Bosch LBB 1925-10 User Manual

0 (0)
Bosch LBB 1925-10 User Manual

Communications Systems | LBB 1925/10 Plena System Pre-Amplifier

LBB 1925/10 Plena System Pre-Amplifier

www.boschsecurity.com

The Plena system pre-amplifier is a versatile, highperformance unit with call and mono BGM (background music). It fulfills a wide variety of public address requirements at a surprisingly low cost. It can provide dual channel operation for simultaneous calls and BGM for up to six different zones, using two Plena amplifiers.

Functions

The call channel provides two inputs for the Plena call stations, LBB 1941/00 (all-call) or LBB 1946/00 (sixzone), with loop-through capability, and universal, balanced input. One is a 3-pin XLR connector for microphone or line level (selectable), and the other is a 5-pin DIN-connector with all call priority contact, which may also be used to start one of the available chime attention signals.

The microphone input has a selectable speech filter for improved intelligibility, a volume control, and bass and treble tone controls with shelving characteristics optimized for speech. The call channel is available on the balanced XLR master output.

uSix-zone system pre-amplifier, with single or dual channel operation

uTwo input channels for call stations

uUniversal input for microphone/line, with speech optimized tone control

uThree inputs for BGM selection and music optimized tone control

uFront panel zone selection for BGM and call station zone selection for calls

The BGM channel provides three inputs on stereo cinch-connectors, converted to mono, with front panel selection, volume control and bass and treble tone controls with shelving characteristics optimized for music. The BGM channel has a direct output on balanced XLR for dual channel operation. It can also feed the master output, with the lowest priority, for single channel operation. Zone selector switches on the front panel control the BGM routing. An overload protected 24 VDC output provides power for driving external relays, often making an external power supply unnecessary.

An emergency/telephone input with signal level detector (VOX) and volume preset has the highest priority to all zones. Two trigger inputs (contact closure) activate alarm or time signals to pre-selected zones. Many different chime tones are available. A PC audio input with RS-232 control provides software controlled zone configuration, or automatic messaging in combination with the LBB 1965/00 Plena Message Manager. There are six levels of priority available for BGM, microphone, call stations, trigger inputs and emergency input. A set of relays directs the amplifier output(s) to different loudspeaker groups (zone switching).

2 | LBB 1925/10 Plena System Pre-Amplifier

Each zone has a tri-state control on the front panel that can turn it off, switch it to the call channel, or to the BGM channel. The all call microphone input and emergency activation override the call station selection on the call channel. Each zone has separate priority overrides with preset volume levels. This assures an appropriate message volume, independent of any local volume settings, such as for BGM. Both three wire and four wire override schemes are supported. An override also activates a voltage-free contact (call-active) available for external control and monitoring. The master output channel, or one of the input channels, can be monitored through the headphone connector and/or the LED VU meter.

Controls and indicators

Front

LED power meter

Power on LED

Call active LED

Three knobs for mic/line volume, treble, and bass levels

Three knobs for BGM volume, treble, and bass levels

BGM source selection knob

Six zone-selections keys

Six zone status LEDs

On/off switch

Back

EMG input volume control

Mains voltage switch

Interconnections

Front

Headphone jack

Back

One (DIN or XLR) Mic/line input

Two (DIN/DIN) call station inputs

PC audio (cinch) input

Priority input

Master (XLR) output

BGM (XLR) output

Emergency signal input

Two trigger inputs

RS-232 (DE-9)

Three (cinch) CD, tape, aux inputs

Six 100 V speaker outputs

24 VDC output

24 VDC input

Three control inputs

Ground screw

IEC mains socket

Certifications and approvals

Safety

acc. to EN 60065

 

 

Immunity

acc. to EN 55103-2

 

 

Emission

acc. to EN 55103-1

 

 

Region Certification

Europe CE

Installation/configuration notes

LBB 1925/10 rear view

Parts included

Quantity Component

1LBB 1925/10 PLENA System Pre-amplifier

1Power cord

1Set of 19”mounting brackets

1Plena CD

1Installation and User Instructions

Technical specifications

Electrical

Mains power supply

Voltage

230/115VAC, ±15%, 50/60 Hz

 

 

Current inrush

230/115 VAC, 1.5/3 A

 

 

Max power consumption

25 VA

 

 

Battery power supply

 

 

 

Voltage

24 VDC, +10% / -15%

 

 

Current max

1 A

 

 

Performance

 

 

 

Frequency response

50 Hz to 20 kHz (+1 / -3 dB)

 

 

Distortion

<0.5%

 

 

Bass control

±10 dB @ 100 Hz

 

 

Treble control

±10 dB @ 10 kHz

 

 

Channel separation

>70 dB @ 1 kHz

 

 

Priority mute

>40 dB

 

 

Dynamic range

100 dB

 

 

Mic/line input

1 x

 

 

Connectors

5 pin DIN, 3 pin XLR, balanced, with

 

phantom power

 

 

Sensitivity

1 mV (mic), 200 mV (line)

 

 

Loading...
+ 2 hidden pages