Bosch GWH-635-ES User Manual

5 (1)

Index

Index

1

Warning

2

 

 

 

2

Appliance details

4

2.1

Features

4

2.2

GWH-635-ES Specifications (Technical data)

4

2.3

Dimensions and Minimum installation clearances

6

2.4

General rules to follow for safe operation

7

2.5

Proper location for installing your heater

7

2.6

Clearances

8

2.7

Mounting installation

8

2.8

Combustion air requirements

8

2.9

Venting

9

2.9.1

Venting options

12

2.10

Gas piping & connections

15

2.11

Gas line sizing

17

2.12

Measuring gas pressure

17

2.12.1

Connecting Manometer

17

2.12.2

Static Pressure Test

17

2.12.3

Operating Pressure Test

17

2.13

Water connections

18

2.14

Electrical connections

19

2.15

Operating instructions

19

2.16

For your safety read before operating your water heater

19

2.17

Lighting and operating instructions

19

 

 

 

3

Operation instructions

21

3.1

Power

21

3.2

Temperature selection

21

3.3

Use of remote control accessory

23

3.4

Operation

23

3.5

Reset button

23

3.6

Program button

23

3.7

Locked condition

23

 

 

 

4

Maintenance and service

24

 

 

 

5

Troubleshooting

24

 

 

 

6

Electrical diagram

27

 

 

 

7

GWH-635-ES Functional scheme

28

 

 

 

8

Interior components diagram and parts list

29

8.1

Interior components

29

8.2

Components diagram

30

8.3

Parts list

31

9Special adjustment for measuring and adjusting CO2

 

levels

32

 

 

 

10

Protecting the environment

34

 

 

 

11

Fifteen Year Limited Warranty

35

1Warning

Warning: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.

Warning: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier.

Upon completion of the installation, these instructions should be handed to the user of the appliance for future reference.

Featuring

Electronic Ignition and Power Venting

For your safety

Do not store or use gasoline or other flammable, combustible or corrosive vapors and liquids in the vicinity of this or any other appliance.

Warning: Carefully plan where you install the heater. Correct combustion air supply and flue pipe installation are very important. If a gas appliance is not installed correctly, fatal accidents can result from lack of air, carbon monoxide poisoning or fire.

Warning: Exhaust gas must be vented to outside using proper vent material suitable for category III vent systems and temperatures up to 480°F. Vent and combustion air connector piping must be sealed gas-tight to prevent possibility of flue gas spillage, carbon monoxide emissions and risk of fire, resulting in severe personal injury or death.

Warning: Place the heater in a location where water leaks will do NO DAMAGE to adjacent areas or lower floors.

2

6 720 607 072

Bosch GWH-635-ES User Manual

Warning

Warning: Field wiring connections and electrical grounding must comply with local codes, or in the absence of local codes, with the latest edition of the National Electric Code, ANSI/NFPA 70, or in Canada, all electrical wiring must comply with the local codes and the Canadian Electrical Code, CSA C22.1 Part 1.

Warning: Shock hazard line voltage is present. Before servicing the water heater, turn off the electrical power to the water heater at the main disconnect or circuit breaker. Failure to do so could result in severe personal injury or death.

What to do if you smell gas

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Close gas valve. Open windows.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Do not try to light any appliance.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Do not touch any electrical switch; do not use any

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

phone in your building.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Immediately call your gas supplier from a neighbor’s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

phone. Follow the gas supplier’s instructions.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If you cannot reach your gas supplier, call the fire

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

department.

 

Fig. 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Installation and service must be

performed by a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

qualified installer, service agency or the gas supplier.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Warning: The heater

must be

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

disconnected from the gas supply

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

piping system during any pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

testing of that system at test pressures

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

equal to or more than 0.5 psig.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FCC:

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Fig. 2

6 720 607 072

3

Appliance details

2Appliance details

2.1Features

Parts

Touch Pad interface control

High power pre-mix compact burner with low Nox emissions

Modulating Gas Valve with constant gas:air ratio control

Modulating water valve for improved comfort and temperature control.

Safety

Flame sensor (ionization) rod

Overheat sensor

Temperature limiter

Fan speed monitoring.

High Quality Materials for Long Working Life

Copper heat exchanger

High efficiency Ceramat Burner

Compact space saver: mounts on a wall with a supplied bracket.

Easily removable one-piece cover.

Features

LCD Display

On/Off and Temperature control switches

Reset button

Program Key (Selectable temperature default)

Failure codes for easy diagnostic and repair. Accessories

Optional wireless remote control accessory to operate with the appliance

Vent termination kit.

