Contents

1.0

System Connection ..........................................

7

1.1Conettix D6680 Ethernet Network Adapter

 

Connection ..........................................................

7

1.2

Direct Connection – RS-232 .............................

7

2.0

Making the Right Connection .......................

8

2.1

COM3 DB9 Connector .....................................

8

2.2Selecting Program Options in the

 

D6600/D6100 .....................................................

8

3.0

Computer Communication Protocols..........

9

3.1

D6500 Mode Messages ......................................

9

3.1.1

Acron Super Fast (Message Type 9).................

9

3.1.2

Ademco 4-1

Express (Message Type b).........

10

3.1.3

Ademco 4-2

Express (Message Type c) .........

10

3.1.4

Ademco Contact-ID (Message Type a)..........

11

3.1.5Ademco High Speed, 4-8-1 (Message Type f)

 

............................................................................

11

3.1.6

ADT SIA (Message Type S) ............................

12

3.1.7

Caller ID (Message Type e).............................

12

3.1.8

CFSK (Message Type i) ...................................

13

3.1.9

Common Formats (Message Type 1) .............

13

3.1.10

DNIS/ANI (Message Type N) ........................

14

3.1.11

DSC 4-3 (Message Type d)..............................

14

3.1.12

FBI Super Fast (Message Type F) ...................

15

3.1.13

ITI (Message Type I)........................................

15

3.1.14

Link Test (Message Type 1) ............................

15

3.1.15

Robofon (Message Type j)...............................

16

3.1.16

Sescoa Super Speed (Message Type 7) ..........

17

3.1.17Scancom 4-16-1, 5-16-1, 6-16-1 - Available

Upon Request (Message Type g) ....................

18

3.1.18Scancom 4-24-1, 5-24-1, 6-24-1 - Available

Upon Request (Message Type h)....................

19

3.1.19 Seriee FSK (Message Type k)..........................

20

3.1.20 Seriee DTMF (Message Type l) ......................

20

3.1.21 SIA (Message Type S) ......................................

21

3.1.22 Silent Knight FSK0 (Message Type 1) ...........

22

3.1.23 Silent Knight FSK2 (Message Type m) ..........

24

3.1.24Silent Knight FSK80 D6500 mode (Message

Type E) ..............................................................

24

3.1.25 Telim (Message Type n) ..................................

25

3.1.26 Text Message (Message Type 3) .....................

25

3.1.27 Varitech FSK 4-1 (Message Type 1)...............

26

3.1.28 Varitech FSK 4-2 (Message Type 1)...............

26

3.1.29 VONK (Message Type V)...............................

27

3.1.30 X-SIA Text (Message Type S).........................

27

3.1.31 SafeCom (Message Type p).............................

28

3.2

SIA Mode Messages ........................................

28

3.2.1

Acron Super Fast (Message Type 9) ..............

28

3.2.2

Ademco Contact-ID (Message Type a) .........

29

3.2.3

Ademco 4-1

Express (Message Type b) ........

30

3.2.4

Ademco 4-2

Express (Message Type c).........

31

3.2.5Ademco High Speed 4-8-1, SCANCOM 4-8-1

 

(Message Type f) ..............................................

32

3.2.6 ADT SIA (Message Type <TAB>) ................

33

3.2.7

Caller ID (Message Type <TAB>) ................

33

3.2.8

CFSK (Message Type I) ..................................

34

3.2.9Common Formats (Message Type <TAB>) . 34

3.2.10 DNIS/ANI (Message Type N)........................

35

3.2.11 DSC 4-3 (Message Type d) .............................

36

3.2.12 FBI Super Fast (Message Type F) ..................

37

3.2.13 ITI (Message Type I) .......................................

38

3.2.14 Link Test (Message Type <TAB>) ................

38

3.2.15 RB2000 (Message Type R) Description ........

39

3.2.16 Robofon (Message Type j) ..............................

40

3.2.17Scancom 4-16-1, 5-16-1, 6-16-1 - Available

Upon Request (Message Type g) ...................

40

3.2.18Scancom 4-24-1, 5-24-1, 6-24-1 - Available

 

Upon Request (Message Type h) ...................

41

3.2.19 Seriee DTMF (Message Type l)......................

42

3.2.20

Seriee FSK (Message Type k) .........................

42

3.2.21

Sescoa Super Speed (Message Type 7)..........

43

3.2.22Silent Knight FSK() (Message Type <TAB>) 44

3.2.23 Silent Knight FSK1 (Message Type m)..........

44

3.2.24 Silent Knight FSK2 (Message Type m)..........

46

3.2.25

Silent Knight FSK80 (Message Type E) ........

47

3.2.26

Telim (Message Type n)..................................

48

3.2.27Varitech FSK 4-1 (Message Type <TAB>) . 48

3.2.28

Varitech FSK 4-2 (Message Type <TAB>)

... 49

3.2.29

VONK (Message Type V) ..............................

49

3.2.30

X-SIA text (Message Type <TAB>) ..............

50

3.2.31

SafeCom (Message Type p) ............................

51

3.3

Input Command Processing ...........................

52

Appendix A: Contact ID Event Code

 

 

Classifications .................................................

53

Appendix B: Internal Messages................................

58

Appendix C: Modem IIIa2 Messages .......................

61

C.1

Zonex and Comex Translation ....................

137

Appendix D: Network Messages (D6600 Only) ..

138

Appendix E: Pulse Output .......................................

141

Appendix F: Format ID (by Message Type) – D6600

 

Only ................................................................

146

Bosch Security Systems, Inc. | 1/07 | 4998122703-01

3

Conettix D6600/D6100 | Computer Interface Manual | Contents

Appendix G: ADT SIA Report Codes ...................

149

Appendix H: D6600 RB2000 Messages ..................

151

Appendix I: D6600 SafeCom Messages .................

158

Figures

 

 

Figure 1:

D6600 System – Standard/Network

 

 

Automation ..................................................

7

Figure 2:

D6600 System – Direct Connect ...............

7

Figure 3:

D6100 System – Direct Connect ...............

7

Figure 4:

Null Modem Cable Configuration ............

8

Figure 5:

Straight-through Modem Cable

 

 

Configuration ...............................................

8

Figure 6:

Modem Cable Pin Definitions ...................

8

Figure 7:

Message sent to printer .............................

28

Figure 8:

Message sent to printer .............................

29

Figure 9:

Message sent to printer .............................

30

Figure 10:

Message sent to printer .............................

31

Figure 11:

Message sent to printer .............................

32

Figure 12:

Message sent to printer .............................

34

Figure 13:

Message sent to printer .............................

35

Figure 14:

Message sent to printer .............................

35

Figure 15:

Message sent to printer .............................

36

Figure 16:

Message sent to printer .............................

37

Figure 17:

Single message sent to Printer..................

39

Figure 18:

Multiple messages sent to printer ............

39

Figure 19:

Message sent to printer .............................

41

Figure 20:

Message sent to printer .............................

41

Figure 21:

Message sent to printer .............................

43

Figure 22:

Message sent to printer .............................

47

Figure 23:

Message sent to printer .............................

50

Figure 24:

Contact ID format .....................................

53

Figure 25:

D6200 Receiver Software Line Card

 

 

Configuration ...........................................

141

Tables

 

 

Table 1:

Recommended Programming Selections.. 8

Table 2:

D6600 Line Number/Group Number

 

 

Conversion Table ........................................

9

Table 3:

Message Type 9 (Acron Super Fast) Byte

 

Description ...................................................

9

Table 4:

Message Type b (Ademco 4-1 Express)

 

 

Byte Description ........................................

10

Table 5:

Message Type c (Ademco 4-2 Express)

 

 

Byte Description ........................................

10

Table 6:

Message Type a (Ademco Contact ID)

 

 

Byte Description ........................................

11

Table 7:

Message Type f (Ademco High Speed, 4-8-

 

1) Byte Description....................................

11

Table 8:

ADT SIA (Message Type S) Byte

 

 

Description ................................................

12

Table 9:

Caller ID (Message Type e) Byte

 

 

Description ................................................

12

Table 10:

CFSK (Message Type i) Byte Description

 

....................................................................

13

Table 11:

Common Formats (Message Type 1) Byte

 

Description ................................................

13

Table 12:

DNIS/ANI (Message Type N) Byte

 

 

Description ................................................

14

Table 13:

DSC-4-3 (Message Type d) Byte

 

 

Description ................................................

14

Table 14:

FBI Super Fast (Message Type F) Byte

 

 

Description ................................................

15

Table 15:

ITI (Message Type I) Byte Description.. 15

Table 16:

Link Test (Message Type 1) Byte

 

 

Description ................................................

16

Table 17:

Robofon (Message Type j) Byte

 

 

Description ................................................

16

Table 18:

Sescoa Super Speed (Message Type 7)

 

 

Byte Description........................................

17

Table 19:

Scancom 4-16-1, 5-16-1, 6-16-1 - Available

 

Upon Request (Message Type g) Byte

 

 

Description ................................................

18

Table 20:

Scancom 4-24-1, 5-24-1, 6-24-1 - Available

 

Upon Request (Message Type h) Byte

 

 

Description ................................................

