Bosch APC-AMC2-4WUS, APC-AMC2-4W, APC-AMC2-4WCF User Manual

4 (2)

AMC2 4W

APC-AMC2-4W | APC-AMC2-4WCF | APC-AMC2-4WUS

en Installation manual

AMC2 4W

| en 3

Remarks

This hardware is part of a security system. Access shall be limited to authorized persons only.

Some states do not allow the exclusion or limitation of implied warranties, or limitation of liability for incidental or consequential damages, so the above limitation or exclusion might not apply to you.

Bosch Security Systems retains all rights not expressly granted. Nothing in this license constitutes a waiver of Bosch’s rights under the U.S. Copyright laws or any other federal or state law. If you have any questions concerning this license, please, write to:

Bosch Access Systems GmbH

Adenauerstr. 20 / A3

D-52146 Würselen

Germany.

Bosch Security Systems

Installation manual

F.01U.024.965 | V.4 | 2006.09

4 en |

 

AMC2 4W

Table of Contents

 

 

 

 

1

Please read carefully

7

1.1

Explanation of Used Symbols

7

1.2

Internet

7

 

 

 

2

Safety Instructions

8

2.1

Important Safety Notes

8

2.2

FCC & ICES Information

10

2.3

Safety Precautions

11

2.4

Unpacking

12

 

 

 

3

Introduction

13

3.1

Description of the AMC2 4W

13

3.2

Equipment Configuration

15

3.3

Performance Characteristics

18

3.4

System Overview

19

 

 

 

4

Technical Data

20

 

 

 

5

Installing

22

5.1

Mounting

22

5.2

Demounting

23

5.3

Opening the AMC2 4W Case

24

5.4

Cabling

25

5.4.1

Conductor data for connection to power supply

25

5.4.2

Grounding and Shielding the Host Interface

26

5.4.3

Grounding and Shielding the Extension Interface

28

5.5

Connecting Power Supply

28

5.6

RS-485 Host Interface

30

5.6.1

RS-485 Two Wire Connection

32

5.6.2

RS-485 Four Wire Connection

33

5.6.3

DIL Switch Address Selector

34

5.7

RS-232 Host Interface

36

5.8

Ethernet Interface

37

F.01U.024.965 | V.4 | 2006.09

Installation manual

Bosch Security Systems

AMC2 4W

 

| en 5

5.9

RS-485 Extension Module Bus

39

5.10

Wiegand Interface for Card Readers

39

5.11

Connecting Relay Outputs

41

5.12

Connecting Analog Input Devices

44

5.13

Tamper Protection

46

 

 

 

6

Operating

48

6.1

Status Display of the AMC2 4W

48

6.2

Configuring the Ethernet Interface

50

6.3

Resetting the AMC2 4W

50

6.3.1

Resetting the Software

50

6.3.2

Resetting the Network Configurations

51

 

 

 

7

Appendix

53

7.1

Connecting Diagrams

53

7.2

Legend

57

 

 

 

8

Index

58

Bosch Security Systems

Installation manual

F.01U.024.965 | V.4 | 2006.09

6 en |

AMC2 4W

F.01U.024.965 | V.4 | 2006.09

Installation manual

Bosch Security Systems

AMC2 4W

Please read carefully | en 7

1Please read carefully

1.1Explanation of Used Symbols

Throughout this document, helpful tips, important notes, cautions and warnings will be presented for the reader to keep in mind. These appear different from the rest of the text as follows:

CAUTION! or WARNING!

!These warn the operator that damage to the program or equipment might occur.

 

NOTE!

i

Important Notes must be followed for successful operation

and programming. Tips and shortcuts might also be included

 

here.

 

 

1.2Internet

If you are interested in further information on this product or information on other products, please, refer to our website at http://www.bosch-security-systems.com.

Bosch Security Systems

Installation manual

F.01U.024.965 | V.4 | 2006.09

8 en | Safety Instructions

AMC2 4W

2Safety Instructions

2.1Important Safety Notes

1.Read, Follow, and Retain Instructions - All safety and operating instructions must be read and followed properly before putting the unit into operation. Retain instructions for future reference.

2.Consider all Warnings - Adhere to all warnings on the unit and in the operating instructions.

3.Accessories - Use only accessories recommended by the manufacturer or those sold with the product. Accessories not recommended by the manufacturer shall not be used, as they may cause hazards.

