Broan QP230WW, QP230SS, QP230BC, QP236BC, QP242SS User Manual 2

...
4 (1)

MODELS QP230BC • QP230BL • QP230SS • QP230WW

QP236BC • QP236BL • QP236SS • QP236WW

QP242BC • QP242BL • QP242SS • QP242WW

EVOLUTION

2

Page 1

TM

 

QP2 Series Range Hoods

 

READ AND SAVE THESE INSTRUCTIONS

FOR DOMESTIC COOKING ONLY

WARNING

 

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1.Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.

2.Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

3.Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.

4.Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society of Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

5.This product may have sharp edges. Be careful to avoid cuts and abrasions during installation and cleaning.

6.When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

7.Ducted fans must always be vented to the outdoors.

8.Use only metal ductwork.

9.Do not use this fan with any solid-state speed control device.

10.As an alternative, this product may be installed with the ULapproved cord kit designated for the product, following instructions packed with the cord kit.

11.This unit must be grounded.

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

1.Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.

2.Always turn hood ON when cooking at high heat or when flambéing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).

3.Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.

4.Use proper pan size. Always use cookware appropriate for the size of the surface element.

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*

1.SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.

2.NEVER PICK UP A FLAMING PAN — You may be burned or spread the fire.

3.DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result.

4.Use an extinguisher ONLY if:

A.You know you have a Class ABC extinguisher, and you already know how to operate it.

B.The fire is small and contained in the area where it started.

C.The fire department is being called.

D.You can fight the fire with your back to an exit.

* Based on “Kitchen Firesafety Tips” published by NFPA.

CAUTION

1.For indoor use only.

2.For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.

3.To avoid motor bearing damage and noisy and/or unbalanced impeller, keep drywall spray, construction dust, etc., off power unit.

4.Do not use over cooking equipment greater than 60,000 BTU/hr. as the blower motor will shut down intermittantly.

5.Your hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated. The motor will restart when it cools down. If the motor continues to shut off and restart, have the hood serviced.

6.The top of the hood MUST NOT BE LESS than 24” and at a maximum of 30” above cooktop for best capture of cooking impurities.

7.This hood is not intended to be used as a shelf.

8.Please read specification label on product for further information and requirements.

NOTE

If hood is to be installed non-ducted:

Purchase a set of (2) non-ducted filters for 30” wide hoods (Model BPPF30) & 36” wide hoods (Model BPPF36) or a set of (3) non-ducted filters for 42” wide hoods (Model BPPF42) from your local distributor or retailer and attach them to the aluminum mesh filters.

Register your product online at: www.broan.com

Installer: Leave this manual with the homeowner.

Homeowner: Cleaning, Maintenance and Operating instructions on page 2.

MODELS QP230BC • QP230BL • QP230SS • QP230WW QP236BC • QP236BL • QP236SS • QP236WW QP242BC • QP242BL • QP242SS • QP242WW

Page 2

CONTENTS

INCLUDED WITH THE HOOD:

 

(1) 3¼” X 10”

 

DAMPER / DUCT

 

CONNECTOR

GREASE

 

FILTERS

 

(2 - FOR 30” & 36” HOODS)

3 - FOR 42” HOODS)

 

(4)

(1) 7” ROUND

DUCT

HALOGEN

CONNECTOR

BULBS

 

(1) PARTS BAG CONTAINING:

(3) WIRE NUTS

(9)

#8 X 1/4” DUCT

CONNECTOR

SCREWS

(1) BULB

SUCTION

CUP TOOL

(5) #10 X 5/8” RD. HD. MOUNTING SCREWS

(1) NON-DUCT DIVERTER

(2) #8 X 5/16” MACHINE

SCREWS &

(2)

#8 WASHERS

FOR NON-DUCT

DIVERTER

CLEANING & MAINTENANCE

For performance, appearance, and health reasons, clean filter, fan and grease-laden surfaces. Use only a clean cloth and mild detergent solution on stainless and painted surfaces.

Clean all-metal filters in the dishwasher using a non-phosphate detergent. Discoloration of the filter may occur if using phosphate detergents, or as a result of local water conditions - but this will not affect filter performance. This discoloration is not covered by the warranty.

Clean the non-duct recirculating filter surfaces frequently with a damp cloth and a mild detergent. DO NOT immerse filters in water or put in dishwasher.The special “Clean Sense” feature indicates when the filter is to be replaced.The dotted lines on the indicator strip will change to solid wide lines when it is time to change the filter. The “Clean Sense” feature works best when facing toward the cooking surface. Change the non-duct recirculating filters every 6 months. For replacement non-duct recirculating filters - purchase S99010353 or Model BPPF30 for 30 wide hoods”, S99010354 or Model BPPF36 for 36” wide hoods, or S99010360 or Model BPPF42 for 42” wide hoods.