19

Table 21:

Seriee FSK (Message Type k) Byte

 

 

Description ................................................

20

Table 22:

Seriee DTMF (Message Type l) Byte

 

 

Description ................................................

20

Table 23:

SIA (Message Type S) Byte Description 21

Table 24:

SIA (Message Type S) Byte Description. 21

Table 25:

Silent Knight FSK1 (Message Type m)

 

 

Byte Description........................................

22

Table 26:

Optional Silent Knight SK1 (Message

 

 

Type m) Byte Description........................

22

Table 27:

Silent Knight Automation Format ..........

23

Table 28:

Silent Knight FSK2 (Message Type m)

 

 

Byte Description........................................

24

Table 29:

Silent Knight FSK80 (Message Type E)

 

 

Byte Description........................................

24

Table 30:

Telim (Message Type n) Byte Description

 

....................................................................

25

Table 31:

Text Message (Message Type 3) Byte

 

 

Description ................................................

25

Table 32:

Varitech FSK 4-1 (Message Type 1) Byte

 

Description ................................................

26

Table 33:

Varitech FSK 4-2 (Message Type 1) Byte

 

Description ................................................

26

4

Bosch Security Systems, Inc. | 1/07 | 4998122703-01

Conettix D6600/D6100 | Computer Interface Manual | Contents

Table 34: VONK (Message Type V) Byte

 

 

Description .................................................

27

Table 35: X-SIA Text (Message Type S) Byte

 

 

Description .................................................

27

Table 36: SafeCom (Message Type p) Byte

 

 

Description .................................................

28

Table 37: Acron Super Fast (Message Type 9) Byte

 

Description .................................................

28

Table 38: Acron Super Fast (Message Type 9)

 

 

Printer Output............................................

28

Table 39: Ademco Contact-ID (Message Type a)

 

 

Byte Description ........................................

29

Table 40: Ademco Contact-ID (Message Type a)

 

 

Printer Output............................................

29

Table 41: Ademco 4-1 Express (Message Type b)

 

 

Byte Description ........................................

30

Table 42: Ademco 4-1 Express (Message Type b)

 

 

Printer Output............................................

30

Table 43: Ademco 4-2 Express (Message Type c)

 

 

Byte Description ........................................

31

Table 44: Ademco 4-2 Express (Message Type c)

 

 

Printer Output............................................

31

Table 45: Ademco High Speed 4-8-1, SCANCOM 4-

 

8-1 (Message Type F) Byte Description ..32

Table 46: Ademco High Speed, 4-8-1 (Message Type

 

f) Printer Output ........................................

32

Table 47: ADT SIA (Message Type <TAB>) Byte

 

 

Description .................................................

33

Table 48: Caller ID (Message Type <TAB>) Byte

 

 

Description .................................................

33

Table 49:

CFSK (Message Type I) Byte Description

 

.....................................................................

34

Table 50: Common Formats (Message Type

 

 

<TAB>) Byte Description ........................

34

Table 51: Common Formats (Message Type <TAB>)

 

Byte Description ........................................

35

Table 52: DNIS/ANI (Message Type N) Byte

 

 

Description .................................................

35

Table 53: DSC 4-3 (Message Type d) Byte

 

 

Description .................................................

36

Table 54:

DSC 4-3 (Message Type d) Printer Output

 

.....................................................................

36

Table 55: Event Code Table .....................................

36

Table 56: Printer Output Codes................................

36

Table 57: FBI Super Fast (Message Type F) Byte

 

 

Description .................................................

37

Table 58:

FBI Super Fast (Message Type F) Printer

 

Output.........................................................

37

Table 59: Event Code Table .....................................

37

Table 60:

Printer Output Codes................................

37

Table 61: ITI (Message Type I) Byte Description..

38

Table 62: Link Test (Message Type <TAB>)

 

 

Description ................................................

38

Table 63: RB2000 (Message Type R) Byte

 

 

Description ................................................

39

Table 64:

RB2000 (Message Type R) Printer Output

 

....................................................................

39

Table 65: Robofon (Message Type j) Byte

 

 

Description ................................................

40

Table 66: Scancom 4-16-1, 5-16-1, 6-16-1 - Available

 

Upon Request (Message Type g) Byte

 

 

Description ................................................

40

Table 67: Scancom 4-16-1, 5-16-1, 6-16-1 - Available

 

Upon Request (Message Type g) Printer

 

 

Output ........................................................

41

Table 68: Scancom 4-24-1, 5-24-1, 6-24-1 - Available

 

Upon Request (Message Type h) Byte

 

 

Description ................................................

41

Table 69: Scancom 4-24-1, 5-24-1, 6-24-1 - Available

 

Upon Request (Message Type h) Printer

 

 

Output ........................................................

41

Table 70: Seriee DTMF (Message Type l) Byte

 

 

Description ................................................

42

Table 71: Seriee FSK (Message Type k) Byte

 

 

Description ................................................

42

Table 72: Sescoa Super Speed (Message Type 7)

 

 

Byte Description........................................

43

Table 73: Sescoa Super Speed (Message Type 7)

 

 

Printer Output ...........................................

43

Table 74: Silent Knight FSK0 (Message Type

 

 

<TAB>) Byte Description........................

44

Table 75: Silent Knight FSK1 (Message Type m)

 

 

Byte Description........................................

44

Table 76: Optional Silent Knight FSK1 (Message

 

 

Type m) Byte Description........................

45

Table 77: Silent Knight FSK1 Optional Outputs....

45

Table 78: Silent Knight FSK2 (Message Type m)

 

 

Byte Description........................................

46

Table 79: Silent Knight FSK80 (Message Type E)

 

 

Byte Description........................................

47

Table 80:

Silent Knight FSK80 Printer/LCD output

 

....................................................................

47

Table 81:

Telim (Message Type n) Byte Description

 

....................................................................

48

Table 82:

Varitech FSK 4-1 (Message Type <TAB>)

 

Byte Description........................................

48

Table 83: Varitech FSK 4-2 (Message Type <TAB>)

 

Byte Description........................................

49

Table 84: VONK (Message Type V) Byte

 

 

Description ................................................

49

Bosch Security Systems, Inc. | 1/07 | 4998122703-01

5

Conettix D6600/D6100 | Computer Interface Manual | Contents

Table 85:

X-SIA text (Message Type <TAB>) Byte

 

Description .................................................

50

Table 86:

X-SIA Printer/LCD output ......................

50

Table 87:

SafeCom (Message Type p) Byte

 

 

Description .................................................

51

Table 88:

ASCII Text Message to Automation Port

 

.....................................................................

52

Table 89:

Input Command Output Messages .........

52

Table 90:

Event Codes ...............................................

53

Table 91:

Internal Messages ......................................

58

Table 92:

Modem IIIa2 Messages .............................

61

Table 93:

Point to Zonex Translation.....................

137

Table 94:

User ID to Comex Translation ..............

137

Table 95:

Reported Zone/ID to Actual Point/ID .137

Table 96:

Network Messages...................................

138

Table 97:

Pulse 3/1 Format .....................................

141

Table 98:

Pulse 3/1E Menu 3.1.3.12 3-1 Extended

 

Format = 1 ...............................................

142

Table 99:

Pulse 3/1E Menu 3.1.3.12 3-1 Extended

 

Format = 2 ...............................................

142

Table 100:

Pulse 3/2 ...................................................

143

Table 101:

Pulse 4/1 ...................................................

143

Table 102:

Pulse 4/1E Menu 3.1.3.3 4/1 Extended = 1

 

...................................................................

144

Table 103:

Pulse 4/1E Menu 3.1.3.3 4/1 Extended = 2

 

...................................................................

144

Table 104:

Pulse 4/2 ...................................................

145

Table 105:

Pulse 4/3 ...................................................

145

Table 106:

Generic Byte Description .......................

146

Table 107:

Generic SIA Byte Description ...............

146

Table 108:

Message Examples ..................................

147

Table 109:

ADT SIA Report Codes .........................

149

Table 110:

D6600 RB2000 Messages .......................

151

Table 111:

D6600 Virtual Line Conversion Table .158

Table 112:

D6600 SafeCom Messages - Line Card or

 

Account Signals .......................................

159

Table 113:

D6600 SafeCom Messages - Intercepted

 

Control Panel Signals..............................

162

Table 114:

Explanation of Automation Output Items

 

(within Message Body only) ...................

164

Table 115:

Explanation of Printer Output Items ....

165

Table 116:

Supported Event Codes ..........................

166

6

Bosch Security Systems, Inc. | 1/07 | 4998122703-01

Bosch D6100, D6600 User Manual

Conettix D6600/D6100 | Computer Interface Manual |

1.0

System Connection

 

 

 

1.0System Connection

1.1Conettix D6680 Ethernet Network

Adapter Connection

Use the Conettix D6680 Ethernet Network Adapter to connect a manufacturer’s automation software package to the D6600 when the software cannot receive network data (Figure 1). Refer to the Special Conettix D6600 Applications in the Conettix D6600 System Guide

(P/N: 4998122712).