4.Installation Precautions - Do not place this unit on an unstable stand, tripod, bracket, or mount. The unit may fall, causing serious injury to persons and damage to the unit. Mount the unit according to the manufacturer’s instructions.

5.Service - Do not attempt to service this unit by yourself. Opening or removing covers may expose you to dangerous voltages or other hazards. Refer all servicing to qualified service personnel.

6.Damage Requiring Service - Disconnect the unit from the main AC or DC power source and refer servicing to qualified service personnel under the following conditions:

When the power supply cord or plug is damaged.

If liquid has been spilled or an object has fallen into the unit.

If the unit has been exposed to water and/or inclement weather (rain, snow, etc.).

If the unit does not operate normally, when following the operating instructions. Adjust only those controls specified in the operating instructions. Improper adjustment of other controls may result in damage, and require extensive work by a qualified technician to restore the unit to normal operation.

F.01U.024.965 | V.4 | 2006.09

Installation manual

Bosch Security Systems

AMC2 4W

Safety Instructions | en 9

If the unit has been dropped or the cabinet damaged.

If the unit exhibits a distinct change in performance, this indicates that service is needed.

7.Replacement Parts - When replacement parts are required, the service technician shall use replacement parts that are specified by the manufacturer. Unauthorized substitutions may result in fire, electrical shock or other hazards.

8.Safety Check - Upon completion of service or repair work on the unit, ask the service technician to perform safety checks to ensure that the unit operates properly

9.Power Sources - Operate the unit only from the type of power source indicated on the label. If unsure of the type of power supply to use, contact your dealer

For units intended to operate from battery power, refer to the operating instructions.

For units intended to operate with External Power Supplies, use only the recommended approved power supplies.

For units intended to operate with a limited power source, this power source must comply with EN/UL 60950. Substitutions may damage the unit or cause fire or shock.

For units intended to operate at 12/24V DC normal input voltage is 12/24V DC. Voltages applied to the unit’s power input shall not exceed 15/30V DC.

10.Lightning - For added protection during a lightning storm, or when this unit is left unused for long periods of time, disconnect the unit from power. This will prevent damage to the unit due to lightning and excessive power line surges.

11.Restricted Access Locations are required for the installation.

Bosch Security Systems

Installation manual

F.01U.024.965 | V.4 | 2006.09

10 en | Safety Instructions

AMC2 4W

2.2FCC & ICES Information

This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. The limits are designed to provide reasonable protection against harmful interference in a residental installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

1.Reorient or relocare receiving antenna

2.Increase the separation between the equipment and the receiver

3.Connect the equipment into an outlet on a circuit different from that to which the receiver is connected

4.Consult the dealer or an experienced radio/TV technician for help

F.01U.024.965 | V.4 | 2006.09

Installation manual

Bosch Security Systems

AMC2 4W

Safety Instructions | en 11

2.3Safety Precautions

Read instructions!

!Before working with the AMC2 4W, read these instructions carefully. Make sure you have understood all information

described in this document.

Warning! Risk of electric shock!

!External power supplies must be installed and put into service by qualified personnel. Compliance with the relevant regula-

tions must be ensured.

Warning! Risk of damaging equipment!

!

Always switch off power of the AMC2 4W before mod-

ifying the installation.

Do not connect or disconnect plug connectors, data

 

 

cables or screw connectors while power is on!

Health and Safety

Installation of the AMC2 4W must comply with any local fire, health and safety regulations. A secured door that may be part of an escape route from an area must be installed with:

! A fail-safe lock. So that the door will be released if power fails. Ideally, a magnetic lock should be used as these are less likely to jam or seize.

A normally-closed break-glass or manual pull in the lock supply wiring, so that in an emergency the failsafe lock can be immediately powered down.

Bosch Security Systems

Installation manual

F.01U.024.965 | V.4 | 2006.09

12 en | Safety Instructions

AMC2 4W

CAUTION!

!Disconnect both AC and battery power supply before working on the controller.

Warning! Risk of damage!

!Protect the hardware from electrostatic discharge by observing ESD instructions before unpacking or touching connectors or

electronics.

CAUTION: Lithium Battery

Danger of explosion if battery is replaced incorrectly. Replace

!only with the same type as recommended by the manufacturer. Dispose used batteries according to the battery manufacturer’s

instructions.

2.4Unpacking

Check the packaging for visual damage. If anything has been damaged during transport, make the transport agency aware of this.

Carefully unpack the unit. This is an electronic device that must be handled with care to avoid damage. Do not attempt to put the unit into operation if components are damaged.

