Bosch VMD01 M60 NTSC, VMD01 M50 PAL User Manual

0 (0)

VMD01 – M50 PAL

VMD01 – M60 NTSC

Security Systems

Operating instrutions

EN Video Motion Detector

Utilisation

FR Détecteur de mouvement vidéo

Bedienungsanleitung

DE Videobewegungssensor

Instucciones de servicio

SP Sensor de movimiento de vídeo

Handleiding

NL Videobewegingssensor

Instruzioni per l’uso

IT Sensore di movimento video

Manual de operação

PO Vídeo–sensor de movimentos

610–4.998.137.762 Ausgabe: 1

Stand: Februar 03

FCC

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technican for help.

Recognized Component Mark for Canada and the United States

If the unit is used as a stand alone, it must be supplied via a power supply which fulfils the requirement on “SELV” and on a Limited Power Source.

If the unit is mounted into a 19” rack a suitable fire enclosure must be provided in the end–unit.

EU Declaration of Conformity

Bosch declares, this product: is conform to the following standards:

Supplementary Information: “The product complies with the requirements of the low Voltage Directive 73/23EEC and the EMC Directive 89/336/EEC.”

This product is carrying the CE–Mark in accordance with the related European Directives. Responsible for CE–Marking is

Bosch Sicherheitssysteme GmbH Security Systems Division Ludwig–Boelkow–Allee

85521 Ottobrunn Germany

– 2 –

A1 February 03/Trb

TABLE OF CONTENTS

English

 

 

Chapter

Page

1

Introduction

38

2

Mounting

39

3

Functions

42

4

System structure

44

5

Programming

45

6

Operating instructions

50

7

Technical data

52

8

Notes

53

Français

20

German

37

Español

54

Italiano

71

Dutch

88

Portuguese

105

Note:

Additional information about the product, installation, and operation can be found at: http://www.boschsecuritysystems.com

– 3 –

A1 February 03/Trb

1 Introduction

English

This is a high-quality single-channel video movement sensor for direct integration in an analog CCTV system.

Video signals are evaluated through image analysis and interpretation. Alarm, pre-alarm and post-alarm images are stored.

Additional information on project planning and the software tool can be obtained in electronic form through a dealer or installer.

Statutes/Norms/Guidelines met by the unit

EMV law on the basis of

DIN EN 50081–1 (radiated noise) DIN EN 50130–4 (noise immunity)

DIN EN 60950 (electrical safety)

Environment to IEC 68–2–2/Degree I, 68–2–1, 68–2–30

The product carries the CE symbol. Registration: FCC

Registration: Recognition Component Mark for Canada and the United States (File number: E221534)

Basic shipment contents

Basic device (VMD01–M50/M60)

Operating instructions

15-pin Sub–D plug

Flat box with rubber feet and brackets

Accessories

Power supply VMD–PS

Wall holder VMD–WM

Mouse VMD–SM

19” frame incl. mounting VMD–RA90

19”frame incl. mounting brackets without power supply/cable set/ Distributor LP, with blind plate VMD–RA00

19” blind plate VMD–RADC

Camera, monitor, recorder, mouse (for programming) and cabling are not part of the shipment contents.

Only for programming

Alarm contact

– 4 –

A1 February 03/Trb

2 Mounting

English

2.1General mounting notes

Use only cable specified by the manufacturer. Protection against malfunction cannot otherwise be guaranteed.

To guarantee operational safety, only those power supplies specified by the manufacturer may be used. (individual devices: power supply VMD–PS, for 19” installation, the power supply is integrated in the VMD–RA frame).

For questions regarding setup, environmental conditions and safety of individual components, manufacturer documentation must be consulted.

For installation, this instruction manual and the specific connection instructions are to be followed.

This description does not contain information about installation and setup of the camera, monitor and recorder.

2.1.1Mounting Variants

 

Unit feet

 

 

1. Press in

 

 

2. Press in

 

 

 

Locking

Feet

3. Press down with blunt object

spring

Housing vertical

Four feet must be fitted to the unit base plate. The connecting cable must have sufficient strain relief.

Housing can be stacked upright. Warning!

Maximum of four units can be stacked upright on top of each other.

If housings are stacked on top of each other, the feet on the underside of the housing must be fitted. There are no locking springs for the bottom unit. For all other units to be stacked, the locking springs must be pushed into the feet and pressed into the locating slits on the bottom unit. Ensure sufficient strain relief.

– 5 –

A1 February 03/Trb

Mounting continued

English

 

 

2.1.2Wall holder for mounting on walls and ceilings (accessory VMD–WM)

TOP

 

TOP

Holes for

Mounting holes

Holes for

strain relief

for housing

strain relief

The wall holder can be used as a drilling template. Before mounting on a wall, screw the wall holder (using fitting holes for housing) to the unit. For strain relief using cable ties, use the holes in the mounting plate.

