LOSONE SELECT® VENTILATORS
Ceiling/Wall Mount
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCETHE RISK OF FIRE,ELECTRIC SHOCK,OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1.Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
2.Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3.Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
4.Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
5.When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6.Ducted fans must always be vented to the outdoors.
7.To reduce the risk of fire, use only metal ductwork.
8.Models L100, L150, L200, L250, and L300 only:
If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Interrupter) - protected branch circuit.
9.Never place a switch where it can be reached from a tub or shower.
10.This unit must be grounded.
CAUTION !
1.For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2.To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
3.Please read specification label on product for further information and requirements.
COOKING AREA |
|
Do not install above or |
|
|
inside this area. |
45o |
45o |
NOT FOR USE IN |
Cooking |
A COOKING AREA. |
|
|
Equipment |
|
Floor |
TYPICAL INSTALLATION
MOUNTING (New Frame Construction)
ROUND DUCT* |
Mounting brackets |
|
|
|
factory-shipped in |
|
position for ½” ceil- |
|
ing material. |
ADDITIONAL |
|
1½” FRAMING |
CEILING JOIST |
|
(16” centers shown) |
Blower factory-shipped |
MOUNTING |
in horizontal |
SCREW |
discharge position. |
|
GRILLE |
|
(Polymeric |
|
shown) |
|
Install after |
GRILLE |
ceiling is |
|
finished. |
SCREW |
Factory-shipped unit installed in new construction.
MOUNTING (Existing Frame Construction)
2 X 4 FRAMING |
|
(wide side down) |
|
ROUND DUCT* |
|
CEILING JOIST |
|
(16” centers |
|
shown) |
|
MOUNTING |
|
BRACKETS |
FINISHED |
(Attached to |
|
opposite sides |
CEILING |
of housing & up- |
MATERIAL |
side-down, |
|
so housing is |
|
flush with |
|
finished ceiling) |
|
GRILLE |
GRILLE |
(Polymeric shown) |
SCREW |
Factory-shipped unit installed in existing construction.
* L100 & L150 Series uses 6” Round Duct.
1 L200, L250, & L300 Series uses 8” Round Duct.
TYPICAL INSTALLATION
WIRING |
|
BLACK |
|
TO |
TOP / BACK |
BLACK |
|
|
OF HOUSING |
|
GROUND TO |
|
WIRING PLATE |
|
WIRING |
|
PLATE |
WHITE |
|
TO |
|
WHITE |
|
|
LINE IN |
Ventilator can be wired from outside of housing. Use UL approved connectors to wire per local codes.
DUCTING (Horizontal blower discharge)
ROOF CAP
ROUND
DUCT*
|
WALL |
ROUND |
CAP |
ELBOW* |
|
Two ways to connect ductwork to a factory-shipped unit.
*L100 & L150 Series uses 6” Round Duct.
L200, L250, & L300 Series uses 8” Round Duct.
IMPORTANT:
Remove shipping tape from damper
Remove the shipping tape from the damper flap and make sure that damper flap opens and closes freely inside the ductwork. Use duct tape to make ductwork connections secure and air-tight.
Remove shipping ring from blower inlet
Remove the shipping ring from the blower inlet before operating the ventilator.
MOUNTING OPTIONS
¼-20 hex nuts secure mounting brackets to housing. Loosen and re-tighten or remove and replace nuts as necessary for desired mounting bracket position.
11/8" |
1½" |
to |
|
MAX. |
2½" |
12¼" |
12¼" |
Mounting brackets in |
Mounting brackets flipped |
factory-shipped position. |
over and mounted to outlet |
(Outlet parallel to joists.) |
sides of housing. |
(New construction) |
(Outlet parallel to joists.) |
|
(Existing construction) |
|
11/2" |
|
to |
|
21/2" |
12¼" |
12¼" |
Mounting brackets mounted |
Mounting brackets flipped |
to outlet sides of housing. |
over to give approx. 1” |
(Outlet perpendicular to joists.) |
more clearance. |
(New construction) |
(Outlet parallel to joists.) |
|
(New construction) |
91/2" |
10 3/4" |
|
to |
||
to |
||
11 3/4" |
||
101/2" |
||
12¼" |
12¼" |
Mounting brackets mounted |
Mounting brackets flipped |
to top of sides of housing. |
over and mounted to top of |
(Outlet parallel to joists.) |
sides of housing. |
(New or existing construction) |
(Outlet parallel to joists.) |
|
(New or existing construction) |
WIRING OPTIONS
WIRING PLATE
POSITION
VERTICAL
POWER CABLE
CONNECTION
HORIZONTAL POWER
CABLE CONNECTION
Wiring plate mounts to side or top of housing.
