Bunn CDBCF APS, CDBC TC, CDBC-APS, CDBCF TC User Manual

CDBC, CDBCF CDBC APS, CDBCF APS CDBC TC, CDBCF TC
(Dual Voltage Models Starting at Serial #CDBC024477)
DISCONTINUED VERSION |
The information in this manual |
is no longer current. |
OPERATING & SERVICE MANUAL
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 |
FAX: (217) 529-6644 |
29707.0001B 02/04 ©2003 Bunn-O-Matic Corporation |
www.bunnomatic.com |
INTRODUCTION
This equipment will brew a half-gallon batch of coffee into an awaiting dispenser. It can be easily configured for 120V 15 amp, 120/208V 20 amp or 120/240V 20 amp. The brewer may have a hot water faucet for allied beverage use. It is only for indoor use on a sturdy counter or shelf.
CONTENTS
Introduction & Warranty .................................................................................... |
2 |
User Notices ...................................................................................................... |
3 |
Electrical Requirements ..................................................................................... |
5 |
Plumbing Requirements, Initial Set-Up & Coffee Brewing ................................. |
6 |
Cleaning & Operating Controls .......................................................................... |
7 |
Adjustments & Optional Settings ....................................................................... |
8 |
Pulse Brew Setup Procedure ............................................................................. |
9 |
Water Sensing Threshold Adjustment Procedure .............................................. |
9 |
Troubleshooting ............................................................................................... |
10 |
Diagnostics ...................................................................................................... |
20 |
Service............................................................................................................. |
21 |
Wiring Diagrams .............................................................................................. |
31 |
BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY
Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows:
1)All equipment other than as specified below: 2 years parts and 1 year labor.
2)Electronic circuit and/or control boards: parts and labor for 3 years.
3)Compressors on refrigeration equipment: 5 years parts and 1 year labor.
4)Grinding burrs on coffee grinding equipment to grind coffee to meet original factory screen sieve analysis: parts and labor for 3 years or 30,000 pounds of coffee, whichever comes first.
These warranty periods run from the date of installation BUNN warrants that the equipment manufactured by it will be commercially free of defects in material and workmanship existing at the time of manufacture and appearing within the applicable warranty period. This warranty does not apply to any equipment, component or part that was not manufactured by BUNN or that, in BUNN’s judgment, has been affected by misuse, neglect, alteration, improper installation or operation, improper maintenance or repair, damage or casualty. This warranty is conditioned on the Buyer 1) giving BUNN prompt notice of any claim to be made under this warranty by telephone at (217) 529-6601 or by writing to Post Office Box 3227, Springfield, Illinois 62708-3227; 2) if requested by BUNN, shipping the defective equipment prepaid to an authorized BUNN service location; and 3) receiving prior authorization from BUNN that the defective equipment is under warranty.
THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTY, WRITTEN OR ORAL, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF EITHER MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. The agents, dealers or employees of BUNN are not authorized to make modifications to this warranty or to make additional warranties that are binding on BUNN. Accordingly, statements by such individuals, whether oral or written, do not constitute warranties and should not be relied upon.
If BUNN determines in its sole discretion that the equipment does not conform to the warranty, BUNN, at its exclusive option while the equipment is under warranty, shall either 1) provide at no charge replacement parts and/or labor (during the applicable parts and labor warranty periods specified above) to repair the defective components, provided that this repair is done by a BUNN Authorized Service Representative; or 2) shall replace the equipment or refund the purchase price for the equipment.
THE BUYER’S REMEDY AGAINST BUNN FOR THE BREACH OF ANY OBLIGATION ARISING OUT OF THE SALE OF THIS EQUIPMENT, WHETHER DERIVED FROM WARRANTY OR OTHERWISE, SHALL BE LIMITED, AT BUNN’S SOLE OPTION AS SPECIFIED HEREIN, TO REPAIR, REPLACEMENT OR REFUND.
In no event shall BUNN be liable for any other damage or loss, including, but not limited to, lost profits, lost sales, loss of use of equipment, claims of Buyer’s customers, cost of capital, cost of down time, cost of substitute equipment, facilities or services, or any other special, incidental or consequential damages.
Page 2 |
29707.1 021804 |
|

USER NOTICES
Carefully read and follow all notices in this manual and on the equipment. All labels on the equipment should be kept in good condition. Replace any unreadable or damaged labels.
#00658.0000
#00831.0000
! CAUTION
When re-wiring the machine for operation on 120/208V or 120/240V, the replacement Power Supply Cord must be UL Listed Flexible Cord Type SO, SJO, SJTO, HSJO or SJOW, No. 12 AWG, 4 Conductor, Rated 90° C. Attachment Plug Cap must be UL Listed, NEMA 14-20P or L14-20P Configuration, Rated 125/250V, 20 AMPS. The Power Supply Cord must be at least 3 feet long and maximum 6 feet long (measured from Strain Relief to end of the Attachment Plug Cap.)
#34072.0000
Optional Field Wiring
120 V, 15.0 A, 1800 W 1PH, 2-Wire, 60HZ
#29710.0005 (3 Warmers)
CDBC(F)-DV BREWERS
Optional Field Wiring
120 V, 12.5 A, 1500 W 1PH, 2-Wire, 60HZ
#29710.0006 (No Warmer)
CDBC(F) APS-DV BREWERS
Optional Field Wiring
120/208-240 V, 15.6-17.5 A, 2980-3850 W 1PH, 3-Wire, 60HZ
#29710.0007 (3 Warmers)
CDBC(F)-DV BREWERS
Optional Field Wiring
120/208-240 V, 13.0-15.0 A, 2680-3550 W 1PH, 3-Wire, 60HZ
#29710.0008 CDBC(F) APS-DV & TC-DV
BREWERS
Page 3 |
29707.1 082803 |
|

USER NOTICES (CONT.)
#02765.0000
#12364.0000
#00656.0000
Page 4 |
29707.1 082803 |
|

Models CDBC-DV, CDBC-APS DV & CDBCF TC-DV
ELECTRICAL REQUIREMENTS
CAUTION - The brewer must be disconnected from the power source until specified in Initial Set-Up.
Requirements for brewers without an attached cord set are as follows:
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
120V VERSION |
|
120/208-240V VERSION |
Requires 2-wire, grounded service rated 120 volts ac, 15 amp, single phase, 60 Hz.
Requires 3-wire, grounded service rated 120/208-240 volts ac, 20 amp, single phase, 60 Hz.
ELECTRICAL HOOK-UP
CAUTION – Improper electrical installation will damage electronic components.
1.An electrician must provide electrical service.
2.Determine the available on-site electrical service.
3.Select the desired unit voltage based on the available on-site electrical service.
4.Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.
5.Remove the front access panel beneath the sprayhead to gain access to the terminal block.
6.Feed the supply leads through the rear of the brewer.
7.Using the above diagrams, connect the desired electrical service to the field wiring terminal block.
8.If wiring the machine for operation on 120/208 or 120/240 volts with a Power Supply Cord, the Power Supply
Cord must be UL Listed Flexible Cord Type SO, SJO, SJTO, HSJO or SJOW, No. 12 AWG, 4 Conductor, Rated 90° C. Attachment Plug Cap must be UL Listed, NEMA 14-20P or L14-20P Configuration, Rated 125/250V, 20 AMPS. The Power Supply Cord must be at least 3 feet long and maximum 6 feet long (measured from Strain Relief to end of the Attachment Plug Cap).
9.Before proceeding, verify the voltage at the field wiring terminal block.
10.Set toggle switch on component bracket to the appropriate position and replace the access panel.
11.If plumbing is to be hooked up later be sure the brewer is disconnected from the power source. If plumbing has been hooked up, the brewer is ready for Initial Set-Up.
Page 5 |
29707.1 082803 |
|