Warning!

Only one unit may be mounted on a wall or ceiling.

2.1.3Connections / Front

 

3

 

4

 

 

 

 

 

1 2

 

1

L1 green

2

L2 red

3

Key/Rotary Switch

4

Mouse connection, RS232 serial interface

2.1.4Connections / Rear

 

1

2

1

3

4

 

 

11

6

 

 

1

5V DC

2

I/O Contacts

 

3

Video OUT

4

Video IN

 

– 6 –

A1 February 03/Trb

Bosch VMD01 M60 NTSC, VMD01 M50 PAL User Manual

Mounting continued

English

 

 

2.219” mounting frame and wiring (Accessory VMD–RA90)

Front

Maximum expansion

mounting

8 units

bracket

Rear

Power supply

Top view (distributor LP)

Fuse = 2A

+5V

 

 

100–240V

Power supply

Direction of swivel

100–240V

L IEG 5V– +5V

For rack mounting, insert the mounting angle brackets (packaged extra) into the slides, screw down and feed the cabling through.

Warning

Grounding must be professionally carried out according to IEN 60950.

2.2.119” mounting frame without wiring (accessory VMD–RA00)

The frame is delivered without power supply/cable set/distributor LP, with blind plate.

– 7 –

A1 February 03/Trb

3 Functions

English

3.1Overlaid lines for color and B/W signals

Live and archived images

Color

 

Black/White

 

Alarm object:

Red

Striped line with high contrast

 

 

 

 

 

 

Pre-alarm object:

Yellow

Striped line with low contrast

 

 

 

 

 

 

Tracking line:

Green

Striped line

 

 

 

 

 

 

 

 

 

Configuration

Color

Black/White

Area of sensitivity:

Green

Striped line

 

 

 

Perspective:

Green: Foreground

Striped lines;

 

Blue: Background

Foreground square: Larger dotted line

 

 

 

Background square: Smaller dotted line

Directionality:

Green: Direction

Striped lines;

 

Blue: Tolerance

Directional arrow with smaller dotted lines

 

 

 

Tolerance lines with larger dotted lines

 

 

 

 

 

3.2

Rotary switch

 

 

 

 

 

 

 

Operation

Function

 

 

Briefly press

Alarm image memory on

 

 

 

 

 

 

Briefly press again

Alarm image memory off

 

 

 

 

 

 

Long press (> 2 sec.)

Acknowledge alarm

 

 

 

 

 

 

Rotate right

Forwards in alarm archive (+)

 

 

 

 

 

 

Rotate left

Backwards in alarm archive (–)

3.3Light emitting diodes

LED

Status

Function

L1 green

off

No supply of power to unit

 

 

 

 

on

Unit operating normally

 

Blinking

Unit malfunction as combined message

 

Unit defective and/or video channel malfunction

 

 

L2 red

off

No alarm, not armed

(when L1 on)

 

 

 

 

 

 

on

No alarm, armed

 

 

 

 

Blinking

Object detected/Alarm on

 

 

 

L2 red

off

No malfunction on video signal,

(when L1 blinking)

unit malfunctioning

 

 

on

No video signal, no general unit malfunction

 

 

 

 

 

Video signal interference:

 

Blinking

1. Signal/Noise ratio too low

 

2. Camera blinded

 

 

 

 

3. Scene lighting level too low

 

 

 

– 8 –

A1 February 03/Trb

Functions continued

English

 

 

3.4Contact assignment

PIN

Function

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical specification

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Input contact I

 

 

 

 

 

 

 

 

 

 

 

 

 

Internal pull-up

 

 

 

Open: sensor armed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

At ground (Pin 5): Sensor disarmed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Input contact II

 

 

 

 

 

 

 

 

 

 

 

 

 

Internal pull-up

 

 

 

Open: Parameter set I active

 

 

 

 

 

 

 

 

 

 

At ground (Pin 5):

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter set II active

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

Output contact I

 

 

 

 

 

 

 

 

 

 

 

 

 

Open collector,

 

 

 

Internally switched to ground: Object detected

max. 100mA, 12V

 

 

 

Open: No object detected

 

Externally switchable

 

 

(constant signal, impulse or periodic impulse)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Output contact II

 

 

 

 

 

 

 

 

 

 

 

 

 

Open collector,

 

 

 

Internally switched to ground:

 

max. 100mA, 12V

 

 

 

Video signal malfunction

 

Externally switchable

 

 

Open: Video signal OK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

Ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

Relay I

 

 

 

 

 

 

 

 

 

 

 

 

 

Max. 30V, max. 1A

 

 

 

6/7 closed: Malfunction

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

Relay I (Middle contact)

 

 

 

 

 

 

 

 

 

 

 

 

