Valve Specifications
Maximum Operating Pressure
125 PSI (860 kPA)
Maximum Inlet Temperature
200° F (93° C)
Temperature Range Set Point
95° F (35° C) to 115° F (46° C) 105° F (41° C)
Std.
Flow Capacities – GPM (L/Min)
Pressure Drop – PSI (Bar)
10
15
(1.5)
4.5
(20.5)
20
(2.0)
5.0
(24.5)
(1.0)
3.5
(16.0)
30
(2.5)
6.5
(27.5)
Model
S59-2007
Min
Flow
0.5
(2.0)
5
(.5)
2.0
(10.0)
45
(3.0)
8.0
(30.0)
60
(4.0)
9.5
(35.5)
Dimensions
S59-2007
Thermostatic Mixing Valve
(mm)
Code Compliance and Certifications
ASSE 1017 & CSA certified.
Optional Selections
Finish
¨ C
Thermometer
¨ T
Cabinets
¨ SS
¨ RS
¨ SE
¨ RE
¨ W
Standard product selections contained within this document are third party
CERTIFIED to NSF/ANSI 372 meeting the Lead-Free content requirement. Any
product configured with custom options will be COMPLIANT with NSF/ANSI
372 meeting the Lead-Free content requirement.
Chrome Plated
Dial Thermometer
Surface Mount Stainless Steel
Recessed Stainless Steel
Surface Mount White Enamel
Recessed White Enamel
Plexi-glass Window in Door
Engineer's Approval
Page 1 of 1 8/19/2014
This information is subject to change without notice.
Bradley_TMV_PointOfUse_S59-2007
Front
View
Side
View
1/2" NPT
4-1/2"
(113)
1/2" NPT
3-7/8"
(98)
1/2" NPT
3-1/8"
(78)
Certified to
1-5/8"
(40)
© 2015 Bradley
bradleycorp.com
3"
(76)
5" (127)
6-1/8" (157)
1-1/2"
(38)
3"
(75)
1-3/4"
(43)
P.O. Box 309, Menomonee Falls, WI 53052-0309