The motor is permanently lubricated and never needs oiling. If the motor bearings make excessive or unusual noise, replace the motor with the exact service motor. The impeller should also be replaced.

Use 120 V, 50 W, shielded halogen bulbs - MR16 with GU10 base.

OPERATION

Always turn the hood ON before cooking in order to establish an air flow in the kitchen. After turning off the range, let the hood run for a few minutes to clear the air.

Operate the hood as follows:

LIGHT (3 pushbutton switches)

Turns light on to LOW setting.

Turns light on to MEDIUM setting.

Turns light on to HIGH setting.

Pressing the same light button again will turn lights OFF. A light above each button indicates light setting.

FAN (3 pushbutton switches)

Turns fan on to LOW speed.

Turns fan on to MEDIUM speed.

Turns fan on to HIGH speed.

Pressing the same fan button again will turn fan OFF. A light above each button indicates fan speed.

NOTE

This hood utilizes an offset blower design to achieve greater performance and lower sound levels. As a result, you may notice that cooking impurities are more attracted to one side or appear to be pulled-in faster than they appear on the opposite side. This is completely normal. The hood has been designed and tested to provide good capture of cooking impurities and odors under all normal cooking conditions regardless of the cooking location on the cooktop. Please note that cooking on the rear burners will always result in the best capture of cooking impurities, regardless of the hood design.

HEAT SENTRY SYSTEM

This range hood is equipped with an advanced Heat Sentry system that monitors for excessive temperature and automatically adjusts the fan to the appropriate setting.

1)If the fan is on, the Heat Sentry system will increase the fan setting when the temperature is elevated. If the temperature continues to rise, the Heat Sentry system will continue to increase the fan setting until the temperature is stabilized or reduced.The flashing light above the fan button shows the Heat Sentry system fan setting. Once the temperature has reduced, the Heat Sentry system will change the fan to the original setting.

2)If the fan is off, the Heat Sentry system will automatically turn the fan on to its highest speed when the temperature is above normal. When the Heat Sentry system is on, the light above the high speed fan button will flash on and off. After the temperature has lowered to normal, the fan speed will be reduced until the temperature has stabilized, then the fan will turn off.

Note: Canadian version does not have this function.

MODELS QP230BC • QP230BL • QP230SS • QP230WW QP236BC • QP236BL • QP236SS • QP236WW QP242BC • QP242BL • QP242SS • QP242WW

Page 3

FUSE

 

FUSE

RANGE HOOD CONTROL BOARD

The Range Hood Control Board contains a Fuse to protect the controls from power surges. If the fuse has opened (blown), the green fan setting or light setting indicators will not operate properly when the fan or light buttons are pressed, and the fan and lights will not turn on.

A new fuse can be purchased at your local electronic supply store. Use an 8A, 120V, 5 mm diameter, 20 mm long, fast-acting, cartridge-type fuse.

To replace the fuse (by qualified person(s):

1.Disconnect power at service entrance.

2.Remove filters and bottom pan.

3.Remove and inspect fuse. If it is not open (blown), additional diagnostics are needed.

PREPARE HOOD LOCATION

ROOF CAP

3¼" X 10" or

 

7" ROUND DUCT

 

(For vertical

 

discharge)

SOFFIT

 

 

HOUSE WIRING

CABINET

(Top or Back of hood)

 

WALL CAP

HOOD

 

24" - 30" ABOVE

3¼" X 10" DUCT

COOKING SURFACE

(For horizontal discharge)

 

1 Determine whether hood will discharge vertically (3¼”

x 10” or 7” Round), or horizontally (3¼” x 10” only). For

vertical or horizontal discharge, run ductwork between

the hood location and a roof cap or wall cap. For best

results, use a minimum number of transitions and

elbows.

 

2

Use the proper diagram below, for placement of ductwork

 

and electrical cutout in cabinet or wall. For a non-ducted

 

installation, DO NOT cut a duct access hole.