 

Max. 30V, max. 1A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

Relay I

 

 

 

 

 

 

 

 

 

 

 

 

 

Max. 30V, max. 1A

 

 

 

8/7 closed: No malfunction

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

Relay II

 

 

 

 

 

 

 

 

 

 

 

 

 

Max. 30V, max. 1A

 

 

 

9/10 closed: No alarm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

Relay II (Middle contact)

 

Max. 30V, max. 1A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

Relay II

 

 

 

 

 

 

 

 

 

 

 

 

 

Max. 30V, max. 1A

 

 

 

11/10 closed: Alarm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

Remote control Rotary switch:

 

Internal pull-up

 

 

 

Backwards in alarm archive (–) when turned left

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

Remote control Rotary switch:

 

Internal pull-up

 

 

 

– Switchover: Live image/alarm archive

 

 

 

 

 

 

 

 

 

 

– active >2 secs. = alarm acknowledgement

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14

Remote control Rotary switch:

 

Internal pull-up

 

 

 

Forwards in alarm archive (–) when turned right

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

Remote control Rotary switch: Ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input contacts

 

 

 

 

 

+5V

Output contacts

3/4

 

 

 

 

 

 

 

Remote control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12/13/14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5/15

 

5/15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

– 9 –

A1 February 03/Trb

4 System structure

English

4.1Menu

Programming

Parameter set 1

Alarm set 1

Operating mode set 1

Alarm contact set 1

Sensor parameter set 1

Area of sensitivity set 1

Object size/Perspective set 1

Direction of movement set 1

Parameter set 2 Alarm set 2

Operating mode set 2

Alarm contact set 2

Sensor parameter set 2

Area of sensitivity set 2

Object size/Perspective set 2

Direction of movement set 2 Copy parameter set

Language

Change code number

System information Exit

– 10 –

A1 February 03/Trb

5 Programming

English

5.1Startup

The unit should be started up at room temperature.

Before starting up, ensure that all components are correctly connected. Follow mounting instructions!

Menu screen

1

Work area/Live image

 

3

 

 

2

Help text

1

 

3

Company logo

4

 

4

User navigation

 

 

 

 

2

 

5.1.1Operation

When setting up, please use the menu tree and the help text in the lower monitor window. The following symbols are used for navigation:

= Cancel (dismiss entry, return to higher level)

= Confirm (accept entry, return to higher menu level)

= Correct (delete current entry)

= One level back

= Exit

Unless otherwise stated, the left mouse button is used for drawing and pasting and the right mouse button for deleting.

5.1.2Code number (default 00000) / Change code number

After switch-on or after selecting “Exit” from the programming screen, there is a delay of around 5 seconds before the mouse can be moved to enter the code mask.

Change code number : Enter the new code number twice.

– 11 –

A1 February 03/Trb

Programming, continued

English

 

 

5.2Programming

Starting programming

Parameter set 1 or = Parameter set 2

5.2.1 Alarm set 1 or 2

Operating type

Automatic acknowledgement, live image on alarm

Manual acknowledgement, live image on alarm

Manual acknowledgement, alarm image on alarm

See also chapter 6

Alarm contacts (contact output I see 3.4)

Continuous signal during object detection

Impulse on new object detection

Periodic signal during object detection

Signaling of alarms

 

LED red

Relay II

Output

 

Blinking

contacts

 

 

 

 

 

 

Automatic

As long

As long

As long as

as

as

object

acknowl-

object

object

detected

edgement

detected

detected

or impulse

 

 

 

 

 

Manual

As long

As long

As long as

as

as

object

acknowl-

Alarm

Alarm

detected

edgement

on

on

or impulse

 

 

 

 

 

– 12 –

A1 February 03/Trb

Programming, continued

English

 

 

5.2.2 Sensor parameter set 1 or 2

See chapter 3.1 (overlaid lines)

Area of sensitivity set 1 or 2

The live image is shown with the sensitive, undarkened area. With the right mouse button pressed, square non-sensitive areas can be pulled up. After releasing the mouse button these are darkened and shown. Multiple non-sensitive areas of different sizes can be distributed on the image. With the left mouse button, non-sensitive areas can be deleted or modified by drawing over them; sensitive areas can be added with the right mouse button.

Drawing in object size/perspective set 1 or 2

The live image is shown with a small rectangle. Its size is the factory-set default, not the minimum size. No perspective is set. Everything larger than the plotted rectangle is detected. The frame can be changed in size, moved about on the image, or another frame pulled up using the left mouse button. The larger frames show the minimum object size to be detected in the foreground. The smaller frames show the minimum object size in the background. The position of the frames relative to each other shows the perspective set. Note that the position of the perspective always only runs horizontally or vertically, even when the rectangles on the image are arranged diagonally. If one thinks of both rectangles as the endpoint of an “L” lying parallel to the image edges, the longer side indicates the position. If the relative sizes of the frames are changed, the colors or types of lines also change. The rectangles can be deleted by dragging a frame with the right mouse button. If both rectangles are deleted, the small rectangle reappears.