2
DUCTING OPTIONS
BLOWER DISCHARGE POSITIONS |
DUCTING (Vertical blower discharge) |
DUCT |
ROOF CAP |
CONNECTOR |
|
|
ROUND |
|
DUCT* |
DUCT |
Change |
|
CONNECTOR |
blower & |
|
duct connec- |
|
|
|
* L100 & L150 Series uses 6” Round Duct. |
|
|
tor positions |
|
|
for vertical |
L200, L250, & L300 Series uses 8” Round Duct. |
|
discharge. |
|
|
Typical ductwork connection to a ventilator converted to |
|
|
|
|
BLOWER |
|
vertical discharge. |
BLOWER |
|
|
|
|
Blower and duct connector |
Blower and duct connec- |
in horizontal discharge |
tor in vertical discharge |
position. (Factory shipped) |
position. |
USE AND CARE
Ventilator is designed for continuous operation. If desired, it may be controlled using an on/off switch or a solid-state, variable speed control. Follow wiring instructions packed with control, and adhere to all local and state codes, and the National Electrical Code.
WARNING: To reduce the risk of electric shock, disconnect from power supply before servicing.
To clean grille: Use appropriate vacuum attachment or remove grille and clean with a soft cloth and mild soap or detergent. Dry grille thoroughly before reinstalling.
To clean blower assembly: Remove grille, unplug blower from housing, remove blower mounting nuts, and carefully remove blower from housing. Use appropriate vacuum attachment or a soft cloth and mild soap or detergent to clean blower discharge area and wheel. DO NOT ALLOW WATER TO ENTER MOTOR. Make sure blower assembly is completely dry before reinstalling.
Motor is permanently lubricated. Do not oil or disassemble motor.
VENTILADORES LOSONE SELECT®
Para montaje en cielo raso/pared
LEA Y CONSERVE ESTAS INSTRUCCIONES
ADVERTENCIA
PARA REDUCIR EL RIESGO DE INCENDIO, GOLPE ELÉCTRICO, O LESIÓN A PERSONAS, OBSERVE LO SIGUIENTE:
1.Use esta unidad solamente de la manera indicada por el fabricante. Si tiene preguntas, póngase en contacto con el fabricante a la dirección o teléfono que aparecen en la garantía.
2.Antes de limpiar o de poner en servicio la unidad, apague el interruptor en el panel de servicio, y asegure el panel de servicio para evitar que se encienda accidentalmente. Cuando el dispositivo para desconectar el servicio eléctrico no puede ser cerrado con algún tipo de traba, sujete fuertemente al panel de servicio, una etiqueta de advertencia prominente.
3.El trabajo de instalación y cableado eléctrico deben estar hechos por personal capacitado de acuerdo con todos los códigos y estándares aplicables, incluyendo códigos y estándares de construcción a prueba de incendios.
4.Se necesita suficiente aire para la combustión y extracción de gases por la chimenea del equipo que quema combustible para evitar la retrogresión de las llamas.Siga las directrices del fabricante y estándares de seguridad como los publicados por la Asociación Nacional de Protección Contra Incendios (o por sus siglas en inglés NFPA), y la Sociedad Americana de Ingenieros de Calefacción, Refrigeración, y Aire Acondicionado (o por sus sigles en inglés ASHRAE), y los códigos de las autoridades locales.
5.Cuando corte o taladre en una pared o cielo raso, no dañe cableado eléctrico o instalaciones no visibles.
6.Ventiladores con conductos siempre deben extraer hacia el exterior.
7.Para reducir el riesgo de incendio, use sólo ductos de metal.
8.Modelos L100, L150, L200, L250, y L300 solamente:
Si esta unidad va a instalarse sobre una bañera o ducha, debe marcársela como correcta para dicha aplicación y debe conectarse a un protegido GFCI (Cortacicuito Accidental a Tierra).
9.Nunca instale un interruptor donde se pueda alcanzar desde una bañera o ducha.
3 10. Esta unidad se debe conectar a tierra.