PLUMBING REQUIREMENTS
These brewers must be connected to a cold water system with operating pressure between 20 and 90 psi (138 and 620 kPa) from a 1⁄2" or larger supply line. A shut-off valve should be installed in the line before the brewer. Install a regulator in the line when pressure is greater than 90 psi (620 kPa) to reduce it to 50 psi (345 kPa). The water inlet fitting is 1⁄4" flare.
NOTE - Bunn-O-Matic recommends 1⁄4" copper tubing for installations of less than 25 feet and 3⁄8" for more than 25 feet from the 1⁄2" water supply line. A tight coil of copper tubing in the water line will facilitate moving the brewer to clean the counter top. Bunn-O-Matic does not recommend the use of a saddle valve to install the brewer. The size and shape of the hole made in the supply line by this type of device may restrict water flow.
This equipment must be installed to comply with the Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. (BOCA)
and the Food Service Sanitation Manual of the Food and Drug Administration (FDA).
1.Flush the water line and securely attach it to the inlet fitting at the left rear of the brewer.
2.Turn on the water supply.
INITIAL SET-UP
1.Insert an empty funnel into the funnel rails.
2.Place a decanter with a small amount of water under the funnel.
3.Connect the brewer to the power source.
4.Press the "ON/OFF" switch (indicator glowing).
5.Water will flow into the tank and stop when the tank is filled to its capacity.
6.Wait approximately twenty minutes for the water in the tank to heat to the proper temperature.
7.FAUCET MODELS:
On faucet models, place a decanter beneath the faucet and open the faucet handle. Release it when you hear the tank refilling. Empty and place back onto warmer under the funnel.
NON-FAUCET MODELS
On non-faucet models, initiate a brew cycle and allow it to run approximately 20 seconds. Turn the ON/OFF switch to the "OFF" position. Allow the water to drain and empty the decanter.
8.With the "ON/OFF" switch in the "ON" position (indicator glowing), momentarily press and release the "BREW" switch.
9.Allow the cycle to finish and measure the amount of water in the decanter. It should be 64 ounces ± 2. Refer to the adjustments section of this manual should the volume need to be increased or decreased.
The brewer is now ready for use in accordance with the coffee brewing instructions below.
COFFEE BREWING
1.Insert a BUNN® filter into the funnel.
2.Pour the fresh coffee into the filter and level the bed of grounds by gently shaking.
3.Slide the funnel into the funnel rails.
4.Place an empty decanter beneath the funnel.
5.Press the "ON/OFF" switch (indicator glowing) then momentarily press and release the "BREW" switch.
6.When brewing is completed, simply discard the grounds and filter.
Page 6 |
29707.1 021804 |
|

CLEANING
1.The use of a damp cloth rinsed in any mild, nonabrasive, liquid detergent is recommended for cleaning all surfaces on Bunn-O-Matic equipment.
2.Check and clean the sprayhead. The sprayhead holes must always remain open.
OPERATING CONTROLS
P1626 |
ON/OFF SWITCH
Pressing the "ON/OFF" switch (indicator glowing) supplies power to the brew station warmer, enables the brew circuit, and energizes the tank refill circuit. Pressing the switch again (indicator not glowing) stops tank refilling and brewing and de-energizes the brew station warmer. Stopping a brew cycle after it has been started will not stop the flow of water into the decanter until the funnel is empty.
NOTE – Hot water will be available at the faucet in a limited amount when the "ON/OFF" switch is in the "OFF" position because the tank will not refill.
BREW SWITCH
Momentarily pressing and releasing the switch starts a brew cycle when the "ON/OFF" indicator is glowing. NOTE – The "ON/OFF" indicator must be glowing to initiate and complete a brew cycle.
ADDITIONAL WARMER SWITCHES
Pressing any additional warmer switch so that the indicator is glowing, supplies power to the associated warmer.
READY INDICATOR
This indicator glows when the preset temperature has been achieved. The word "NOT" above "READY" will glow in all other instances.
Page 7 |
29707.1 021004 |
|

