Conettix D6600/D6100
Computer Interface Manual
EN Receiver/Gateway
Conettix D6600/D6100 | Computer Interface Manual | Trademarks
Trademarks
Microsoft®, Windows®, Windows NT® are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries.
2 |
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 |
Conettix D6600/D6100 | Computer Interface Manual | Contents
Contents
1.0 |
System Connection .......................................... |
7 |
1.1Conettix D6680 Ethernet Network Adapter
|
Connection .......................................................... |
7 |
1.2 |
Direct Connection – RS-232 ............................. |
7 |
2.0 |
Making the Right Connection ....................... |
8 |
2.1 |
COM3 DB9 Connector ..................................... |
8 |
2.2Selecting Program Options in the
|
D6600/D6100 ..................................................... |
8 |
|
3.0 |
Computer Communication Protocols.......... |
9 |
|
3.1 |
D6500 Mode Messages ...................................... |
9 |
|
3.1.1 |
Acron Super Fast (Message Type 9)................. |
9 |
|
3.1.2 |
Ademco 4-1 |
Express (Message Type b)......... |
10 |
3.1.3 |
Ademco 4-2 |
Express (Message Type c) ......... |
10 |
3.1.4 |
Ademco Contact-ID (Message Type a).......... |
11 |
3.1.5Ademco High Speed, 4-8-1 (Message Type f)
|
............................................................................ |
11 |
3.1.6 |
ADT SIA (Message Type S) ............................ |
12 |
3.1.7 |
Caller ID (Message Type e)............................. |
12 |
3.1.8 |
CFSK (Message Type i) ................................... |
13 |
3.1.9 |
Common Formats (Message Type 1) ............. |
13 |
3.1.10 |
DNIS/ANI (Message Type N) ........................ |
14 |
3.1.11 |
DSC 4-3 (Message Type d).............................. |
14 |
3.1.12 |
FBI Super Fast (Message Type F) ................... |
15 |
3.1.13 |
ITI (Message Type I)........................................ |
15 |
3.1.14 |
Link Test (Message Type 1) ............................ |
15 |
3.1.15 |
Robofon (Message Type j)............................... |
16 |
3.1.16 |
Sescoa Super Speed (Message Type 7) .......... |
17 |
3.1.17Scancom 4-16-1, 5-16-1, 6-16-1 - Available
Upon Request (Message Type g) .................... |
18 |
3.1.18Scancom 4-24-1, 5-24-1, 6-24-1 - Available
Upon Request (Message Type h).................... |
19 |
3.1.19 Seriee FSK (Message Type k).......................... |
20 |
3.1.20 Seriee DTMF (Message Type l) ...................... |
20 |
3.1.21 SIA (Message Type S) ...................................... |
21 |
3.1.22 Silent Knight FSK0 (Message Type 1) ........... |
22 |
3.1.23 Silent Knight FSK2 (Message Type m) .......... |
24 |
3.1.24Silent Knight FSK80 D6500 mode (Message
Type E) .............................................................. |
24 |
3.1.25 Telim (Message Type n) .................................. |
25 |
3.1.26 Text Message (Message Type 3) ..................... |
25 |
3.1.27 Varitech FSK 4-1 (Message Type 1)............... |
26 |
3.1.28 Varitech FSK 4-2 (Message Type 1)............... |
26 |
3.1.29 VONK (Message Type V)............................... |
27 |
3.1.30 X-SIA Text (Message Type S)......................... |
27 |
3.1.31 SafeCom (Message Type p)............................. |
28 |
3.2 |
SIA Mode Messages ........................................ |
28 |
|
3.2.1 |
Acron Super Fast (Message Type 9) .............. |
28 |
|
3.2.2 |
Ademco Contact-ID (Message Type a) ......... |
29 |
|
3.2.3 |
Ademco 4-1 |
Express (Message Type b) ........ |
30 |
3.2.4 |
Ademco 4-2 |
Express (Message Type c)......... |
31 |
3.2.5Ademco High Speed 4-8-1, SCANCOM 4-8-1
|
(Message Type f) .............................................. |
32 |
3.2.6 ADT SIA (Message Type <TAB>) ................ |
33 |
|
3.2.7 |
Caller ID (Message Type <TAB>) ................ |
33 |
3.2.8 |
CFSK (Message Type I) .................................. |
34 |
3.2.9Common Formats (Message Type <TAB>) . 34
3.2.10 DNIS/ANI (Message Type N)........................ |
35 |
3.2.11 DSC 4-3 (Message Type d) ............................. |
36 |
3.2.12 FBI Super Fast (Message Type F) .................. |
37 |
3.2.13 ITI (Message Type I) ....................................... |
38 |
3.2.14 Link Test (Message Type <TAB>) ................ |
38 |
3.2.15 RB2000 (Message Type R) Description ........ |
39 |
3.2.16 Robofon (Message Type j) .............................. |
40 |
3.2.17Scancom 4-16-1, 5-16-1, 6-16-1 - Available
Upon Request (Message Type g) ................... |
40 |
3.2.18Scancom 4-24-1, 5-24-1, 6-24-1 - Available
|
Upon Request (Message Type h) ................... |
41 |
3.2.19 Seriee DTMF (Message Type l)...................... |
42 |
|
3.2.20 |
Seriee FSK (Message Type k) ......................... |
42 |
3.2.21 |
Sescoa Super Speed (Message Type 7).......... |
43 |
3.2.22Silent Knight FSK() (Message Type <TAB>) 44
3.2.23 Silent Knight FSK1 (Message Type m).......... |
44 |
|
3.2.24 Silent Knight FSK2 (Message Type m).......... |
46 |
|
3.2.25 |
Silent Knight FSK80 (Message Type E) ........ |
47 |
3.2.26 |
Telim (Message Type n).................................. |
48 |
3.2.27Varitech FSK 4-1 (Message Type <TAB>) . 48
3.2.28 |
Varitech FSK 4-2 (Message Type <TAB>) |
... 49 |
3.2.29 |
VONK (Message Type V) .............................. |
49 |
3.2.30 |
X-SIA text (Message Type <TAB>) .............. |
50 |
3.2.31 |
SafeCom (Message Type p) ............................ |
51 |
3.3 |
Input Command Processing ........................... |
52 |
Appendix A: Contact ID Event Code |
|
|
|
Classifications ................................................. |
53 |
Appendix B: Internal Messages................................ |
58 |
|
Appendix C: Modem IIIa2 Messages ....................... |
61 |
|
C.1 |
Zonex and Comex Translation .................... |
137 |
Appendix D: Network Messages (D6600 Only) .. |
138 |
|
Appendix E: Pulse Output ....................................... |
141 |
|
Appendix F: Format ID (by Message Type) – D6600 |
||
|
Only ................................................................ |
146 |
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 |
3 |
Conettix D6600/D6100 | Computer Interface Manual | Contents
Appendix G: ADT SIA Report Codes ................... |
149 |
|
Appendix H: D6600 RB2000 Messages .................. |
151 |
|
Appendix I: D6600 SafeCom Messages ................. |
158 |
|
Figures |
|
|
Figure 1: |
D6600 System – Standard/Network |
|
|
Automation .................................................. |
7 |
Figure 2: |
D6600 System – Direct Connect ............... |
7 |
Figure 3: |
D6100 System – Direct Connect ............... |
7 |
Figure 4: |
Null Modem Cable Configuration ............ |
8 |
Figure 5: |
Straight-through Modem Cable |
|
|
Configuration ............................................... |
8 |
Figure 6: |
Modem Cable Pin Definitions ................... |
8 |
Figure 7: |
Message sent to printer ............................. |
28 |
Figure 8: |
Message sent to printer ............................. |
29 |
Figure 9: |
Message sent to printer ............................. |
30 |
Figure 10: |
Message sent to printer ............................. |
31 |
Figure 11: |
Message sent to printer ............................. |
32 |
Figure 12: |
Message sent to printer ............................. |
34 |
Figure 13: |
Message sent to printer ............................. |
35 |
Figure 14: |
Message sent to printer ............................. |
35 |
Figure 15: |
Message sent to printer ............................. |
36 |
Figure 16: |
Message sent to printer ............................. |
37 |
Figure 17: |
Single message sent to Printer.................. |
39 |
Figure 18: |
Multiple messages sent to printer ............ |
39 |
Figure 19: |
Message sent to printer ............................. |
41 |
Figure 20: |
Message sent to printer ............................. |
41 |
Figure 21: |
Message sent to printer ............................. |
43 |
Figure 22: |
Message sent to printer ............................. |
47 |
Figure 23: |
Message sent to printer ............................. |
50 |
Figure 24: |
Contact ID format ..................................... |
53 |
Figure 25: |
D6200 Receiver Software Line Card |
|
|
Configuration ........................................... |
141 |
Tables |
|
|
Table 1: |
Recommended Programming Selections.. 8 |
|
Table 2: |
D6600 Line Number/Group Number |
|
|
Conversion Table ........................................ |
9 |
Table 3: |
Message Type 9 (Acron Super Fast) Byte |
|
|
Description ................................................... |
9 |
Table 4: |
Message Type b (Ademco 4-1 Express) |
|
|
Byte Description ........................................ |
10 |
Table 5: |
Message Type c (Ademco 4-2 Express) |
|
|
Byte Description ........................................ |
10 |
Table 6: |
Message Type a (Ademco Contact ID) |
|
|
Byte Description ........................................ |
11 |
Table 7: |
Message Type f (Ademco High Speed, 4-8- |
|
|
1) Byte Description.................................... |
11 |
Table 8: |
ADT SIA (Message Type S) Byte |
|
|
Description ................................................ |
12 |
Table 9: |
Caller ID (Message Type e) Byte |
|
|
Description ................................................ |
12 |
Table 10: |
CFSK (Message Type i) Byte Description |
|
|
.................................................................... |
13 |
Table 11: |
Common Formats (Message Type 1) Byte |
|
|
Description ................................................ |
13 |
Table 12: |
DNIS/ANI (Message Type N) Byte |
|
|
Description ................................................ |
14 |
Table 13: |
DSC-4-3 (Message Type d) Byte |
|
|
Description ................................................ |
14 |
Table 14: |
FBI Super Fast (Message Type F) Byte |
|
|
Description ................................................ |
15 |
Table 15: |
ITI (Message Type I) Byte Description.. 15 |
|
Table 16: |
Link Test (Message Type 1) Byte |
|
|
Description ................................................ |
16 |
Table 17: |
Robofon (Message Type j) Byte |
|
|
Description ................................................ |
16 |
Table 18: |
Sescoa Super Speed (Message Type 7) |
|
|
Byte Description........................................ |
17 |
Table 19: |
Scancom 4-16-1, 5-16-1, 6-16-1 - Available |
|
|
Upon Request (Message Type g) Byte |
|
|
Description ................................................ |
18 |
Table 20: |
Scancom 4-24-1, 5-24-1, 6-24-1 - Available |
|
|
Upon Request (Message Type h) Byte |
|
|
Description ................................................ |
19 |
Table 21: |
Seriee FSK (Message Type k) Byte |
|
|
Description ................................................ |
20 |
Table 22: |
Seriee DTMF (Message Type l) Byte |
|
|
Description ................................................ |
20 |
Table 23: |
SIA (Message Type S) Byte Description 21 |
|
Table 24: |
SIA (Message Type S) Byte Description. 21 |
|
Table 25: |
Silent Knight FSK1 (Message Type m) |
|
|
Byte Description........................................ |
22 |
