Bosch PSU-224-DC100 User Manual

0 (0)

Power Supply

PSU-224-DC100

en Installation manual

Power Supply

Table of Contents | en 3

 

 

Table of Contents

 

 

 

 

1

Safety

4

1.1

Safety precautions

4

1.2

Important safety instructions

5

1.3

Important Notices

8

1.4

FCC & ICES compliance

9

1.5

UL certification

11

1.6

Bosch notices

12

 

 

 

2

Installation

13

2.1

Tools required

13

2.2

Opening the side covers

13

2.3

Mount the unit

13

2.4

Connecting the input cable

14

2.5

Connecting the output cables

15

 

 

 

3

Technical Data

16

3.1

Specifications

16

3.1.1

Dimensions

17

Bosch Security Systems

Installation manual

AR18-10-B002 | v1.1 | 2010.02

Bosch PSU-224-DC100 User Manual

4 en | Safety

Power Supply

 

 

1Safety

1.1Safety precautions

DANGER!

High risk: This symbol indicates an imminently hazardous situation such as "Dangerous Voltage" inside the product. If not avoided, this will result in an electrical shock, serious bodily injury, or death.

WARNING!

Medium risk: Indicates a potentially hazardous situation.

If not avoided, this could result in minor or moderate bodily injury.

CAUTION!

Low risk: Indicates a potentially hazardous situation.

If not avoided, this could result in property damage or risk of damage to the unit.

AR18-10-B002 | v1.1 | 2010.02

Installation manual

Bosch Security Systems

Power Supply

Safety | en

5

 

 

 

1.2Important safety instructions

Read, follow, and retain for future reference all of the following safety instructions. Heed all warnings on the unit and in the operating instructions before operating the unit.

1.Cleaning - Unplug the unit from the outlet before cleaning. Follow any instructions provided with the unit. Generally, using a dry cloth for cleaning is sufficient but a moist, flufffree cloth or leather shammy may also be used. Do not use liquid cleaners or aerosol cleaners.

2.Heat Sources - Do not install the unit near any heat sources such as radiators, heaters, stoves, or other equipment (including amplifiers) that produce heat.

3.Ventilation - Any openings in the unit enclosure are provided for ventilation to prevent overheating and ensure reliable operation. Do not block or cover these openings. Do not place the unit in an enclosure unless proper ventilation is provided, or the manufacturer's instructions have been adhered to.

4.Water - Do not use this unit near water, for example near a bathtub, washbowl, sink, laundry basket, in a damp or wet basement, near a swimming pool, in an outdoor installation, or in any area classified as a wet location. To reduce the risk of fire or electrical shock, do not expose this unit to rain or moisture.

5.Object and liquid entry - Never push objects of any kind into this unit through openings as they may touch dangerous voltage points or short-out parts that could result in a fire or electrical shock. Never spill liquid of any kind on the unit. Do not place objects filled with liquids, such as vases or cups, on the unit.

6.Lightning - For added protection during a lightning storm, or when leaving this unit unattended and unused for long periods, unplug the unit from the wall outlet and disconnect the cable system. This will prevent damage to the unit from lightning and power line surges.

Bosch Security Systems

Installation manual

AR18-10-B002 | v1.1 | 2010.02

6 en | Safety

Power Supply

 

 

7.Controls adjustment - Adjust only those controls specified in the operating instructions. Improper adjustment of other controls may cause damage to the unit. Use of controls or adjustments, or performance of procedures other than those specified, may result in hazardous radiation exposure.

8.Overloading - Do not overload outlets and extension cords. This can cause fire or electrical shock.

9.Power cord and plug protection - Protect the plug and power cord from foot traffic, being pinched by items placed upon or against them at electrical outlets, and its exit from the unit. For units intended to operate with 230 VAC, 50 Hz, the input and output power cord must comply with the latest versions of IEC Publication 227 or

IEC Publication 245.

10.Power disconnect - Units have power supplied to the unit whenever the power cord is inserted into the power source. The power cord plug is the main power disconnect device for switching off the voltage for all units.

11.Power sources - Operate the unit only from the type of power source indicated on the label. Before proceeding, be sure to disconnect the power from the cable to be installed into the unit.

For battery powered units, refer to the operating instructions.

For external power supplied units, use only the recommended or approved power supplies.

For limited power source units, this power source must comply with EN60950. Substitutions may damage the unit or cause fire or shock.

For 24 VAC units, voltage applied to the unit's power input should not exceed ±10%, or 28 VAC. Usersupplied wiring must comply with local electrical codes (Class 2 power levels). Do not ground the

AR18-10-B002 | v1.1 | 2010.02

Installation manual

Bosch Security Systems

Loading...