 

 

 

 

 

 

 

RED WHI/BLU

 

 

 

WHI/RED BLK

 

 

 

 

 

 

 

 

 

GRN/WHI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK BLU

 

 

 

 

 

 

 

N

 

 

BLK

 

 

 

 

 

 

 

 

 

 

BLK VIO

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L

 

 

RED/WHI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RT DISP. SW.

 

E

J1-10

 

BLU/BLK

 

 

 

 

 

 

 

 

 

 

BLK WHI

 

 

 

 

 

RED BLK

WHI WHI

 

 

 

 

 

 

 

D

 

 

RED

 

 

 

 

 

 

 

 

 

 

 

RED BLK

 

 

 

 

 

 

 

 

 

 

B

 

 

GRN/BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

O

 

 

WHI/BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

 

 

 

 

 

 

A

 

 

ORN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK

 

 

 

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

 

 

 

 

HEAT SINK

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PELTIER

 

 

 

 

 

 

 

 

 

 

 

 

WHI

 

 

 

 

 

 

 

 

 

 

 

THERMISTOR

 

 

RED BLK

 

 

 

 

 

 

 

 

 

J1-16

 

 

 

 

 

 

 

 

 

 

 

 

t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SELECTOR

 

 

SELECTOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SWITCH

WHI/GRY

SWITCH

WHI/YEL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NITE

 

 

RINSE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK

 

 

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RUN

WHI/VIO

 

PRIME

TAN

 

 

 

 

 

COOLING CABINET

t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CABINET

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120 VOLTS AC 2 WIRE

 

 

 

 

 

BLK

 

 

 

 

 

 

 

 

 

 

 

THERMISTOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120/208-240 VOLTS AC 3 WIRE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

208-240 VOLTS AC 2 WIRE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SINGLE PHASE 50/60HZ

34641.0000J 09/06

© 2002 BUNN-O-MATIC CORPORATION

 

 

 

LLC Models only

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Models without Master ON/OFF Switch

32

34766 010407

 

 

 

 

 

 

 

 

 

 

 

 

SCHEMATIC WIRING DIAGRAM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LCA-2/LCA-2, PC/LCA-2C/LCA-2C, PC/LCC-2/LCC-2C

L1

 

 

N (120V 2-Wire)

 

 

 

 

 

 

 

 

 

 

 

BLK-14

 

RED-14

L2 (208-240V 2-Wire)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MASTER ON/OFF

 

 

 

 

GRN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SWITCH

 

 

 

 

 

 

 

 

 

 

 

BLK-14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LIMIT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW. & THERMOSTAT

 

 

 

THERMOSTAT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TRIAC

 

 

TANK HEATER

BLK-14 1

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED-14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK-14

 

 

BLU-14

 

 

BLU-14

 

 

 

 

RED-14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

4

 

 

 

 

 

 

 

 

 

 

TUBE

 

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TAN

 

 

 

 

 

 

 

PORTION

 

 

 

 

 

 

 

 

 

 

WARMER

 

RED

 

 

 

UNIVERSAL

 

 

 

 

 

 

 

 

 

CONTROL

 

 

 

OVERFLOW

 

 

 

 

 

 

 

BLK

 

 

POWER SUPPLY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TUBE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PROTECTION SW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

RED

WHI/GRY

 

 

 

WARMER

 

 

BLK

 

 

WHI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-V

N(L2)

 

 

 

 

 

 

 

 

 

DOOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+V

L(L1)

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHI/GRY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GRN

 

 

 

 

 

 

 

 

 

 

 

 

RED/BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-V

GRN

 

 

 

 

 

 

 

 

 

 

 

 

RED

SOL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HOT WATER

 

 

 

 

 

 

TOUCHPAD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

SOL

BRN/BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RIGHT DISP

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES (+)

3

 

 

 

 

 

 

 

TAN BLK

WHI

RED GRN

BLK

WHI

GRY ORN BLK BLK

 

 

 

 

RED

 

BRN/WHI

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

SOL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EXIT

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHI/BLU

 

 

 

LEFT DISP

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

J2-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO (-)

 

 

 

 

 

 

 

J1-1

 

J1-4

 