BOSCH is constantly improving its

iproducts, therefore specifications are subject to change without prior notice.

2.2GWH-635-ES Specifications (Technical data)

Approved in US/Canada

Capacity

Maximum flow rate: 6.35 GPM (24 l/min) at a 45°F (25°C) rise.

Maximum output

142,968 Btu/h (41.8 kW)

Maximum input

175,000 Btu/h (51.2 kW)

Efficiency in %

Recovery efficiency 86.5%

Min. Output

31,131 Btu/h (9.1 kW)

Temperature Control

Selection range: 100°F (38°C) - 140°F (60°C) Default temperature: 122°F (50°C)

Stability: +/- 2°F (+/- 1°C)

Gas Requirement

Gas connection (inches) - ¾”

Inlet gas pressure under operation (with a high hot water flow rate)*

Propane: 11” - 14” water column

Natural Gas: 5” - 14” water column.

* To measure Gas Pressure, see Measuring Gas Pressure, chapter 2.12.

Venting

A condensate trap is integrated into the exhaust flue gas collar of the heater, the supplied condensate drain tube must be installed to it for proper removal of condensate from the trap. See chapter 2.9 for Venting.

Water

Hot water connection (inches) - ¾”

Cold water connection (inches) - ¾”

Water valve material: Polymer (PPS) (Polypropylene Sulfid)

Minimum water flow: 0.8 gallon/minute (3 l/m)

Minimum recommended water pressure: 30 PSI (2.07 bar)

Connections:

– Bottom of heater

4

6 720 607 072

Combustion

NOx 55 ppm

CO 250 ppm

CO2 level set from factory, see chapter 9.

Dimensions

Depth (in): 8 ½” (220 mm)

Width (in): 15 ¾” (400 mm)

Height (in): 23 ½” (600 mm)

Weight: 47 pounds (21 kg).

Gas types

Natural Gas. LP Gas.

Converting the gas type can only be done by a certified gas technician with a calibrated CO2 analyzer.

Call BBTNA for conversion instructions.

Voltage

120 V AC (50/60 Hz)

Amperage

IDLE - 40 mA

Operation - 2,5 A

Noise

50 db (A)

Safety devices

Flame failure device (ionization flame rod sensor)

Pressure relief valve (supplied with heater)

Over heat prevention (temperature limiter).

Water resistant

IP X4 (protection against water drops)

UNPACKING THE GWH-635-ES HEATER

This heater is packed securely. The box includes:

Pressure relief valve (150 psi / 200,000 Btu rating)

Bracket for wall hanging the heater

Exhaust vent adaptor (with 4 screws and gasket provided)

Condensate drain tube kit

Combustion air inlet adaptor (with 3 screws and gasket provided)

Plastic decal shields for covering front cover screws and control panel, installer should affix these decals to the front of the unit after installation is complete. See Fig. 3

Installation manual

Product registration card

Energy Guide label.

Appliance details

Do not lose this manual. Please complete and return the enclosed product registration card.

Before installing the unit, be certain you have the correct heater for your type of Gas - Propane or Natural Gas. Identification labels are found on the shipping box, and on the rating plate which is located on the right side panel of the cover.

To remove front cover

Loosen the two Philips head screws located on front panel (beneath plastic decal shields if they are already attached, see Fig. 3)

Lift front cover panel upward and remove.

Fig. 3 Remove front cover

The GWH-635-ES is not approved or designed for:

Manufactured (mobile) homes, RV's or boats

Heating or other recirculating/pumping applications*

Outdoor installation (use only Outdoor Model GWH- 635-ESO)

Solar/preheat backup or high temperature booster use.

* This includes domestic hot water circulator pump loop systems that may previously exist in a home hot water system. The use of a small electric mini-tank (4-6 gallon size) should be used for this application; when designed so the pump will circulate the hot water in the mini-tank only and through the building's hot water return loop (timed or thermostatic controlled operation of the pump is commonly done). The GWH-635-ES should be plumbed in line before the mini-tank water heater, contact BBTNA if further instruction is needed.

6 720 607 072

5

Appliance details

2.3Dimensions and Minimum installation clearances

Fig. 4 Dimensions

1Cover

2 On/Off switch

3 Reset button

4 LCD display

5 Program button

6 Temperature buttons

Fig. 5 Minimum clearances

 

Model GWH-635-ES

TOP (A)

12”

FRONT (B)

1”

BACK

0”

SIDES

1”

FLOOR (C)

12”

VENT DIAMETER

3”

Table 1 Minimum clearances

6

6 720 607 072

Appliance details

2.4General rules to follow for safe operation

B1. You should follow these instructions when you install your heater. In the United States: The installation must conform with local codes or, in the absence of local codes, the National Fuel Gas Code ANSI Z223.1/NFPA 54.