Table 26: |
Optional Silent Knight SK1 (Message |
|
|
Type m) Byte Description........................ |
22 |
Table 27: |
Silent Knight Automation Format .......... |
23 |
Table 28: |
Silent Knight FSK2 (Message Type m) |
|
|
Byte Description........................................ |
24 |
Table 29: |
Silent Knight FSK80 (Message Type E) |
|
|
Byte Description........................................ |
24 |
Table 30: |
Telim (Message Type n) Byte Description |
|
|
.................................................................... |
25 |
Table 31: |
Text Message (Message Type 3) Byte |
|
|
Description ................................................ |
25 |
Table 32: |
Varitech FSK 4-1 (Message Type 1) Byte |
|
|
Description ................................................ |
26 |
Table 33: |
Varitech FSK 4-2 (Message Type 1) Byte |
|
|
Description ................................................ |
26 |
4 |
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 |
Conettix D6600/D6100 | Computer Interface Manual | Contents
Table 34: VONK (Message Type V) Byte |
|
|
|
Description ................................................. |
27 |
Table 35: X-SIA Text (Message Type S) Byte |
|
|
|
Description ................................................. |
27 |
Table 36: SafeCom (Message Type p) Byte |
|
|
|
Description ................................................. |
28 |
Table 37: Acron Super Fast (Message Type 9) Byte |
||
|
Description ................................................. |
28 |
Table 38: Acron Super Fast (Message Type 9) |
|
|
|
Printer Output............................................ |
28 |
Table 39: Ademco Contact-ID (Message Type a) |
|
|
|
Byte Description ........................................ |
29 |
Table 40: Ademco Contact-ID (Message Type a) |
|
|
|
Printer Output............................................ |
29 |
Table 41: Ademco 4-1 Express (Message Type b) |
|
|
|
Byte Description ........................................ |
30 |
Table 42: Ademco 4-1 Express (Message Type b) |
|
|
|
Printer Output............................................ |
30 |
Table 43: Ademco 4-2 Express (Message Type c) |
|
|
|
Byte Description ........................................ |
31 |
Table 44: Ademco 4-2 Express (Message Type c) |
|
|
|
Printer Output............................................ |
31 |
Table 45: Ademco High Speed 4-8-1, SCANCOM 4- |
||
|
8-1 (Message Type F) Byte Description ..32 |
|
Table 46: Ademco High Speed, 4-8-1 (Message Type |
||
|
f) Printer Output ........................................ |
32 |
Table 47: ADT SIA (Message Type <TAB>) Byte |
|
|
|
Description ................................................. |
33 |
Table 48: Caller ID (Message Type <TAB>) Byte |
|
|
|
Description ................................................. |
33 |
Table 49: |
CFSK (Message Type I) Byte Description |
|
|
..................................................................... |
34 |
Table 50: Common Formats (Message Type |
|
|
|
<TAB>) Byte Description ........................ |
34 |
Table 51: Common Formats (Message Type <TAB>) |
||
|
Byte Description ........................................ |
35 |
Table 52: DNIS/ANI (Message Type N) Byte |
|
|
|
Description ................................................. |
35 |
Table 53: DSC 4-3 (Message Type d) Byte |
|
|
|
Description ................................................. |
36 |
Table 54: |
DSC 4-3 (Message Type d) Printer Output |
|
|
..................................................................... |
36 |
Table 55: Event Code Table ..................................... |
36 |
|
Table 56: Printer Output Codes................................ |
36 |
|
Table 57: FBI Super Fast (Message Type F) Byte |
|
|
|
Description ................................................. |
37 |
Table 58: |
FBI Super Fast (Message Type F) Printer |
|
|
Output......................................................... |
37 |
Table 59: Event Code Table ..................................... |
37 |
|
Table 60: |
Printer Output Codes................................ |
37 |
Table 61: ITI (Message Type I) Byte Description.. |
38 |
|
Table 62: Link Test (Message Type <TAB>) |
|
|
|
Description ................................................ |
38 |
Table 63: RB2000 (Message Type R) Byte |
|
|
|
Description ................................................ |
39 |
Table 64: |
RB2000 (Message Type R) Printer Output |
|
|
.................................................................... |
39 |
Table 65: Robofon (Message Type j) Byte |
|
|
|
Description ................................................ |
40 |
Table 66: Scancom 4-16-1, 5-16-1, 6-16-1 - Available |
||
|
Upon Request (Message Type g) Byte |
|
|
Description ................................................ |
40 |
Table 67: Scancom 4-16-1, 5-16-1, 6-16-1 - Available |
||
|
Upon Request (Message Type g) Printer |
|
|
Output ........................................................ |
41 |
Table 68: Scancom 4-24-1, 5-24-1, 6-24-1 - Available |
||
|
Upon Request (Message Type h) Byte |
|
|
Description ................................................ |
41 |
Table 69: Scancom 4-24-1, 5-24-1, 6-24-1 - Available |
||
|
Upon Request (Message Type h) Printer |
|
|
Output ........................................................ |
41 |
Table 70: Seriee DTMF (Message Type l) Byte |
|
|
|
Description ................................................ |
42 |
Table 71: Seriee FSK (Message Type k) Byte |
|
|
|
Description ................................................ |
42 |
Table 72: Sescoa Super Speed (Message Type 7) |
|
|
|
Byte Description........................................ |
43 |
Table 73: Sescoa Super Speed (Message Type 7) |
|
|
|
Printer Output ........................................... |
43 |
Table 74: Silent Knight FSK0 (Message Type |
|
|
|
<TAB>) Byte Description........................ |
44 |
Table 75: Silent Knight FSK1 (Message Type m) |
|
|
|
Byte Description........................................ |
44 |
Table 76: Optional Silent Knight FSK1 (Message |
|
|
|
Type m) Byte Description........................ |
45 |
Table 77: Silent Knight FSK1 Optional Outputs.... |
45 |
|
Table 78: Silent Knight FSK2 (Message Type m) |
|
|
|
Byte Description........................................ |
46 |
Table 79: Silent Knight FSK80 (Message Type E) |
|
|
|
Byte Description........................................ |
47 |
Table 80: |
Silent Knight FSK80 Printer/LCD output |
|
|
.................................................................... |
47 |
Table 81: |
Telim (Message Type n) Byte Description |
|
|
.................................................................... |
48 |
Table 82: |
Varitech FSK 4-1 (Message Type <TAB>) |
|
|
Byte Description........................................ |
48 |
Table 83: Varitech FSK 4-2 (Message Type <TAB>) |
||
|
Byte Description........................................ |
49 |
Table 84: VONK (Message Type V) Byte |
|
|
|
Description ................................................ |
49 |
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 |
5 |
Conettix D6600/D6100 | Computer Interface Manual | Contents
Table 85: |
X-SIA text (Message Type <TAB>) Byte |
|
|
Description ................................................. |
50 |
Table 86: |
X-SIA Printer/LCD output ...................... |
50 |
Table 87: |
SafeCom (Message Type p) Byte |
|
|
Description ................................................. |
51 |
Table 88: |
ASCII Text Message to Automation Port |
|
|
..................................................................... |
52 |
Table 89: |
Input Command Output Messages ......... |
52 |
Table 90: |
Event Codes ............................................... |
53 |
Table 91: |
Internal Messages ...................................... |
58 |
Table 92: |
Modem IIIa2 Messages ............................. |
61 |
Table 93: |
Point to Zonex Translation..................... |
137 |
Table 94: |
User ID to Comex Translation .............. |
137 |
Table 95: |
Reported Zone/ID to Actual Point/ID .137 |
|
Table 96: |
Network Messages................................... |
138 |
Table 97: |
Pulse 3/1 Format ..................................... |
141 |
Table 98: |
Pulse 3/1E Menu 3.1.3.12 3-1 Extended |
|
|
Format = 1 ............................................... |
142 |
Table 99: |
Pulse 3/1E Menu 3.1.3.12 3-1 Extended |
|
|
Format = 2 ............................................... |
142 |
Table 100: |
Pulse 3/2 ................................................... |
143 |
Table 101: |
Pulse 4/1 ................................................... |
143 |
Table 102: |
Pulse 4/1E Menu 3.1.3.3 4/1 Extended = 1 |
|
|
................................................................... |
144 |
Table 103: |
Pulse 4/1E Menu 3.1.3.3 4/1 Extended = 2 |
|
|
................................................................... |
144 |
Table 104: |
Pulse 4/2 ................................................... |
145 |
Table 105: |
Pulse 4/3 ................................................... |
145 |
Table 106: |
Generic Byte Description ....................... |
146 |
Table 107: |
Generic SIA Byte Description ............... |
146 |
Table 108: |
Message Examples .................................. |
147 |
Table 109: |
ADT SIA Report Codes ......................... |
149 |
Table 110: |
D6600 RB2000 Messages ....................... |
151 |
Table 111: |
D6600 Virtual Line Conversion Table .158 |
|
Table 112: |
D6600 SafeCom Messages - Line Card or |
|
|
Account Signals ....................................... |
159 |
Table 113: |
D6600 SafeCom Messages - Intercepted |
|
|
Control Panel Signals.............................. |
162 |
Table 114: |
Explanation of Automation Output Items |
|
|
(within Message Body only) ................... |
164 |
Table 115: |
Explanation of Printer Output Items .... |
165 |
Table 116: |
Supported Event Codes .......................... |
166 |
6 |
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 |
Conettix D6600/D6100 | Computer Interface Manual | |
1.0 |
System Connection |
|
|
|
1.0System Connection
1.1Conettix D6680 Ethernet Network
Adapter Connection
Use the Conettix D6680 Ethernet Network Adapter to connect a manufacturer’s automation software package to the D6600 when the software cannot receive network data (Figure 1). Refer to the Special Conettix D6600 Applications in the Conettix D6600 System Guide
(P/N: 4998122712).
Figure 1: D6600 System – Standard/Network
Automation
1
2 3
4
5
6
7
8 |
1 - Automation PC
2 - Connection - PC COM1 to D6680
3 - D6680
4 - Connection - D6680 to hub
5 - Hub
6 - Second D6680
7 - Connection - D6680 to D6600 COM4
8 - D6600
*For automation packages with network capabilities: The packet format received from the D6600 is the same as for RS-232 reporting, execpt an internet protocol (IP) and user datagram protocol (UDP) header is stamped on the packet as the data transmitted by either standard IP or UDP structure over the network. Automation software can support the network communication easily by calling Socket functions, both provided in Windows and Unix. by using the built-in IP connections (or sockets) available in Windows and Unix.