J2 -8

J15-1

J15-4

J3-1

 

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

SOL

BLU/BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHI/RED

 

 

 

 

 

 

 

 

 

 

 

 

RED

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REFILL

 

 

 

 

 

 

 

LEFT RPM

 

 

 

 

 

 

J14-1

 

 

 

 

 

J3-6

BLK

 

 

 

 

 

 

 

 

 

 

 

 

BLK

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SENSOR

 

GRN

BLU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

RED

 

 

 

 

 

 

 

 

C

 

 

 

J4-1

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED/BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RIGHT RPM

BLK

BLK

 

 

 

 

 

 

 

 

O

 

 

 

 

BRN/WHI

 

 

 

 

 

 

 

 

 

 

 

SENSOR

 

GRN

VIO

 

 

 

 

 

J14-7

 

 

 

 

 

BRN/BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VIO

 

 

 

 

 

 

 

J4-5

WHI/GRY

 

 

 

 

 

 

 

 

 

 

 

LEFT

 

 

 

 

 

 

 

J7-1

 

 

T

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK

RED

 

 

 

 

 

 

BLU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

 

BLU/BLK

 

 

 

 

 

 

 

 

 

 

 

PUMP

 

 

WHI/YEL

 

 

 

RED

 

 

 

 

 

 

 

J5-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YEL

 

 

 

 

YEL

 

 

 

 

O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ORN

 

J7-5

 

 

L

 

 

 

J5-3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK

RIGHT

RED

 

 

 

 

 

 

BLK

 

 

 

 

P

 

 

 

J16-1

BLU

 

 

 

 

 

 

 

 

 

 

 

PUMP

 

 

ORN

 

 

 

 

RED

 

 

 

 

 

 

 

ORN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHI/ORN

 

 

WHI/ORN

 

 

 

 

 

 

 

 

WHI/ORN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHI/YEL

 

J7-10

 

B

 

 

 

 

WHI/YEL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J16-5

PNK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

O

 

 

 

VIO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J8-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J8-3

 

 

R

 

 

 

 

BLK

 

 

 

 

 

 

 

 

BLK ORN

 

 

 

 

 

 

 

 

GRN

 

 

 

J18-1

 

D

 

 

 

 

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GRN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J16-12

BLK

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P

 

WHI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

BLK

 

 

 

 

 

 

 

GRN

 

 

 

J18-6

 

 

 

 

 

 

 

 

WHI/YEL

 

BLK

WHI/ORN

BLK

O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LEFT

 

 

RIGHT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONDUCTANCE

 

CONDUCTANCE

GRN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SENSOR

 

SENSOR

t

 

 

 

 

 

 

 

 

DISPENSERS WITH

 

20

 

15

10

 

5

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PORTION CONTROL

 

J6-

 

J6-

J6-

 

J6-

 

J6-

 

 

 

 

 

 

 

 

 

 

 

LF DISP. SW.

 

S

J1-1

 

 

 

 

GRN

GRN/WHI

BLU/WHI

BLU/BLK ORN GRN/BLK WHI/BLK

WHI RED/BLK RED/WHI

ORN/BLK WHI/GRY

WHI/VIO WHI/YEL TAN RED

 

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLU/WHI

 

 

 

 

 

RED WHI/BLU

 

 

WHI/RED

 

 

 

 

 

 

 

 

 

W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I

 

 

RED/BLK

 

 

 

 

BLK VIO

 

 

BLK

BLK BLU

 

 

 

 

 

 

 

T

 

 

GRN

 

 

 

 

 

 

 

 

 

 

 

 

 

C

J1-5

 

ORN/BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GRN/WHI

 

 

 

 

 

 

 

 

 

 

 

 

BLK WHI

 

 

 

RED

BLK

WHI WHI

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED BLK

 

 

 

 

 

 

 

 

 

N

 

 

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

 

 

 

 

 

L

 

 

RED/WHI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK

 

 

 

 

 

RT DISP. SW.