 

 

 

 

 

 

 

 

 

3¼” X 10”

HOOD MOUNTING SCREWS (5)

VERTICAL DUCTING

 

 

 

11

5/8" (30" hood)

11

5/8"

(30" hood)

 

 

14

5/8" (36" hood)

 

 

 

14

5/8" (36" hood)

 

 

 

 

 

 

17

5/8" (42" hood)

17

5/8" (42" hood)

 

 

CABINET FRONT

 

 

 

 

 

 

 

CABINET

* 67/8"

 

 

 

 

BOTTOM

 

 

 

 

5¼"

5¼"

11"

21/8"

107/8"

4½"

VERTICAL DUCT

 

ACCESS HOLE

 

 

 

¾"

 

 

 

25/8"

 

 

 

 

 

ELECTRICAL

WOOD SHIMS

CENTER

ACCESS HOLE

(recessed-bottom

(in cabinet bottom)

LINE

cabinets only)

 

 

 

 

 

WOOD SHIMS

 

 

 

3¼” X 10”

 

 

HORIZONTAL DUCTING

(recessed-bottom

 

 

 

 

 

 

cabinets only)

CABINET FRONT

13/8"

 

 

 

 

 

 

3/8"

 

 

4"

 

*

 

 

 

 

HORIZONTAL DUCT

 

CABINET

 

ACCESS HOLE

 

 

BOTTOM

 

5¼"

5¼"

 

 

 

 

 

 

67/8"

11

5/8" (30" hood)

11

5/8" (30" hood)

14

5/8" (36" hood)

14

5/8" (36" hood)

17

5/8" (42" hood)

17

5/8" (42" hood)

HOOD

 

CENTER

 

ELECTRICAL

MOUNTING

 

 

SCREWS (5)

 

LINE

 

ACCESS HOLE

 

 

 

 

(in wall)

 

 

 

 

 

 

HOOD MOUNTING SCREWS (5)

 

 

7-IN. ROUND

 

 

DUCTING

11

5/8" (30" hood)

11

5/8" (30" hood)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14

5/8" (36" hood)

 

 

 

 

 

 

 

14

5/8" (36" hood)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17

5/8" (42" hood)

17

5/8" (42" hood)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8" DIA.

*

 

 

 

HOLE

67/8"

 

 

7-IN.ROUND

 

 

107/8"

 

DUCT

11"

21/8"

45/8"

ACCESS

 

HOLE

 

 

25/8"

 

 

 

 

ELECTRICAL

ACCESS HOLE (in cabinet bottom)

*Note the extra wood shim and mounting screw near the cabinet front, on the cabinet center line.

Broan QP230WW, QP230SS, QP230BC, QP236BC, QP242SS User Manual 2

MODELS QP230BC • QP230BL • QP230SS • QP230WW QP236BC • QP236BL • QP236SS • QP236WW QP242BC • QP242BL • QP242SS • QP242WW

Page 4

PREPARE THE HOOD

3

Remove parts bag

 

from the hardware

 

box included with

 

the hood.

4

Remove all

 

protective polyfilm

 

from the hood

 

(stainless steel

 

hoods only).

5

Remove the

 

Aluminum Filters

 

from the hood.

 

 

ç

 

 

(1)

(2)

ç

PULL

DOWN

 

LIFT

ALUMINUM

OUT

FILTERS

 

 

6 Remove 6 Screws holding Bottom Pan to hood. Set bot- tom pan and screws aside.

SCREWS

NON-DUCT

PLATE

 

NON-DUCT

 

PLATE

SLOT

ç

 

 

NON-DUCT

 

PLENUM

DAMPER /

DUCT CONNECTOR

7 Remove 2 Screws holding Damper / Duct Connector

to hood. Remove damper/duct connector from inside the hood.

FOR DUCTED INSTALLATIONS - Skip to Step 12.

NON-DUCT

DIVERTER

8 NON-DUCTED INSTALLATION ONLY:

From parts bag: Attach Non-Duct Diverter to Air Box with 2 Screws and 2 Washers.

9 NON-DUCTED INSTALLATION ONLY:

Remove 2 Screws holding Non-Duct Plate to Non-Duct Plenum and remove plate.

SCREWS

NON-DUCT

PLATE

10 NON-DUCTED INSTALLATION ONLY:

Insert short end of Non-Duct Plate into Non-Duct Plenum Slot. Attach with 2 Screws removed in Step 9.

11 NON-DUCTED INSTALLATION ONLY:

Purchase a set of (2) non-ducted filters for 30” wide hoods (Model BPPF30) & 36” wide hoods (Model BPPF36) or

a set of (3) non-ducted filters for 42” wide hoods (Model BPPF42) from your local distributor or retailer. Attach the non-ducted filters to the aluminum mesh filters following instructions packed with the non-ducted filters.

FOR NON-DUCTED INSTALLATIONS - Skip to “INSTALL THE HOOD”.