ADJUSTMENTS & OPTIONAL SETTINGS
HIDDEN |
SWITCH |
P1866 |
Setting Brew Temperature
The brewer is factory set to brew at 200°F (95°C). To change this setting, press and hold the "HIDDEN" switch beneath the "®". The word "TEMP" above the "ON/OFF" switch will glow to correspond with the temporary function change of this switch. Repeatedly press and release the "ON/OFF" switch until one of the bank of temperature indicators shows the approximate desired temperature. When two indicators are glowing, the temperature is approximately the number between them.
Setting Brew Lockout
The brewer is factory set with the brew lockout disabled. Brew lockout prevents starting a brew cycle if the ready indicator is not glowing. When an attempt at brewing cannot be allowed, the word "NOT" and "LOCKOUT" flash for three seconds to indicate the reason the brew can't begin. To change the condition of the brew lockout, press and hold the "HIDDEN" switch beneath the "®" and momentarily press the "BREW" switch.
Adjusting Automatic Warmer Shut-Off
The brewer is factory set with this feature disabled. The automatic warmer shut-off de-energizes all warmers after a predetermined time period after the most recent brew cycle. To change the setting, press and hold the "BREW" switch and the "HIDDEN" switch beneath the "®" for five seconds, the entire bank of temperature indicators will flash on-and-off. Release both switches. Pressing and releasing the "BREW" switch will select the number of temperature indicators from none to five. When no indicators are glowing, this feature is disabled and all warmers will be controlled only by their respective switches. When one to five indicators are glowing, it indicates the approximate number of hours of delay before all warmers will be automatically de-energized after the most recent brew cycle.
IMPORTANT: The tank must be full and fill solenoid shut off prior to making these adjustments. The sprayhead must be installed when making adjustments.
Adjusting Brew Volumes
The brewer is factory set to deliver 64 ounces ± 2 for each brew cycle.
BREW VOLUME SET-UP: Use the following steps when the setting is unknown or a different circuit board is being installed.
1.Place an empty funnel in the funnel rails and an empty decanter or graduated vessel beneath the funnel.
2.Press the "ON/OFF" switch (Indicator glowing).
3.Press and hold the brew start button until you hear the brew solenoid click on-and-off three times (approximately 10 seconds). Release the button.
4.Allow the cycle to continue until the desired amount of water is dispensed and then turn "OFF" the brewer. The brewer is now set to dispense this amount of water for each subsequent brew cycle.
To increase the amount of water for each brew cycle place an empty funnel in the funnel rails and an empty decanter or graduated vessel beneath the funnel. Press the "ON/OFF" switch. Press and hold the "BREW" switch
Page 8 |
29707.1 021804 |
|
ADJUSTMENTS & OPTIONAL SETTINGS (CONT.)
until you hear the solenoid click on-and-off three times (approximately 10 seconds), then release the "BREW" switch. Momentarily press and release the "BREW" switch once for each ounce (approximate) of water to be added to the prior setting and allow the brew cycle to finish.
To decrease the amount of water for each brew cycle place an empty funnel in the funnel rails and an empty decanter or graduated vessel beneath the funnel. Press the "ON/OFF" switch. Momentarily press and release the "BREW" switch once for each ounce (approximate) of water to be removed from the existing setting. Press and hold the "BREW" switch until you hear the solenoid click on-and-off three times (approximately 5 seconds), then release the "BREW" switch and allow the cycle to finish.
PULSE BREW SETUP PROCEEDURE
The pulse brew parameters (initial fill time, off times, and remaining on times) are entered using the following set-by-example process.
1.First set the brew volume using the standard procedure in Brew Volume Setup.
2.Position an empty container under the sprayhead. Allow the tank to finish refilling. Make sure that the READY lamp is on, or that the BREW LOCKOUT function is turned off.
3.Press and hold the OFF/ON button. The brew valve will turn on after 10 seconds. Release the button. This begins the initial on-time setting. When the spray has continued for the desired time, momentarily press the OFF/ON button.
4.The spray is now stopped and the off time setting has begun. Press the OFF/ON button momentarily to end the off time.
5.The spray is now on again and the remaining on time setting has begun. Press the OFF/ON button momentarily at the end of the desired remaining on time.
6.The setup is now complete and the parameters are stored in memory. The spray will continue the off and on cycles until the brew volume of step 1 is complete. Pressing the OFF/ON button again will terminate the brewing cycle, with the parameters stored in memory.
7.If only a preinfusion is desired, i.e. an initial on time followed by one off period, use the same procedure, but stop after step 4 and allow the brew to finish the volume set in step 1. This will store the initial on time and off time in memory.
Procedure for Disabling Pulse Brew or Preinfusion:
1.Position an empty container under the sprayhead. Allow the tank to finish refilling. Make sure that the READY lamp is on, or that the BREW LOCKOUT function is turned off.
2.Press and hold the OFF/ON button. The brew valve will turn on after 10 seconds. Release the button.
3.Allow the spray to continue and press no buttons until spray stops. The pulse and preinfusion functions are
now disabled.
NOTE: When the brewer has been set up for pulse or preinfusion, the adjustment of brew volume is done the same as always and has no effect on the pulse brew parameters. The pulsing is temporarily disabled while adjusting the brew volume and automatically returns during normal brewing.
WATER SENSING THRESHOLD ADJUSTMENT PROCEDURE
1.Make sure the tank is full of water to be used for calibration. The water must be in contact with the refill probe.
2.Unplug the brewer from the power source, then press and hold the BREW button while power is reapplied.
3.Continue pressing the BREW button until the READY indicator begins to flash. Release the BREW button and then press it again momentarily.
4.The new calibration is automatically completed within a few seconds. If the water is too pure for use with the brewer, the READY indicator will flash very rapidly and the old calibration will be retained.
Page 9 |
29707.1 021804 |
|
TROUBLESHOOTING
A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department.
•Inspection, testing, and repair of electrical equipment should be performed only by qualified service personnel.
•All electronic components have 120 volt ac and low voltage dc potential on their terminals. Shorting of terminals or the application of external voltages may result in board failure.
•Intermittent operation of electronic circuit boards is unlikely. Board failure will normally be permanent. If an intermittent condition is encountered, the cause will likely be a switch contact or a loose connection at a terminal or crimp.
•Solenoid removal requires interrupting the water supply to the valve. Damage may result if solenoids are energized for more than ten minutes without a supply of water.
•The use of two wrenches is recommended whenever plumbing fittings are tightened or loosened. This will help to avoid twists and kinks in the tubing.
•Make certain that all plumbing connections are sealed and electrical connections tight and isolated.
•This brewer is heated at all times. Keep away from combustibles.
WARNING – • Exercise extreme caution when servicing electrical equipment.
•Unplug the brewer when servicing, except when electrical tests are specified.
•Follow recommended service procedures.
•Replace all protective shields or safety notices.
Before troubleshooting this brewer, check for the following:
Control Boards
1.Make sure ribbon cable is properly attached to the control board (ALL PINS INSERTED INTO PLUG).
2.Make sure there is a nylon insulating washer under each screw head that holds the control board to the plastic front end cap. This is important for proper operation.
3.Make sure before servicing brewer that voltage is present at control board.
4.Press any warmer switch or observe if any indicator lights are glowing on the control panel. If so, proceed with testing. If not, check for voltage across pins 1 & 2 of the ten pin J1 connector (black and white wires). If voltage is present, replace the control board. If voltage is not present, check wiring and voltage across terminal block (black and white). Correct the problem and retest before proceeding with testing.
Page 10 |
29707.1 082803 |
|

TROUBLESHOOTING (cont.) |
|
|
|
REFILL CIRCUIT |
|
|
|
PROBLEM |
|
PROBABLE CAUSE |
|
Will not fill or refill |
1. |
Power off to brewer |
|
|
2. |
Water shut off |
|
|
3. |
Display flashing |
4. ON/OFF Switch
5. Lime build up on Probe
6. Refill Valve or Control Board
REMEDY
Press OFF/ON switch on control panel to determine if power is ON.
Make sure water is ON.
Brewer has shut down due to malfunction (See Diagnostic Chart in manual, Page 20, or under top lid of brewer).
Make sure ON/OFF Switch is "ON" and indicator is lit.
Remove the Level Probe and check for lime deposit on tip. Clean and reinstall.
Disconnect the brewer from the power source and remove wires from refill valve coil. Check for continuity across the terminals of the solenoid coil. If continuity is not present, replace the refill valve (See page 29). If continuity is present, the coil may be stuck closed. Shut water off to brewer. Set the ON/OFF switch to the "OFF" position. Open the faucet and drain water down in the tank until flow stops or slows to a trickle. Attach a voltmeter to the terminals of the refill solenoid. Connect the brewer to the power source. Press the switch "ON". Within five seconds, voltage should be present at the solenoid terminals. If voltage is not present, refer to the wiring diagrams and check the wiring harness.
Page 11 |
29707.1 021804 |
|

TROUBLESHOOTING (cont.)
REFILL CIRCUIT (cont.)
PROBLEM
Fill or refill does not shut "OFF" (ON/ OFF Switch "ON")
Fill or refill does not shut "OFF" (ON/ OFF Switch "OFF")
PROBABLE CAUSE
1.Lime build up on probe
2.Water Level Probe Sensing System
3. Refill valve or control board
1. Refill valve or control board
REMEDY
Remove Level Probe and check for lime deposits on tip. Clean and reinstall.
Disconnect the brewer from the power source. Disconnect the J3 connector from the control board. Check for continuity from the nut on top of the level probe to pin 1 of the plug, continuity should be present. Pull the temperature probe up about an inch from the grommet. Check for continuity from the outside surface of the temperature probe and pin 4 of the plug, continuity should be present. Connect the J3 plug to the control board and proceed to step 3.
Press ON/OFF switch to "ON" (Indicator lamp should be lit). If water continuously flows out of air vent tube, disconnect the brewer from the power source. If water flow stops, replace the control board. If water flow does not stop, repair or replace the refill solenoid. (See page 29)
If water continuously flows out of air vent tube, disconnect the brewer from the power source. If water flow does not stop, repair or replace the refill solenoid. If the valve closes when power is removed, replace the control board. (See page 22)
Page 12 |
29707.1 082803 |
|