 

E

J1-10

 

BLU/BLK

 

 

 

 

 

 

 

 

 

 

 

 

HEAT SINK

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

PELTIER

 

BLK

 

 

 

 

 

 

 

 

B

 

 

GRN/BLK

 

 

 

 

 

 

 

 

 

 

 

 

THERMISTOR

t

RED

 

 

 

 

 

 

 

 

O

 

 

WHI/BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

ORN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

WHI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J1-16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SELECTOR

 

 

SELECTOR

 

 

 

 

 

COOLING CABINET

 

t

 

 

 

 

 

 

 

 

 

 

 

 

SWITCH

 

 

SWITCH

 

 

 

 

 

 

CABINET

 

 

 

 

 

 

 

 

 

 

 

 

 

NITE

WHI/GRY

RINSE

WHI/YEL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THERMISTOR

 

 

 

 

 

 

 

 

 

 

 

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120 VOLTS AC 2 WIRE

 

RUN

 

WHI/VIO

PRIME

 

TAN

 

 

 

 

 

 

 

 

120/208-240 VOLTS AC 3 WIRE

 

 

 

 

BLK

 

 

208-240 VOLTS AC 2 WIRE

 

 

 

 

 

 

LLC Models only

SINGLE PHASE 50/60HZ

34641.0003A

01/07 © 2007 BUNN-O-MATIC CORPORATION

Models with Master ON/OFF Switch

33

34766 010407

 

SCHEMATIC WIRING DIAGRAM LCC-2A/LCA-2A/LCA-2A, PC

L1 CAPACITOR .01uF

 

CAPACITOR .01uF

N

GRN

 

GRN

 

 

 

GRN

 

 

RFI SUPPRESION

 

 

BLK

CAPACITOR 2.2uF

BLK

 

 

 

 

 

 

BLK-14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DOUBLE POLE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LIMIT THERMOSTAT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TRIAC

 

 

 

SW. & THERMOSTAT

 

 

 

 

1

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TANK HEATER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK-14

 

BLU-14

 

 

 

 

 

 

BLU-14

RED-14

 

RED-14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

4

 

 

 

 

 

 

 

 

 

 

 

BLK

Fuse 1

 

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHI

Fuse 2

 

WHI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 AMP

 

 

 

 

TAN

 

 

 

 

 

 

 

 

 

 

PORTION

 

 

10 AMP

 

 

 

 

 

 

 

 

TUBE

 

 

 

 

UNIVERSAL

 

 

 

 

 

 

 

 

 

 

 

 

 

CONTROL

 

 

 

 

OVERFLOW

 

 

 

 

 

 

 

 

POWER SUPPLY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARMER

 

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PROTECTION SW

 

 

 

 

 

 

 

BLK

 

 

 

 

WHI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

RED

WHI/GRY

 

 

 

 

TUBE

 

 

 

 

N(L2)

 

 

 

 

 

 

 

 

 

 

 

 

DOOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARMER

 

 

BLK

-V

L(L1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHI/GRY

 

 

 

 

 

 

 

GRN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED/BLK

 

 

 

 

 

 

 

 

+V

-V

 

GRN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SOL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HOT WATER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TOUCHPAD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

SOL

BRN/BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RIGHT DISP

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES (+)

3

 

 

 

 

 

 

 

TAN BLK

WHI

 

RED GRN

BLK

WHI

GRY ORN BLK BLK

 

 

 

 

RED

 

BRN/WHI

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

SOL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EXIT

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHI/BLU

 

 

 

LEFT DISP

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

J2-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO (-)

 

 

 

 

 

 

 

J1-1

 

J1-4

 

 

 

 

J2 -8

J15-1

J15-4

J3-1

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

SOL

BLU/BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHI/RED

 

 

 

 

 

 

 

 

 

 

 

RED

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REFILL

 

 

 

 

 

 

LEFT RPM

 

 

 

 

 

 

 

J14-1

 

 

 

 

 

 

 

 

J3-6

BLK

 

 

 

 

 

 

 

 

 

 

 

BLK

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SENSOR

 

GRN

BLU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

RED

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

J4-1

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED/BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RIGHT RPM

BLK

BLK

 

 

 

 

 

 

 

 

 

 

 

O

 

 

 

 

 

BRN/WHI

 

 

 

 

 

 

 

 

 

 

SENSOR

 

GRN

VIO

 

 