MODELS QP230BC • QP230BL • QP230SS • QP230WW QP236BC • QP236BL • QP236SS • QP236WW QP242BC • QP242BL • QP242SS • QP242WW

Page 5

7” ROUND

KNOCKOUT

PLATE (also remove 3¼” x 10” vertical plate)

 

3¼” X 10”

 

VERTICAL

 

KNOCKOUT

3¼” X 10”

PLATE

HORIZONTAL

 

KNOCKOUT

 

PLATE

 

12

DUCTED INSTALLATION ONLY:

 

Remove 3¼” x 10 vertical, 3¼” x 10” horizontal, or 7-inch

round knockout plate(s) as appropriate for your ducting

method.

 

 

3¼” X 10”

 

DAMPER /

 

DUCT

 

CONNECTOR

TOP/BACK

 

EDGE OF

DAMPER

HOOD

 

FLAP

 

PIVOT

 

7” ROUND

 

DUCT

 

PLATE

13

DUCTED INSTALLATION ONLY:

 

Attach 3¼” x 10” Damper/Duct Connector (if using 3¼”

 

x 10” duct) or 7” Round Duct Plate (if using 7-inch round

duct) over the knockout opening.

Notes:

To accomodate off-center ductwork, the 3¼” x 10” damper/duct connector can be installed up to ½” on either side of the hood center and the 7” round duct plate can be installed up to ½” on either side of the hood center.

Install the 3¼” x 10” Damper/Duct Connector with the

Damper Flap Pivot nearest the Top/Back Edge of Hood.

INSTALL THE HOOD

WARNING

To reduce the risk of electrical shock, switch power off at service panel. Lock or tag service panel to prevent

power from being switched on accidentally.

ELECTRICAL

WIRING BOX

COVER

ELECTRICAL

POWER

CABLE

KNOCKOUT

14 Remove Electrical Wiring Box Cover from inside of hood and appropriate Electrical Power Cable

Knockout from top or back of hood.

HOUSE

POWER CABLE

15

Run House Power Cable between service panel and hood

 

location. Attach power cable to hood using appropriate clamp.

16

Hang hood from (4) mounting screws driven part-way into

 

cabinet locations (shown in illustrations under “PREPARE

 

HOOD LOCATION”). Mounting screws are included in parts

 

bag. Slide hood back towards wall until mounting screw

 

heads are engaged in narrow end of keyhole slots in top of

 

hood. Tighten screws securely. Add 5th mounting screw in

 

center hole in hood and tighten securely.

17

DUCTED INSTALLATION ONLY:

 

Connect ductwork to hood and use duct tape to make joints

 

secure and air-tight. Make sure the damper / duct connector

 

enters the ductwork and that the damper opens and closes

 

freely.

MODELS QP230BC • QP230BL • QP230SS • QP230WW QP236BC • QP236BL • QP236SS • QP236WW QP242BC • QP242BL • QP242SS • QP242WW

CONNECT THE WIRING

GROUND

SCREW

HOUSE

POWER CABLE

18 Connect House Power Cable to range hood wiring - BLACK to BLACK, WHITE to WHITE, and GREEN or

BARE WIRE to Ground Screw. Replace electrical wiring box cover.

19 Re-attach Bottom Pan with 6 Screws removed in Step 6.

Page 6

LAMP SOCKET

BRACKET

LIGHT

SCREWS

PANEL

To change the depth of bulb sockets:

-Remove bottom pan (See Step 6).

-Remove 2 Light Panel Screws and Light Panel. Set

screws aside.

-Loosen 2 Screws holding Lamp Socket Bracket to Light Panel.

-Adjust socket/bracket to desired depth.

-Re-tighten screws securely.

-Re-attach light panel and bottom pan.

INSTALL LIGHT BULBS

 

SUCTION

 

CUP TOOL

HALOGEN

(1)

PUSH IN

BULB

 

(2)

 

ROTATE

 

CLOCKWISE

 

LIGHT PANEL

 

SCREWS

LIGHT PANEL

 

CAUTION: Bulbs may be hot. Refer to bulb packaging for further information.

20 Install (4) Halogen Bulbs (included with hood). Use 120 V, 50 W, shielded halogen bulbs - MR16 with GU10 base.

NOTE: Suction Cup Tool (included with hood) can be used to install and remove light bulbs.

Align pins on bulb with large diameter opening on socket, then push bulb in towards hood and rotate clockwise until firmly seated.