– 13 –

A1 February 03/Trb

Programming, continued

English

 

 

Example of perspective positioning

Longer side (horizontal perspective)

Horizontal

Vertical

 

 

 

 

 

 

 

 

Longer side

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(vertical perspective)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Direction of movement set 1 or 2

The live image is shown with a small rectangle in the middle of the image and all movements lead to an alarm being triggered. No permitted direction of movement is plotted.

Plotting the permitted direction of movement:

The permitted direction of movement is plotted by pressing the left mouse button in the live image. This is marked by an arrow with two tolerance lines. These two lines represent the tolerance in the permitted direction of movement. If the cursor is moved to the arrow tips or the tolerance lines, the cursor symbol changes. The arrow and tolerance lines can be rotated and the tolerance lines opened up or made narrower with the left mouse button.

Pressing the mouse button in the opposite arrow direction results in the appearance of a second arrow with tolerance lines being plotted on the image. The arrows and tolerance lines can be deleted by dragging a frame over them with the right mouse button.

5.2.3Copy parameter sets

Parameter set 2 becomes a copy of set 1, or 1 of set 2.

– 14 –

A1 February 03/Trb

Programming, continued

English

 

 

5.2.4Saving parameter sets

For this, use the service program VMD01Service.exe on a PC. Connect the PC’s serial interface to the unit’s RS232 interface via a null-modem cable. To save, call the program with the parameter ‘–pd’. The parameter data is saved in a file in the same directory as the software. The file name may look as follows “VMD01ParaXXXXX”. XXXXX here represents the unit ID. The parameter data can be played back in with the tool. The parameter ‘–pu’ and the parameter file are entered for this purpose. This allows copying of parameter sets from one unit to another.

– 15 –

A1 February 03/Trb

6

Operating instructions

English

 

 

 

6.1Acknowledge / Alarm images

All parts of the system are switched on, operational and programmed. The live image can be seen on the monitor. The green and red LEDs are lit. An operating mode has been programmed.

Operating mode

Automatic acknowledgement, live image on alarm

If an alarm has occurred, the live image is shown with overlaid masks. The alarm is automatically acknowledged. If a subsequent alarm is detected, the previous alarm images are deleted. The alarm memory always contains the newest alarm.

Manual acknowledgement, live image on alarm

If an alarm has occurred, the live image is shown with overlaid masks. The system remains armed. A subsequent alarm does not store new alarm images, but is signaled at the output contact. The alarm image memory always contains the oldest unacknowledged alarm. The live image appears after manual acknowledgement.

Manual acknowledgement, alarm image on alarm

If an alarm has occurred, the alarm image (No. 0) is shown with overlaid masks. The masks will disappear after 5 seconds. The system is still armed. A subsequent alarm does not store new alarm images, but is signaled at the output contact. The alarm image memory always contains the oldest unacknowledged alarm. The live image appears after manual acknowledgement.

Alarm acknowledgement

If an alarm occurs, the red LED blinks.

The alarm is acknowledged by pressing (> two seconds) the key/rotary switch. The red LED then switches from blinking to steadily lit (not for AQL).

– 16 –

A1 February 03/Trb

Operating instructions, continued

English

 

 

Access to alarm image memory:

Alarm images can be viewed before or after acknowledgement. To switch from live images to alarm images, briefly press the key/rotary switch.

No alarm images present = .

If alarm images are present, a display “0“ appears in the monitor picture, i.e. the alarm occurred at this point in time.

Rotate the key/rotary switch to the:

left, for pre-alarm images right, for post-alarm images +”. The object causing the alarm is outlined in red in the alarm image and in the post-alarm image. The first detection of the object is outlined in yellow. Movement of the object is outlined with a green line between the yellow and red lines. See also chapter 3.1 (Overlaid lines for color and B/W signals). If an image is displayed for longer than 5 seconds, the lines will disappear. Upon switching further to pre or post-alarm images, these will first be displayed with masks. The alarm mode is exited by briefly pressing again. There is a switch to the live image if no operation in the alarm memory is carried out within 60 seconds.

