Bosch VKN 5085, VKC 4075, NKN 710XX User Manual

0 (0)
DINION Housing Kit
VKC 4075 | VKN 5085 | NKN 710xx
en Installation Manual

Table of contents

1
Safety 4
1.3 Important safety instructions 5
1.4 FCC and ICES compliance 6
1.5 Notices 6
2
Short information 7
3
System overview 8
4
Planning information 9
5
Installation 11
5.3 Pulling cables through mount 13
6
Connecting cables in housing 14
6.1 Cable and gland requirements 14
6.2 Feed cables through the housing base 14
6.3 Feed cables through the housing rear 15
6.4 Power connections 16
6.4.1 Incoming power safety earth connection 16
6.4.2 Incoming power wires 17
6.5 Camera connections 18
6.6 Housings with rear connectors 19
6.6.1 Connection – Rear housing video connection 19
6.6.2 Connection – Rear housing power connection 19
6.6.3 Connection - rear housing feed-through fitting 19
7
Configuration and final assembly 20
7.1 Camera Operation 20
7.2 Configuring IP camera kits 20
7.3 Configuring analog camera kits 21
7.4 Closing the housing 23
7.5 Positioning sunshield 23
8
Maintenance 24
8.1 Fuse replacement 24
9
Decommissioning 25
10
Technical data 26
DINION Housing Kit Table of Contents | en 3
Bosch Security Systems Installation Manual 2014.11 | 1.0 | F.01U.309.609

Safety

Safety message explanation

Danger!
Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
!
Warning!
Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
!
Caution!
Indicates a hazardous situation which, if not avoided, could result in minor or moderate
injury.
Notice!
Indicates a situation which, if not avoided, could result in damage to the equipment or
environment, or data loss.

Safety precautions

!
Warning!
Hazardous voltage
Use caution when working inside the housing. Hazardous voltage is present in the housing
when connected to the AC supply. Do not touch the power terminals when the unit is
powered.
!
Caution!
Installation should only be performed by qualified service personnel in accordance with the
National Electrical Code (NEC 800 CEC Section 60) or applicable local codes.
!
Caution!
This device must be connected to earth (ground).
Safety (power) ground is indicated by the symbol.
!
Caution!
These units must be properly and securely mounted to a supporting structure capable of
sustaining the unit weight. Use care when selecting mounts or pan/tilts (not supplied) for
installation; the mounting surface and unit's weight should be carefully considered.
!
Caution!
To protect the device, the branch circuit protection must be secured with a maximum fuse
rating of 16A. This must be in accordance with NEC 800 (CEC Section 60).
1
1.1
1.2
4 en | Safety DINION Housing Kit
2014.11 | 1.0 | F.01U.309.609 Installation Manual Bosch Security Systems

Important safety instructions

Read, follow, and retain for future reference all of the following safety instructions. Follow all
warnings before operating the unit.
1. Clean only with a dry cloth. Do not use liquid cleaners or aerosol cleaners.
2. Do not install unit near any heat sources such as radiators, heaters, stoves, or other
equipment (including amplifiers) that produce heat.
3. Never spill liquid of any kind on the unit.
4. Take precautions to protect the unit from power and lightning surges.
5. Adjust only those controls specified in the operating instructions.
6. Operate the unit only from the type of power source indicated on the label.
7. Unless qualified, do not attempt to service a damaged unit yourself. Refer all servicing to
qualified service personnel.
8. Install in accordance with the manufacturer's instructions in accordance with applicable
local codes.
9. Use only attachments/accessories specified by the manufacturer.
Power disconnect - Units have power supplied whenever the power cord is inserted into the
power source. The power cord is the main power disconnect for all units.
All-pole power switch - Incorporate an all-pole power switch, with a contact separation of at
least 3 mm, into the electrical installation of the building. If it is needed to open the housing,
use this all-pole switch as the main disconnect device for switching off the voltage to the unit.
Coax grounding:
Ground the cable system if connecting an outside cable system to the unit.
Connect outdoor equipment to the unit's inputs only after this unit has had its grounding
plug connected to a grounded outlet or its ground terminal is properly connected to a
ground source.
Disconnect the unit's input connectors from outdoor equipment before disconnecting the
grounding plug or grounding terminal.
Follow proper safety precautions such as grounding for any outdoor device connected to
this unit.
Section 810 of the National Electrical Code, ANSI/NFPA No.70, provides information regarding
proper grounding of the mount and supporting structure, grounding of the coax to a discharge
unit, size of grounding conductors, location of discharge unit, connection to grounding
electrodes, and requirements for the grounding electrode.
1.3
DINION Housing Kit Safety | en 5
Bosch Security Systems Installation Manual 2014.11 | 1.0 | F.01U.309.609

FCC and ICES compliance

FCC & ICES Information
(U.S.A. and Canadian Models Only)
This device complies with part 15 of the FCC Rules. Operation is subject to the following
conditions:
this device may not cause harmful interference, and
this device must accept any interference received, including interference that may cause
undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC Rules and ICES-003 of Industry Canada. These
limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses, and
radiates radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of
this equipment in a residential area is likely to cause harmful interference, in which case the
user will be required to correct the interference at his expense.
Intentional or unintentional modifications, not expressly approved by the party responsible for
compliance, shall not be made. Any such modifications could void the user's authority to
operate the equipment. If necessary, the user should consult the dealer or an experienced
radio/television technician for corrective action.
The user may find the following booklet, prepared by the Federal Communications
Commission, helpful: How to Identify and Resolve Radio-TV Interference Problems. This
booklet is available from the U.S. Government Printing Office, Washington, DC 20402, Stock
No. 004-000-00345-4.