 

 

 

 

J14-7

 

 

 

N

 

 

 

 

 

BRN/BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHI/GRY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VIO

J7-1

 

 

 

 

T

 

 

 

 

J4-5

 

 

 

 

 

 

 

 

 

 

LEFT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK

RED

 

 

 

 

 

 

BLU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

 

 

BLU/BLK

 

 

 

 

 

 

 

 

 

 

PUMP

 

 

WHI/YEL

 

 

 

 

RED

 

 

 

 

 

 

 

 

 

 

J5-1

 

 

 

 

 

 

 

 

 

 

 

 

 

YEL

 

 

 

 

YEL

 

 

 

 

 

 

O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ORN

 

J7-5

 

 

 

 

L

 

 

 

 

J5-3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK

 

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RIGHT

 

ORN

 

 

 

 

BLK

 

 

 

 

 

 

P

 

 

 

 

J16-1

BLU

 

 

 

 

 

 

 

 

 

 

PUMP

 

 

 

 

 

 

RED

 

 

 

 

 

 

 

 

 

 

ORN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHI/ORN

 

 

 

 

WHI/ORN

 

 

 

 

 

 

 

 

 

 

 

 

WHI/ORN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHI/YEL

 

J7-10

 

 

 

C

 

 

 

 

 

WHI/YEL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PNK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J16-5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J8-1

 

 

 

 

 

 

 

 

 

VIO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J8-3

 

 

 

 

 

 

 

 

 

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

O

 

 

 

 

 

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GRN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK ORN

 

 

 

 

 

 

 

 

 

 

J18-1

 

 

 

A

 

 

 

 

 

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

 

 

GRN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J16-12

BLK

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P

 

WHI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

BLK

 

 

 

 

 

 

GRN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

O

 

 

 

 

 

 

 

 

 

 

J18-6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHI/YEL

 

BLK

WHI/ORN

BLK

GRN

 

 

 

 

 

 

 

 

DISPENSERS WITH

 

20

 

 

15

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PORTION CONTROL

 

J6-

 

 

J6-

 

J6-

 

 

J6-

 

J6-

 

 

 

LEFT

 

RIGHT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONDUCTANCE

CONDUCTANCE

 

 

 

 

 

 

 

 

 

 

 

 

 

GRN

GRN/WHI

BLU/WHI

BLU/BLK

ORN GRN/BLK

WHI/BLK

WHI RED/BLK RED/WHI

ORN/BLK

WHI/GRY

WHI/VIO WHI/YEL TAN RED

 

BLK

 

 

 

SENSOR

SENSOR

 

 

 

LF DISP. SW.

 

 

S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W J1-1

 

BLU/WHI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T

 

RED/BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED WHI/BLU

 

 

WHI/RED BLK

 

 

 

 

 

 

 

 

C

 

GRN/WHI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK VIO

 

 

BLK BLU

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

 

GRN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J1-5

 

ORN/BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

 

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK WHI

RED BLK

 

 

RED BLK

WHI WHI

 

 

 

 

 

 

 

L

 

BLU/BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED/WHI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RT DISP. SW.

 

 

E J1-10

 

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GRN/BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEAT SINK

 

 

 

 

 

 

 

 

 

 

 

 

WHI/BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PELTIER

 

 

 

 

 

 

 

 

 

O

 

ORN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THERMISTOR

RED BLK

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

WHI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D J1-16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SELECTOR

 

 

 

 

SELECTOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SWITCH

 

 

 

 

SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NITE

WHI/GRY

 

RINSE

WHI/YEL

 

 

 

 

COOLING CABINET

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

230 VOLTS AC

 

 

 

 

BLK

RUN

WHI/VIO

 

BLK

 

TAN

 

 

 

 

 

 

 

 

CABINET

 

 

 

 

 

 

 

 

 

 

 

PRIME

 

 

 

 

 

 

 

 

THERMISTOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 WIRE

 

 

 

 

 

 

 

 

 

 

 

 

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SINGLE PHASE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50 HZ

 

34641.0001J

09/06

© 2002 BUNN-O-MATIC CORPORATION

 

 

 

 

 

 

LCC Models only

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

34

34766 092706