TROUBLESHOOTING (cont.)
HEATING CIRCUIT
PROBLEM
Water does not heat to proper temperature
IMPORTANT: Make sure no temperature tests are taken before the ready light is "ON". Tank temperature must be stabilized before readings are taken.
PROBABLE CAUSE
1.Display flashing
2.Water not touching temperature probe
3.Water Level Probe Sensing System
4. Temperature Probe
5. Limit Thermostat
REMEDY
Brewer has shut down due to malfunction (See Diagnostic Chart in manual, Page 20, or under top lid).
Remove temperature probe and grommet. Look into hole on tank lid. Water must be within one inch from top of tank.
Disconnect the brewer from the power source. Disconnect the J3 connector from the control board. Check for continuity from the tank mounting screw where the green wire mounts, to pin 2 of the plug, continuity should be present. Pull the temperature probe up about an inch from the grommet. Check for continuity from the outside surface of the temperature probe and pin 4 of the plug, continuity should be present. Connect the J3 plug to the control board and proceed to step 4.
Remove the probe from the grommet and submerge in a water bath of approximately 70°F(21°C). Connect an ohmmeter to pins 3 and 4 of the J3 connector. At 60°F(16°C) the reading should be 15.3k ±2k OHMS, at 70°F(21°C) the reading should be 11.8k ± 2k OHMS, and at 80°F(27°C) the reading should be 9.3k ± 2k OHMS. If the probe is within these parameters, reconnect the J3 plug to the control board.
Disconnect the brewer from the power source. Check for continuity across the limit thermostat terminals. Continuity should be present. If not replace the limit thermostat. (See page 25)
Page 13 |
29707.1 082803 |
|

TROUBLESHOOTING (cont.) |
|
|
HEATING CIRCUIT (cont.) |
|
|
PROBLEM |
|
PROBABLE CAUSE |
Water does not heat to proper tem- |
6. Tank Heater |
|
perature (cont.) |
|
|
IMPORTANT: Make sure no tem- |
|
|
perature tests are taken before the |
|
|
ready light is "ON". Tank tempera- |
|
|
ture must be stabilized before read- |
|
|
ings are taken. |
|
REMEDY
Disconnect the brewer from the power source. Check for continuity between the white terminal of the terminal block (or red terminal on 208/240volt models) and the black wire on the relay on the control board (Toggle Switch must be in 120/208-240V position on 208V & 240V models). There should be a low OHM reading. If no continuity is present, check for a wiring problem, then replace the tank heater if no wiring problem is found. (See page 26)
Page 14 |
29707.1 082803 |
|
TROUBLESHOOTING (cont.) |
|
|
|
|
HEATING CIRCUIT (cont.) |
|
|
|
|
PROBLEM |
|
PROBABLE CAUSE |
|
REMEDY |
Spitting or excessive steaming |
1. Lime build up on temperature |
Inspect probe and tank assembly |
||
(cont.) |
probe, tank or tank heater |
for excessive lime deposits. Delime |
||
|
|
|
|
as required. |
|
|
2. Temperature Probe |
Remove the probe from the grom- |
|
|
|
|
|
met and submerge in a water bath |
|
|
|
|
of approximately 70°F(21°C). Con- |
|
|
|
|
nect an ohmmeter to pins 3 and 4 of |
|
|
|
|
the J3 connector. At 60°F(16°C) the |
|
|
|
|
reading should be 15.3k ±2k OHMS, |
|
|
|
|
at 70°F(21°C) the reading should |
|
|
|
|
be 11.8k ± 2k OHMS, and at |
|
|
|
|
80°F(27°C) the reading should be |
|
|
|
|
9.3k ± 2k OHMS. If the probe is |
|
|
|
|
within these parameters, reconnect |
|
|
|
|
the J3 plug to the control board. |
|
|
3. Control Board |
Set the temperature to 200°F(93°C). |
|
|
|
|
|
Let tank temperature stabilize. If |
|
|
|
|
temperature in tank is above tem- |
|
|
|
|
perature setting by more than 7°F, |
|
|
|
|
replace the control board. (See page |
|
|
|
|
22) |
Brewer is making unusual noises |
1. Plumbing lines |
Plumbing lines should not rest on |
||
|
|
|
|
the counter top. |
|
|
2. Water supply |
The brewer must be connected to a |
|
|
|
|
|
cold water supply. |
|
|
3. Lime build up |
Remove the tank lid and clean in- |
|
|
|
|
|
side of tank with a deliming agent, if |
|
|
|
|
necessary. |
Page 15 |
29707.1 082803 |
|

TROUBLESHOOTING (cont.) |
|
|
BREWING CIRCUIT |
|
|
PROBLEM |
|
PROBABLE CAUSE |
Brew cycle will not start |
|
1. Display flashing |
2. No water
3. No power or incorrect voltage to the brewer
4. ON/OFF switch not in the "ON" position
5. Low water temperature (Brew lockout is enabled)
6. Water not touching refill probe inside tank
7. Switch panel
REMEDY
Brewer has shut down due to malfunction (See Diagnostic Chart in manual, Page 20, or under top lid of brewer).
Water lines and valves to the brewer must be open.
Check for voltage across the terminals at the terminal block.
The indicator lamp must be lit
Allow brewer to heat until ready lamp is lit, or disable the brew lockout feature. (See page 8 & 9)
Press ON/OFF switch (indicator must be lit). Brewer will refill until water touches probe inside tank. Water must be in contact with refill probe before brew cycle will start.
Disconnect the brewer from the power source. Disconnect the ribbon connector from the control board. Check for continuity between pins 1 & 2 (An arrow on the connector indicates pin 1). No continuity should be present. Press the BREW switch. Continuity should be present for as long as the switch is held down. If no continuity is present, replace the switch membrane decal. (See page 23)
Page 16 |
29707.1 082803 |
|
TROUBLESHOOTING (cont.) |
|
|
|
|
BREWING CIRCUIT (cont.) |
|
|
|
|
PROBLEM |
|
PROBABLE CAUSE |
|
REMEDY |
Brew cycle will not start (cont.) |
8. Control board or dispense valve |
If the switch panel is operating prop- |
||
|
|
|
|
erly, proceed as follows. Attach a |
|
|
|
|
voltmeter to the terminals of the |
|
|
|
|
dispense solenoid. Connect the |
|
|
|
|
brewer to the power source. Turn |
|
|
|
|
on the brewer and press the BREW |
|
|
|
|
switch. Voltage should be present |
|
|
|
|
at the solenoid terminals. If voltage |
|
|
|
|
is not present, refer to the wiring |
|
|
|
|
diagrams and check the wiring har- |
|
|
|
|
ness. If voltage is present, check for |
|
|
|
|
continuity across the terminals of |
|
|
|
|
the solenoid coil. If continuity is not |
|
|
|
|
present, replace the solenoid (See |
|
|
|
|
page 24). If continuity is present, |
|
|
|
|
the valve may be stuck closed. |
Consistently low beverage level in |
1. Brew volume |
Set up brewer according to instruc- |
||
the dispenser or beverage overflows |
NOTE: Volume adjustments must |
tions in section Adjustments-Brew |
||
dispenser |
be made with sprayhead installed. |
Volumes. (See page 8) Using a stop |
||
|
|
|
|
watch or second hand, time the |
|
|
|
|
length of the brew cycle. Record |
|
|
|
|
this time inside the top lid. If service |
|
|
|
|
is ever needed again, use the time |
|
|
|
|
as reference to determine if time |
|
|
|
|
has changed. |
|
|
2. Lime build up |
Inspect the dispense valve and |
|
|
|
|
|
sprayhead for excessive lime de- |
|
|
|
|
posits. Delime as required. |
|
|
3. Dispense Valve |
Remove dispense valve and clear |
|
|
|
|
|
any obstructions. Rebuild or re- |
|
|
|
|
place valve if necessary. (See page |
|
|
|
|
24) |
Page 17 |
29707.1 082803 |
|
TROUBLESHOOTING (cont.) |
|
|
|
|
BREWING CIRCUIT (cont.) |
|
|
|
|
PROBLEM |
|
PROBABLE CAUSE |
|
REMEDY |
Dripping from sprayhead |
|
1. Lime build up |
|
Inspect the tank assembly for ex- |
|
|
|
|
cessive lime deposits. Delime as |
|
|
|
|
required. |
|
|
2. Dispense valve |
|
Remove the dispense valve and clear |
|
|
|
|
any obstructions. Rebuild or re- |
|
|
|
|
place the valve if necessary. (See |
|
|
|
|
page 24) |
Weak beverage |
|
1. Sprayhead |
|
A clean sprayhead must be used for |
|
|
|
|
proper extraction. |
|
|
2. Water temperature |
|
Place an empty brew funnel on an |
|
|
|
|
empty decanter beneath the spray- |
|
|
|
|
head. Initiate brew cycle and check |
|
|
|
|
the water temperature immediately |
|
|
|
|
below the sprayhead with a ther- |
|
|
|
|
mometer. The reading must not be |
|
|
|
|
less than 195°F (91°C). Adjust the |
|
|
|
|
temperature setting to increase the |
|
|
|
|
water temperature. Refer to Initial |
|
|
|
|
Set-up instructions. |
3.Filter type
4.Coffee grind
5.Funnel loading
BUNN® paper filters must be used for proper extraction.
A fine drip or grind must be used for proper extraction.
The BUNN® paper filter must be centered in the funnel and the bed of grounds leveled by shaking gently.
Page 18 |
29707.1 082803 |
|