– 17 –

A1 February 03/Trb

7 Technical data

English

7.11 channel variant

Main memory

 

 

 

 

 

 

32MB RAM

Video input

 

 

 

 

 

 

1 x BNC, PAL (CCIR) / NTSC (EIA),

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75Ω internal, 1Vss (0.5–2.0Vss)

Video output

 

 

 

 

 

 

1 x BNC, PAL (CCIR) / NTSC (EIA), 1Vss

Input contacts

 

 

 

 

 

 

Internal pull-up

Contact outputs

Open collector 100mA/12V ext. switchable

Relay outputs

 

 

 

 

 

 

max. 30V, max. 1A

Connections (Rear)

see Mounting

Connections (Front)

see Mounting

Serial interface

RS232 (Saving data/Mouse connector)

Weight

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

approx. 0.5 kg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(without power supply and mouse)

Dimensions (H x W x D)

approx. 110mm x 48mm x 207mm

Storage temperature

233 K ... 343 K (–40° C ... +70°C)

Relative humidity in storage

8% ... 80% (relative humidity)

Operational temperature

273 K ... 318 K (+0° C ... +45°C)

Relative humidity in operation

15% ... 80% (relative humidity)

Current consumption

5W/1.2A

 

Pin assignments: Power supply:

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

PIN1 = +5V

PIN4 = GND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PIN2 = +5V

PIN5 = nc

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PIN3 = nc

PIN6 = GND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

Power supply in 19” rack

 

 

D Input voltage

100–240 VAC / 50–60Hz

D Output voltage

5 VDC / 100VA

7.2Wall holder

Dimensions (H x W x D)

approx. 205mm x 164mm x 10mm

Weight

approx. 0.4 kg

For the model PAL or NTSC, please see the type label.

Subject to technical changes

– 18 –

A1 February 03/Trb

8 Notes

English

8.1General

If errors or malfunctions occur, the plug-in connectors should be checked first. A malfunction can sometimes be cured by briefly unplugging and re-plugging the power cord on the unit.

The unit may not be opened. Guarantee claims are rendered invalid if the seal is broken.

Description of the LEDs: See the Functions chapter.

Superimposed malfunction indications for video signal malfunctions

= Camera blinded

= Scene lighting level too low

= Signal/noise ratio too low

= No video signal present

Reset to default setting

Unplug contact plugs and power supply from unit. Keep rotary switch pressed, plug power supply back in. The green LED lights. Keep the rotary switch pressed until the red LED lights (or blinks if an object is detected simultaneously). Immediately rotate the still-pressed rotary switch, wait until the red LED goes out and release the rotary switch. When the live image appears, the reset procedure is finished.

Notes

The video movement sensor is delivered with software already installed. For questions about the product, please consult your dealer.

Cleaning

Protect the unit from dust and moisture. Do not use aggressive cleaning agents.

All unusable parts of the video systems must be professionally disposed of.

– 19 –

A1 February 03/Trb

TABLE DES MATIERES

Français

 

 

Chapitre

Page

1

Introduction

38

2

Montage

39

3

Fonctions

42

4

Structure du système

44

5

Paramétrage

45

6

Utilisation

50

7

Données techniques

52

8

Conseils

53

Remarque :

Pour plus d’informations sur ce produit, son installation et son utilisation, visitez le site http://www.boschsecuritysystems.com

– 20 –

A1 February 03/Trb

1

Introduction

Français

 

 

 

Détecteur de mouvement vidéo monocanal de qualité supérieure pour intégration directe dans un système de télévision en circuit fermé analogique. Exploitation des signaux vidéo par analyse d’images et interprétation. Enregistrement des images de pré-alarme, d’alarme et de post-alarme.

Un complément d’informations sur la conception du projet et l’outil logiciel est disponible sous forme électronique auprès de votre revendeur ou de votre installateur.

Lois / normes / directives auxquelles l’appareil est conforme

Loi sur la compatibilité électromagnétique (CEM) sur la base des normes suivantes

DIN EN 50081–1 (émissions) DIN EN 50130–4 (immunité)

DIN EN 60950 (sécurité électrique)

Environnement suivant IEC 68–2–2/niveau d’essai d’immunité I, 68–2–1, 68–2–30

Le produit porte la marque CE. Homologation : FCC

Homologation : Recognition Component Mark for Canada and the United States (Filenumber : E221534)

Contenu du module de base

Accessoires

Appareil de base (VMD01–M50/M60)

Bloc d’alimentation enfichable

 

 

 

VMD–PS

Mode d’emploi

Support mural VMD–WM

– Connecteur Sub–D 15 pôles

Souris VMD–SM

– Sachet avec pieds en caoutchouc et

– Châssis 19” avec support

 

pinces

 

VMD–RA90

 

 

– Châssis 19” avec support

 

 

 

sans unité d’alimentation /

 

 

 

jeu de câbles /

 

 

 

carte imprimée répartiteur,

 

 

 

avec plaque obturatrice

 

 

 

VMD–RA00

 

 

Plaque obturatrice 19”

 

 

 

VMD–RADC

Caméra, moniteur, enregistreur, souris (pour le paramétrage) et câbles non fournis.