1.2Direct Connection – RS-232
Figure 2 and Figure 3 show a D6600/D6100 System using any manufacturer’s automation software package directly connected to a D6600 or D6100.
Figure 2: D6600 System – Direct Connect
1
2
3 |
1 - Automation PC
2 - Connection - Automation PC COM port to
D6600 COM3
3 - |
D6600 |
|
|
|
|
|
|
|
|
|
Figure 3: |
D6100 System – Direct Connect |
|
||||||||
|
1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
2 |
|
|
|
|
|
|
|
|
|
|
3 |
|
1 |
2 |
3 |
A |
B |
|
|
|
|
|
4 |
5 |
6 |
C |
D |
|
|
|
1 |
2 |
|
7 |
8 |
9 |
E |
F |
|
|
|
|
|
POWER |
|
0 |
|
ENTER |
CANCEL |
|
|
|
|
|
|
SYSTEM |
ACKNOWLEDGE |
|
|
|
|
|
|
|
|
|
TROUBLE |
MENU |
|
FUNCTION |
||
|
|
|
|
COMMUNICATIONS RECEIVER/GATEWAY |
|
|
|
|
|
|
1 - |
Automation PC |
|
|
|
|
|
|
|
|
|
2 - Connection - Automation PC COM port to |
||||||||||
|
D6100 COM3 |
|
|
|
|
|
|
|
|
|
3 - |
D6100 |
|
|
|
|
|
|
|
|
|
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 |
7 |
Conettix D6600/D6100 | Computer Interface Manual | |
2.0 |
Making the Right Connection |
|
|
|
2.0Making the Right Connection
2.1COM3 DB9 Connector
The COM3 Port uses a standard DB9 female connector. The suggested connection to the computer is shown in Figure 4 to Figure 6.
When connecting data terminal equipment (DTE) together (such as a COM1 port to PC serial port), a null-modem cable must be used. One possible configuration for a null-modem cable is shown in
Figure 4.
Figure 4: Null Modem Cable Configuration
DTE |
DTE |
DB-9 Pin |
DB-9 Pin |
1 |
1 |
2 |
2 |
3 |
3 |
4 |
4 |
5 |
5 |
6 |
6 |
7 |
7 |
8 |
8 |
9 |
9 |
When connecting data terminal equipment to data communication equipment (DCE) (such as the D6600/D6100 COM port to a modem), a modem cable should be used (such as a straight-through cable shown in Figure 5).
Figure 5: Straight-through Modem Cable
Configuration
DTE DCE
1 8
2 3
3 2
4 20
Each pin of the modem cable is defined in Figure 6.
Figure 6: Modem Cable Pin Definitions
|
1 |
|
2 |
3 |
4 |
5 |
|
|
6 |
7 |
|
8 |
9 |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
1 - |
Data carrier detect |
|
6 - |
Data set ready |
|||
|
(DCD) |
|
|
|
(DSR) |
||
2 - |
Receive (RX) |
|
|
7 - |
Ready to send |
||
3 - |
Transmit (TX) |
|
|
|
(RTS) |
||
4 - |
Data terminal ready |
|
8 - |
Clear to send |
|||
|
(DTR) |
|
|
|
(CTS) |
||
5 - Signal-ground |
|
|
9 - |
Ring indicator (RI) |
|||
|
(SIG-GND) |
|
|
|
|
|
2.2Selecting Program Options in the D6600/D6100
Use the D6600/D6100 keypad or the D6200 Programming Software to program the receivers. Below are the recommended selections for programming when connecting the receivers to an automation system. Additional selections can be found in the D6600/D6100 Program Entry Guide
(P/N: 4998122702).
Table 1: Recommended Programming
Selections
|
|
|
|
|
|
Receiver |
|
Selects a number (01 to 99) that is |
|||
Gateway |
|
included in every message to the |
|||
Number |
|
computer in both D6500 and SIA modes |
|||
Output |
|
Enable computer output messages in the |
|
||
Format |
|
selected format: |
|
||
|
|
SIA |
|
computer interface standard |
|
|
|
|
|
||
|
|
|
|
format, recommended |
|
|
|
|
|
(expanded reporting |
|
|
|
|
|
capabilities) |
|
|
|
|
|
||
|
|
D6500 |
|
21-character format output |
|
Baud Rate |
|
Use maximum speed supported by PC |
|||
Link Test |
|
Tests if a supervision signal can be sent |
|
||
|
|
and received from the central station by |
|
||
|
|
the receiver |
|
||
|
|
|
|
|
|
5 7
6 6
7 4
8 5
9 22
8 |
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 |
Conettix D6600/D6100 | Computer Interface Manual | |
3.0 |
Computer Communication Protocols |
|
|
|
3.0Computer Communication Protocols
3.1D6500 Mode Messages
In D6500 Mode, the line number/group number sent to the computer is only one digit. Refer to Table 2.
Table 2: D6600 Line Number/Group Number Conversion Table
|
|
|
|
|
|
|
|
|
|
|
|
|
Line# |
Converted |
|
Line# |
Converted |
Line # |
Converted |
|
Line # |
|
Converted |
||
/Group # |
to |
|
/Group # |
to |
/Group # |
to |
|
/Group # |
|
to |
||
L01/G01 |
1 |
|
|
L09/G09 |
9 |
|
L17/G17 |
H |
|
L25/G25 |
|
P |
L02/G02 |
2 |
|
|
L10/G10 |
A |
L18/G18 |
I |
L26/G26 |
|
Q |
||
L03/G03 |
3 |
|
|
L11/G11 |
B |
L19/G19 |
J |
|
L27/G27 |
|
R |
|
L04/G04 |
4 |
|
|
L12/G12 |
C |
L20/G20 |
K |
|
L28/G28 |
|
S |
|
L05/G05 |
5 |
|
|
L13/G13 |
D |
|
L21/G21 |
L |
|
L29/G29 |
|
T |
L06/G06 |
6 |
|
|
L14/G14 |
E |
L22/G22 |
M |
|
L30/G30 |
|
U |
|
L07/G07 |
7 |
|
|
L15/G15 |
F |
L23/G23 |
N |
|
L31/G31 |
|
V |
|
L08/G08 |
8 |
|
|
L16/G16 |
G |
L24/G24 |
O |
|
L32/G32 |
|
W |
In D6500 mode, any group that equals 33 is converted to an “X.” Any group greater than or equal to 34 is converted to a “Y.” For lines that are grouped, Gxx appears instead of Lxx. For networked accounts, Nxx appears instead of Lxx and the line number is identified.
3.1.1Acron Super Fast (Message Type 9)
Acron Super |
D6500 Byte Description |
|
|||||||||
Fast Example |
1 |
2 |
3 |
4 |
5 |
6 7 8 9 10 |
11 12 13 14 15 16 17 |
18 19 20 |
21 22 |
|
|
|
|
h |
9 |
r |
r |
l |
s s s s a a a a C C C C C C C C t |
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
Table 3: |
Message Type 9 (Acron Super Fast) Byte Description |
|
|||||||||
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
||||
# |
Title |
|
|
|
|
Description |
|
1Header Character (h) Optional. Check with the computer automation software for compatibility.
2 |
Message Type |
9 |
3-4 |
Receiver Number |
Receiver gateway number from 01 to 99. |
|
|
|
5Line/Group Number Line number in the receiver gateway that sent the message.
6-9 |
Spaces |
Six spaces. |
10-13 |
Account Number |
Account number, four digits. |
14-21 |
Channels |
Channels 1 to 8 |
22 |
Trailer Character |
Typically, this is HEX 14. |
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 |
9 |
Conettix D6600/D6100 | Computer Interface Manual | |
3.0 |
Computer Communication Protocols |
|
|
|
3.1.2Ademco 4-1 Express (Message Type b)
4-1 Express |
|
D6500 Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
Example |
|
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
17 |
18 |
19 |
20 |
21 |
22 |
|
|
|
h b r r l s s s s s s a a a a s E s s s X t |
|
|||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
Table 4: |
Message Type b (Ademco 4-1 Express) Byte Description |
|
|
|
|
|
|
|
|
|
|
|||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
# |
Title |
|
|
|
Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1Header Character (h) Optional. Check with the computer automation software for compatibility.
2 |
Message Type |
b |
3-4 |
Receiver Number |
Receiver gateway number from 01 to 99. |
|
|
|
5Line/Group Number Line number in the receiver gateway that sent the message.
6-11 |
Spaces |
Six spaces. |
12-15 |
Account Number |
Account number, four digits. |
16 |
Space |
One space. |
17 |
E |
Event Code, “A” as the default. |
|
|
|
18-20 |
Spaces |
Three spaces. |
21 |
X |
Zone number. |
22 |
Trailer Character |
Typically, this is HEX 14. |
3.1.3Ademco 4-2 Express (Message Type c)
4-2 Express |
|
D6500 Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
Example |
|
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
17 |
18 |
19 |
20 |
21 |
22 |
|
|
|
h c r r l s s s s s s a a a a s E s s X Y t |
|
|||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
Table 5: |
Message Type c (Ademco 4-2 Express) Byte Description |
|
|
|
|
|
|
|
|
|
|
|||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
# |
Title |
|
|
|
Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1Header Character (h) Optional. Check with the computer automation software for compatibility.
2 |
Message Type |
c |
3-4 |
Receiver Number |
Receiver gateway number from 01 to 99. |
|
|
|
5Line/Group Number Line number in the receiver gateway that sent the message.
6-11 |
Spaces |
Six spaces. |
12-15 |
Account Number |
Account number, four digits. |
|
|
|
16 |
Space |
One space. |
17 |
E |
Event Code, “A” as the default. |
18-19 |
Spaces |
Two spaces. |
20-21 |
XY |
Event code and zone number. |
22 |
Trailer Character |
Typically, this is HEX 14. |
|
|
|
10 |
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 |
Conettix D6600/D6100 | Computer Interface Manual | |
3.0 |
Computer Communication Protocols |
|
|
|
3.1.4Ademco Contact-ID (Message Type a)
Contact ID |
|
D6500 Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
Example |
|
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
17 |
18 |
19 |
20 |
21 |
22 |
|
|
|
h a r r l s a a a a 1 8 Q X Y Z G G C C C t |
|
|||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
Table 6: |
Message Type a (Ademco Contact ID) Byte Description |
|
|
|
|
|
|
|
|
|
|
|||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
# |
Title |
|
|
|
Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1Header Character (h) Optional. Check with the computer automation software for compatibility.
2 |
Message Type |
a |
3-4 |
Receiver Number |
Receiver gateway number from 01 to 99. |
|
|
|
5Line/Group Number Line number in the receiver gateway that sent the message.