TROUBLESHOOTING (cont.) |
|
|
|
BREWING CIRCUIT (cont.) |
|
|
|
PROBLEM |
|
PROBABLE CAUSE |
|
Dry coffee grounds remain in the |
1. |
Sprayhead |
|
funnel |
|
|
|
|
|
2. |
Funnel loading |
1. Warmer
Low beverage serving temperature
REMEDY
Make sure sprayhead is present and holes are clear and unobstructed. (See Weak Beverage Page 18)
The BUNN® paper filter must be centered in the funnel and the bed of grounds leveled by shaking gently.
Disconnect the brewer from the power source. Remove the warmer plate and turn upside down to expose the warmer terminals. Remove the two wires. Check for continuity across the two warmer terminals. If continuity is not present, replace the warmer element (See page 30). If continuity is present, reconnect the wires to the warmer element. Check for voltage at the warmer terminals. Turn the warmer switch "ON". The indicator light will come on. Voltage should be present at the terminals. If not, disconnect power supply and check wiring and switch.
Page 19 |
29707.1 082803 |
|
DIAGNOSTICS
Intermittent flashing of the bank of temperature indicators, indicates that a fault exists. Count the number of flashes between pauses and use this chart as a guide to investigating the fault.
FLASHES |
CAUSE |
THINGS TO CHECK |
|
|
|
1 |
Dry Plug - In Fault - |
Water Pressure (Is water shut "OFF"?) |
|
Sheath of temperature probe dry for 10 minutes after power-up |
Temperature probe wiring |
|
|
Fill valve wiring, function, & strainer |
|
|
Green wire between tank and circuit board |
|
|
|
2 |
Low Tank Level Fault - |
Water pressure (Is water shut "OFF"?) |
|
Level probe dry for 7 minutes after fill valve is energized |
Level probe wiring |
|
|
Temperature probe wiring |
|
|
Fill valve wiring, function, & strainer |
|
|
|
3 |
Low Water Temperature Fault - |
Tank heater wiring & function |
|
Sensor in tank is calling for heat for 30 minutes or more |
Temperature probe wiring |
|
|
|
4 |
Tank Sensor Disagreement - |
Temperature probe wiring |
|
Level probe detects water, but dry plug-in probe dry |
Level probe wiring |
|
|
Green wire between tank and circuit board |
|
|
|
5 |
Temp Sensor Out-of-Range - High |
Sensor not connected to circuit board |
|
|
|
6 |
Temp Sensor Out-of-Range - Low |
Sensor wires shorted together or to chassis |
|
|
|
Page 20 |
29707.1 082803 |
|

SERVICE |
|
This section provides procedures for testing and |
|
replacing various major components used in this |
|
brewer should service become necessary. Refer to |
|
Troubleshooting for assistance in determining the |
|
cause of any problem. |
|
WARNING - Inspection, testing, and repair of electri- |
|
cal equipment should be performed only by qualified |
|
service personnel. The brewer should be unplugged |
|
when servicing, except when electrical tests are re- |
|
quired and the test procedure specifically states to |
|
plug in the brewer. |
|
COMPONENT ACCESS |
|
WARNING - Disconnect the brewer from the power |
|
source before the removal of any panel or the replace- |
|
ment of any component. |
|
All components are accessible by the removal of |
|
the top cover or warmer housing, front access panel |
|
and warmer plate(s). |
|
The top cover is attached with one #4-40 screw. |
|
The front access panel is attached with four #6-32 |
|
screws. |
|
Each warmer assembly is attached with three #4- |
|
40 screws. |
|
Contents |
|
Control Board .................................................... 22 |
|
Switch Panel ...................................................... 23 |
|
Dispense Valve .................................................. 24 |
|
Limit Thermostat ............................................... 25 |
|
Tank Heaters ...................................................... 26 |
|
Voltage Selector Switch ..................................... 28 |
! |
|
|
Refill Valve ......................................................... 29 |
|
Warmer Elements .............................................. 30 |
|
Wiring Diagrams ............................................... 31 |
|
|
P1889 |
|
FIG. 1 COMPONENT ACCESS |
Page 21 |
29707.1 082803 |
|

SERVICE (cont.)
CONTROL BOARD
P1846 |
FIG. 2 CONTROL BOARD |
Location:
The Control Board is located inside the top cover behind the front end cap.
Test Procedures:
The test procedures for the control board will vary depending upon the problems experienced by the brewer. Refer to the Troubleshooting guide beginning on page 10. The troubleshooting guide is divided into three sections, Refill Circuit, Heating Circuit, and Brewing Circuit.
Removal and Replacement:
1.Disconnect the black wire and blue wire from the relay on the control board.
2.Disconnect the 10-pin connector and the 4-pin connector from the main wiring harness.
3.Disconnect the 11-pin connector from the control panel.
4.Remove the four #6 screws and four nylon washers and the two #4-40 screws securing the control board to the end cap assembly.
5.Install a new control board and secure with the four #6 screws and nylon washers and the two #4- 40 screws to the end cap assembly.
NOTE: The four nylon washers must be installed under the heads of the four #6 screws to prevent a possible shorting of the control board circuits.
6.Connect the 11-pin connector from the control panel.
7.Connect the 10-pin connector and the 4-pin connector from the main wiring harness.
8.Connect the blue wire and black wire to the relay on the control board.
9.Refer to Adjustments and Optional Settings (See page 9) to program the new control board.
Page 22 |
29707.1 082803 |
|