In Canada: The Installation should conform with CGA B149.(1,2) INSTALLATION CODES and /or local installation codes.

B2. Carefully plan where you install the heater. Correct combustion air supply and vent pipe installation are very important. If not installed correctly, fatal accidents can be caused by lack of air, carbon monoxide poisoning or fire.

B3. When the unit is installed indoors and ROOM SEALED (twin pipe) it is permitted to be located in bathrooms, bedrooms and occupied rooms that are normally kept closed. See chapter 2.9. If the unit will be installed indoors and use indoor combustion air, the place where you install the heater must have enough ventilation. The National Fire Codes do not allow UNSEALED gas fired water heater installations in bathrooms, bedrooms or any occupied rooms normally kept closed. See chapter 2.5 and 2.8.

B4. You must vent your heater. See section on VENTING.

B5. The appliance and its gas connection must be leak tested before placing the appliance in operation. The appliance must be isolated from the gas supply piping system by closing its individual manual gas shutoff valve (not supplied with heater) during any pressure testing at pressures in excess of ½ Psig (3.5 kPa).

B6. Keep water heater area clear and free from combustibles and flammable liquids. Do not locate the heater over any material which might burn.

B7. Correct gas pressure is critical for the optimum operation of this heater. Gas piping must be sized to provide the required pressure at the maximum output of the heater, while all the other gas appliances are in operation. Check with your local gas supplier, and see the section on connecting the gas supply.

B8. Should overheating occur or the gas supply fail to shut off, turn off the gas supply at the manual gas shut off valve, on the gas line. Note: manual gas shutoff valve is not supplied with the heater.

B9. Do not use this appliance if any part has been underwater. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been underwater

2.5Proper location for installing your heater

Carefully select the location of the water heater. For your safety and for proper heater operation, you must provide combustion air to the heater and a proper exhaust vent system.

Follow the guidelines below:

B 1. Locate the heater where venting, gas and plumbing connections are feasible and convenient.

B 2. It is strongly recommended that the heater be installed as a ROOM SEALED heater (twin pipe). If the heater will be installed as an UNSEALED heater (sing368 0 Td (r)Tj 3.12233 0 Td (e)Tj 5.28395 0

6 720 607 072

7

Appliance details

2.6Clearances

The GWH-635-ES is design certified for installation on a combustible wall (see 2.7 Mounting installation) provided the floor covering below the heater is noncombustible. For installations in an alcove or closet, maintain the minimum clearances to combustible and non-combustible materials listed below. See also Fig. 5.

A.Top 12 inches (306 mm)

B.Front 1 inches (25 mm)

C.Back 0 inches

D.Sides 1 inches (25 mm)

E.Bottom 12 inches (306 mm)

Clearances from any exhaust vent pipe are dependent upon the clearance requirements of the stainless steel vent pipe manufacturer. Single wall stainless steel (AL29-4C) vent pipe (vent type rated for Category III appliances) must be used when exhaust venting this appliance. See 2.9 Venting.

2.7Mounting installation

Fig. 6 Mounting the heater

2.8 Combustion air requirements

The GWH-635-E5Sis a sealeg water

heat er and it

The GWH-635-ES is design certified for mounting on a wall. Secure the wall mounting bracket provided with the heater to a wall surface. See Fig. 6.

Do not install this appliance on a carpeted wall or over floor covering which is combustible, such as carpet. The heater must be mounted on a wall using appropriate anchoring materials.

If the mounting bracket is unable to line up on two wall studs it is recommended that support board(s), either 1x4's or ½" (minimum) plywood first be attached across a pair of studs and then the heater should be attached to the support boards. The heater should be kept level on the wall surface. See Fig. 6.

Expansion and contraction of piping due to changing water temperature in the pipes imparts movement to the heater which, if mounted directly to a brittle, friable board, such as plasterboard, can cause failure of mounting.

Before installing the unit, be certain you have the correct heater for your type of Gas - Propane or Natural Gas. Identification labels are found on the shipping box, and on the rating plate which is located on the right side panel of the cover.

8

6 720 607 072

Appliance details

construction, infiltration air is normally adequate to provide air for combustion.