Figure 1: D6600 System – Standard/Network

Automation

1

2 3

4

5

6

7

8

1 - Automation PC

2 - Connection - PC COM1 to D6680

3 - D6680

4 - Connection - D6680 to hub

5 - Hub

6 - Second D6680

7 - Connection - D6680 to D6600 COM4

8 - D6600

*For automation packages with network capabilities: The packet format received from the D6600 is the same as for RS-232 reporting, execpt an internet protocol (IP) and user datagram protocol (UDP) header is stamped on the packet as the data transmitted by either standard IP or UDP structure over the network. Automation software can support the network communication easily by calling Socket functions, both provided in Windows and Unix. by using the built-in IP connections (or sockets) available in Windows and Unix.

1.2Direct Connection – RS-232

Figure 2 and Figure 3 show a D6600/D6100 System using any manufacturer’s automation software package directly connected to a D6600 or D6100.

Figure 2: D6600 System – Direct Connect

1

2

3

1 - Automation PC

2 - Connection - Automation PC COM port to

D6600 COM3

3 -

D6600

 

 

 

 

 

 

 

 

 

Figure 3:

D6100 System – Direct Connect

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

3

 

1

2

3

A

B

 

 

 

 

 

4

5

6

C

D

 

 

1

2

 

7

8

9

E

F

 

 

 

 

POWER

 

0

 

ENTER

CANCEL

 

 

 

 

 

SYSTEM

ACKNOWLEDGE

 

 

 

 

 

 

 

 

TROUBLE

MENU

 

FUNCTION

 

 

 

 

COMMUNICATIONS RECEIVER/GATEWAY

 

 

 

 

 

 

1 -

Automation PC

 

 

 

 

 

 

 

 

2 - Connection - Automation PC COM port to

 

D6100 COM3

 

 

 

 

 

 

 

 

3 -

D6100

 

 

 

 

 

 

 

 

 

Bosch Security Systems, Inc. | 1/07 | 4998122703-01

7

Conettix D6600/D6100 | Computer Interface Manual |

2.0

Making the Right Connection

 

 

 

2.0Making the Right Connection

2.1COM3 DB9 Connector

The COM3 Port uses a standard DB9 female connector. The suggested connection to the computer is shown in Figure 4 to Figure 6.

When connecting data terminal equipment (DTE) together (such as a COM1 port to PC serial port), a null-modem cable must be used. One possible configuration for a null-modem cable is shown in

Figure 4.

Figure 4: Null Modem Cable Configuration

DTE

DTE

DB-9 Pin

DB-9 Pin

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

9

9

When connecting data terminal equipment to data communication equipment (DCE) (such as the D6600/D6100 COM port to a modem), a modem cable should be used (such as a straight-through cable shown in Figure 5).

Figure 5: Straight-through Modem Cable

Configuration

DTE DCE

1 8

2 3

3 2

4 20

Each pin of the modem cable is defined in Figure 6.

Figure 6: Modem Cable Pin Definitions

 

1

 

2

3

4

5

 

6

7

 

8

9

 

 

 

 

 

 

 

 

 

 

 

 

1 -

Data carrier detect

 

6 -

Data set ready

 

(DCD)

 

 

 

(DSR)

2 -

Receive (RX)

 

 

7 -

Ready to send

3 -

Transmit (TX)

 

 

 

(RTS)

4 -

Data terminal ready

 

8 -

Clear to send

 

(DTR)

 

 

 

(CTS)

5 - Signal-ground

 

 

9 -

Ring indicator (RI)

 

(SIG-GND)

 

 

 

 

 

2.2Selecting Program Options in the D6600/D6100

Use the D6600/D6100 keypad or the D6200 Programming Software to program the receivers. Below are the recommended selections for programming when connecting the receivers to an automation system. Additional selections can be found in the D6600/D6100 Program Entry Guide

(P/N: 4998122702).

Table 1: Recommended Programming

Selections

 

 

 

 

 

 

Receiver

 

Selects a number (01 to 99) that is

Gateway

 

included in every message to the

Number

 

computer in both D6500 and SIA modes

Output

 

Enable computer output messages in the

 

Format

 

selected format:

 

 

 

SIA

 

computer interface standard

 

 

 

 

 

 

 

 

 

format, recommended

 

 

 

 

 

(expanded reporting

 

 

 

 

 

capabilities)

 

 

 

 

 

 

 

D6500

 

21-character format output

 

Baud Rate

 

Use maximum speed supported by PC

Link Test

 

Tests if a supervision signal can be sent

 

 

 

and received from the central station by

 

 

 

the receiver

 

 

 

 

 

 

 

5 7

6 6

7 4

8 5

9 22

8

Bosch Security Systems, Inc. | 1/07 | 4998122703-01

Conettix D6600/D6100 | Computer Interface Manual |

3.0

Computer Communication Protocols

 

 

 

3.0Computer Communication Protocols

3.1D6500 Mode Messages

In D6500 Mode, the line number/group number sent to the computer is only one digit. Refer to Table 2.

Table 2: D6600 Line Number/Group Number Conversion Table

 

 

 

 

 

 

 

 

 

 

 

 

 

Line#

Converted

 

Line#

Converted

Line #

Converted

 

Line #

 

Converted

/Group #

to

 

/Group #

to

/Group #

to

 

/Group #

 

to

L01/G01

1

 

 

L09/G09

9

 

L17/G17

H

 

L25/G25

 

P

L02/G02

2

 

 

L10/G10

A

L18/G18

I

L26/G26

 

Q

L03/G03

3

 

 

L11/G11

B

L19/G19

J

 

L27/G27

 

R

L04/G04

4

 

 

L12/G12

C

L20/G20

K

 

L28/G28

 

S

L05/G05

5

 

 

L13/G13

D

 

L21/G21

L

 

L29/G29

 

T

L06/G06

6

 

 

L14/G14

E

L22/G22

M

 

L30/G30

 

U

L07/G07

7

 

 

L15/G15

F

L23/G23

N

 

L31/G31

 

V

L08/G08

8

 

 

L16/G16

G

L24/G24

O

 

L32/G32

 

W

In D6500 mode, any group that equals 33 is converted to an “X.” Any group greater than or equal to 34 is converted to a “Y.” For lines that are grouped, Gxx appears instead of Lxx. For networked accounts, Nxx appears instead of Lxx and the line number is identified.

3.1.1Acron Super Fast (Message Type 9)

Acron Super

D6500 Byte Description

 

Fast Example

1

2

3

4

5

6 7 8 9 10

11 12 13 14 15 16 17

18 19 20

21 22

 

 

 

h

9

r

r

l

s s s s a a a a C C C C C C C C t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 3:

Message Type 9 (Acron Super Fast) Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#

Title

 

 

 

 

Description

 

1Header Character (h) Optional. Check with the computer automation software for compatibility.

2

Message Type

9

3-4

Receiver Number

Receiver gateway number from 01 to 99.

 

 

 

5Line/Group Number Line number in the receiver gateway that sent the message.

6-9

Spaces

Six spaces.

10-13

Account Number

Account number, four digits.

14-21

Channels

Channels 1 to 8

22

Trailer Character

Typically, this is HEX 14.

Bosch Security Systems, Inc. | 1/07 | 4998122703-01

9

Conettix D6600/D6100 | Computer Interface Manual |

3.0

Computer Communication Protocols

 

 

 

3.1.2Ademco 4-1 Express (Message Type b)

4-1 Express

 

D6500 Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example

 

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

 

 

 

h b r r l s s s s s s a a a a s E s s s X t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 4:

Message Type b (Ademco 4-1 Express) Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#

Title

 

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1Header Character (h) Optional. Check with the computer automation software for compatibility.

2

Message Type

b

3-4

Receiver Number

Receiver gateway number from 01 to 99.

 

 

 

5Line/Group Number Line number in the receiver gateway that sent the message.

6-11

Spaces

Six spaces.

12-15

Account Number

Account number, four digits.

16

Space

One space.

17

E

Event Code, “A” as the default.

 

 

 

18-20

Spaces

Three spaces.

21

X

Zone number.

22

Trailer Character

Typically, this is HEX 14.

3.1.3Ademco 4-2 Express (Message Type c)

4-2 Express

 

D6500 Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example

 

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

 

 

 

h c r r l s s s s s s a a a a s E s s X Y t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 5:

Message Type c (Ademco 4-2 Express) Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#

Title

 

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1Header Character (h) Optional. Check with the computer automation software for compatibility.

2

Message Type

c

3-4

Receiver Number

Receiver gateway number from 01 to 99.

 

 

 

5Line/Group Number Line number in the receiver gateway that sent the message.

6-11

Spaces

Six spaces.

12-15

Account Number

Account number, four digits.

 

 

 

16

Space

One space.

17

E

Event Code, “A” as the default.

18-19

Spaces

Two spaces.

20-21

XY

Event code and zone number.

22

Trailer Character

Typically, this is HEX 14.