6 |
Space |
One space. |
7-10 |
Account Number |
Account number, four digits. |
11-12 |
18 |
Ademco Contact-ID format number |
13 |
Qualifier |
Qualifier, 1=New event or opening, 3=New restore or closing, 6=Previous event. |
|
|
|
14-16 |
XYZ |
Class code and event code (see Appendix A). |
17-18 |
GG |
Group number. |
19-21 |
CCC |
Zone codes or user ID. |
22 |
Trailer Character |
Typically, this is HEX 14. |
3.1.5Ademco High Speed, 4-8-1 (Message Type f)
SCANCOM 4-8-1, 5-8-1, 6-8-1 - Available Upon Request
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
High Speed |
|
D6500 Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
Example |
|
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
17 |
18 |
19 |
20 |
21 |
22 |
23 |
24 |
|
|||
|
|
||||||||||||||||||||||||||||
|
|
|
|
h f r r l a a a a a |
|
a s C C C C |
s C C C C s C t |
||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||
|
Table 7: |
Message Type f (Ademco High Speed, |
4-8-1) Byte Description |
|
|
|
|
|
|
|
|
|
|||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
# |
|
Title |
|
|
|
|
Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1Header Character (h) Optional. Check with the computer automation software for compatibility.
2 |
Message Type |
f |
3-4 |
Receiver Number |
Receiver gateway number from 01 to 99. |
|
|
|
5Line/Group Number Line number in the receiver gateway that sent the message.
6-11 |
Account Number |
Account number, up to six digits. |
|
|
Account number less than six characters is right aligned with leading ASCII spaces. |
12 |
Space |
One space. |
13-16 |
CCCC |
Channels 1 to 4. |
17 |
Space |
One space. |
|
|
|
18-21 |
CCCC |
Channels 5 to 8. |
22 |
Space |
One space. |
23 |
C |
Supervisory channel. |
24 |
Trailer Character |
Typically, this is HEX 14. |
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 |
11 |
Conettix D6600/D6100 | Computer Interface Manual | |
3.0 |
Computer Communication Protocols |
|
|
|
3.1.6ADT SIA (Message Type S)
ADT SIA |
|
D6500 Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
Example |
|
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
17 |
18 |
19 |
20 |
21 |
|
|
|
|
|
||||||||||||||||||||||
|
|
|
|
|||||||||||||||||||||
|
|
h |
S |
r |
r |
l |
[ |
# |
a |
a |
a |
a |
| |
d |
a |
m |
m |
- |
d |
d |
- |
y |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
22 |
23 |
24 |
25 |
26 |
27 |
28 |
29 |
30 |
31 |
32 |
33 |
34 |
35 |
36 |
37 |
38 |
39 |
40 |
41 |
42 |
|
|
|
|
y |
t |
I |
h |
h |
: |
m |
m |
: |
s |
s |
E |
M |
M |
Z |
Z |
Z |
Z |
/ ** t |
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
* |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
Table 8: |
|
ADT SIA (Message Type S) Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
# |
Title |
|
|
|
Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1Header Character (h) Optional. Check with the computer automation software for compatibility.
2 |
Message Type |
S |
3-4 |
Receiver Number |
Receiver gateway number from 01 to 99. |
|
|
|
5Line/Group Number Line number in the receiver gateway that sent the message.
6 |
|
|
space |
|
One space. |
||
7 |
|
# |
|
# |
|||
8-11 |
|
|
Account Number |
|
Up to sixteen digits in the account number. |
||
12 |
|
| |
|
|
Separator. Indicates more data positions after account number. |
||
|
|
|
|
|
|
|
|
|
13-32 |
|
|
Date and Time |
|
|
Date and time. |
33 |
|
|
E |
|
SIA block code. |
||
34-35 |
|
|
Event Code |
|
SIA event code (refer to Appendix G ADT SIA Report Codes on page 149). |
||
36-39 |
|
|
Zone |
|
Zone number. |
||
|
|
|
|
|
|
||
40 |
|
/ |
|
|
Separator. |
||
41 |
|
*** |
|
|
Next block of data. |
||
42 |
|
|
Trailer Character |
|
Typically, this is HEX 14. |
3.1.7Caller ID (Message Type e)
Caller ID |
|
D6500 Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
Example |
|
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
17 |
18 |
19 |
20 |
21 |
22 |
|
|
h e r r 1 T T T T T T T T T T T T T T T T t |
|||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||
Table 9: |
Caller ID (Message Type e) Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
# |
Title |
|
|
|
Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1Header Character (h) Optional. Check with the computer automation software for compatibility.
2 |
Message Type |
e |
3-4 |
Receiver Number |
Receiver gateway Number from 01 to 99. |
|
|
|
5Line/Group Number Line number in the receiver gateway that sent the message.
6-21 |
Caller ID |
Up to sixteen digits, Caller ID with less than sixteen characters is right aligned with |
|
|
leading ASCII spaces. |
22 |
Trailer Character |
Typically, this is HEX 14. |
12 |
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 |
Conettix D6600/D6100 | Computer Interface Manual | |
3.0 |
Computer Communication Protocols |
|
|
|
3.1.8CFSK (Message Type i)
CFSK Example |
D6500 Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
|
|
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
17 |
18 |
19 |
20 |
21 |
22 |
||
|
|
|
h i r r l s s s s a a a a a a T T E E s s t |
|||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
Table 10: CFSK (Message Type i) Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
# |
|
Title |
|
|
|
|
|
Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
||||||||||||||||||
1 |
|
Header Character (h) |
|
|
Optional. Check with the computer automation software for compatibility. |
|
|
|
||||||||||||||||||
2 |
Message Type |
|
|
|
|
i |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
3-4 |
|
Receiver Number |
|
|
|
Receiver gateway number from 01 to 99. |
|
|
|
|
|
|
|
|
|
|||||||||||
5 |
Line/Group Number |
|
|
|
Line number in the receiver gateway that sent the message. |
|
|
|
|
|
|
|||||||||||||||
6-9 |
|
Spaces |
|
|
|
|
|
Four spaces. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
10-15 |
|
Account Number |
|
|
|
Six digit account number. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
16-17 |
|
TT |
|
|
|
|
|
Event Code. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
18-19 |
|
EE |
|
|
|
|
|
Zone/User ID. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
20-21 |
|
Spaces |
|
|
|
|
|
Two spaces. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
22 |
Trailer Character |
|
|
|
Typically, this is HEX 14. |
|
|
|
|
|
|
|
|
|
|
|
|
|
3.1.9Common Formats (Message Type 1)
Type 1 Example |
D6500 Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
17 |
18 |
19 |
20 |
21 |
22 |
|
|
|
h l r r l a a a a a a a a a a E E y y y y t |
|
|||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
Table 11: Common Formats (Message Type 1) Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
# |
Title |
|
|
|
|
Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1Header Character (h) Optional. Check with the computer automation software for compatibility.
2 |
Message Type |
1 |
3-4 |
Receiver Number |
Receiver gateway number from 01 to 99. |
5 |
Line Number |
Line number in the receiver gateway that sent the message. |
|
|
|
6-15 |
Account Number |
Account number, up to ten digits. Account numbers less than ten characters are right |
|
|
aligned with leading ASCII spaces. |
16-17 |
Event Code |
Event codes define the type of signal received and interpreted by the D6500 receiver |
|
|
gateway. |
|
|
|
18-21 |
Zone Number |
Zone or ID number sent by the communicator. Zone numbers less than four digits are |
|
|
right aligned with leading ASCII spaces. |
22 |
Trailer Character |
Typically, this is HEX 14. |
The receiver gateway will sends the 3-1, 4-1, 4-2, single round, double round, extended pulse formats, BFSK, Modem II or Modem IId messages in either D6500 Mode or SIA Mode, depending on the programmable option selected. The receiver gateway also sends internal and Modem IIIa² messages in either D6500 mode or SIA mode, depending on the option selected. Refer to Appendix B: Internal Messages on page 58 and Appendix C: Modem IIIa2 Messages on page 61 for a list of the messages and their descriptions.
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 |
13 |
Conettix D6600/D6100 | Computer Interface Manual | |
3.0 |
|
|
Computer Communication Protocols |
|
|
|
|
|
|
||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3.1.10 DNIS/ANI (Message Type N) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
DNIS/ANI |
|
D6500 Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
Example |
|
1 |
|
2 |
|
3 |
|
4 |
|
5 |
|
6 |
|
7 |
|
8 |
|
9 |
|
10 |
|
11 |
|
12 |
|
13 |
|
14 |
|
15 |
|
16 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||
|
|
|
|
H |
N |
r |
r |
l |
s |
D |
d |
|
d |
d |
d |
d |
d |
d |
d |
|
|
|
||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
17 |
|
18 |
|
19 |
|
20 |
|
21 |
|
22 |
|
23 |
|
24 |
|
25 |
|
26 |
|
27 |
|
28 |
|
29 |
|
30 |
|
31 |
|
|
|
|
|
|
|
|
d |
d |
& |
|
a |
a |
a |
a |
a |
|
a |
a |
a |
a |
|
|
|
|
|
|
|
|
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||
|
|
Table 12: DNIS/ANI (Message Type N) Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
# |
Title |
|
|
|
|
Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1Header Character (H) Optional. Check with the computer automation software for compatibility.
2 |
Message Type |
N (Capital n). |
3-4 |
Receiver Number |
Receiver gateway number from 01 to 99. |
5Line/Group Number Line number in the receiver gateway that sent the message.
6 |
Space |
One space. |
7 |
DNIS Identifier |
DNIS identifier. |
|
|
|
8-18 |
DNIS Number |
DNIS number, up to 11 digits. |
19 |
ANI Identifier (&) |
ANI identifier. |
20-30 |
ANI Number |
ANI number, up to 11 digits. |
31 |
Trailer Character |
Typically, this is HEX 14. |
3.1.11 DSC 4-3 (Message Type d)
DSC 4-3 |
|
D6500 Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
Example |
|
1 |
|
2 |
|
3 |
|
4 |
|
5 |
|
6 |
|
7 |
|
8 |
|
9 |
|
10 |
|
11 |
|
12 |
|
13 |
|
14 |
|
15 |
|
16 |
|
17 |
|
18 |
|
19 |
|
20 |
|
21 |
|
22 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||
|
|
h d r r l s s s s s s a a a a s E s X Y Y t |
|||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||
Table 13: DSC-4-3 (Message Type d) Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
# |
Title |
|
|
|
|
|
|
|
|
Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1Header Character (h) Optional. Check with the computer automation software for compatibility.
2 |
Message Type |
d |
3-4 |
Receiver Number |
Receiver gateway number from 01 to 99. |
5Line/Group Number Line number in the receiver gateway that sent the message.
6-11 |
Spaces |
Six spaces. |
12-15 |
Account Number |
Account number, four digits. |
|
|
|
16 |
Space |
One space. |
17 |
E |
Event Code, “A” as the default. |
18 |
Space |
One space. |
19 |
X |
Event code number. |
|
|
|
20-21 |
YY |
Zone number. |
22 |
Trailer Character |
Typically, this is HEX 14. |
14 |
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 |
Conettix D6600/D6100 | Computer Interface Manual | |
3.0 |
Computer Communication Protocols |
|
|
|
3.1.12 FBI Super Fast (Message Type F)
FBI Super Fast |
D6500 Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
Example |
|
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
17 |
18 |
19 |
20 |
21 |
22 |
|
|
|
h F r r l s s s s s s a a a a T Z Z E s s t |
|
|||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||
Table 14: FBI Super Fast (Message Type F) Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
# |
Title |
|
|
|
|
Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1Header Character (h) Optional. Check with the computer automation software for compatibility.