Appliances located in confined spaces:

The confined space must be provided with two permanent openings, one commencing within 12 inches (304.8mm) of the top and one commencing within 12 inches (304.8mm) of the bottom of the enclosure. Each opening must have a minimum free area of one square inch per:

1000 Btu/hr (292.81 Watts) if all air is taken from inside the building

2000 Btu/hr (585.62 Watts) if all air is taken from the outside by horizontal ducts

4000 Btu/hr (1171.24 Watts)if all air is taken from the outside by direct openings or vertical ducts

Or the confined space must be provided with one permanent opening or duct that is within 12 inches (304.8mm) of the ceiling of the enclosure. This opening must have a minimum free area of one square inch per:

3000 Btu/hr (878.43 Watts) if all air is taken from the outside by a direct opening or vertical duct.

Louvers, grills and screens have a blocking effect, when used, increase the sizes of your openings by 300% for wood louvers (as wood type will reduce the free air by 75%) and 40% for metal louvers (as metal will reduce the free air by 30%). Refer to the National Fuel Gas Code for complete information. In buildings of tight construction all air should be taken from outside.

NOTE: It is not recommended to use interior room air (SINGLE PIPE vent system) in areas that commonly experience below freezing temperatures. Clothes dryers, furnaces, woodstoves, bathroom or kitchen fans or other gas appliances can create negative air pressure when operating by removing air from the building. Cold air will be drawn back into the building, and if drawn through the water heater a freezing situation may occur. TWIN PIPE (room sealed) method of venting is recommended, see page 12.

NOTE: When installed in beauty shops, barber shops, or other facilities where chemicals that generate corrosive or flammable products such as aerosol sprays are routinely used, shall be installed as sealed unit following the TWIN PIPE SYSTEM method of venting.

2.9Venting

Warning: Do not reduce the vent (exhaust and combustion) pipe sizes and do not common vent with any other vented appliance or stove.

NOTE: This appliance's exhaust must be vented to the outside1 with sealed stainless steel vent pipe (AL29-4C), the minimum vent length is 3 feet (a 90 degree vent elbow is equivalent to 2 ½ feet). The appliance's flue gasses are under positive pressure and must travel through a stainless steel 3" or 4" pipe that is sealed gas tight.

NOTE: The exhaust collar on the water heater is 3" diameter and its collar must always be used, a 3" to 4" increaser will be required to be first connected to the exhaust collar when 4" venting is used. Different stainless steel vent manufacturer's have different joint systems, do not mix vent pipe or joining methods from different manufacturer's.

Stainless steel vent pipe is equipped with sealing gaskets for ease of installation, proper safety and durability. The heater shall not be vented in combination with any other appliance; the appliance must only be vented with a dedicated sealed vent system.

 

Z flex

Protech

Heat Fab

BBTNA

 

 

 

 

 

3” VENTING

 

 

 

 

3” Horizontal

 

 

 

 

Terminal

2SVSTB03

FSTB3

9390 TEE

2SVSTB03

 

 

 

 

 

3” Vertical

2SVSRCF03

FSRC3

5300CI

2SVSRCF03

terminal

 

 

 

 

 

 

 

 

 

4” VENTING

 

 

 

 

Requires a 3”

 

 

 

 

to 4” Increaser

2SVI0304

FS0304TI

9374

2SVI0304

 

 

 

 

 

4” Horizontal

2SVSRTF04

FSTB4

9490TEE

FXHOOD

terminal

 

 

 

 

 

 

 

 

 

4” Vertical

2SVSRCF04

FSRC4

5400CI

----------

terminal

 

 

 

 

 

 

 

 

 

Table 2 Terminals/Adapters Part Numbers

Caution: The vent system must be installed by a qualified agency in accordance with these instructions. If improperly installed a hazardous condition such as explosion or Carbon Monoxide poisoning could result. BBTNA will not be responsible for improperly installed appliances.

Establish vent clearances that comply with the vent manufacturer's specifications. In all cases follow local codes. See table 3.