 

 

 

10

Bosch Security Systems, Inc. | 1/07 | 4998122703-01

Conettix D6600/D6100 | Computer Interface Manual |

3.0

Computer Communication Protocols

 

 

 

3.1.4Ademco Contact-ID (Message Type a)

Contact ID

 

D6500 Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example

 

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

 

 

 

h a r r l s a a a a 1 8 Q X Y Z G G C C C t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 6:

Message Type a (Ademco Contact ID) Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#

Title

 

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1Header Character (h) Optional. Check with the computer automation software for compatibility.

2

Message Type

a

3-4

Receiver Number

Receiver gateway number from 01 to 99.

 

 

 

5Line/Group Number Line number in the receiver gateway that sent the message.

6

Space

One space.

7-10

Account Number

Account number, four digits.

11-12

18

Ademco Contact-ID format number

13

Qualifier

Qualifier, 1=New event or opening, 3=New restore or closing, 6=Previous event.

 

 

 

14-16

XYZ

Class code and event code (see Appendix A).

17-18

GG

Group number.

19-21

CCC

Zone codes or user ID.

22

Trailer Character

Typically, this is HEX 14.

3.1.5Ademco High Speed, 4-8-1 (Message Type f)

SCANCOM 4-8-1, 5-8-1, 6-8-1 - Available Upon Request

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High Speed

 

D6500 Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example

 

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

 

 

 

 

 

 

 

h f r r l a a a a a

 

a s C C C C

s C C C C s C t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 7:

Message Type f (Ademco High Speed,

4-8-1) Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#

 

Title

 

 

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1Header Character (h) Optional. Check with the computer automation software for compatibility.

2

Message Type

f

3-4

Receiver Number

Receiver gateway number from 01 to 99.

 

 

 

5Line/Group Number Line number in the receiver gateway that sent the message.

6-11

Account Number

Account number, up to six digits.

 

 

Account number less than six characters is right aligned with leading ASCII spaces.

12

Space

One space.

13-16

CCCC

Channels 1 to 4.

17

Space

One space.

 

 

 

18-21

CCCC

Channels 5 to 8.

22

Space

One space.

23

C

Supervisory channel.

24

Trailer Character

Typically, this is HEX 14.

Bosch Security Systems, Inc. | 1/07 | 4998122703-01

11

Conettix D6600/D6100 | Computer Interface Manual |

3.0

Computer Communication Protocols

 

 

 

3.1.6ADT SIA (Message Type S)

ADT SIA

 

D6500 Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example

 

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

 

 

 

 

 

 

 

 

 

 

 

h

S

r

r

l

[

#

a

a

a

a

|

d

a

m

m

-

d

d

-

y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

 

 

 

 

y

t

I

h

h

:

m

m

:

s

s

E

M

M

Z

Z

Z

Z

/ ** t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 8:

 

ADT SIA (Message Type S) Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#

Title

 

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1Header Character (h) Optional. Check with the computer automation software for compatibility.

2

Message Type

S

3-4

Receiver Number

Receiver gateway number from 01 to 99.

 

 

 

5Line/Group Number Line number in the receiver gateway that sent the message.

6

 

 

space

 

One space.

7

 

#

 

#

8-11

 

 

Account Number

 

Up to sixteen digits in the account number.

12

 

|

 

 

Separator. Indicates more data positions after account number.

 

 

 

 

 

 

 

 

 

13-32

 

 

Date and Time

 

 

Date and time.

33

 

 

E

 

SIA block code.

34-35

 

 

Event Code

 

SIA event code (refer to Appendix G ADT SIA Report Codes on page 149).

36-39

 

 

Zone

 

Zone number.

 

 

 

 

 

 

40

 

/

 

 

Separator.

41

 

***

 

 

Next block of data.

42

 

 

Trailer Character

 

Typically, this is HEX 14.

3.1.7Caller ID (Message Type e)

Caller ID

 

D6500 Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example

 

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

 

 

h e r r 1 T T T T T T T T T T T T T T T T t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 9:

Caller ID (Message Type e) Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#

Title

 

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1Header Character (h) Optional. Check with the computer automation software for compatibility.

2

Message Type

e

3-4

Receiver Number

Receiver gateway Number from 01 to 99.

 

 

 

5Line/Group Number Line number in the receiver gateway that sent the message.

6-21

Caller ID

Up to sixteen digits, Caller ID with less than sixteen characters is right aligned with

 

 

leading ASCII spaces.

22

Trailer Character

Typically, this is HEX 14.

12

Bosch Security Systems, Inc. | 1/07 | 4998122703-01

Conettix D6600/D6100 | Computer Interface Manual |

3.0

Computer Communication Protocols

 

 

 

3.1.8CFSK (Message Type i)

CFSK Example

D6500 Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

 

 

 

h i r r l s s s s a a a a a a T T E E s s t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 10: CFSK (Message Type i) Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#

 

Title

 

 

 

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

Header Character (h)

 

 

Optional. Check with the computer automation software for compatibility.

 

 

 

2

Message Type

 

 

 

 

i

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3-4

 

Receiver Number

 

 

 

Receiver gateway number from 01 to 99.

 

 

 

 

 

 

 

 

 

5

Line/Group Number

 

 

 

Line number in the receiver gateway that sent the message.

 

 

 

 

 

 

6-9

 

Spaces

 

 

 

 

 

Four spaces.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10-15

 

Account Number

 

 

 

Six digit account number.

 

 

 

 

 

 

 

 

 

 

 

 

 

16-17

 

TT

 

 

 

 

 

Event Code.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18-19

 

EE

 

 

 

 

 

Zone/User ID.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20-21

 

Spaces

 

 

 

 

 

Two spaces.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22

Trailer Character

 

 

 

Typically, this is HEX 14.

 

 

 

 

 

 

 

 

 

 

 

 

 

3.1.9Common Formats (Message Type 1)

Type 1 Example

D6500 Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

 

 

 

h l r r l a a a a a a a a a a E E y y y y t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 11: Common Formats (Message Type 1) Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#

Title

 

 

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1Header Character (h) Optional. Check with the computer automation software for compatibility.

2

Message Type

1

3-4

Receiver Number

Receiver gateway number from 01 to 99.

5

Line Number

Line number in the receiver gateway that sent the message.

 

 

 

6-15

Account Number

Account number, up to ten digits. Account numbers less than ten characters are right

 

 

aligned with leading ASCII spaces.

16-17

Event Code

Event codes define the type of signal received and interpreted by the D6500 receiver

 

 

gateway.

 

 

 

18-21

Zone Number

Zone or ID number sent by the communicator. Zone numbers less than four digits are

 

 

right aligned with leading ASCII spaces.

22

Trailer Character

Typically, this is HEX 14.

The receiver gateway will sends the 3-1, 4-1, 4-2, single round, double round, extended pulse formats, BFSK, Modem II or Modem IId messages in either D6500 Mode or SIA Mode, depending on the programmable option selected. The receiver gateway also sends internal and Modem IIIa² messages in either D6500 mode or SIA mode, depending on the option selected. Refer to Appendix B: Internal Messages on page 58 and Appendix C: Modem IIIa2 Messages on page 61 for a list of the messages and their descriptions.

Bosch Security Systems, Inc. | 1/07 | 4998122703-01

13

Conettix D6600/D6100 | Computer Interface Manual |

3.0

 

 

Computer Communication Protocols

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.1.10 DNIS/ANI (Message Type N)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DNIS/ANI

 

D6500 Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example

 

1

 

2

 

3

 

4

 

5

 

6

 

7

 

8

 

9

 

10

 

11

 

12

 

13

 

14

 

15

 

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

N

r

r

l

s

D

d

 

d

d

d

d

d

d

d

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17

 

18

 

19

 

20

 

21

 

22

 

23

 

24

 

25

 

26

 

27

 

28

 

29

 

30

 

31

 

 

 

 

 

 

 

 

d

d

&

 

a

a

a

a

a

 

a

a

a

a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 12: DNIS/ANI (Message Type N) Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#

Title

 

 

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1Header Character (H) Optional. Check with the computer automation software for compatibility.

2

Message Type

N (Capital n).

3-4

Receiver Number

Receiver gateway number from 01 to 99.

5Line/Group Number Line number in the receiver gateway that sent the message.

6

Space

One space.

7

DNIS Identifier

DNIS identifier.

 

 

 

8-18

DNIS Number

DNIS number, up to 11 digits.

19

ANI Identifier (&)

ANI identifier.

20-30

ANI Number

ANI number, up to 11 digits.

31

Trailer Character

Typically, this is HEX 14.

3.1.11 DSC 4-3 (Message Type d)

DSC 4-3

 

D6500 Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example

 

1

 

2

 

3

 

4

 

5

 

6

 

7

 

8

 

9

 

10

 

11

 

12

 

13

 

14

 

15

 

16

 

17

 

18

 

19

 

20

 

21

 

22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

h d r r l s s s s s s a a a a s E s X Y Y t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 13: DSC-4-3 (Message Type d) Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#

Title

 

 

 

 

 

 

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1Header Character (h) Optional. Check with the computer automation software for compatibility.

2

Message Type

d

3-4

Receiver Number

Receiver gateway number from 01 to 99.

5Line/Group Number Line number in the receiver gateway that sent the message.