Uniquement pour le paramétrage

Contact d’alarme

– 21 –

A1 February 03/Trb

2

Montage

Français

 

 

 

2.1Instructions de montage générales

Utilisez exclusivement le câble recommandé par le fabricant, faute de quoi la protection contre les interférences ne sera pas assurée.

Pour garantir la sécurité de fonctionnement, seules les unités d’alimentation recommandées par le fabricant peuvent être utilisées. (Appareils individuels : bloc d’alimentation VMD–PS, lors du montage 19”, le bloc d’alimentation est intégré dans le châssis VMD–RA).

Pour les questions relatives à l’installation, les conditions ambiantes, la sécurité des différents composants matériels, consultez impérativement la documentation du fabricant.

Lors de l’installation, il convient de respecter ce mode d’emploi et les conditions de connexion en vigueur.

Ce manuel ne décrit pas l’installation et la disposition de la caméra, du moniteur et de l’enregistreur.

2.1.1Variantes de montage

Pied de l’appareil

1. Enfoncer

2. Enfoncer

 

3. Enfoncer avec un objet épointé

Ressort

Pieds

d’arrêt

Boîtier vertical

Quatre pieds doivent être montés sous le boîtier. Il convient de veiller à une décharge de traction suffisante du câble de connexion.

Boîtier horizontal, empilable Attention !

Un maximum de quatre appareils peuvent être empilés horizontalement.

En cas d’empilage horizontal des boîtiers, les pieds doivent être montés sous les boîtiers. Le dernier appareil de la pile ne comporte pas de ressorts d’arrêt. Pour tous les autres appareils à empiler, les ressorts d’arrêt doivent être insérés dans les pieds et enfoncés dans les fentes du boîtier inférieur. Prévoyez une décharge de traction suffisante.

– 22 –

A1 February 03/Trb

Suite Montage

Français

 

 

2.1.2Support pour montage mural et au plafond (accessoire VMD–WM)

HAUT

HAUT

 

Trous pour

Trous de centrage

Trous pour

décharge de traction

du boîtier

décharge de traction

Vous pouvez utiliser le support mural comme gabarit de perçage. Avant le montage mural, vissez le support (trous de centrage du boîtier) sur l’appareil. Utilisez les trous de la plaque de montage pour la décharge de traction avec serre-câbles.

Attention !

Vous ne pouvez monter qu’un seul appareil au mur ou au plafond.

2.1.3Connexions / Face avant

 

3

4

 

 

 

 

 

1 2

 

 

1

L1 vert

2

L2 rouge

3

Poussoir / Commutateur rotatif

4

Port souris, port série RS232

2.1.4Connexions / Face arrière

 

1

2

1

3

4

 

 

11

6

 

 

1

5 V c.c.

 

 

2

Contacts E/S

3

Sortie vidéo

 

 

4

Entrée vidéo

– 23 –

A1 February 03/Trb

Suite Montage

Français

 

 

2.2Châssis de montage 19” et câblage (Accessoires VMD–RA90)

Face avant

Configuration

Equerre

maximale

de montage

8 appareils

 

Face arrière

Unité d’alimentation

Vue de dessus (carte imprimée répartiteur)

Si = 2A

+5V

 

Unité d’alimentation

 

 

100 – 240 V

 

 

 

 

 

Sens de pivotement

100 – 240 V

L NEG 5V– +5V

Pour le montage dans le tiroir, placez et insérez-y l’équerre de montage (jointe), vissez et procédez au câblage.

Attention !

La mise à la terre doit être effectuée conformément à IEN 60950.

2.2.1Châssis de montage 19” sans câblage (accessoire VMD–RA00)

Le châssis est fourni sans unité d’alimentation/jeu de câbles/carte imprimée répartiteur, avec plaque obturatrice.

– 24 –

A1 February 03/Trb

3

Fonctions

Français

 

 

 

3.1Lignes de brouillage pour les signaux couleur et N/B

Images en direct et d’archive

Couleur

Noir/blanc

Objet d’alarme :

Rouge

Ligne hachurée avec contraste élevé

 

 

 

Objet de pré-alarme :

Jaune

Ligne hachurée avec contraste faible

 

 

 

Ligne de tracking :

Vert

Ligne hachurée

 

 

 

Paramétrage

Couleur

Noir/blanc

Zone sensible :

Vert

Ligne hachurée

 

 

 

Perspective :

Vert : avant-plan

Lignes hachurées ;

 

Bleu : arrière-plan

Rectangle avant-plan : grands traits

 

 

Rectangle arrière-plan : traits plus petits

Directionnalité :

Vert : direction

Lignes hachurées ;

 

Bleu : tolérance

Flèche directionnelle avec petits traits

 

 

Lignes de tolérance avec grands traits

 

 

 

3.2Commutateur rotatif

Action

Fonction

 

Brève pression

Activation de la mémoire d’images d’alarme

 