2 |
Message Type |
F (Capital f). |
3-4 |
Receiver Number |
Receiver gateway number from 01 to 99. |
|
|
|
5Line/Group Number Line number in the receiver gateway that sent the message.
6-11 |
Spaces |
Six spaces. |
12-15 |
Account Number |
Account number, four digits. |
16 |
T |
Zone type. |
17-18 |
ZZ |
Zone number. |
|
|
|
19 |
E |
Event type. |
20-21 |
Spaces |
Two spaces. |
22 |
Trailer Character |
Typically, this is HEX 14. |
3.1.13 ITI (Message Type I)
ITI Example |
|
D6500 Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||
|
|
|
1 |
|
2 |
|
3 |
|
4 |
|
5 |
|
6 |
|
7 |
|
8 |
|
9 |
|
10 |
|
11 |
|
12 |
|
13 |
|
14 |
|
15 |
|
16 |
|
17 |
|
18 |
|
19 |
|
20 |
|
21 |
|
22 |
|
|
|
|
h I r r l s s s a T a a a a G I Z Z E W N t |
|||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
Table 15: ITI (Message Type I) Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
# |
|
Title |
|
|
|
|
|
|
Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
1 |
|
Header Character (h) |
|
Optional. Check with the computer automation software for compatibility. |
|
|
|
|
|
|
||||||||||||||||||||||||||||||||||||
2 |
|
Message Type |
|
|
|
|
I (Capital i). |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||
3-4 |
|
Receiver Number |
|
|
Receiver gateway number from 01 to 99. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||
5 |
|
Line/Group Number |
|
|
Line number in the receiver gateway that sent the message. |
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||||||
6-8 |
|
Spaces |
|
|
|
|
|
|
Three spaces. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
9 |
|
Account Number |
|
|
First digit account number. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
10 |
|
Panel Type |
|
|
|
|
|
|
Control panel Type. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
11-14 |
|
Account Number |
|
|
Next four digit account number. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||
15 |
|
G |
|
|
|
|
|
|
Group number. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
16 |
|
I |
|
|
|
|
|
|
Open/close (O/C) User ID. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
17-18 |
|
ZZ |
|
|
|
|
|
|
Zone number. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
19 |
|
E |
|
|
|
|
|
|
Condition code. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
20 |
|
W |
|
|
|
|
|
|
Protection level was. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
21 |
|
N |
|
|
|
|
|
|
Protection level is. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
22 |
|
Trailer Character |
|
|
Typically, this is HEX 14. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||
3.1.14 Link Test (Message Type 1) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||
Link Test |
|
D6500 Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||
Example |
|
1 |
|
2 |
|
3 |
|
4 |
|
5 |
|
6 |
|
7 |
|
8 |
|
9 |
|
10 |
|
11 |
|
12 |
|
13 |
|
14 |
|
15 |
|
16 |
|
17 |
|
18 |
|
19 |
|
20 |
|
21 |
|
22 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||
|
|
|
h 1 r r 0 s s s s s s s s s s s @ s s s s t |
|||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
The D6600/D6100 can automatically generate this message at the programmed intervals.
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 |
15 |
Conettix D6600/D6100 | Computer Interface Manual | |
3.0 |
Computer Communication Protocols |
|
|
|
Table 16: Link Test (Message Type 1) Byte Description
|
|
|
# |
Title |
Description |
1Header Character (h) Optional. Check with the computer automation software for compatibility.
2 |
Message Type |
1 |
3-4 |
Receiver Number |
Receiver gateway number from 01 to 99. |
5 |
Line Number |
Line number as zero for link test. |
6-15 |
Spaces |
Eleven spaces. |
16-17 |
Event Code |
Event code is @ for link test. |
18-21 |
Spaces |
Four spaces. |
22 |
Trailer Character |
Typically, this is HEX 14. |
3.1.15 Robofon (Message Type j)
Robofon |
|
D6500 Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
Example |
|
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
17 |
18 |
19 |
20 |
21 |
22 |
|
|
h j r r l s s s s a a a a a a E E s s s s t |
|||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||
Table 17: Robofon (Message Type j) Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
# |
Title |
|
|
|
|
Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1Header Character (h) Optional. Check with the computer automation software for compatibility.
2 |
Message Type |
j |
3-4 |
Receiver Number |
Receiver gateway number from 01 to 99. |
|
|
|
5Line/Group Number Line number in the receiver gateway that sent the message.
6-9 |
|
Spaces |
Four spaces. |
||
10-15 |
|
Account Number |
Six digit account number. |
||
|
16-17 |
|
EE |
|
Event code. |
18-21 |
|
Spaces |
Four spaces. |
||
|
|
|
|
||
22 |
|
Trailer Character |
Typically, this is HEX 14. |
16 |
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 |
Conettix D6600/D6100 | Computer Interface Manual | |
3.0 |
Computer Communication Protocols |
|
|
|
3.1.16 Sescoa Super Speed (Message Type 7)
Sescoa Super |
D6500 Byte Description |
|
||||||||||||||||
Speed Example |
1 2 3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 15 16 |
17 18 |
19 20 |
21 |
22 |
|
|
|
|
h 7 r r l s s s s s s a a a a s I A A C s t |
|
|||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||
Table 18: Sescoa Super Speed (Message Type 7) Byte Description |
|
|||||||||||||||||
|
|
|
|
|
|
|||||||||||||
|
|
|
|
|
|
|||||||||||||
# |
Title |
|
|
Description |
|
1Header Character (h) Optional. Check with the computer automation software for compatibility.
2 |
Message Type |
7 |
3-4 |
Receiver Number |
Receiver gateway number from 01 to 99. |
5Line/Group Number Line number in the receiver gateway that sent the message.
6-11 |
|
|
Spaces |
Six spaces. |
||
12-15 |
|
|
Account Number |
Account number, four digits. |
||
|
|
|
|
|
|
|
16 |
|
|
Space |
One space. |
||
17 |
|
|
I |
Event code. |
||
18-19 |
|
|
AA |
Two digit zone code or the first two digits user code. |
||
20 |
|
|
C |
Space if zone report, or the last digit user code. |
||
|
|
|
|
|
|
|
|
21 |
|
|
s |
|
One space. |
22 |
|
Trailer Character |
Typically, this is HEX 14. |
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 |
17 |
Conettix D6600/D6100 | Computer Interface Manual | |
3.0 |
|
|
|
Computer Communication Protocols |
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3.1.17 Scancom 4-16-1, 5-16-1, 6-16-1 - Available Upon Request (Message Type g) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Scancom 4-16-1, |
|
D6500 Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
5-16-1, 6-16-1 |
|
|
2 |
|
|
3 |
|
|
4 |
|
|
5 |
|
|
6 |
|
|
7 |
|
8 |
|
|
9 |
|
|
10 |
|
|
11 |
|
|
12 |
|
|
13 |
|
|
14 |
|
|
15 |
|
|
16 |
|
|
17 |
|
|
|
|
1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||
Example |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
h |
|
g |
|
r |
|
r |
|
l |
|
a |
|
a |
a |
|
a |
|
a |
|
a |
|
s |
|
C |
|
C |
|
C |
|
C |
|
s |
|
|||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||
|
18 |
19 |
|
20 |
|
21 |
|
22 |
|
23 |
|
24 |
25 |
|
26 |
|
27 |
|
28 |
|
29 |
|
30 |
|
31 |
|
32 |
|
33 |
|
34 |
|
|
|||||||||||||||||
|
|
C |
|
C |
|
C |
|
C |
|
s |
|
C |
|
C |
C |
|
C |
|
s |
|
C |
|
C |
|
C |
|
C |
|
s |
|
C |
|
t |
|
||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Table 19: Scancom 4-16-1, 5-16-1, 6-16-1 - Available Upon Request (Message Type g) Byte Description
|
|
|
# |
Title |
Description |
1Header Character (h) Optional. Check with the computer automation software for compatibility.
2 |
Message Type |
g |
3-4 |
Receiver Number |
Receiver gateway number from 01 to 99. |
|
|
|
5Line/Group Number Line number in the receiver gateway that sent the message.
|
6-11 |
|
|
Account Number |
|
Account number up to six digits. Account numbers less than six characters are right |
|
|
|
|
|
|
aligned with leading ASCII spaces. |
12 |
|
Space |
One space. |
|||
|
|
|
|
|
||
13-16 |
|
|
CCCC |
Channels 1 to 4. |
||
17 |
|
Space |
One space. |
|||
18-21 |
|
|
CCCC |
Channels 5 to 8. |
||
22 |
|
Space |
One space. |
|||
|
23-26 |
|
|
CCCC |
|
Channels 9 to 12. |
27 |
|
Space |
One space. |
|||
|
|
|
|
|
||
28-31 |
|
|
CCCC |
Channels 13 to 16. |
||
32 |
|
Space |
One space. |
|||
33 |
|
|
C |
Supervisory channel. |
||
34 |
|
Trailer Character |
Typically, this is HEX 14. |
18 |
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 |
Conettix D6600/D6100 | Computer Interface Manual | |
3.0 |
Computer Communication Protocols |
|
|
|
3.1.18 Scancom 4-24-1, 5-24-1, 6-24-1 - Available Upon Request (Message Type h)
Scancom |
D6500 Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
4-24-1 Example |
|
|
|
2 |
|
|
3 |
|
|
4 |
|
|
5 |
|
6 |
|
|
7 |
|
|
8 |
|
|
9 |
|
|
10 |
|
|
11 |
|
|
12 |
|
|
13 |
|
|
14 |
|
15 |
|
16 |
|
|
17 |
|
18 |
|
|
19 |
|
20 |
|
|
21 |
|
|
22 |
|
1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||
|
h h r r l a a a a a |
|
a |
|
s |
|
C |
|
C |
C |
C |
|
s |
C |
|
C |
C |
|
C |
|
s |
|||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||||
|
23 |
|
24 |
|
25 |
|
26 |
|
27 |
|
28 |
|
29 |
|
30 |
|
31 |
|
32 |
33 |
34 |
35 |
36 37 38 |
39 40 |
41 42 |
43 |
44 |
|
||||||||||||||||||||||||||||||||
|
C C C C s C C C C s |
|
C |
|
C |
|
C |
|
C |
s |
C |
|
C |
C |
|
C |
s |
|
C |
|
t |
|||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Table 20: Scancom 4-24-1, 5-24-1, 6-24-1 - Available Upon Request (Message Type h) Byte Description
|
|
|
# |
Title |
Description |
1Header Character (h) Optional. Check with the computer automation software for compatibility.