6-11

Spaces

Six spaces.

12-15

Account Number

Account number, four digits.

 

 

 

16

Space

One space.

17

E

Event Code, “A” as the default.

18

Space

One space.

19

X

Event code number.

 

 

 

20-21

YY

Zone number.

22

Trailer Character

Typically, this is HEX 14.

14

Bosch Security Systems, Inc. | 1/07 | 4998122703-01

Conettix D6600/D6100 | Computer Interface Manual |

3.0

Computer Communication Protocols

 

 

 

3.1.12 FBI Super Fast (Message Type F)

FBI Super Fast

D6500 Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example

 

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

 

 

 

h F r r l s s s s s s a a a a T Z Z E s s t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 14: FBI Super Fast (Message Type F) Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#

Title

 

 

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1Header Character (h) Optional. Check with the computer automation software for compatibility.

2

Message Type

F (Capital f).

3-4

Receiver Number

Receiver gateway number from 01 to 99.

 

 

 

5Line/Group Number Line number in the receiver gateway that sent the message.

6-11

Spaces

Six spaces.

12-15

Account Number

Account number, four digits.

16

T

Zone type.

17-18

ZZ

Zone number.

 

 

 

19

E

Event type.

20-21

Spaces

Two spaces.

22

Trailer Character

Typically, this is HEX 14.

3.1.13 ITI (Message Type I)

ITI Example

 

D6500 Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

2

 

3

 

4

 

5

 

6

 

7

 

8

 

9

 

10

 

11

 

12

 

13

 

14

 

15

 

16

 

17

 

18

 

19

 

20

 

21

 

22

 

 

 

 

h I r r l s s s a T a a a a G I Z Z E W N t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 15: ITI (Message Type I) Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#

 

Title

 

 

 

 

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

Header Character (h)

 

Optional. Check with the computer automation software for compatibility.

 

 

 

 

 

 

2

 

Message Type

 

 

 

 

I (Capital i).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3-4

 

Receiver Number

 

 

Receiver gateway number from 01 to 99.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

Line/Group Number

 

 

Line number in the receiver gateway that sent the message.

 

 

 

 

 

 

 

 

 

 

 

 

6-8

 

Spaces

 

 

 

 

 

 

Three spaces.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

Account Number

 

 

First digit account number.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

Panel Type

 

 

 

 

 

 

Control panel Type.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11-14

 

Account Number

 

 

Next four digit account number.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

G

 

 

 

 

 

 

Group number.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

 

I

 

 

 

 

 

 

Open/close (O/C) User ID.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17-18

 

ZZ

 

 

 

 

 

 

Zone number.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

19

 

E

 

 

 

 

 

 

Condition code.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

W

 

 

 

 

 

 

Protection level was.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

21

 

N

 

 

 

 

 

 

Protection level is.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22

 

Trailer Character

 

 

Typically, this is HEX 14.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.1.14 Link Test (Message Type 1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Link Test

 

D6500 Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example

 

1

 

2

 

3

 

4

 

5

 

6

 

7

 

8

 

9

 

10

 

11

 

12

 

13

 

14

 

15

 

16

 

17

 

18

 

19

 

20

 

21

 

22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

h 1 r r 0 s s s s s s s s s s s @ s s s s t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The D6600/D6100 can automatically generate this message at the programmed intervals.

Bosch Security Systems, Inc. | 1/07 | 4998122703-01

15

Conettix D6600/D6100 | Computer Interface Manual |

3.0

Computer Communication Protocols

 

 

 

Table 16: Link Test (Message Type 1) Byte Description

 

 

 

#

Title

Description

1Header Character (h) Optional. Check with the computer automation software for compatibility.

2

Message Type

1

3-4

Receiver Number

Receiver gateway number from 01 to 99.

5

Line Number

Line number as zero for link test.

6-15

Spaces

Eleven spaces.

16-17

Event Code

Event code is @ for link test.

18-21

Spaces

Four spaces.

22

Trailer Character

Typically, this is HEX 14.

3.1.15 Robofon (Message Type j)

Robofon

 

D6500 Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example

 

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

 

 

h j r r l s s s s a a a a a a E E s s s s t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 17: Robofon (Message Type j) Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#

Title

 

 

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1Header Character (h) Optional. Check with the computer automation software for compatibility.

2

Message Type

j

3-4

Receiver Number

Receiver gateway number from 01 to 99.

 

 

 

5Line/Group Number Line number in the receiver gateway that sent the message.

6-9

 

Spaces

Four spaces.

10-15

 

Account Number

Six digit account number.

 

16-17

 

EE

 

Event code.

18-21

 

Spaces

Four spaces.

 

 

 

 

22

 

Trailer Character

Typically, this is HEX 14.

16

Bosch Security Systems, Inc. | 1/07 | 4998122703-01

Conettix D6600/D6100 | Computer Interface Manual |

3.0

Computer Communication Protocols

 

 

 

3.1.16 Sescoa Super Speed (Message Type 7)

Sescoa Super

D6500 Byte Description

 

Speed Example

1 2 3

4

5

6

7

8

9

10

11

12

13

14 15 16

17 18

19 20

21

22

 

 

 

h 7 r r l s s s s s s a a a a s I A A C s t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 18: Sescoa Super Speed (Message Type 7) Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

#

Title

 

 

Description

 

1Header Character (h) Optional. Check with the computer automation software for compatibility.

2

Message Type

7

3-4

Receiver Number

Receiver gateway number from 01 to 99.

5Line/Group Number Line number in the receiver gateway that sent the message.

6-11

 

 

Spaces

Six spaces.

12-15

 

 

Account Number

Account number, four digits.

 

 

 

 

 

 

 

16

 

 

Space

One space.

17

 

 

I

Event code.

18-19

 

 

AA

Two digit zone code or the first two digits user code.

20

 

 

C

Space if zone report, or the last digit user code.

 

 

 

 

 

 

 

 

21

 

 

s

 

One space.

22

 

Trailer Character

Typically, this is HEX 14.

Bosch Security Systems, Inc. | 1/07 | 4998122703-01

17

Conettix D6600/D6100 | Computer Interface Manual |

3.0

 

 

 

Computer Communication Protocols

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.1.17 Scancom 4-16-1, 5-16-1, 6-16-1 - Available Upon Request (Message Type g)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Scancom 4-16-1,

 

D6500 Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5-16-1, 6-16-1

 

 

2

 

 

3

 

 

4

 

 

5

 

 

6

 

 

7

 

8

 

 

9

 

 

10

 

 

11

 

 

12

 

 

13

 

 

14

 

 

15

 

 

16

 

 

17

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

h

 

g

 

r

 

r

 

l

 

a

 

a

a

 

a

 

a

 

a

 

s

 

C

 

C

 

C

 

C

 

s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

19

 

20

 

21

 

22

 

23

 

24

25

 

26

 

27

 

28

 

29

 

30

 

31

 

32

 

33

 

34

 

 

 

 

C

 

C

 

C

 

C

 

s

 

C

 

C

C

 

C

 

s

 

C

 

C

 

C

 

C

 

s

 

C

 

t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 19: Scancom 4-16-1, 5-16-1, 6-16-1 - Available Upon Request (Message Type g) Byte Description

 

 

 

#

Title

Description

1Header Character (h) Optional. Check with the computer automation software for compatibility.

2

Message Type

g

3-4

Receiver Number

Receiver gateway number from 01 to 99.

 

 

 

5Line/Group Number Line number in the receiver gateway that sent the message.

 

6-11

 

 

Account Number

 

Account number up to six digits. Account numbers less than six characters are right

 

 

 

 

 

 

aligned with leading ASCII spaces.

12

 

Space

One space.

 

 

 

 

 

13-16

 

 

CCCC

Channels 1 to 4.

17

 

Space

One space.

18-21

 

 

CCCC

Channels 5 to 8.

22

 

Space

One space.

 

23-26

 

 

CCCC

 

Channels 9 to 12.

27

 

Space

One space.

 

 

 

 

 

28-31

 

 

CCCC

Channels 13 to 16.

32

 

Space

One space.

33

 

 

C

Supervisory channel.

34

 

Trailer Character

Typically, this is HEX 14.

18

Bosch Security Systems, Inc. | 1/07 | 4998122703-01

Conettix D6600/D6100 | Computer Interface Manual |

3.0

Computer Communication Protocols

 

 

 

3.1.18 Scancom 4-24-1, 5-24-1, 6-24-1 - Available Upon Request (Message Type h)

Scancom

D6500 Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4-24-1 Example

 

 

 

2

 

 

3

 

 

4

 

 

5

 

6

 

 

7

 

 

8

 

 

9

 

 

10

 

 

11

 

 

12

 

 

13

 

 

14

 

15

 

16

 

 

17

 

18

 

 

19

 

20

 

 

21

 

 

22

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

h h r r l a a a a a

 

a

 

s

 

C

 

C

C

C

 

s

C

 

C

C

 

C

 

s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

23

 

24

 

25

 

26

 

27

 

28

 

29

 

30

 

31

 

32

33

34

35

36 37 38

39 40

41 42

43

44

 

 

C C C C s C C C C s

 

C

 

C

 

C

 

C

s

C

 

C

C

 

C

s

 

C

 

t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 20: Scancom 4-24-1, 5-24-1, 6-24-1 - Available Upon Request (Message Type h) Byte Description

 

 

 

#

Title

Description

1Header Character (h) Optional. Check with the computer automation software for compatibility.