The position of the bulb socket (depth) is adjustable and may require adjustment when:

a)certain brands of bulbs are difficult to install.

b)the bulb protrudes too far below the light panel.

21

DUCTED INSTALLATION ONLY:

 

Re-install aluminum filters removed in Step 5.

NON-DUCTED INSTALLATION ONLY:

Install aluminum filters and non-ducted filters - purchased and assembled in Step 11.

WARRANTY

One Year Limited Warranty

Broan-NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one

(1) year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

During this one year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, TUBES, HALOGEN AND INCANDESCENT BULBS, FUSES, FILTERS, DUCTS, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR DUCTING. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan-NuTone), faulty installation or installation contrary to recommended installation instructions.

The duration of any implied warranty is limited to the one year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.

BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties.

To qualify for warranty service, you must (a) notify Broan-NuTone at the address or telephone number below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date.

Broan-NuTone LLC, 926 W. State Street, Hartford, Wisconsin 53027 www.broan.com 800-558-1711

Broan-NuTone Canada, Inc., 1140 Tristar Drive, Mississauga, Ontario Canada L5T 1H9 www.broan.ca 877-896-1119 Rev. 08/2007

MODELS QP230BC • QP230BL • QP230SS • QP230WW

QP236BC • QP236BL • QP236SS • QP236WW

QP242BC • QP242BL • QP242SS • QP242WW

Page 7

SERVICE PARTS

 

 

15

12

1

14

 

 

11

 

16

10

 

3

 

2

 

 

9

 

 

 

 

17

 

 

 

4

5

 

 

 

 

 

13

 

 

 

8

 

 

 

6

 

 

 

7

 

KEY NO.

PART NO.

DESCRIPTION

 

1

97017727

7” Round Duct Plate (includes mounting hardware)

 

2

97018245

User Interface Assembly White (includes interface, nameplate, mounting hardware)

 

 

97018246

User Interface Assembly Black (includes interface, nameplate, mounting hardware)

 

 

97018247

User Interface Assembly Bisque (includes interface, nameplate, mounting hardware)

 

3

99528248

Nameplate, White

 

 

99528249

Nameplate, Black

 

 

99528250

Nameplate, Bisque

 

4

97018251

Capacitor Kit (includes wire nuts, mounting screw)

 

5

97018225

Light Panel RH White (includes mounting hardware)

 

 

97018226

Light Panel RH Black (includes mounting hardware)

 

 

97018227

Light Panel RH Stainless (includes mounting hardware)

 

 

97018228

Light Panel RH Bisque (includes mounting hardware)

 

6

97018202

Filter Kit for 30”” (2 per bag)

 

 

97018203

Filter Kit for 36” (2 per bag)

 

 

97018204

Filter Kit for 42” (3 per bag)

 

7

97018220

Blower Wheel (includes mounting nut)

 

8

97018222

Motor Kit (includes motor, isolators, mounting hardware)

 

9

97017728

Damper / Duct Connector (includes mounting hardware)

 

10

97018229

Light Panel LH White (includes mounting hardware)

 

 

97018230

Light Panel LH Black (includes mounting hardware)

 

 

97018231

Light Panel LH Stainless (includes mounting hardware)

Order replacement parts by

 

97018232

Light Panel LH Bisque (includes mounting hardware)

PART NO. - not by KEY NO.

11

97017731

Lamp Socket (includes lamp socket, wire nuts, mounting screws)

 

12

97018233

Lamp Socket Bracket

 

13

97018236

Bottom Pan 30” (includes mounting hardware)

 

 

97018237

Bottom Pan 36” (includes mounting hardware)

 

 

97018238

Bottom Pan 42” (includes mounting hardware)

 

14

97018242

Non-duct Plenum (includes gasket & mounting hardware)

 

15

97018243

Non-duct Diverter (includes mounting hardware)

 

16

97018244

Non-duct Plate (includes mounting hardware)

 

17

97018254

Circuit Board

 

Not Shown

97018224

Parts Bag

 

Not Shown

99010353

Non-Duct Filter Kit for 30”” (2 charcoal filters and 8 filter clips)

 

 

99010354

Non-Duct Filter Kit for 36” (2 charcoal filters and 8 filter clips)

 

 

99010360

Non-Duct Filter Kit for 42” (3 charcoal filters and 12 filter clips)

 

Not Shown

99526707

Suction Cup Tool

 

Not Shown

97018252

Heat Sensor

 

Not Shown

97018253

Fuse

 

Not Shown

97018255

Ribbon Cable

 

Not Shown

V05921

50W Halogen GU10 Bulb

99527290E

 

 

 