2 |
Message Type |
h |
3-4 |
Receiver Number |
Receiver gateway number from 01 to 99. |
|
|
|
5Line/Group Number Line number in the receiver gateway that sent the message.
|
6-11 |
|
|
Account Number |
|
Account number up to six digits. Account numbers less than six characters are right |
|
|
|
|
|
|
aligned with leading ASCII spaces. |
12 |
|
Space |
One space. |
|||
13-16 |
|
|
CCCC |
Channels 1 to 4. |
||
17 |
|
Space |
One space. |
|||
|
|
|
|
|
||
18-21 |
|
|
CCCC |
Channels 5 to 8. |
||
22 |
|
Space |
One space. |
|||
23-26 |
|
|
CCCC |
Channels 9 to 12. |
||
27 |
|
Space |
One space. |
|||
|
|
|
|
|
||
28-31 |
|
|
CCCC |
Channels 13 to 16. |
||
32 |
|
Space |
One space. |
|||
|
33-36 |
|
|
CCCC |
|
Channels 17 to 20. |
37 |
|
Space |
One space. |
|||
|
|
|
|
|
||
38-41 |
|
|
CCCC |
Channels 21 to 24. |
||
42 |
|
Space |
One space. |
|||
43 |
|
|
C |
Supervisory channel. |
||
44 |
|
Trailer Character |
Typically, this is HEX 14. |
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 |
19 |
|
Conettix D6600/D6100 | Computer Interface Manual | |
3.0 |
|
Computer Communication Protocols |
|
|
|
|
|||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3.1.19 Seriee FSK (Message Type k) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Seriee FSK |
|
D6500 Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
Example |
|
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
17 |
18 |
19 |
20 |
21 |
22 |
|
|
|
|
|
|
h k r r l s s s s s s a a a a a s E s Z Z t |
|
||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
|
|
Table 21: Seriee FSK (Message Type k) Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
# |
Title |
|
|
|
|
Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1Header Character (h) Optional. Check with the computer automation software for compatibility.
2 |
Message Type |
k |
3-4 |
Receiver Number |
Receiver gateway number from 01 to 99. |
|
|
|
5Line/Group Number Line number in the receiver gateway that sent the message.
6-11 |
Spaces |
Six spaces. |
12-16 |
Account Number |
Five digit account number. |
17 |
Space |
One space. |
18 |
E |
Event code. |
|
|
|
19 |
Space |
One space. |
20 -21 |
ZZ |
Zone number. |
22 |
Trailer Character |
Typically, HEX 14. |
3.1.20 Seriee DTMF (Message Type l)
Seriee DTMF |
D6500 Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
Example |
|
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
17 |
18 |
19 |
20 |
21 |
22 |
|
|
h l r r l L L * a a a a a a * |
|
|
. . . |
|
t |
||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||
Table 22: Seriee DTMF (Message Type l) Byte Description |
|
|
|
|
|
|
|
|
|
|
|
||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
# |
Title |
|
|
|
|
Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1Header Character (h) Optional. Check with the computer automation software for compatibility.
2 |
Message Type |
1 (lowercase L). |
3-4 |
Receiver Number |
Receiver gateway number from 01 to 99. |
|
|
|
5Line/Group Number Line number in the receiver gateway that sent the message.
6-7 |
LL |
Data length. |
8 |
* |
Data separator. |
|
|
|
9-14 |
Account number |
Four, five or six account numbers. |
15 |
* |
Data separator. |
16-21 |
*** |
DTMF Seriee Data. |
22 |
Trailer Character |
Typically, HEX 14. |
20 |
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 |
|
|
|
|
Conettix D6600/D6100 | Computer Interface Manual | |
3.0 |
|
Computer Communication Protocols |
|||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3.1.21 SIA (Message Type S) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
Defined Messages |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
SIA Example |
|
D6500 Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
1 |
2 |
|
3 |
|
4 |
5 |
6 |
|
7 |
|
8 |
9 |
10 |
11 |
12 |
|
13 |
14 |
15 |
16 |
|
17 |
18 |
19 |
20 |
21 |
22 |
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||
|
|
|
|
h |
S |
r |
r |
l |
[ |
|
# |
|
a |
a |
a |
a |
| |
|
E |
M |
M |
Z |
Z |
Z |
Z |
/ |
***] |
|
t |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
|
Table 23: SIA (Message Type S) Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
# |
|
Title |
|
|
|
|
Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
1 |
|
Header Character |
Optional. Check with the computer automation software for compatibility. |
|
|
|
|
||||||||||||||||||||||||
|
|
|
(h) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 |
|
Message Type |
|
|
S |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
3-4 |
|
Receiver Number |
Receiver gateway number from 01 to 99. |
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||
|
5 |
|
Line/Group |
|
|
Line number in the receiver gateway that sent the message. |
|
|
|
|
|
|
|
|||||||||||||||||||
|
|
|
Number |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6 |
|
[ |
|
|
|
|
|
Open bracket. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
7 |
|
# |
|
|
|
|
|
# |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||
|
8-11 |
|
Account Number |
Up to sixteen digits may be used in the account number. |
|
|
|
|
|
|
|
|
|
|||||||||||||||||||
|
12 |
|
| |
|
|
|
|
|
Separator, indicates more data positions after account number. |
|
|
|
|
|
|
|
||||||||||||||||
|
13 |
|
E |
|
|
|
|
SIA block code. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
14-15 |
|
Event Code |
|
|
SIA Event code. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
16-19 |
|
Zone |
|
|
|
|
Zone number. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
20 |
|
/ |
|
|
|
|
|
Separator. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
21 |
|
***] |
|
|
|
|
Next block of data. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
22 |
|
Trailer Character |
Typically, HEX 14. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Undefined Messages
When an SIA message contains unprintable characters (unprintable characters are out of ASCII range 0x32-0x7E) or without an account block:
SIA Example |
D6500 Byte Description |
|
|
|
|
|
|
|
|
|
|
|||||||||||||
|
|
1 |
|
2 |
|
3 |
|
4 |
|
5 |
|
|
6 |
|
7 |
|
. . . |
|
|
N-1 |
|
N |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||
|
|
h |
S |
r |
r |
|
L |
[ |
|
data |
] |
|
t |
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||
|
|
|
|
|
|
|
||||||||||||||||||
Table 24: SIA (Message Type S) Byte Description |
|
|
|
|
|
|
||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
# |
Title |
|
|
|
|
|
Description |
|
|
|
|
|
|
|
|
|
|
1Header Character Optional. Check with the computer automation software for compatibility.
(h)
2 |
Message Type |
S |
3-4 |
Receiver Number |
Receiver gateway number from 01 to 99. |
5 |
Line/Group |
Line number in the receiver gateway that sent the message. |
|
Number |
|
|
|
|
6 |
[ |
Open bracket. |
7-(N-2) |
data |
The received SIA message contains hex characters either with or without account |
|
|
portion. |
N |
Trailer Character |
Typically, HEX 14. |
|
|
|
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 |
21 |
Conettix D6600/D6100 | Computer Interface Manual | |
3.0 |
|
|
Computer Communication Protocols |
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3.1.22 Silent Knight FSK0 (Message Type 1) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
Silent Knight |
D6500 Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||
|
|
FSK0 Example |
1 |
|
2 |
|
3 |
|
4 |
|
5 |
|
6 |
|
7 |
|
8 |
|
9 |
|
10 |
|
11 |
|
12 |
|
13 |
|
14 |
|
15 |
|
16 |
|
17 |
|
18 |
|
19 |
|
20 |
|
21 |
|
22 |
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||||
|
|
|
|
h 1 r r l s s s s s s a a a a s E s s s Z t |
|
||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||
|
|
|
|
|
|||||||||||||||||||||||||||||||||||||||||||||
|
|
Table 25: Silent Knight FSK1 (Message Type m) Byte Description |
|||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||
# |
Title |
|
|
|
|
|
|
Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1Header Character Optional. Check with the computer automation software for compatibility.
(h)
2 |
Message Type |
1 |
3-4 |
Receiver Number |
Receiver gateway number from 01 to 99. |
5 |
Line/Group |
Line number in the receiver gateway that sent the message. |
|
Number |
|
6-11 |
Spaces |
Six spaces. |
12-15 |
Account Number |
Four digit account number. |
|
|
|
16 |
Spaces |
One space. |
17 |
E |
Event code. |
18-20 |
Space |
Three spaces. |
21 |
Zone number |
Zone number. |
|
|
|
22 |
Trailer Character |
Typically, HEX 14. |
Optional Silent Knight SK1 (Message Type m):
If Menu Item 2.5.16 in the D6600/D6100 Receiver is equal to 1, the following output is used.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Silent Knight |
D6500 Byte Description |
|
|
|
||||||||||||||
FSK1 Example |
1 2 3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 15 16 |
17 18 |
19 20 |
21 |
22 |
||
|
|
|
h m r r l s a a a a a a a a “ Z Z “ |
. . . |
t |
|||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||
|
Table 26: Optional Silent Knight SK1 (Message Type m) Byte Description |
|
|
|
||||||||||||||
|
|
|
|
|
|
|
||||||||||||
|
|
|
|
|
|
|
||||||||||||
# |
Title |
|
Description |
|
|
|
1Header Character Optional. Check with the computer automation software for compatibility.