2

Message Type

h

3-4

Receiver Number

Receiver gateway number from 01 to 99.

 

 

 

5Line/Group Number Line number in the receiver gateway that sent the message.

 

6-11

 

 

Account Number

 

Account number up to six digits. Account numbers less than six characters are right

 

 

 

 

 

 

aligned with leading ASCII spaces.

12

 

Space

One space.

13-16

 

 

CCCC

Channels 1 to 4.

17

 

Space

One space.

 

 

 

 

 

18-21

 

 

CCCC

Channels 5 to 8.

22

 

Space

One space.

23-26

 

 

CCCC

Channels 9 to 12.

27

 

Space

One space.

 

 

 

 

 

28-31

 

 

CCCC

Channels 13 to 16.

32

 

Space

One space.

 

33-36

 

 

CCCC

 

Channels 17 to 20.

37

 

Space

One space.

 

 

 

 

 

38-41

 

 

CCCC

Channels 21 to 24.

42

 

Space

One space.

43

 

 

C

Supervisory channel.

44

 

Trailer Character

Typically, this is HEX 14.

Bosch Security Systems, Inc. | 1/07 | 4998122703-01

19

 

Conettix D6600/D6100 | Computer Interface Manual |

3.0

 

Computer Communication Protocols

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.1.19 Seriee FSK (Message Type k)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Seriee FSK

 

D6500 Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example

 

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

 

 

 

 

 

h k r r l s s s s s s a a a a a s E s Z Z t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 21: Seriee FSK (Message Type k) Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#

Title

 

 

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1Header Character (h) Optional. Check with the computer automation software for compatibility.

2

Message Type

k

3-4

Receiver Number

Receiver gateway number from 01 to 99.

 

 

 

5Line/Group Number Line number in the receiver gateway that sent the message.

6-11

Spaces

Six spaces.

12-16

Account Number

Five digit account number.

17

Space

One space.

18

E

Event code.

 

 

 

19

Space

One space.

20 -21

ZZ

Zone number.

22

Trailer Character

Typically, HEX 14.

3.1.20 Seriee DTMF (Message Type l)

Seriee DTMF

D6500 Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example

 

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

 

 

h l r r l L L * a a a a a a *

 

 

. . .

 

t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 22: Seriee DTMF (Message Type l) Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#

Title

 

 

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1Header Character (h) Optional. Check with the computer automation software for compatibility.

2

Message Type

1 (lowercase L).

3-4

Receiver Number

Receiver gateway number from 01 to 99.

 

 

 

5Line/Group Number Line number in the receiver gateway that sent the message.

6-7

LL

Data length.

8

*

Data separator.

 

 

 

9-14

Account number

Four, five or six account numbers.

15

*

Data separator.

16-21

***

DTMF Seriee Data.

22

Trailer Character

Typically, HEX 14.

20

Bosch Security Systems, Inc. | 1/07 | 4998122703-01

 

 

 

 

Conettix D6600/D6100 | Computer Interface Manual |

3.0

 

Computer Communication Protocols

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.1.21 SIA (Message Type S)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Defined Messages

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIA Example

 

D6500 Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

 

3

 

4

5

6

 

7

 

8

9

10

11

12

 

13

14

15

16

 

17

18

19

20

21

22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

h

S

r

r

l

[

 

#

 

a

a

a

a

|

 

E

M

M

Z

Z

Z

Z

/

***]

 

t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 23: SIA (Message Type S) Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#

 

Title

 

 

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

Header Character

Optional. Check with the computer automation software for compatibility.

 

 

 

 

 

 

 

(h)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

Message Type

 

 

S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3-4

 

Receiver Number

Receiver gateway number from 01 to 99.

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

Line/Group

 

 

Line number in the receiver gateway that sent the message.

 

 

 

 

 

 

 

 

 

 

Number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

[

 

 

 

 

 

Open bracket.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

#

 

 

 

 

 

#

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8-11

 

Account Number

Up to sixteen digits may be used in the account number.

 

 

 

 

 

 

 

 

 

 

12

 

|

 

 

 

 

 

Separator, indicates more data positions after account number.

 

 

 

 

 

 

 

 

13

 

E

 

 

 

 

SIA block code.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14-15

 

Event Code

 

 

SIA Event code.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16-19

 

Zone

 

 

 

 

Zone number.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

/

 

 

 

 

 

Separator.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

21

 

***]

 

 

 

 

Next block of data.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22

 

Trailer Character

Typically, HEX 14.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Undefined Messages

When an SIA message contains unprintable characters (unprintable characters are out of ASCII range 0x32-0x7E) or without an account block:

SIA Example

D6500 Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

1

 

2

 

3

 

4

 

5

 

 

6

 

7

 

. . .

 

 

N-1

 

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

h

S

r

r

 

L

[

 

data

]

 

t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 24: SIA (Message Type S) Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#

Title

 

 

 

 

 

Description

 

 

 

 

 

 

 

 

 

 

1Header Character Optional. Check with the computer automation software for compatibility.

(h)

2

Message Type

S

3-4

Receiver Number

Receiver gateway number from 01 to 99.

5

Line/Group

Line number in the receiver gateway that sent the message.

 

Number

 

 

 

 

6

[

Open bracket.

7-(N-2)

data

The received SIA message contains hex characters either with or without account

 

 

portion.

N

Trailer Character

Typically, HEX 14.

 

 

 

Bosch Security Systems, Inc. | 1/07 | 4998122703-01

21

Conettix D6600/D6100 | Computer Interface Manual |

3.0

 

 

Computer Communication Protocols

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.1.22 Silent Knight FSK0 (Message Type 1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Silent Knight

D6500 Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FSK0 Example

1

 

2

 

3

 

4

 

5

 

6

 

7

 

8

 

9

 

10

 

11

 

12

 

13

 

14

 

15

 

16

 

17

 

18

 

19

 

20

 

21

 

22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

h 1 r r l s s s s s s a a a a s E s s s Z t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 25: Silent Knight FSK1 (Message Type m) Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#

Title

 

 

 

 

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1Header Character Optional. Check with the computer automation software for compatibility.

(h)

2

Message Type

1

3-4

Receiver Number

Receiver gateway number from 01 to 99.

5

Line/Group

Line number in the receiver gateway that sent the message.

 

Number

 

6-11

Spaces

Six spaces.

12-15

Account Number

Four digit account number.

 

 

 

16

Spaces

One space.

17

E

Event code.

18-20

Space

Three spaces.

21

Zone number

Zone number.

 

 

 

22

Trailer Character

Typically, HEX 14.

Optional Silent Knight SK1 (Message Type m):

If Menu Item 2.5.16 in the D6600/D6100 Receiver is equal to 1, the following output is used.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Silent Knight

D6500 Byte Description

 

 

 

FSK1 Example

1 2 3

4

5

6

7

8

9

10

11

12

13

14 15 16

17 18

19 20

21

22

 

 

 

h m r r l s a a a a a a a a “ Z Z “

. . .

t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 26: Optional Silent Knight SK1 (Message Type m) Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#

Title

 

Description

 

 

 

1Header Character Optional. Check with the computer automation software for compatibility.

(h)

2

 

Message Type

m

3-4

 

 

Receiver Number

Receiver gateway number from 01 to 99.

5

 

Line/Group

Line number in the receiver gateway that sent the message.

 

 

 

 

Number

 

 

 

 

 

 

 

 

6

 

 

Spaces

One space.

7-14

 

 

Account Number

Maximum eight-digit account code. If the account code is less than eight digits, enter the

 

 

 

 

 

 

actual number of digits without a leading space.

 

15

 

 

 

Separator.

16-17

 

 

ZZ

First zone number, up to eight reports, one report has two digits.

 

 

 

 

 

18

 

 

Separator.

19

 

***

 

More data.

21

 

 

Trailer Character

Typically, HEX 14.