SERVICE (cont.)
SWITCH PANEL |
P1848 |
FIG. 3 SWITCH PANEL |
Location:
The Switch Panel is located in the front of the hood.
Test Procedures:
The test procedures for the switch panel and the control board will vary depending upon the problems experienced by the brewer. Refer to the Troubleshooting guide beginning on page 10. The troubleshooting guide is divided into three sections, Refill Circuit, Heating Circuit, and Brewing Circuit.
Removal and Replacement:
1.Disconnect the 11-pin connector to the switch panel from the control board.
2.Remove the four #6 screws, nylon washers and the two #4-40 screws securing the control board to the end cap assembly and set aside.
3.Gently pry the switch panel from the end cap assembly.
4Remove any adhesive that remains on the end cap.
5.Remove the adhesive backing from the new switch panel. Insert the ribbon connector through the slot in the end cap and apply the switch panel to the end cap.
6.Install the control board to the back side of the end cap using the four #6 screws, nylon washers and the two #4-40 screws to the end cap assembly.
NOTE: The four nylon washers must be installed under the heads of the four #6 screws to prevent a possible shorting of the control board circuits.
7.Reconnect the 11-pin connector from the switch panel to the control board making sure every pin on the control board is inserted into the ribbon cable plug.
Page 23 |
29707.1 082803 |
|

SERVICE (cont.)
DISPENSE VALVE
6. Connect the voltmeter lead ends to the dispense valve coil terminals. Connect the brewer to the power source. Brewer temperature lockout must be disabled. Place "ON/OFF" Switch in the "ON" position. Press and release the brew switch. The indication must be 120 volts ac.
7. Disconnect the brewer from the power source.
If voltage is present as described, but no coil action is observed, nor "clicking" heard, dispense valve is defective. Replace valve and test again to verify repair. If voltage is not present as described, refer to Wiring Diagrams and check the brewer wiring harness. Also check the control board and switch panel for proper operation. (See Pages 22 and 23.)
|
P1852 |
Removal and Replacement: |
|
|
|
||
|
FIG. 4 DISPENSE VALVE |
1. |
Disconnect wires from the dispense valve. |
|
|
2. |
Drain enough water from the tank so the dispense |
Location: |
|
valve is above the water level. |
|
|
The dispense valve is located inside the top cover |
3. |
Remove water lines from the dispense valve. |
behind the front end cap. |
4. |
Remove the two #8-32 nuts securing the dispense |
|
|
|
|
valve to the sprayhead panel. |
Test Procedures: |
5. |
Install a new dispense valve using the two #8-32 |
|
1. Disconnect the brewer from the power source. |
|
nuts. |
|
2. Check the water level in the tank to confirm that it |
6. |
Reconnect water lines to the dispense valve and |
|
|
is within 1/2" from the top of the tank. |
|
secure in place with clamps. |
3. Connect the brewer to the power source. If the |
7. |
Refer to FIG. 5 when reconnecting wires. |
|
|
brewer has been set for brewer temperature lock- |
|
|
|
out, this feature must be disabled. See Page 9 for |
|
|
|
procedure. |
|
WHI/GRN from |
4. |
Check the dispense valve for coil action. Place the |
|
|
|
Control Board |
||
|
ON/OFF switch in the "ON" position, press and |
|
|
|
|
|
|
|
release the BREW switch. Listen carefully in the |
|
WHI from Terminal |
|
vicinity of the dispense valve for a "clicking" sound |
|
Block |
|
as the coil magnet attracts and repels the plunger. |
|
|
5. Disconnect the brewer from the power source. |
|
|
|
If the sound is heard as described, there may be a |
|
|
|
blockage in the dispense valve or the water line to the |
|
|
|
sprayhead. Remove the dispense valve and inspect for |
|
P1853 |
|
wear, and remove waterborne particles. |
|
||
|
FIG. 5 DISPENSE VALVE WIRING |
||
If the sound is not heard as described, proceed to #6. |
|
||
|
|
||
|
Page 24 |
29707.1 082803 |
|
|
|

SERVICE (cont.)
LIMIT THERMOSTAT
P1854 |
FIG. 6 LIMIT THERMOSTAT |
Location:
The limit thermostat is located inside the top access panel on the front side of the tank.
Test Procedures:
1.Disconnect the brewer from the power source.
2.Disconnect the blue and black wires from the limit thermostat.
3.With an ohmmeter, check for continuity across the limit thermostat terminals.
If continuity is present as described, the limit thermostat is operating properly.
If continuity is not present as described, replace the limit thermostat.
Removal and Replacement:
1.Remove the black and blue wires from limit thermostat terminals.
2.Carefully slide the limit thermostat out from under the retaining clip and remove limit thermostat.
3.Carefully slide the new limit thermostat into the retaining clip.
4.Refer to FIG. 7 when reconnecting the wires.
BLU from Control
Board
BLK from Terminal
Block
P1800
FIG. 7 LIMIT THERMOSTAT WIRING
Page 25 |
29707.1 082803 |
|

SERVICE (cont.)
TANK HEATERS
Location:
The tank heaters are located inside the tank and secured to the tank bottom.
Test Procedures :
1.Disconnect the brewer from the power source.
2.With a voltmeter, check voltage across the white or red wire from the terminal block and black wire from the control board. Connect brewer to the power source. The indication must be 120 volts ac for two wire 120 volt models or 208-240 volts ac for three wire 120/208-240 volt models.
3.Disconnect the brewer from the power source.
4.Check voltage across the red wire from the terminal block and black wire from the control board. Connect brewer to the power source. The indication must be 208 or 240 volts ac.
5.Disconnect the brewer from the power source.
If voltage is present as described, proceed to #6
If voltage is not present as described, refer to the Wiring Diagrams and check wiring harness.
6.Disconnect the black and blue wires or the red and white/violet wires from the tank heater terminals.
7.Check for continuity across tank heater terminals.
If continuity is present as described, reconnect the wires, the tank heater is operating properly.
If continuity is not present as described, replace the tank heater.
NOTE- If the tank heater remains unable to heat, remove and inspect heater for cracks in the sheath.
Removal and Replacement:
1.Remove the top cover or top warmer housing and front access panel as previously described.
2.Disconnect the vent hose from the top of the tank by pulling the elbow fitting from the grommet in the top of the tank lid.
3.Drain water from the tank.
4.Disconnect the water supply tube to the dispense valve from the side of the tank.
5.Disconnect the water supply tube to the solenoid
P1890 |
FIG. 8 TANK HEATERS |
valve from the bottom of the tank.
6.On brewers with faucet, disconnect the outlet water line to the faucet from the side of the tank.
7.Disconnect the temperature probe from the top of the tank by pulling the probe from the grommet in the top of the tank lid.
8.Disconnect the pink wire from the level probe.
9.Disconnect the green wire from the top of the tank.
10.Disconnect the limit thermostat from the side of the tank.
11.Disconnect the two white wires from the tank warmer blanket.
12.Disconnect the black, blue, white/violet and red wires from tank heater terminals.
13.Remove the four #8-32 nuts securing the tank to the mounting brackets and remove the tank assembly.
14.Remove the eight #8-32 nuts securing the tank lid to the tank.
15.Remove the two hex nuts securing the tank heater to the bottom of the tank. Remove tank heater with gaskets and discard.
16.Install new tank heater(s) with gaskets to the bottom of the tank and secure with two hex nuts.
17.Install tank assembly onto mounting brackets and secure in place with four #8-32 nuts.
18.Install tank lid and secure in place with eight #8-32 nuts.
19.Connect the two white wires of the tank warmer blanket.
Page 26 |
29707.1 082803 |
|
SERVICE (cont.)
TANK HEATERS (cont.)
20.Connect the limit thermostat to the front of the tank assembly.
21.Connect the green wire to the tank mounting bracket using #8-32 nut.
22.Connect the pink wire to the level probe.
23.Insert the temperature probe through the grommet in the tank lid.
24.Install the elbow fitting of the vent hose into the grommet in the tank lid.
25.On brewers with faucet, connect the outlet water line of the faucet to the side of the tank and secure with clamp.
26.Connect the water supply tube from the solenoid to the bottom of the tank and secure with clamp.
27.Connect the water supply tube from the dispense valve to the side of the tank and secure with clamp.
28.Refer to the Wiring Diagrams when reconnecting the tank heater wires.
29.Install access panels and covers and refer to Initial Set-up for refill and operation.
Page 27 |
29707.1 082803 |
|