(h)
2 |
|
Message Type |
m |
|||
3-4 |
|
|
Receiver Number |
Receiver gateway number from 01 to 99. |
||
5 |
|
Line/Group |
Line number in the receiver gateway that sent the message. |
|||
|
|
|
|
Number |
|
|
|
|
|
|
|
|
|
6 |
|
|
Spaces |
One space. |
||
7-14 |
|
|
Account Number |
Maximum eight-digit account code. If the account code is less than eight digits, enter the |
||
|
|
|
|
|
|
actual number of digits without a leading space. |
|
15 |
|
|
“ |
|
Separator. |
16-17 |
|
|
ZZ |
First zone number, up to eight reports, one report has two digits. |
||
|
|
|
|
|
||
18 |
|
|
“ |
Separator. |
||
19 |
|
*** |
|
More data. |
||
21 |
|
|
Trailer Character |
Typically, HEX 14. |
||
|
|
|
|
|
|
|
22 |
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 |
Conettix D6600/D6100 | Computer Interface Manual | |
3.0 |
Computer Communication Protocols |
|
|
|
Table 27: Silent Knight Automation Format
|
|
|
|
|
|
|
Report Code |
Description |
To Automation |
|
Note |
|
2 5 16=0(EEZZ) |
2 5 16=1(ZZ) |
|||
|
|
|
|
||
00: |
Alarm Panic |
PAss |
00 |
|
|
|
01 to 08: |
Alarm 01 to 08 |
sA0x |
01 to 08 |
x=1 to 8 |
09: |
Holdup |
Hass |
09 |
|
|
|
10 to 19: |
Alarm 10 to 19 |
sA1x |
10 to 19 |
x=0 to 9 |
|
20 to 29: |
Alarm Restore 10 to 19 |
sH1x |
20 to 29 |
x=0 to 9 |
30: |
Test Code |
sXss |
30 |
|
|
31: |
Trouble Line 1 |
LT01 |
31 |
|
|
32: |
Trouble Line 2 |
LT02 |
32 |
|
|
33: |
Expand Trouble |
ETss |
33 |
|
|
34: |
Forced Access |
DFss |
34 |
|
|
35: |
Restore Line 1 |
LR01 |
35 |
|
|
36: |
Restore Line 2 |
LR02 |
36 |
|
|
37: |
Expand Restore |
ERss |
37 |
|
|
38: |
Cancel Code |
OCss |
38 |
|
|
39: |
Data Lost |
RTss |
39 |
|
|
40: |
Closing |
CL00 |
40 |
|
|
|
41 to 49: |
Closing 01 to 09 |
CL0x |
41 to 49 |
x=1 to 9 |
|
50 to 59: |
Bypass 10 to 19 |
sB1x |
50 to 59 |
x=0 to 9 |
60: |
Trouble AC |
ATss |
60 |
|
|
|
61 to 68: |
Trouble 01 to 08 |
sT0x |
61 to 68 |
x=1 to 8 |
69: |
Trouble BAT |
YTss |
69 |
|
|
70: |
Restore AC |
ARss |
70 |
|
|
|
71 to 78: |
Restore 01 to 08 |
sRss |
71 to 78 |
|
79: |
Restore BAT |
YRss |
79 |
|
|
80: |
Access |
DS00 |
80 |
|
|
|
81 to 89: |
Access 01 to 09 |
DG0x |
80 to 89 |
x=1 to 9 |
90: |
Opening |
OP00 |
90 |
|
|
|
91 to 99: |
Opening 01 to 09 |
OP0x |
91 to 99 |
|
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 |
23 |
Conettix D6600/D6100 | Computer Interface Manual | |
3.0 |
Computer Communication Protocols |
|
|
|
||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3.1.23 Silent Knight FSK2 (Message Type m) |
|
|
|
|
|
|
|
|
|
||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
Silent Knight |
D6500 Byte Description |
|
|
|
|
|
|
|
|
|
|||||||||
|
|
FSK2 Example |
1 2 3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 15 16 |
17 18 |
19 20 |
21 |
22 |
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
* |
t |
|
||||||
|
|
|
|
h m r r l s a a a a a a a a “ E E Z Z “ * |
|
|
|||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
* |
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|||||||||||||||||
|
|
Table 28: Silent Knight FSK2 (Message Type m) Byte Description |
|
|
|||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
# |
Title |
|
Description |
|
|
|
|
|
|
|
|
|
1Header Character Optional. Check with the computer automation software for compatibility.
(h)
2 |
Message Type |
m |
3-4 |
Receiver Number |
Receiver gateway number from 01 to 99. |
5 |
Line/Group |
Line number in the receiver gateway that sent the message. |
|
Number |
|
6 |
Spaces |
One space. |
7-14 |
Account Number |
Maximum eight-digit account code. If the account code is less than eight digits, enter the |
|
|
actual number of digits without a leading space. |
15 |
“ |
Separator. |
16-19 |
EEZZ |
First event and zone number. If this is the only event, it will be ended with the terminator. |
|
|
Up to eight reports. One report has four digits: one-digit event code, one-digit condition |
|
|
code, two-digit zone code. |
|
|
|
20 |
“ |
Separator. |
21 |
*** |
Next data. |
22 |
Trailer Character |
Typically, HEX 14. |
3.1.24 Silent Knight FSK80 D6500 mode (Message Type E)
Silent Knight |
D6500 Byte Description |
||||||||||||||||
FSK80 Example |
1 2 3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 15 16 |
17 18 |
19 20 |
21 |
22 |
|
|
|
h E r r l s s s s s s A A A A s A s s X Y t |
|||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||
Table 29: Silent Knight FSK80 (Message Type E) Byte Description |
|||||||||||||||||
|
|
|
|
||||||||||||||
|
|
|
|
||||||||||||||
# |
Title |
|
Description |
1Header Character Optional. Check with the computer automation software for compatibility.
(h)
2 |
Message Type |
E |
3-4 |
Receiver Number |
Receiver gateway number from 01 to 99. |
5 |
Line/Group |
Line number in the receiver gateway that sent the message. |
|
Number |
|
6-11 |
Spaces |
|
12-15 |
Account Number |
Four-digit account number. |
|
|
|
16 |
Space |
|
17 |
Filler character A |
Always char “A”. |
18-19 |
Spaces |
|
20-21 |
XY |
Two-digit alarm zone code. |
|
|
|
24 |
Trailer Character |
Typically, HEX 14. |
|
|
|
24 |
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 |
Conettix D6600/D6100 | Computer Interface Manual | |
3.0 |
Computer Communication Protocols |
|
|
|
3.1.25 Telim (Message Type n)
Telim Example |
|
D6500 Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||
|
|
|
|
|
|
|
|
2 |
|
|
3 |
|
|
|
|
4 |
|
|
5 |
|
|
6 |
|
7 |
|
8 |
|
|
9 |
|
|
10 |
|
|
11 |
|
|
12 |
|
|
13 |
|
14 |
|
15 |
|
|
16 |
|
17 |
|
|
|||||
|
|
|
|
|
|
1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||
|
|
|
|
|
|
h |
|
n |
|
|
R |
|
|
R |
|
L |
|
s |
|
A |
A |
|
A |
|
|
A |
|
A |
|
A |
|
s |
E |
T |
|
T |
|
|
Z |
|
|||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
18 |
|
|
19 |
|
20 |
|
|
|
21 |
|
|
22 |
|
|
23 |
|
24 |
|
25 |
|
|
26 |
|
27 |
|
|
28 |
|
|
29 |
|
|
30 |
|
31 |
|
32 |
|
|
33 |
|
|
|
|
|
||||||
|
|
|
|
|
|
Z |
|
Z |
|
|
Z |
|
|
Z |
|
Z |
|
Z |
|
Z |
Z |
|
Z |
|
|
Z |
|
Z |
|
Z |
|
Z |
Z |
Z |
|
t |
|
|
Z |
|
|||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||
|
Table 30: Telim (Message Type n) Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
# |
|
|
Title |
|
|
|
|
|
|
|
|
|
Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||
|
1 |
|
|
Header Character |
|
|
Optional. Check with the computer automation software for compatibility. |
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||||||||||||||||||
|
|
|
|
(h) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 |
|
Message Type |
|
|
|
n |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||
3-4 |
|
|
Receiver Number |
|
|
Receiver gateway number from 01 to 99. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||||
5 |
|
Line/Group |
|
|
|
|
|
|
Line number in the receiver gateway that sent the message. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||||||||||
|
|
|
|
Number |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
6 |
|
|
Space |
|
|
|
|
|
|
One space. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||
7-12 |
|
|
Account Number |
|
|
Six digit account number. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||
|
13 |
|
|
Space |
|
|
|
|
|
|
One space. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||
14 |
|
|
E |
|
|
|
|
|
|
|
|
|
Event code. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||
15-32 |
|
|
TTZZZZZZZZZZZZ |
|
|
Input line number. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||
33 |
|
Trailer Character |
|
|
Typically, HEX 14. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||
3.1.26 Text Message (Message Type 3) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
Type 3 Example |
D6500 Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||
|
|
|
|
|
1 |
|
2 |
|
3 |
|
4 |
|
5 |
|
6 |
|
7 |
|
8 |
9 |
|
10 |
|
11 |
|
12 |
|
13 |
14 |
|
15 |
|
16 |
|
17 |
18 |
19 |
|
20 |
21 |
|
22 |
|
||||||||||||||
|
|
|
|
|
|
h 3 r r l P R I N T E R |
|
|
|
|
|
|
|
|
|
|
|
v v . v v t |
|
||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||||||||
Table 31: Text Message (Message Type 3) Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
# |
|
Title |
|
|
|
|
|
|
|
|
Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1Header Character Optional. Check with the computer automation software for compatibility.
(h)
2 |
|
Message Type |
3 |
||||
|
3-4 |
|
|
Receiver Number |
|
|
Receiver gateway number from 01 to 99. |
5 |
|
Line Number |
|
Line number fixed at 1. |
|||
6-21 |
|
|
Message Text |
|
Sixteen characters in length. |
||
22 |
|
Trailer Character |
|
Typically, HEX 14. |
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 |
25 |
Conettix D6600/D6100 | Computer Interface Manual | |
3.0 |
|
Computer Communication Protocols |
|
|
|
|
||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3.1.27 Varitech FSK 4-1 (Message Type 1) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Varitech FSK 4-1 |
D6500 Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
Example |
|
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
17 |
18 |
19 |
20 |
21 |
22 |
|
|
|
|
|
|
h 1 r r l s s s s s s a a a a s E s s s X t |
|
||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||
|
|
Table 32: Varitech FSK 4-1 (Message Type 1) Byte Description |
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
# |
Title |
|
|
|
Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1Header Character Optional. Check with the computer automation software for compatibility.