 

 

 

 

 

 

 

22

Bosch Security Systems, Inc. | 1/07 | 4998122703-01

Conettix D6600/D6100 | Computer Interface Manual |

3.0

Computer Communication Protocols

 

 

 

Table 27: Silent Knight Automation Format

 

 

 

 

 

 

 

Report Code

Description

To Automation

 

Note

 

2 5 16=0(EEZZ)

2 5 16=1(ZZ)

 

 

 

 

00:

Alarm Panic

PAss

00

 

 

01 to 08:

Alarm 01 to 08

sA0x

01 to 08

x=1 to 8

09:

Holdup

Hass

09

 

 

10 to 19:

Alarm 10 to 19

sA1x

10 to 19

x=0 to 9

 

20 to 29:

Alarm Restore 10 to 19

sH1x

20 to 29

x=0 to 9

30:

Test Code

sXss

30

 

31:

Trouble Line 1

LT01

31

 

32:

Trouble Line 2

LT02

32

 

33:

Expand Trouble

ETss

33

 

34:

Forced Access

DFss

34

 

35:

Restore Line 1

LR01

35

 

36:

Restore Line 2

LR02

36

 

37:

Expand Restore

ERss

37

 

38:

Cancel Code

OCss

38

 

39:

Data Lost

RTss

39

 

40:

Closing

CL00

40

 

 

41 to 49:

Closing 01 to 09

CL0x

41 to 49

x=1 to 9

 

50 to 59:

Bypass 10 to 19

sB1x

50 to 59

x=0 to 9

60:

Trouble AC

ATss

60

 

 

61 to 68:

Trouble 01 to 08

sT0x

61 to 68

x=1 to 8

69:

Trouble BAT

YTss

69

 

70:

Restore AC

ARss

70

 

 

71 to 78:

Restore 01 to 08

sRss

71 to 78

 

79:

Restore BAT

YRss

79

 

80:

Access

DS00

80

 

 

81 to 89:

Access 01 to 09

DG0x

80 to 89

x=1 to 9

90:

Opening

OP00

90

 

 

91 to 99:

Opening 01 to 09

OP0x

91 to 99

 

Bosch Security Systems, Inc. | 1/07 | 4998122703-01

23

Conettix D6600/D6100 | Computer Interface Manual |

3.0

Computer Communication Protocols

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.1.23 Silent Knight FSK2 (Message Type m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Silent Knight

D6500 Byte Description

 

 

 

 

 

 

 

 

 

 

 

FSK2 Example

1 2 3

4

5

6

7

8

9

10

11

12

13

14 15 16

17 18

19 20

21

22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*

t

 

 

 

 

 

h m r r l s a a a a a a a a “ E E Z Z “ *

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 28: Silent Knight FSK2 (Message Type m) Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#

Title

 

Description

 

 

 

 

 

 

 

 

 

1Header Character Optional. Check with the computer automation software for compatibility.

(h)

2

Message Type

m

3-4

Receiver Number

Receiver gateway number from 01 to 99.

5

Line/Group

Line number in the receiver gateway that sent the message.

 

Number

 

6

Spaces

One space.

7-14

Account Number

Maximum eight-digit account code. If the account code is less than eight digits, enter the

 

 

actual number of digits without a leading space.

15

Separator.

16-19

EEZZ

First event and zone number. If this is the only event, it will be ended with the terminator.

 

 

Up to eight reports. One report has four digits: one-digit event code, one-digit condition

 

 

code, two-digit zone code.

 

 

 

20

Separator.

21

***

Next data.

22

Trailer Character

Typically, HEX 14.

3.1.24 Silent Knight FSK80 D6500 mode (Message Type E)

Silent Knight

D6500 Byte Description

FSK80 Example

1 2 3

4

5

6

7

8

9

10

11

12

13

14 15 16

17 18

19 20

21

22

 

 

h E r r l s s s s s s A A A A s A s s X Y t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 29: Silent Knight FSK80 (Message Type E) Byte Description

 

 

 

 

 

 

 

 

#

Title

 

Description

1Header Character Optional. Check with the computer automation software for compatibility.

(h)

2

Message Type

E

3-4

Receiver Number

Receiver gateway number from 01 to 99.

5

Line/Group

Line number in the receiver gateway that sent the message.

 

Number

 

6-11

Spaces

 

12-15

Account Number

Four-digit account number.

 

 

 

16

Space

 

17

Filler character A

Always char “A”.

18-19

Spaces

 

20-21

XY

Two-digit alarm zone code.

 

 

 

24

Trailer Character

Typically, HEX 14.

 

 

 

24

Bosch Security Systems, Inc. | 1/07 | 4998122703-01

Conettix D6600/D6100 | Computer Interface Manual |

3.0

Computer Communication Protocols

 

 

 

3.1.25 Telim (Message Type n)

Telim Example

 

D6500 Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

3

 

 

 

 

4

 

 

5

 

 

6

 

7

 

8

 

 

9

 

 

10

 

 

11

 

 

12

 

 

13

 

14

 

15

 

 

16

 

17

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

h

 

n

 

 

R

 

 

R

 

L

 

s

 

A

A

 

A

 

 

A

 

A

 

A

 

s

E

T

 

T

 

 

Z

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

 

 

19

 

20

 

 

 

21

 

 

22

 

 

23

 

24

 

25

 

 

26

 

27

 

 

28

 

 

29

 

 

30

 

31

 

32

 

 

33

 

 

 

 

 

 

 

 

 

 

 

Z

 

Z

 

 

Z

 

 

Z

 

Z

 

Z

 

Z

Z

 

Z

 

 

Z

 

Z

 

Z

 

Z

Z

Z

 

t

 

 

Z

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 30: Telim (Message Type n) Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#

 

 

Title

 

 

 

 

 

 

 

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

Header Character

 

 

Optional. Check with the computer automation software for compatibility.

 

 

 

 

 

 

 

 

 

 

 

 

 

(h)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

Message Type

 

 

 

n

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3-4

 

 

Receiver Number

 

 

Receiver gateway number from 01 to 99.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

Line/Group

 

 

 

 

 

 

Line number in the receiver gateway that sent the message.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

Space

 

 

 

 

 

 

One space.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7-12

 

 

Account Number

 

 

Six digit account number.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

 

 

Space

 

 

 

 

 

 

One space.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14

 

 

E

 

 

 

 

 

 

 

 

 

Event code.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15-32

 

 

TTZZZZZZZZZZZZ

 

 

Input line number.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

33

 

Trailer Character

 

 

Typically, HEX 14.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.1.26 Text Message (Message Type 3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type 3 Example

D6500 Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

2

 

3

 

4

 

5

 

6

 

7

 

8

9

 

10

 

11

 

12

 

13

14

 

15

 

16

 

17

18

19

 

20

21

 

22

 

 

 

 

 

 

 

h 3 r r l P R I N T E R

 

 

 

 

 

 

 

 

 

 

 

v v . v v t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 31: Text Message (Message Type 3) Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#

 

Title

 

 

 

 

 

 

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1Header Character Optional. Check with the computer automation software for compatibility.

(h)

2

 

Message Type

3

 

3-4

 

 

Receiver Number

 

 

Receiver gateway number from 01 to 99.

5

 

Line Number

 

Line number fixed at 1.

6-21

 

 

Message Text

 

Sixteen characters in length.

22

 

Trailer Character

 

Typically, HEX 14.

Bosch Security Systems, Inc. | 1/07 | 4998122703-01

25

Conettix D6600/D6100 | Computer Interface Manual |

3.0

 

Computer Communication Protocols

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.1.27 Varitech FSK 4-1 (Message Type 1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Varitech FSK 4-1

D6500 Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example

 

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

 

 

 

 

 

h 1 r r l s s s s s s a a a a s E s s s X t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 32: Varitech FSK 4-1 (Message Type 1) Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#

Title

 

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1Header Character Optional. Check with the computer automation software for compatibility.

(h)

2

 

Message Type

1

3-4

 

Receiver Number

Receiver gateway number from 01 to 99.

5

 

Line/Group

Line number in the receiver gateway that sent the message.

 

 

 

Number

 

6-11

 

Spaces

Six spaces.

12-15

 

Account Number

Four digit account number.

16

 

Space

One space.

17

 

E

Event code.

 

18-20

 

 

Spaces

 

Three spaces.

21

 

X

Zone number.

22

 

Trailer Character

Typically, HEX 14.

 

 

 

 

 

 

 

3.1.28 Varitech FSK 4-2 (Message Type 1)

Varitech FSK 4-2

D6500 Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example

1

2

3

4

5

 

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

 

 

 

 

h 1 r r l s s s s s s a a a a s E s s X Y t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 33: Varitech FSK 4-2 (Message Type 1) Byte Description

#

Title

Description

1

Header

Optional. Check with the computer automation software for compatibility.

 

Character (h)

 

2

Message Type

1

3-4

Receiver Number

Receiver gateway number from 01 to 99.

5

Line/Group

Line number in the receiver gateway that sent the message.

 

Number

 

6-11

Spaces

Six spaces.

12-15

Account Number

Four digit account number.

16

Space

One space.

17

E

Event code.

18-19

Spaces

Two spaces.

20-21

XY

Zone number.

22

Trailer Character

Typically, HEX 14.

26

Bosch Security Systems, Inc. | 1/07 | 4998122703-01

Conettix D6600/D6100 | Computer Interface Manual |

3.0

Computer Communication Protocols

 

 

 

3.1.29 VONK (Message Type V)

 

 

D6500 Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VONK Example

1

 

 

2

 

3

 

4

 

5

 

6

 

 

7

 

 

8

 

 

9

 

 

 

10

 

11

 

 

12

 

 

13

 

14

 

15

 

16

 

17

 

18

 

19

 

20

 

 

21

 

 

22

 

 

23

 

24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

h V r r l A A 1 2 3 4 5 6 7 8 9 A B C D E F G t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 34: VONK (Message Type V) Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#

Title

 

 

 

 

 

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Header Character

 

Optional. Check with the computer automation software for compatibility.