SERVICE (cont.)
VOLTAGE SELECTOR SWITCH
P2503 |
FIG. 9 VOLTAGE SELECTOR SWITCH |
If continuity is not present as described, replace the voltage selector switch.
Removal and Replacement:
1.Disconnect the brewer from the power source.
2.Disconnect the three wires from the selector switch.
3.Remove the switch mounting nut from the under side of component mounting bracket; remove switch from bracket.
4.Install new switch in component mounting bracket and secure with mounting nut.
5.Refer to FIG. 10 when reconnecting wires to the switch.
Location:
The voltage selector switch is located on the component mounting bracket behind the front access panel.
Test Procedure:
1.Disconnect the brewer from the power source.
2.Disconnect the white and blue wires from the selector switch. With the selector switch in the 120V position, check for continuity between the two empty terminals of the switch.
If continuity is present as described, reconnect the white wire and continue to Step 3.
If continuity is not present as described, replace the voltage selector switch.
3.With the selector switch in the 120/208-240V position, disconnect the white/violet wire from the selector switch. check for continuity between the two empty terminals.
If continuity is present as described, the voltage selector switch is operating properly.
Page 28
WHI/VIO to Tank Heater
Blue to Tank Heater
White to Terminal Block
P2504
FIG. 10 VOLTAGE SELECTOR
SWITCH TERMINALS
29707.1 082803

SERVICE (cont.) |
|
REFILL VALVE |
If continuity is not present as described, replace the |
|
refill valve. |
|
6. Check the refill valve for coil action. Connect the brewer to the power source. With "ON/OFF" switch in the "ON' upper position press start switch and listen carefully in the vicinity of the refill valve for a" clicking" sound as the coil magnet attracts.
7. Disconnect the brewer from the power source.
If the sound is heard as described and water will not pass through the refill valve, there may be a blockage in the water line before the refill valve or, the solenoid valve may require inspection for wear, and removal of waterborne particles.
If the sound is not heard as described, replace the refill valve.
|
P1857 |
Removal and Replacement: |
|
|
|
||
|
FIG. 11 REFILL VALVE |
1. |
Remove both wires from the refill valve. |
|
|
2. |
Turn off the water supply to the brewer and drain |
Location: |
|
the tank. |
|
3. |
Disconnect the water lines to and from the refill |
||
|
The refill valve is located inside the trunk on the |
|
valve. |
lower center part of the component bracket. |
4. |
Remove the two 1/4"-20 screws securing the refill |
|
Test Procedures: |
|
valve mounting bracket to the component bracket. |
|
|
Remove bracket and valve as an assembly. |
||
1. Disconnect the brewer from the power source. |
5. |
Using two 1/4"-20 screws install the new refill |
|
2. Disconnect the white and white/blue wires from |
|
valve and bracket to the component bracket. |
|
|
the refill valve. Set the "ON/OFF" switch in the "ON" |
6. |
Securely fasten the water lines to and from the |
|
upper position. |
|
valve. |
3. With a voltmeter, check the voltage across the coil |
7. |
Refer to FIG. 12 when reconnecting the wires. |
|
|
wires. Connect the brewer to the power source. |
8. |
Install access panels and covers and refer to Initial |
|
The indication must be 120 volts ac for two wire |
|
Set-up for refill and operation. |
|
120 volt models and three wire 120/208 and 120/ |
|
|
|
240 volt models. |
|
|
4. Disconnect the brewer from the power source. |
|
|
|
If voltage is present as described, proceed to #5. |
|
|
|
If voltage is not present as described, refer to Wiring |
|
|
|
Diagrams and check brewer wiring harness. |
|
|
|
5. |
Check for continuity across the refill valve coil |
WHI from Terminal |
|
|
terminals. |
Block |
|
If continuity is present as described, reconnect the |
WHI/BLU from |
||
Control Board |
|||
white and white/blue wires from the circuit board. |
|
P1858 |
|
|
|
||
|
Page 29 |
FIG. 12 REFILL VALVE WIRING |
|
|
29707.1 082803 |
||
|
|

SERVICE (cont.)
WARMER ELEMENT(S)
|
|
|
CAUTIONARD |
NTER |
|
|
|
|
DECA |
|
|
|
|
|
|
|
|
|
|
|
DISC |
|
|
|
|
|
! IF: |
|
|
|
FIG. 13 WARMER ELEMENTS |
P1859 |
|||
|
|
||||
Location: |
|
|
|
|
|
The |
warmer |
element(s) |
is |
located |
under the |
warmer plate. |
|
|
|
|
Test Procedures:
1.Disconnect the brewer from the power source.
2.With a voltmeter, check voltage across the two wires at the warmer element with the "ON/OFF" switch in the "ON" position. Connect the brewer to the power source. The indication must be 120 volts ac for two wire 120 volt models and three wire 120/208 and 120/240 volt models.
3.Disconnect the brewer from the power source.
If voltage is present as described, proceed to #4.
If voltage is not present as described, refer to Wiring Diagrams and check brewer wiring harness.
4.Check the continuity across the two terminals on the warmer element.
If continuity is present as described, reconnect the two wires to the warmer element.
If continuity is not present as described, replace the warmer element.
Removal and Replacement:
1.Remove the three #4-40 screws securing the warmer assembly to the brewer.
2.Lift the warmer assembly from the brewer.
3.Disconnect the two wires from the warmer element terminals.
4.Remove the two #8-32 nuts securing the warmer element to the warmer plate.
5.Securely install new warmer element.
6.Reconnect the two wires to warmer element terminals.
7.Securely install warmer assembly on the brewer.
8.Refer to the Wiring Diagrams when reconnecting the wires.
Page 30 |
29707.1 082803 |
|

