MODEL C500
MODEL C501CY
MODEL C501K
READ AND SAVE THESE INSTRUCTIONS
INSTALLATION
ALL ELECTRICAL WORK MUST BE DONE IN ACCORDANCE WITH LOCAL AND/ OR NATIONAL ELECTRICAL CODE AS APPLICABLE.
TURN OFF POWER AT SERVICE ENTRANCE BEFORE INSTALLING, WIRING, OR SERVICING THIS PRODUCT.
1.Hold chime mechanism against wall and mark four (4) mounting holes.
2.Drill 3/16” holes where marked and tap in wall anchors from parts bag.
3.Bring wiring through access hole(s) in chime mechanism backplate.
4.Attach chime mechanism to wall with screws from parts bag. Tighten screws securely.
5.Hang chime tubes from mechanism as shown.
DO NOT OIL CHIME PLUNGERS.
Oil will cause them to stick during operation. If plungers fail to operate freely due to accumulation of dust, cooking grease, etc., clean with a non-flammable cleaning solvent which will evaporate, leaving a dry surface.
INSTALLATION (continued)
6. Connect wires to appropriate terminals.
RECOMMENDED NEW CONSTRUCTION WIRING |
|
|
||||
Ground |
|
|
|
|
|
|
120 Volt AC |
|
|
|
|
|
|
|
|
|
|
|
|
Lighted or |
|
|
|
|
|
|
Unlighted Buttons |
16 VAC |
|
|
Front |
Side |
|
Rear |
|
|
|
|
|
|
|
Transformer |
|
|
|
|
|
|
1 |
2 |
3 |
F |
S |
R |
NOT USED |
Nine volt |
|
|
|
|
|
|
batteries |
|
|
|
|
|
|
not used |
|
|
|
|
|
|
Volume Control |
|
|
|
|
|
REPLACING EXISTING 2-NOTE CHIME |
|
|
|
|
|||
Ground |
|
|
|
|
|
|
|
120 Volt AC |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Lighted or |
|
|
|
|
|
|
|
Unlighted Buttons |
|
16 VAC |
|
|
Front |
Side |
|
Rear |
|
|
|
|
|
|
|
|
|
Transformer |
|
|
|
|
|
|
|
1 |
2 |
3 |
F |
S |
R |
NOT USED |
9V |
9V |
|
|
|
|
|
|
Requires Two |
|
|
|
|
|
|
|
9 Volt Batteries |
|
|
|
|
|
|
|
|
Volume Control |
|
|
|
|
|
7.Install two (2) alkaline 9-volt batteries, if appropriate for your application. Turn on power at service entrance. Make sure pushbuttons operate chime properly. (Adjust switch on circuit board for 4 or 8 chime tones at front door. Side and rear doors will have 1 chime tone each.)
8.Adjust chime volume with stem on circuit board assembly. If plunger(s) fail to strike tube(s), move tube(s) one notch closer. If plunger(s) strike a double tone, move tube(s) one notch out.
9.Hook cover over chime mechanism.
2