 

 

 

Nouvelle brève pression

Désactivation de la mémoire d’images d’alarme

 

 

 

 

Longue pression (> 2 s)

Confirmation de l’alarme

 

 

 

 

Rotation vers la droite

Progression dans l’archive des alarmes (+)

 

 

 

 

Rotation vers la gauche

Recul dans l’archive des alarmes (–)

 

3.3Diodes électroluminescentes

LED

Etat

Fonction

 

L1 vert

Eteint

Appareil hors tension

 

 

 

 

 

 

Allumé

Appareil en service sans panne

 

 

Clignotant

Panne de l’appareil comme message collectif

 

 

Appareil défectueux et/ou panne du canal vidéo

 

 

 

 

 

 

 

 

L2 rouge

Eteint

Aucune alarme, non amorcée

 

(avec L1 allumé)

 

 

 

 

 

 

 

 

 

Allumé

Aucune alarme, amorcée

 

 

 

 

 

 

Clignotant

Objet détecté / alarme en attente

 

 

 

 

 

L2 rouge

Eteint

Aucune défaillance du signal vidéo,

 

(avec L1 clignotant)

panne de l’appareil

 

 

 

 

Allumé

Aucun signal vidéo, aucune panne générale de l’appareil

 

 

 

 

 

 

 

Défaillance du signal vidéo :

 

 

Clignotant

1. Signal utile / de bruit trop faible

 

 

2. Caméra éblouie

 

 

 

 

 

 

3. Eclairage de scène trop faible

 

 

 

 

 

– 25 –

A1 February 03/Trb

Suite Fonctions

Français

 

 

3.4Configuration des contacts

Broche

 

Fonction

 

Spécification électr.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Entrée de contact I

 

pull-up interne

 

 

 

ouvert : détecteur amorcé

 

 

 

 

 

 

 

 

 

 

sur Ground (broche 5) : détecteur pas amorcé

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Entrée de contact II

 

pull-up interne

 

 

 

ouvert : jeu de paramètres I actif

 

 

 

 

 

 

 

 

 

 

sur Ground (broche 5) :

 

 

 

 

 

 

 

 

 

 

jeu de paramètres II actif

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

Sortie de contact I

 

Open-Collector,

 

 

 

basculement interne sur Ground : objet détecté

max. 100 mA, 12 V

 

 

 

ouvert : aucun objet détecté

 

connexion externe

 

 

 

(signal continu, impulsion ou impulsion

 

 

 

 

 

 

 

 

 

 

périodique)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Sortie de contact II

 

Open-Collector,

 

 

 

basculement interne sur Ground :

 

max. 100 mA, 12 V

 

 

 

défaillance du signal vidéo

 

connexion externe

 

 

 

ouvert : signal vidéo correct

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

Ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

Relais I

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

max. 30 V, max. 1 A

 

 

6/7 fermé : panne

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

Relais I (contact central)

 

max. 30 V, max. 1 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

Relais I

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

max. 30 V, max. 1 A

 

 

8/7 fermé : aucune panne

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

Relais II

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

max. 30 V, max. 1 A

 

 

9/10 fermé : aucune alarme

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

Relais II (contact central)

 

max. 30 V, max. 1 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

Relais II

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

max. 30 V, max. 1 A

 

 

11/10 fermé : alarme

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

Télécommande commutateur rotatif :

 

pull-up interne

 

 

 

vers la gauche (–), retour dans l’arch. alarmes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

Télécommandecommutateur rotatif :

 

pull-up interne

 

 

 

– Basculement : Image en direct / arch. alarmes

 

 

 

 

 

 

 

 

 

 

– actif>2 s = sortie du mode alarme

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14

Télécommandecommutateur rotatif :

 

pull-up interne

 

 

 

vers la droite (+), progression dans l’arch. alarmes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

Télécommande commutateur rotatif : Ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Entrées de contact

 

 

 

 

 

 

 

+5V

Sorties de contact

3/4

 

 

 

 

 

 

 

 

 

Télécommande

1/2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12/13/14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5/15

 

 

5/15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

– 26 –

A1 February 03/Trb

4

Structure du système

Français

 

 

 

4.1Menus

Paramétrage

Jeu de paramètres 1

Alarmes – Jeu 1

Modes de fonctionnement – Jeu 1

Contacts d’alarme – Jeu 1

Paramètres de détection – Jeu 1

Zones sensibles – Jeu 1

Tailles d’objets / perspectives – Jeu 1

Direction du mouvement – Jeu 1

Jeu de paramètres 2

Alarmes – Jeu 2

Modes de fonctionnement – Jeu 2

Contacts d’alarme – Jeu 2

Paramètres de détection – Jeu 2

Zones sensibles – Jeu 2

Tailles d’objets / perspectives – Jeu 2

Direction du mouvement – Jeu 2

Copie du jeu de paramètres

Langue

Modification du code

Informations système

Sortie

– 27 –

A1 February 03/Trb

5

Paramétrage

Français

 

 

 

5.1Mise en service

Mettez l’appareil en service à température ambiante.