(h)
2 |
|
Message Type |
1 |
|||
3-4 |
|
Receiver Number |
Receiver gateway number from 01 to 99. |
|||
5 |
|
Line/Group |
Line number in the receiver gateway that sent the message. |
|||
|
|
|
Number |
|
||
6-11 |
|
Spaces |
Six spaces. |
|||
12-15 |
|
Account Number |
Four digit account number. |
|||
16 |
|
Space |
One space. |
|||
17 |
|
E |
Event code. |
|||
|
18-20 |
|
|
Spaces |
|
Three spaces. |
21 |
|
X |
Zone number. |
|||
22 |
|
Trailer Character |
Typically, HEX 14. |
|||
|
|
|
|
|
|
|
3.1.28 Varitech FSK 4-2 (Message Type 1)
Varitech FSK 4-2 |
D6500 Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
Example |
1 |
2 |
3 |
4 |
5 |
|
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
17 |
18 |
19 |
20 |
21 |
22 |
|
|
|
|||||||||||||||||||||||
|
h 1 r r l s s s s s s a a a a s E s s X Y t |
|||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Table 33: Varitech FSK 4-2 (Message Type 1) Byte Description
# |
Title |
Description |
1 |
Header |
Optional. Check with the computer automation software for compatibility. |
|
Character (h) |
|
2 |
Message Type |
1 |
3-4 |
Receiver Number |
Receiver gateway number from 01 to 99. |
5 |
Line/Group |
Line number in the receiver gateway that sent the message. |
|
Number |
|
6-11 |
Spaces |
Six spaces. |
12-15 |
Account Number |
Four digit account number. |
16 |
Space |
One space. |
17 |
E |
Event code. |
18-19 |
Spaces |
Two spaces. |
20-21 |
XY |
Zone number. |
22 |
Trailer Character |
Typically, HEX 14. |
26 |
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 |
Conettix D6600/D6100 | Computer Interface Manual | |
3.0 |
Computer Communication Protocols |
|
|
|
3.1.29 VONK (Message Type V)
|
|
D6500 Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
VONK Example |
1 |
|
|
2 |
|
3 |
|
4 |
|
5 |
|
6 |
|
|
7 |
|
|
8 |
|
|
9 |
|
|
|
10 |
|
11 |
|
|
12 |
|
|
13 |
|
14 |
|
15 |
|
16 |
|
17 |
|
18 |
|
19 |
|
20 |
|
|
21 |
|
|
22 |
|
|
23 |
|
24 |
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||||||
|
|
h V r r l A A 1 2 3 4 5 6 7 8 9 A B C D E F G t |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||
Table 34: VONK (Message Type V) Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
# |
Title |
|
|
|
|
|
|
|
Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||
1 |
Header Character |
|
Optional. Check with the computer automation software for compatibility. |
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||
|
(h) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 |
Message Type |
|
|
V |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
3-4 |
Receiver Number |
|
Receiver gateway number from 01 to 99. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||||||||||
5 |
Line/Group |
|
|
Line number in the receiver gateway that sent the message. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
|
Number |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||
6-7 |
Account Number |
|
Two digit account number. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||
8-23 |
Zone status |
|
|
Status of zones 1 to 16. If the zone is Closed, a “.”(Period) is in this position. If the zone is |
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
Open, 1 to G appears in this position. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||
24 |
Trailer Character |
|
Typically, HEX 14 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||
3.1.30 X-SIA Text (Message Type S) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
X-SIA Example |
D6500 Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||
|
|
1 |
2 |
3 |
4 |
|
5 |
|
|
6 |
|
7 |
|
8 |
|
9 |
|
10 |
|
11 |
12 |
13 |
|
14 |
15 |
16 |
17 |
18 |
|
19 |
|
20 |
|
21 |
|
22 |
|
|||||||||||||||||||||||||||
|
|
h S r r l [ # a a a a | E M M Z Z Z Z * ` T |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||
|
|
23 |
|
24 |
25 |
26 |
|
|
27 |
|
28 |
|
29 |
|
30 |
|
|
31 |
|
32 |
|
|
33 |
|
34 |
35 |
|
36 |
|
37 |
|
38 |
39 |
40 |
|
41 |
|
42 |
|
|
|
|
|
|
||||||||||||||||||||
|
|
T T T T T T T T T T T T ‘ N M / * * * t |
|
|
|
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||||||||||
Table 35: X-SIA Text (Message Type S) Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
# |
Title |
|
|
|
|
|
|
|
Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1Header Character Optional. Check with the computer automation software for compatibility.
(h)
2 |
|
Message Type |
|
S |
|||
|
3-4 |
|
|
Receiver Number |
|
|
Receiver gateway number from 01 to 99. |
5 |
|
Line/Group |
|
Line number in the receiver gateway that sent the message. |
|||
|
|
|
|
Number |
|
|
|
6 |
|
[ |
|
|
Open bracket. |
||
7 |
|
# |
|
# |
|||
|
|
|
|
|
|
||
8-11 |
|
|
Account Number |
|
Use up to sixteen digits in the account number. |
||
12 |
|
| |
|
|
Separator. Indicates more data positions after account number. |
||
13 |
|
|
E |
|
SIA block code. |
||
14-15 |
|
|
MM |
|
SIA event code. |
||
|
|
|
|
|
|
||
16-19 |
|
|
ZZZZ |
|
Zone number. |
||
20 |
|
* |
|
|
Text identifier. |
||
21 |
|
|
‘ |
|
Quotation mark (single). |
||
22-34 |
|
TT…T |
|
13 character text string. |
|||
|
35 |
|
|
‘ |
|
|
Qutotation mark (single). |
36-37 |
|
|
NM |
|
Unit field characters. |
||
|
|
|
|
|
|
||
38 |
|
/ |
|
|
Separator. |
||
39-41 |
|
*** |
|
|
Next block of data. |
||
42 |
|
|
Trailer Character |
|
Typically, HEX 14. |
||
|
|
|
|
|
|
|
|
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 |
27 |
|
Conettix D6600/D6100 | Computer Interface Manual | |
3.0 |
|
|
Computer Communication Protocols |
|
|
|
|
|
||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3.1.31 SafeCom (Message Type p) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
SafeCom Example |
D6500 Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
2 |
|
3 |
|
4 |
|
5 |
|
6 |
|
7 |
|
8 |
|
9 |
|
10 |
|
11 |
|
12 |
|
13 |
|
14 |
|
... |
|
N-1 |
|
N |
|
|
|
|
|
|
|
1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||
|
|
|
|
h |
p |
r |
|
r |
l |
A |
A |
A |
A |
E |
E |
E |
E |
. . . data . . . |
t |
|
||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||
|
|
Table 36: SafeCom (Message Type p) Byte Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
# |
Title |
|
|
|
Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1Header Character (h) Optional. Check with the computer automation software for compatibility.
2 |
Message Type |
p |
3-4 |
Receiver Number |
Receiver gateway number from 01 to 99. |
5Line Card Number Line number in the receiver gateway that sent the message.
6-9 |
Account Number |
Four digits. |
10-13 |
Event Code |
Four digits. |
14-(N-1) |
Data |
Parameter data for event code. |
N |
Trailer Character |
Typically, HEX 14. |
3.2SIA Mode Messages
Use the SIA mode for central station monitoring.
3.2.1Acron Super Fast (Message Type 9)
Acron Super Fast SIA Mode Description
Example <LF><CRC><9><sequence#><receiver#><line#>[#aaaa|CCCCCCCC]<CR>
Table 37: Acron Super Fast (Message Type 9) Byte Description
|
|
Title |
Description |
L |
Standard line feed character. |
CRC |
Cyclical redundancy check number. |
Message Type |
9 |
sequence# |
The message sequence number. The valid sequence number range is 0001 to 9999. |
|
|
receiver# |
The receiver gateway that sent the message. Valid digits are 01 to 99 for the |
|
D6600/D6100. |
line# |
The line number of the line in the receiver gateway that sent the message. Valid digits are 00 |
(Line/Group #) |
to 99. The receiver uses Line 0 (zero) for internal messages. |
account# |
The communicator's account number has four digits. |
Figure 7: Message sent to printer
mm/ddshh:mmsLxxsACNsACCTsaaaa+++sACCsa aaasCCCCsCCCC
For lines that are grouped, Gxx appears instead of Lxx.
Table 38: Acron Super Fast (Message Type 9)
|
Printer Output |
|
|
|
|
|
|
|
Characters |
|
Description |
ACN |
|
Acron Super Fast format. |
Lxx |
|
Line number. |
Gxx |
|
Grouped line numbers. |
28 |
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 |
Conettix D6600/D6100 | Computer Interface Manual | |
3.0 |
Computer Communication Protocols |
|
|
|
3.2.2Ademco Contact-ID (Message Type a)
Contact-ID |
SIA Mode Description |
|
||||
Example |
<LF><CRC><a><sequence#><receiver#><line#>[#aaaa|18QXYZGGCCC]<CR> |
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Table 39: Ademco Contact-ID (Message Type a) Byte Description |
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Title |
|
|
|
Description |
|
|
LF |
|
|
|
Standard line feed character. |
|
|
CRC |
|
|
|
Cyclical redundancy check number. |
|
|
Message Type |
|
|
|
a |
|
|
sequence# |
|
|
|
The message sequence number. The valid sequence number range is 0001 to 9999. |
|
|
|
|
|
|
|
|
|
receiver# |
|
|
|
The receiver gateway that sent the message. Valid digits are 01 to 99 for the |
|
|
|
|
|
|
D6600/D6100. |
|
|
line# |
|
|
|
The line number of the line in the receiver gateway that sent the message. Valid digits are 00 |
|
|
(Line/Group #) |
|
|
|
to 99. The receiver uses Line 0 (zero) for internal messages. |
|
|
|
|
|
|
|
|
|
account# |
|
|
|
The communicator's account number has four digits. |
|
18 |
|
|
|
Ademco Contact-ID format number. |
|
|
|
Q |
|
|
|
Qualifier, 1 = New event or opening, 3 = New restore or closing, 6 = Previous event. |
|
|
XYZ |
|
|
|
Class code and event code (refer to Appendix A: Contact ID Event Code Classifications on |
|
|
|
|
|
|
page 53). |
|
|
GG |
|
|
|
Group number. |
|
|
CCC |
|
|
|
Zone codes or User ID. |
|
Figure 8: Message sent to printer
mm/ddshh:mmsLxxsCIDsACCTsaaaa+++sACCsa
aaasNNNsEVENT=XYZsG=GGsC=CCC
For lines that are grouped, Gxx appears instead of Lxx.
Table 40: Ademco Contact-ID (Message Type a)
|
|
Printer Output |
||
|
|
|
|
|
|
|
|
|
|
|
Characters |
|
Description |
|
|
|
|
|
|
|
CID |
|
Contact-ID format. |
|
|
Gxx |
|
Grouped Line numbers. |
|
|
Lxx |
|
Line number. |
|
|
NNN |
|
If Q = 1, print E/O for new event or |
|
|
|
|
opening If Q = 3, print R/C for restore or |
|
|
|
|
closing If Q = 6, print “OLD” for old |
|
|
|
|
messages and events. |
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 |
29 |
Conettix D6600/D6100 | Computer Interface Manual | |
3.0 |
Computer Communication Protocols |
|
|
|
3.2.3Ademco 4-1 Express (Message Type b)
4-1 Express |
SIA Mode Description |
|
||||
Example |
<LF><CRC><b><sequence#><receiver#><line#>[#aaaa|X]<CR> |
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Table 41: Ademco 4-1 Express (Message Type b) Byte Description |
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Title |
|
|
|
Description |
|
|
|
|
|
|
|
|
|
LF |
|
|
|
Standard line feed character. |
|
|
CRC |
|
|
|
Cyclical redundancy check number. |
|
|
Message Type |
|
|
|
b |
|
|
sequence# |
|
|
|
The message sequence number. The valid sequence number range is 0001 to 9999. |
|
|
receiver# |
|
|
|
The receiver gateway that sent the message. Valid digits are 01 to 99 for the |
|
|
|
|
|
|
D6600/D6100. |
|
|
line# |
|
|
|
The line number of the line in the receiver gateway that sent the message. Valid digits are 00 |
|
|
(Line/Group #) |
|
|
|
to 99. The receiver uses Line 0 (zero) for internal messages. |
|
|
|
|
|
|
|
|
|
account# |
|
|
|
The communicator's account number has four digits. |
|
|
X |
|
|
|
Zone number |
|
Figure 9: Message sent to printer
mm/ddshh:mmsLxxsE41sACCTsaaaasEVENT=X
For lines that are grouped, Gxx appears instead of Lxx.
Table 42: Ademco 4-1 Express (Message
|
Type b) Printer Output |
|
|
|
|
|
|
|
Characters |
|
Description |
|
|
|
E41 |
|
Ademco 4-1 Express format. |
Lxx: |
|
Line number. |
Gxx |
|
Grouped line numbers. |
30 |
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 |