SCHEMATIC WIRING DIAGRAM CDBC DV
L1 |
N L2 |
GRN
|
|
|
|
|
|
|
|
SELECTOR |
|
|
|
|
|
|
|
LIMIT |
|
|
|
|
SWITCH |
WHI-14 |
|
|
|
|
|
|
|
TANK HEATER |
|
|
|
|
|
|
|
|
|||
|
|
THERMOSTAT |
|
BLU-14 |
|
|
|
|
|
|
|
||
|
|
BLK-14 |
|
|
|
|
TANK HEATER |
|
|||||
|
|
BLK-14 |
BLU-14 |
1425W |
|
|
|
|
WHI/VIO-14 |
RED-14 |
|||
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
"KEEP WARM" HEATER |
|
|
|
|
|
2268W |
|
||
|
|
WHI |
|
|
|
|
|
|
|
|
|
WHI |
|
|
|
|
|
|
|
|
|
|
|
|
|
||
BLK |
|
|
|
|
|
|
|
BREW STATION WARMER |
|
|
|||
|
|
|
|
|
|
WHI/RED |
(CONTROLLED BY ON/OFF SW) |
|
WHI |
||||
|
|
COUNTER |
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
REFILL |
|
|||
|
|
(OPTIONAL) |
|
|
|
|
|
|
|
WHI |
|||
|
J1-1 |
BLK |
|
|
|
|
|
|
WHI/BLU |
|
SOL |
||
C |
BLK |
|
|
|
|
|
DISPENSE |
|
|
|
|||
J1-2 |
|
|
|
|
|
|
|
|
|
||||
O |
COM |
BLU-14 |
|
|
WHI/GRN |
SOL |
|
|
|
|
WHI |
||
N |
N.O. |
BLK-14 |
|
|
|
|
|
|
|
|
|
|
|
T |
WHI |
|
|
|
|
|
|
|
|
|
|
WHI |
|
R |
J1-1 |
|
|
|
|
|
WARMER ASSY "A" |
|
|
|
|||
O |
BLK |
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
||||
L |
|
BRN/BLK |
|
|
|
P2 |
|
|
FRONT WARMER |
|
P1 |
|
WHI |
|
|
|
BRN/BLK |
|
BRN/BLK |
WHI |
|
||||||
P |
|
|
|
|
|
||||||||
J1-5 |
WHI/BLU |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
C |
WHI/RED |
|
|
|
|
(SEE TABLE BELOW FOR USAGE) |
W |
|
P1, P2, & |
||||
|
|
|
|
|
|
||||||||
|
|
YEL |
|
|
|
|
H |
|
P3 ARE |
||||
B |
|
WHI/VIO |
|
|
|
P3 |
|
|
REAR WARMER |
I |
|
||
|
|
VIO |
|
|
VIO |
|
PINS OF A |
||||||
O |
|
VIO |
|
|
|
|
|
|
|
POLARIZED |
|||
A |
|
WHI/GRN |
|
|
|
|
|
|
|
|
|
||
J1-10 |
|
|
|
|
|
|
|
|
|
THREE-PIN |
|||
R |
CONTROL PANEL ASSY |
|
|
|
WARMER ASSY "B" |
|
|
||||||
D |
|
|
|
|
|
|
CONNECTOR. |
||||||
|
J2-1 |
BREW SW |
LT FRNT SW |
LT REAR SW |
|
P2 |
|
YEL |
FRONT WARMER |
WHI |
P1 |
|
WHI |
|
|
|
|
YEL |
|
|
|
|
|
|
|
ON/OFF |
SW |
TOP FRNT SW |
TOP REAR SW |
|
(SEE TABLE BELOW FOR USAGE) W |
|||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
P3 |
|
|
|
REAR WARMER |
|
H |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
J2-6 |
|
|
|
|
|
|
|
|
WHI/VIO |
WHI/VIO |
|
|
|
I |
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
||||||||||||
|
HIDDEN SW |
RT REAR SW |
RT FRNT SW |
|
|
|
|
|
|
|
|||||||||||
|
|
WARMER WIRING REFERENCE |
|||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(ALL CONFIGURATIONS INCLUDE BREW STATION WARMER) |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
J2-11 |
|
STATIC |
(NOTE – ALL WARMERS ARE NOT |
|
SHIELD |
AVAILABLE ON ALL MODELS!) |
|
|
J3-1 |
PNK |
|
GRN |
|
|
|
|
|
|
WHI |
LEVEL |
J3-4 |
BLK |
|
|
PROBE |
|
|
|
|
J5-1 |
BLK |
|
|
|
|
|
|
t° |
29685.0004B 02/04 ©2003 BUNN-O-MATIC CORPORATION
|
LEFT |
TOP |
RIGHT |
WITH TOP WARMERS |
– |
"A" |
– |
WITH LEFT WARMERS |
"B" |
– |
– |
WITH RIGHT WARMERS |
– |
– |
"A" |
WITH LEFT & RIGHT WARMERS |
"B" |
– |
"A" |
WITH LEFT & TOP WARMERS |
"B" |
"A" |
– |
WITH RIGHT & TOP WARMERS |
– |
"A" |
"B" |
|
|
|
|
120V AC 2 WIRE 120/208V AC 3 WIRE 120/240V AC 3 WIRE SINGLE PHASE
Page 31 |
29707.1 021804 |
|

SCHEMATIC WIRING DIAGRAM CDBC APS-DV
CDBCF APS/TC/LPTC-DV
L1 |
|
|
|
|
GRN |
|
|
N |
L2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
SELECTOR |
|
|
|
|
LIMIT |
|
|
|
|
SWITCH |
|
|
|
|
|
TANK HEATER |
|
WHI-14 |
|
|
||
|
|
THERMOSTAT |
|
BLU-14 |
|
|
|
||
|
|
BLU-14 |
BLK-14 |
|
|
TANK HEATER |
|
||
|
|
BLK-14 |
|
|
|
WHI/VIO-14 |
|
||
|
|
|
1425W |
|
RED-14 |
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
"KEEP WARM" HEATER |
|
|
2268W |
|
|
|
|
WHI |
|
|
|
WHI |
|
||
|
|
|
|
|
|
|
|
||
BLK |
|
|
|
|
|
|
|
|
|
|
|
COUNTER |
|
|
|
|
|
|
|
|
|
(OPTIONAL) |
|
|
|
|
|
|
|
|
J1-1 |
BLK |
|
|
|
|
|
|
|
C |
BLK |
|
|
|
|
|
|
|
|
J1-2 |
|
|
|
|
|
|
|
||
BLU-14 |
|
|
|
|
|
|
|
||
O |
COM |
|
|
|
|
|
|
|
|
N |
BLK-14 |
|
|
|
|
|
|
|
|
N.O. |
|
|
|
|
|
|
|
||
T |
WHI |
|
|
|
|
|
WHI |
|
|
R |
J1-1 |
|
|
|
|
|
|
||
O |
BLK |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
L |
|
|
|
|
REFILL |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
P |
J1-5 |
WHI/BLU |
|
WHI/BLU |
SOL |
|
|
WHI |
|
C |
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
B |
|
|
|
|
|
|
DISPENSE |
|
|
O |
|
|
|
|
|
|
|
WHI |
|
A |
J1-10 |
WHI/GRN |
|
|
|
WHI/GRN |
SOL |
|
|
R |
CONTROL PANEL ASSY |
|
|
|
|
|
|
||
D |
|
|
|
|
|
|
|
|
|
|
J2-1 |
BREW SW |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ON/OFF SW |
|
|
|
|
|
|
|
|
J2-6 |
HIDDEN SW |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
J2-11 |
STATIC |
|
|
|
|
|
|
|
|
SHIELD |
|
|
|
|
|
|
|
|
|
J3-1 |
PNK |
|
|
|
|
120V AC 2 WIRE |
|
|
|
|
GRN |
|
|
|
120/208V AC 3 WIRE |
|
|
|
|
|
WHI |
LEVEL |
|
|
|
|
||
|
J3-4 |
BLK |
|
|
120/240V AC 3 WIRE |
|
|
||
|
PROBE |
|
|
|
|
||||
|
|
|
|
|
|
SINGLE PHASE |
|
|
|
|
|
BLK |
|
|
|
|
|
|
|
|
J5-1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
t° |
|
|
|
29685.0005B 02/04 ©2003 BUNN-O-MATIC CORPORATION |
|
Page 32 |
29707.1 021804 |
|