Notices

Notice!
Optical elements are sensitive and should be protected at all times. Do not allow objects to
come into contact with glass surfaces and do not touch optical elements with your fingers.
Notice!
Video loss is inherent to digital video recording; therefore, Bosch Security Systems cannot be
held liable for any damage that results from missing video information.
To minimize the risk of losing information, we recommend multiple, redundant recording
systems, and a procedure to back up all analog and digital information.
Notice!
We recommend that memory cards only be used for local storage of alarm recordings.
1.4
1.5
6 en | Safety DINION Housing Kit
2014.11 | 1.0 | F.01U.309.609 Installation Manual Bosch Security Systems

Short information

This manual has been compiled with great care and the information it contains has been
thoroughly verified. The text was correct at the time of printing, however, the content can
change without notice. Bosch Security Systems accepts no liability for damage resulting
directly or indirectly from faults, incompleteness or discrepancies between this manual and
the product described.
Trademarks
All hardware and software product names used in this document are likely to be registered
trademarks and must be treated accordingly.
More information
For more information please contact the nearest Bosch Security Systems location or visit
www.boschsecurity.com
http://www.boschsecurity.com/catalog_overview.htm
2
DINION Housing Kit Short information | en 7
Bosch Security Systems Installation Manual 2014.11 | 1.0 | F.01U.309.609

System overview

These camera kits are complete camera packages that include a camera and lens installed
inside a sturdy (IP66 proof) housing. A feed-through wall mount is also provided. All kits are
equipped with a heater, blower and a sunshield. The maximum camera/lens size (H x W x D)
for all models is 91 x 81 x 262 mm (3.6 x 3.2 x10.3 in).
The kits are available with a choice of input power supply (24 VAC / 230 VAC), and various
connection possibilities:
housings with feed-through fittings in rear and base for power and signal cabling
housings with pre-wired cables through holes in base of housing
housings with rear connectors for a 4-pin power connector and a BNC connector, plus an
optional feed through fitting (for ethernet and other cabling)
IP camera kits can use the PoE supply (if connected) to directly power the camera via the
Ethernet cable (this can be seen as a backup to the normal camera power connection from the
housing PCB).

Available models

The following models are available:
Model Housing input
voltage
Camera type Connection Pre-wired
VKC--xxx-50 230 VAC DINION AN 4000 Power and BNC
connectors
No
VKN--xxx-50 230 VAC DINION AN 5000 Power and BNC
connectors
No
VKC--xxx-20 24 VAC DINION AN 4000 Feed-through Yes (power and
video cable)
VKN--xxx-20 24 VAC DINION AN 5000 Feed-through Yes (power and
video cable)
NKN-xxxxx-10N 24 VAC DINION IP 7000 Power and BNC
connectors
M20 fitting (for
Ethernet cable)
No
NKN-xxxxx-20N 24 VAC DINION IP 7000 Feed-through Yes (power
cable only)
3
3.1
8 en | System overview DINION Housing Kit
2014.11 | 1.0 | F.01U.309.609 Installation Manual Bosch Security Systems

Planning information

Parts list

Quantity Item Material
1 Housing (with installed sunshield, camera
and lens)
Aluminum
2 Screw, 1/4-20 x 0.5 in. Stainless Steel
2 Washer, spring M6 Stainless Steel
4 Screw, tamper-resistant M3.5 T15
1 Wrench, tamper-resistant M3.5 T15
1 Allen key 1/4-20 x 0.5 in.
3 Plug (installed in fitting in some models) M4 Silicone
1 Pink string (for pulling cables) Polyester
1 Feed-through wall mount Aluminum
1 Documentation packet
Cable fittings for models without pre-wiring
Quantity
Item Material
2 Cable gland, 3/8-in. NPT with locking nut Polyamide / neoprene
1 Cable gland, 1/2-in. NPT with locking nut Polyamide / neoprene
1 Cable gland, M20 x 1.5 Polyamide / neoprene
Analog models with rear connectors
Quantity
Item Material
1 4-pin cable connector, Female ABS
1 4-pin cable connector, Male ABS
4
4.1
DINION Housing Kit Planning information | en 9
Bosch Security Systems Installation Manual 2014.11 | 1.0 | F.01U.309.609
Loading...
+ 21 hidden pages