Broan BPDP130SS ADA HIGH VOLTAGE WIRING INSTRUCTIONS

Broan BPDP130SS ADA HIGH VOLTAGE WIRING INSTRUCTIONS

ADA HIGH VOLTAGE WIRING INSTRUCTIONS FOR DOUBLE BLOWER RANGE HOODS WITH

ROCKER SWITCH CONTROL

! WARNING

For residential (domestic) installation only. Before proceeding, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards. Also, it is recommended to wear safety glasses and gloves.

ACCESS TO RANGE HOOD CONTROL PANEL CONNECTIONS

Remove both filters from the hood and set them aside.

Remove both side fillers by removing the 3 screws holding each one of them. Slide each one towards the center of the hood and tilt it up to remove it completely. Set the fillers and screws aside.

Locate the small plates on both left and right inner side ot the hood (shaded part in illustration below). Use thin sheet metal snips to split these plates.

CAUTION

Be careful not to kink the range hood side panels while splitting the plates.

NOTES: 1. The plates are for shipping purpose only, there is no need to reinstall them.

2.Blower not shown on illustration to ease understanding.

d

c

Using a 11/32” nutdriver or socket, remove both lock nuts retaining the flange of each blower cover plate (shaded parts on illustration at right) to the inner back of hood (see insets). Remove all cover plate retaining screws (10 screws), then set both blower covers along with their screws and nut aside.

5

 

4

10

 

3

 

6

 

 

9

 

2

 

 

8

7

1

LOCK NUTS

HR0213

Remove and set aside the 4 front screws retaining the inner front plate to the hood.

Screw locations

HD1103

Fold back the inner front plate to access to the hood control connections. Carefully cut-off the tie wrap retaining wires together.

TIE WRAP

BACK OF HOOD

HO0280

HD1104

1

99045893B

WIRING PROCEDURES

CAUTION

Use standard switches that are rated 120 VAC, 15 A. Only use wires suitable for at least 90oC (194oF). Ensure the wires are reliably routed away from the halogen lights (if present).

To suit your needs, there are 2 ways to wire a 2-rocker switch control to these range hoods: 120 VAC power cable entering the range hood or 120 VAC power cable entering the switch box.

120 VAC POWER CABLE ENTERING THE HOOD

 

2-ROCKER

 

 

SWITCH

 

Install a 2-rocker switch at a convenient place for the

RED

 

(motor)

GROUND

user. Use a 14/3 cable to wire it to the range hood

 

WHITE

 

(see diagram at right).

BLACK

 

NOTE: The code requires both ends of the WHITE

 

(lights)

 

wire insulation to be colored; use a permanent

 

 

marker.

 

 

Motor switch

Light switch

NOTE: Allow enough length of 14/3 cable to perform the RED wire

14/3 CABLE

connection in the hood nose.

TO HOOD

 

Insert the 14/3 cable along with the 14/2 house wiring cable in the

3

5

 

 

hood through an UL approved wire clamp, suitable for 2 cables.

 

TO CONTROL PANEL

Add a GROUND wire and connect one of its end to the GREEN

 

 

 

ground screw. Use an appropriate wire nut to connect the other

 

2

end of the added GROUND wire with the ground wire coming

 

from the 14/3 cable and the ground wire coming from 14/2 house

4

 

wiring cable.

MOTOR

Connect BLACK wire from house wiring to WHITE wire from

 

GROUND

 

WIRE

14/3 cable using an appropriate wire nut.

Connect BLACK wire from 14/3 cable to BLACK wire from range

 

 

BLACK

 

 

WHITE

hood wiring using an appropriate wire nut.

 

 

 

1

 

Connect WHITE wire from house wiring to WHITE wire range

 

RED

 

GROUND

hood wiring using an appropriate wire nut.

 

 

 

 

 

Run RED wire from 14/3 cable to top of right blower scroll. See

120 VAC

 

 

next page for RED wire connection.

14/3 CABLE

 

HOUSE WIRING

 

 

 

 

 

 

 

 

 

120 VAC POWER CABLE ENTERING THE SWITCH

 

 

 

 

 

 

2-ROCKER

 

 

 

SWITCH

 

 

 

 

 

RED

 

 

 

(motor)

GROUND

 

 

 

Install a 2-rocker switch at a convenient place for the

BLACK

 

14/3 CABLE

 

 

user. Feed the switch box with 120 VAC house wiring

 

 

TO HOOD

 

 

 

and use a 14/3 cable to wire it to the range hood (see

 

 

WHITE

diagram at right).

 

BLACK

 

 

 

(lights)

 

 

 

 

WHITE

 

 

 

120 VAC

 

 

 

LINE IN

Motor switch

Light switch

NOTE: Allow enough length of 14/3 cable to perform the RED wire

4

 

connection in the hood nose.

 

 

TO CONTROL PANEL

 

Insert the 14/3 cable in the hood through an UL approved wire

3

 

clamp. Connect ground wire to the GREEN ground screw.

2

 

 

 

 

MOTOR

 

Connect WHITE wire from 14/3 cable to WHITE wire from range

GROUND

 

WIRE

 

hood wiring using an appropriate wire nut.

 

 

 

Connect BLACK wire from 14/3 cable to BLACK wire from range

 

BLACK

 

WHITE

hood wiring using an appropriate wire nut.

 

1

RED

 

 

 

Run RED wire from 14/3 cable to top of right blower scroll. See next

 

GROUND

 

 

page for RED wire connection.

 

 

 

14/3 CABLE

 

2

RED WIRE CONNECTION

A Cut the BLACK wire that is connected to blower switch and light switch.

BCap off the BLACK wire connected to the light switch terminal. Connect the RED wire from 14/3 cable to the BLACK wire from the motor switch, using an appropriate wire nut.

ROCKER SWITCHES

 

 

 

ELONGATED ROCKER SWITCHES

 

BPDC1 SERIES

 

 

 

BPDP1 AND NPDP1 SERIES

 

MOTOR SWITCH

LIGHT SWITCH

A

MOTOR SWITCH

LIGHT SWITCH

TERMINALS

TERMINALS

TERMINALS

TERMINALS

 

 

A

BLACK WIRE

 

BLACK WIRE

 

 

 

 

MOTOR SWITCH

LIGHT SWITCH

 

 

TERMINALS

TERMINALS

MOTOR SWITCH

LIGHT SWITCH

 

B

TERMINALS

TERMINALS

B

RED WIRE

FROM 14/3 CABLE RED WIRE

FROM 14/3 CABLE

Once all the connections are done, finalize the installation by reversing steps to on first page.

RANGE HOOD OPERATION

Use the hood control to set or change the blower and light intensities desired; these settings will be applied when using the wall switches. For example, if the blower is set on high speed using the hood control, when the user presses on the motor rocker switch on the wall control, the blower will then turn on high speed. If the user wants the blower to turn on low speed, the blower speed must be changed using the hood control. It is not necessary to turn off the blower to change its speed.

The same procedure applies for the light intensities (when low and high intensities are available).

THIS PROCEDURE APPLIES TO BROAN BPDC1, BPDP1, AND NUTONE NPDP1

DOUBLE BLOWER RANGE HOOD SERIES.

3