Broan 942236-K1, 947230-Q1, 947236-Q1, 947224-Q1, 942224-P1 User Manual

...
0 (0)
Broan 942236-K1, 947230-Q1, 947236-Q1, 947224-Q1, 942224-P1 User Manual

PRESTIQUE

MEDICINE CABINET

MODEL NO.

SIZE

FINISH

 

942224-P1

24”

White

 

942230-K1

30”

White

 

942236-K1

36”

White

For help, call

947224-Q1

24”

Oak

947230-Q1

30”

Oak

us toll free!

947236-Q1

36”

Oak

 

 

 

1-800-637-1453

INSTRUCTIONS FOR WALL-MOUNT INSTALLATIONS

WARNING: Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.

Prepare cabinet.

1. Carefully remove all packing material.

Determine location.

1.The commonly accepted height of bath cabinets is 64" from the finished floor to the center of the mirror area. However, height may be adjusted to individual preference.

2.It is recommended that the cabinet be located such that the mounting screws may be screwed into wall studs to provide maximum strength.

3.Provide 120 VAC power cable through the wall material, directly behind the light box.

Mount cabinet.

1.Measure and mark four (4) clearance holes in cabinet back at wall stud locations. Use angle brackets to locate upper holes. (Fig. 1)

2.Drill ¼" dia. clearance holes through cabinet back.

3.Hold angle brackets in place over top set of holes. Mount brackets to underside of light housing with #6 x ½" screws.

4.Hold cabinet in place and make sure it is level. Screw cabinet to wall studs.

NOTE: Irregularities in wall surface may cause distortion of cabinet body when mounted. Place shims between cabinet and wall at appropriate corners.

OPTION (If wall studs are not available):

4.Hold cabinet in place and make sure it is level. Mark wall through all four

(4) clearance holes.

5.Set cabinet aside and drill holes in wall material for molly bolts or wall anchors (not provided).

6.Mount cabinet to wall material.

Connect electrical wiring.

WARNING: Before wiring this product, switch power off at service entrance and lock service panel to prevent power from being switched on accidentally.

1.Remove reflector from wrapper.

2.Remove protective plastic film from reflector and snap light cups onto sockets.

3.Make electrical connections between house wires and fixture wires on rear of reflector: black to black, white to white, and greenwire to a permanent ground. (FIG. 2)

4.Attach reflector to cabinet.

Mount shelves.

1.Choose the location for the shelves from the five (5) sets of holes located on the inside of the cabinet.

2.Insert two (2) shelf tabs into holes, at desired location on one side of the cabinet. Repeat on the other side, being sure to use holes at the same height, so the shelf will be level.

3.Set shelves on pins.

Attach mirror doors.

1.Remove wrapping from mirror door. Remove hinge brackets and pressure plates from parts bag.

FIG. 1

WIRING

SHELF

REFLECTOR

ACCESS

 

 

TABS

 

 

HOLE

 

ANGLE

 

 

 

 

 

BRACKET

 

 

 

 

 

LIGHT

 

SCREW

 

SOCKET

 

 

 

 

#8 x 1½”

SCREW

SCREW

 

#6 x 3/8”

 

 

CUP

#6 x ½”

 

 

 

 

CLEARANCE

 

 

 

HOLES

 

 

 

 

 

MIRROR

 

 

 

DOOR

 

SHELF

 

 

 

STRIKE

 

HINGE

 

PLATE

 

 

 

BRACKET

 

 

 

(Pressure plate

MAGNET

 

beneath

 

 

 

NYLON backside)

 

URETHANE DISC

 

WASHER

FIG. 2

All electrical connections must be made in accordance

 

with local code ordinances. If you are unfamiliar with

methods of installing electrical wiring, secure the services of a qualified electrician.

GREEN TO

GROUND

WIRE

WHITE TO WHITE BLACK TO BLACK

FIG. 3

HINGE FIG. 4

 

BRACKET

BACKSIDE OF

PRESSURE MIRROR DOOR

PLATE

FIG. 5

FIG. 6

2.Peel paper backing from two (2) pressure plates and affix plates to backside of mirror door at upper-left and lower-left corners. (FIG. 3)

3.Slide hinge bracket(s) over top of door(s) and lightly tighten screws against pressure plate(s). (FIG. 3)

4.Place a nylon washer on the pin of the remaining hinge bracket and insert hinge bracket(s) into hole(s) in bottom of frame.

5.Lift mirror door(s) and insert top hinge bracket(s) into hole(s) in top of frame. (FIG. 4) Slide bottom of mirror door(s) into lower hinge bracket(s) (FIG. 5) and lightly tighten screws against pressure plate(s). (FIG 6)

6.Remove the 1" diameter strike plate(s) from the parts bag. Peel off the paper backing and affix plate(s) to rear of mirror door(s) at the lower corner(s) opposite the magnetic catch(es).

7.Clear urethane discs are furnished to prevent finger marks on mirror face. To mount: Remove paper backing and affix to mirror face ½” from bottom and outside edge.

A99042675C

INSTRUCTIONS FOR

BUILT-IN INSTALLATIONS

WARNING: Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.

Prepare cabinet.

1. Carefully remove all packing material.

Determine location.

1.Mark the wall to show wall opening size. (See dimension chart) Note: Commonly accepted height of a medicine cabinet is 64" from the finished floor to center of mirror area. However, height may be adjusted to individual preference.

2.Provide 120 VAC power cable through wall, directly behind light box. (Fig. 7)

Mount cabinet.

1.Cut out wall opening, being careful not to damage the surrounding wall surface. (Fig. 7) The rough wall opening must be free of all obstructions. Additional framing must be provided. (Fig. 8)

2.Drill (2) 3/16” diameter clearance holes through the left side of the cabinet. Locate holes 1½” in from inside top and bottom edges of cabinet and 1½” from inside back of cabinet. Repeat on other side.

WARNING: Before wiring this product, switch power off at service entrance and lock service panel to prevent power from being switched on accidentally.

3.Remove face plate from cabinet.

4.Pull 6" of power cable through access hole in light fixture box and secure cable to box with proper connector.

5.Insert cabinet into wall opening and secure to wall studs through four clearance holes with mounting screws.

Connect electrical wiring.

1.Strip ½” of insulation from wires. Make electrical connections: black to black, white to white, and green or bare wires to a permanent ground.

2.Re-attach face plate to cabinet.

Mount shelves and attach mirror doors.

1. Follow instructions on other side of this sheet.

FIG. 7

FIG. 8

DIMENSIONS

W x H x D

 

 

Size

Wall Opening Size

 

 

 

 

24”

225/8

x 271/4

x 3½

30"

285/8

x 271/4

x 3½

36"

345/8

x 271/4

x 3½

BROAN ONE YEAR LIMITED WARRANTY

Broan warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED

TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

During this one-year period, Broan will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.

THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan), faulty installation or installation contrary to recommended installation instructions.

The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.

BROAN’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY

UNDER THIS WARRANTY. BROAN SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties.

To qualify for warranty service, you must (a) notify Broan at the address stated below or telephone: 1-800-637-1453, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date.

BROAN MFG. CO., INC., 926 West State Street, Hartford, WI 53027