Assurez-vous au préalable que tous les composants sont correctement branchés. Respectez les instructions de montage !

Zones des menus

1

Zone de travail / image en direct

 

3

 

 

2

Textes d’aide

1

 

3

Logo de la société

4

 

4

Navigation utilisateur

 

 

 

 

2

 

5.1.1Commande

Lors du paramétrage, respectez toujours l’arborescence des menus et les textes d’aide dans la fenêtre inférieure du moniteur. Les symboles suivants sont utilisés pour la navigation :

= Abandon (rejet de la saisie, retour au niveau supérieur)

= Confirmation (acceptation de la modification, retour au niveau de menu supérieur)

= Correction (suppression de la saisie actuelle)

= Retour au niveau précédent

= Sortie

En l’absence d’indications particulières, utilisez le bouton gauche de la souris pour pointer et ajouter et le bouton droit pour supprimer.

5.1.2Code (préréglage 00000) / modification du code

Après la mise sous tension ou la « sortie » de la zone de paramétrage, vous devez attendre environ 5 secondes avant de pouvoir accéder à la fenêtre du code à l’aide de la souris.

Modification du code : entrez deux fois le nouveau code.

– 28 –

A1 February 03/Trb

Suite Paramétrage

Français

 

 

5.2Paramétrage

Lancement du paramétrage

Jeu de paramètres 1 ou = Jeu de paramètres 2

5.2.1 Jeu d’alarmes 1 ou 2

Mode de fonctionnement

Confirmation automatique, image en direct en cas d’alarme

Confirmation manuelle, image en direct en cas d’alarme

Confirmation manuelle, image d’alarme en cas d’alarme

Voir également le chapitre 6

Contacts d’alarme(sortie de contact I, voir 3.4)

Signal continu pendant la détection d’objet

Impulsion lors d’une nouvelle détection d’objet

Signal périodique lors de la détection d’objet

Signalisation d’alarmes

 

LED rouge

Relais II

Contact

 

clignotant

sortie

 

 

 

 

 

 

 

Pendant toute

Pendant toute

Pendant toute

Confirmation

la durée de

la durée de

la durée de dé-

détection d’un

détection d’un

tection d’un ob-

autom.

objet

objet

jet ou impulsion

 

 

 

 

 

Confirmation

Pendant toute

Pendant toute

Pendant toute

la durée

la durée

la durée de dé-

manuelle

d’attente

d’attente

tection d’un ob-

 

d’une alarme

d’une alarme

jet ou impulsion

 

 

 

 

– 29 –

A1 February 03/Trb

Suite Paramétrage

Français

 

 

5.2.2 Jeu de paramètres de détection 1 ou 2

Reportez-vous à la section 3.1 (lignes de brouillage)

Zones sensibles – Jeu 1 ou 2

Des zones sensibles non obscurcies apparaissent sur l’image en direct. Utilisez le bouton droit de la souris pour faire glisser des zones non sensibles carrées. Après avoir relâché le bouton de la souris, elles sont délimitées et obscurcies. Plusieurs zones non sensibles de taille différente peuvent être réparties sur l’image. A l’aide du bouton gauche de la souris, vous pouvez supprimer des zones non sensibles par écrasement ou les modifier, et ajouter des zones sensibles à l’aide du bouton droit.

Représentation de la taille d’un objet / perspective – Jeu 1 ou 2

Un petit carré apparaît sur l’image en direct. Sa taille correspond au réglage par défaut, pas au minimum. Aucune perspective n’est définie. Tout objet plus grand que le carré représenté est détecté. A l’aide du bouton gauche de la souris, vous pouvez modifier la taille du cadre, le faire glisser sur l’image ou tracer un autre cadre. Le cadre plus grand indique la taille d’objet minimale à détecter à l’avant-plan. Le cadre plus petit indique la taille d’objet minimale à l’arrière-plan. La position des cadres les uns par rapport aux autres indique la perspective définie. Veillez à ce que la position de la perspective soit toujours horizontale ou verticale, même si les carrés sur l’image sont disposés en diagonale. Si l’on considère les deux carrés comme extrémités d’un « L » parallèle aux bords de l’image, le côté le plus long donne la position. En cas de modification des rapports de taille des cadres, les couleurs ou le type de ligne changent également. A l’aide du bouton droit de la souris, vous pouvez également supprimer les carrés en faisant glisser un cadre. Si les deux carrés sont supprimés, le petit carré réapparaît.

– 30 –

A1 February 03/Trb

Loading...