6 720 607 072

9

Appliance details

The maximum flue gas exhaust temperature on the GWH-635-ES is 437°F (225°C)

Venting

Exhaust

* Exhaust

* Exhaust

Combustion

Combustion

Vent pipe

Vent pipe

Options

vent

vent

vent

air pipe

air pipe

clearances

clearances

 

diameter

maximum

minimum

diameter

maximum

within an

within an

 

and

length

length

and material

length

unenclosed

enclosed

 

material

 

 

 

 

space

space

Room

3 or 4+

26 feet (8

3 feet

3 inch PVC,

26 feet (8

** See vent

** See vent

sealed

inch

m) with one

 

aluminum or

m) with one

manufacturer's

manufacturer's

(twin pipe)

stainless

elbow. Less

 

galvanized

elbow. Less

specifications

specifications

 

steel

2½ feet for

 

pipe

2½ feet for

 

 

 

(AL29-4C)

each

 

 

each

 

 

 

sealed vent

additional

 

 

additional

 

 

 

pipe

90° elbow

 

 

90° elbow

 

 

Open

3 or 4+

26 feet (8

3 feet

See

See

** See vent

** See vent

combustion

inch

m) with one

 

chapter 2.8

chapter 2.8

manufacturer's

manufacturer's

(single

stainless

elbow. Less

 

 

 

specifications

specifications

pipe)

steel

2½ feet for

 

 

 

 

 

 

(AL29-4C)

each

 

 

 

 

 

 

sealed vent

additional

 

 

 

 

 

 

pipe

90° elbow

 

 

 

 

 

 

 

 

 

 

 

 

 

Exhaust vent is always fan assisted. Installation of exhaust vent and combustion air piping may be run vertically or horizontally and in separate directions if required.

+ The exhaust collar on the water heater is 3" diameter and its collar must always be used, a 3" to 4" increaser will be required to be first connected to the exhaust collar when 4" venting is used.

* A maximum of three 90 degree elbows are permitted in both the exhaust and combustion air vent lengths. The total vent length must be reduced by 1 ¼ feet for every 45° elbow used in the vent system.

** Stainless steel (AL29-4C) vent pipe is manufacturerd by Z-Flex, Protech and Heat Fab. NOTE: clearance distances are variable depending if the vent pipe is installed in an enclosed or unenclosed space, the exhaust flue gas temperature and the orientation of the vent pipe.

Table 3

The appliance should be located as close to the point of termination as possible. The maximum vent length is 26 feet (8 m) with one 90 degree elbow. Subtract 2½ feet from the total vent length for each additional 90° elbow used (a maximum of three 90° elbows are permitted in the total vent length), or subtract 1 ¼ feet for every 45° elbow used. Horizontal sections of vent must pitch ¼" for every foot of horizontal length, to prevent the pooling of condensate, and be supported at 4 foot intervals with overhead hangers.

Note: Listed thimbles or collars are necessary to pass through wall and ceiling partitions. If the vent system passes through combustible areas where the vent clearance requirements cannot be maintained, it is permissible to chase straight sections of sealed 3 inch single wall vent through 4 inch (or greater) Type-B vent. The distance to combustibles using this chase technique is 1 inch. Note: Type-B vent should never be used as the actual exhaust vent system for the appliance, as it is not gas tight.

Minimum exhaust vent size and length

Fig. 7

Maximum exhaust vent and combustion air inlet lengths

Fig. 8

10

6 720 607 072

Note: reduce 2½ ft for each 90° elbow used after the first one, reduce 1 ¼ ft for each 45° elbow.

Vent Safety System

The GWH-635-ES will shut down if inadequate exhaust venting is detected or a lack of combustion air is provided to the unit; see troubleshooting section on page 24. See error code to confirm error, correct the problem and then reset the heater before operating.

Attaching the exhaust and air inlet connection adaptors to the top of the heater

Appliance details

Use of the external condensate drain tube kit (supplied with the heater) on the exhaust collar

BThe condensate drain tube kit must be used for all installation types. Failure to install condensate drain will void the warranty.

BWhen installing the condensate drain tube kit at the exhaust collar (see diagram below), be sure to form a trap by means of a 3" (76.2 mm) loop filled with water. The supplied tube is 3/8" ID high temperature silicone and must be attached to the condensate tapping on the exhaust collar with its supplied gear clamp (first remove screw at tapping point).

BTo increase tube length, connect vinyl type tubing after the supplied tube.

BThe condensate must be disposed of according to local regulations.

Fig. 9

Fig. 11

Fig. 10

BAttach the flue gas exhaust accessory (8 705 504

114)to the top of the unit (position 1) using the 4 screws and gasket provided, and fully insert 3" stainless steel vent pipe into the accessory and tighten the clamp (position 2).

BAttach the combustion air inlet accessory (8 705 504 115) to the top of the unit (position 3) using the 3 screws and gasket provided, and fully insert 3" combustion air pipe into the accessory and tighten the clamp (position 4). NOTE: The appliance has the possibility to mount the combustion air inlet accessory on the top right or on the top left side of the heater. The combustion air inlet that is not used must be kept sealed.

6 720 607 072

11