 

 

 

 

 

 

 

 

 

 

 

 

(h)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Message Type

 

 

V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3-4

Receiver Number

 

Receiver gateway number from 01 to 99.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

Line/Group

 

 

Line number in the receiver gateway that sent the message.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6-7

Account Number

 

Two digit account number.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8-23

Zone status

 

 

Status of zones 1 to 16. If the zone is Closed, a “.”(Period) is in this position. If the zone is

 

 

 

 

 

 

 

 

 

 

 

Open, 1 to G appears in this position.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24

Trailer Character

 

Typically, HEX 14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.1.30 X-SIA Text (Message Type S)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X-SIA Example

D6500 Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

 

5

 

 

6

 

7

 

8

 

9

 

10

 

11

12

13

 

14

15

16

17

18

 

19

 

20

 

21

 

22

 

 

 

h S r r l [ # a a a a | E M M Z Z Z Z * ` T

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

23

 

24

25

26

 

 

27

 

28

 

29

 

30

 

 

31

 

32

 

 

33

 

34

35

 

36

 

37

 

38

39

40

 

41

 

42

 

 

 

 

 

 

 

 

T T T T T T T T T T T T ‘ N M / * * * t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 35: X-SIA Text (Message Type S) Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#

Title

 

 

 

 

 

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1Header Character Optional. Check with the computer automation software for compatibility.

(h)

2

 

Message Type

 

S

 

3-4

 

 

Receiver Number

 

 

Receiver gateway number from 01 to 99.

5

 

Line/Group

 

Line number in the receiver gateway that sent the message.

 

 

 

 

Number

 

 

6

 

[

 

 

Open bracket.

7

 

#

 

#

 

 

 

 

 

 

8-11

 

 

Account Number

 

Use up to sixteen digits in the account number.

12

 

|

 

 

Separator. Indicates more data positions after account number.

13

 

 

E

 

SIA block code.

14-15

 

 

MM

 

SIA event code.

 

 

 

 

 

 

16-19

 

 

ZZZZ

 

Zone number.

20

 

*

 

 

Text identifier.

21

 

 

 

Quotation mark (single).

22-34

 

TT…T

 

13 character text string.

 

35

 

 

 

 

Qutotation mark (single).

36-37

 

 

NM

 

Unit field characters.

 

 

 

 

 

 

38

 

/

 

 

Separator.

39-41

 

***

 

 

Next block of data.

42

 

 

Trailer Character

 

Typically, HEX 14.

 

 

 

 

 

 

 

 

Bosch Security Systems, Inc. | 1/07 | 4998122703-01

27

 

Conettix D6600/D6100 | Computer Interface Manual |

3.0

 

 

Computer Communication Protocols

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.1.31 SafeCom (Message Type p)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SafeCom Example

D6500 Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

3

 

4

 

5

 

6

 

7

 

8

 

9

 

10

 

11

 

12

 

13

 

14

 

...

 

N-1

 

N

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

h

p

r

 

r

l

A

A

A

A

E

E

E

E

. . . data . . .

t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 36: SafeCom (Message Type p) Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#

Title

 

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1Header Character (h) Optional. Check with the computer automation software for compatibility.

2

Message Type

p

3-4

Receiver Number

Receiver gateway number from 01 to 99.

5Line Card Number Line number in the receiver gateway that sent the message.

6-9

Account Number

Four digits.

10-13

Event Code

Four digits.

14-(N-1)

Data

Parameter data for event code.

N

Trailer Character

Typically, HEX 14.

3.2SIA Mode Messages

Use the SIA mode for central station monitoring.

3.2.1Acron Super Fast (Message Type 9)

Acron Super Fast SIA Mode Description

Example <LF><CRC><9><sequence#><receiver#><line#>[#aaaa|CCCCCCCC]<CR>

Table 37: Acron Super Fast (Message Type 9) Byte Description

 

 

Title

Description

L

Standard line feed character.

CRC

Cyclical redundancy check number.

Message Type

9

sequence#

The message sequence number. The valid sequence number range is 0001 to 9999.

 

 

receiver#

The receiver gateway that sent the message. Valid digits are 01 to 99 for the

 

D6600/D6100.

line#

The line number of the line in the receiver gateway that sent the message. Valid digits are 00

(Line/Group #)

to 99. The receiver uses Line 0 (zero) for internal messages.

account#

The communicator's account number has four digits.

Figure 7: Message sent to printer

mm/ddshh:mmsLxxsACNsACCTsaaaa+++sACCsa aaasCCCCsCCCC

For lines that are grouped, Gxx appears instead of Lxx.

Table 38: Acron Super Fast (Message Type 9)

 

Printer Output

 

 

 

 

 

 

Characters

 

Description

ACN

 

Acron Super Fast format.

Lxx

 

Line number.

Gxx

 

Grouped line numbers.

28

Bosch Security Systems, Inc. | 1/07 | 4998122703-01

Conettix D6600/D6100 | Computer Interface Manual |

3.0

Computer Communication Protocols

 

 

 

3.2.2Ademco Contact-ID (Message Type a)

Contact-ID

SIA Mode Description

 

Example

<LF><CRC><a><sequence#><receiver#><line#>[#aaaa|18QXYZGGCCC]<CR>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 39: Ademco Contact-ID (Message Type a) Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Title

 

 

 

Description

 

 

LF

 

 

 

Standard line feed character.

 

 

CRC

 

 

 

Cyclical redundancy check number.

 

 

Message Type

 

 

 

a

 

 

sequence#

 

 

 

The message sequence number. The valid sequence number range is 0001 to 9999.

 

 

 

 

 

 

 

 

 

receiver#

 

 

 

The receiver gateway that sent the message. Valid digits are 01 to 99 for the

 

 

 

 

 

 

D6600/D6100.

 

 

line#

 

 

 

The line number of the line in the receiver gateway that sent the message. Valid digits are 00

 

 

(Line/Group #)

 

 

 

to 99. The receiver uses Line 0 (zero) for internal messages.

 

 

 

 

 

 

 

 

 

account#

 

 

 

The communicator's account number has four digits.

 

18

 

 

 

Ademco Contact-ID format number.

 

 

Q

 

 

 

Qualifier, 1 = New event or opening, 3 = New restore or closing, 6 = Previous event.

 

 

XYZ

 

 

 

Class code and event code (refer to Appendix A: Contact ID Event Code Classifications on

 

 

 

 

 

 

page 53).

 

 

GG

 

 

 

Group number.

 

 

CCC

 

 

 

Zone codes or User ID.

 

Figure 8: Message sent to printer

mm/ddshh:mmsLxxsCIDsACCTsaaaa+++sACCsa

aaasNNNsEVENT=XYZsG=GGsC=CCC

For lines that are grouped, Gxx appears instead of Lxx.

Table 40: Ademco Contact-ID (Message Type a)

 

 

Printer Output

 

 

 

 

 

 

 

 

 

 

 

Characters

 

Description

 

 

 

 

 

CID

 

Contact-ID format.

 

 

Gxx

 

Grouped Line numbers.

 

Lxx

 

Line number.

 

 

NNN

 

If Q = 1, print E/O for new event or

 

 

 

opening If Q = 3, print R/C for restore or

 

 

 

closing If Q = 6, print “OLD” for old

 

 

 

messages and events.

Bosch Security Systems, Inc. | 1/07 | 4998122703-01

29

Conettix D6600/D6100 | Computer Interface Manual |

3.0

Computer Communication Protocols

 

 

 

3.2.3Ademco 4-1 Express (Message Type b)

4-1 Express

SIA Mode Description

 

Example

<LF><CRC><b><sequence#><receiver#><line#>[#aaaa|X]<CR>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 41: Ademco 4-1 Express (Message Type b) Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Title

 

 

 

Description

 

 

 

 

 

 

 

 

 

LF

 

 

 

Standard line feed character.

 

 

CRC

 

 

 

Cyclical redundancy check number.

 

 

Message Type

 

 

 

b

 

 

sequence#

 

 

 

The message sequence number. The valid sequence number range is 0001 to 9999.

 

 

receiver#

 

 

 

The receiver gateway that sent the message. Valid digits are 01 to 99 for the

 

 

 

 

 

 

D6600/D6100.

 

 

line#

 

 

 

The line number of the line in the receiver gateway that sent the message. Valid digits are 00

 

 

(Line/Group #)

 

 

 

to 99. The receiver uses Line 0 (zero) for internal messages.

 

 

 

 

 

 

 

 

 

account#

 

 

 

The communicator's account number has four digits.

 

 

X

 

 

 

Zone number

 

Figure 9: Message sent to printer

mm/ddshh:mmsLxxsE41sACCTsaaaasEVENT=X

For lines that are grouped, Gxx appears instead of Lxx.

Table 42: Ademco 4-1 Express (Message

 

Type b) Printer Output

 

 

 

 

 

 

Characters

 

Description

 

 

 

E41

 

Ademco 4-1 Express format.

Lxx:

 

Line number.

Gxx

 

Grouped line numbers.

30

Bosch Security Systems, Inc. | 1/07 | 4998122703-01