If parts are missing, inform your customer service representative or a Bosch Security Systems salesperson. The shipping carton is the safest transport container for the unit. Store it and the other packaging material for future use. If the unit has to be sent back, use the original packaging.

F.01U.024.965 | V.4 | 2006.09

Installation manual

Bosch Security Systems

AMC2 4W

Introduction | en 13

3Introduction

3.1Description of the AMC2 4W

The AMC2 4W is equipped with four independent interfaces for Wiegand type readers. By that it is able to control two doors with a reader in each direction and up to four doors with a reader in one direction only.

Fig. 3.1 The Access Modular Controller AMC2 4W

All necessary information for access verification is stored in a battery buffered on-board memory and a Compact Flash (CF) memory card. This guarantees autonomous access decisions and complete access registrations even if the management host system is offline. The built in compact flash adapter provides adequate storage capability for cardholders and events.

The AMC2 4W electronic is completely covered by a plastic housing. The LC Display provides all important status information.

Using the AMC2 4W gives you the full functionality and the offline capability of a complete access control system on each room. This leads to an excellent reliability and a very high redundancy without paying extra money.

Bosch Security Systems

Installation manual

F.01U.024.965 | V.4 | 2006.09

14 en | Introduction

AMC2 4W

Fig. 3.2 The AMC2 4W in a four door safety lock

The AMC2 4W can communicate upstream to the host computer via eight RS-485 multi-dropped, RS-232 or 10/100 Mbit/s Ethernet. It has eight analog input devices and eight relay outputs. With its analog input devices, the AMC2 4W verifies, for example, if a lock is closed or open. The relay outputs can be used to activate lock mechanisms if access is granted, or activate an external alarm system if an intrusion or system alert is detected. If the eight input and output on board are not enough to configure the system up to three additional extensions (AMC2 8I-8O-EXT or AMC2 16I-16O-EXT) can be connected. The extensions offer 8 or 16 additional inputs and outputs.

The setup procedure for an AMC2 4W is very simple and extremely fast by the use of door templates. Once selected, all the inputs and outputs are predefined. This settings can be changed using the Device Editor of the BIS Configuration Browser in that way to choose every free contact of the

AMC2 4W or an connected extension.

F.01U.024.965 | V.4 | 2006.09

Installation manual

Bosch Security Systems

AMC2 4W

Introduction | en 15

3.2Equipment Configuration

Fig. 3.3 Upper circuit board with display (top side)

1.Internal tamper contact

2.DIL switch for RS-485 address selection, protocol and RS- 232/RS-485 selection

3.Lithium battery for buffering of static RAM and real time clock (RTC). The battery shall be replaced by qualified personnel every ten years or if indicated by an appropriate event.

4.Reset push button - available by using the srew driver

5.LC Display

6.Push button to select the display view - available by using the push button on the top of the housing

7.Jumper: Potential equalization between different mass systems and protective earth (shield)

8.Jumper: interface selector RS-485 Host connection, RS485 two wire or RS-485 four wire (depends on external wiring)

9.Configurable RS-485 host interface (pluggable screw connector)

10.Docking station for the compact flash

Bosch Security Systems

Installation manual

F.01U.024.965 | V.4 | 2006.09

Bosch APC-AMC2-4WUS, APC-AMC2-4W, APC-AMC2-4WCF User Manual

16 en | Introduction

AMC2 4W

11.Configurable RS-232 host interface (ribbon cable connector)

12.Configurable 10/100 Mbit/s Ethernet interface

Fig. 3.4 Overview - Interfaces

13.RS-485 extension module bus (Pluggable screw connector)

14.External tamper contact (Pluggable screw connector)

15.Power supply (Pluggable screw connector)

16.Wiegand interfaces for up to 4 card readers (Pluggable screw connector)

17.Connectors for eight analog inputs (Pluggable screw connector)

18.Connectors for eight relay outputs (Pluggable screw connector)

F.01U.024.965 | V.4 | 2006.09

Installation manual

Bosch Security Systems

AMC2 4W

Introduction | en 17

Fig. 3.5 Jumper at the bottom side

19.Jumper: Selector for either potential free relay output or powered by AMC2 4W internal power supply (wet/dry contacts).

20.Jumper: Potential equalization between different mass systems and protective earth (shield)for the extension interface.

Bosch Security Systems

Installation manual

F.01U.024.965 | V.4 | 2006.09

18 en | Introduction

AMC2 4W

3.3Performance Characteristics

Intelligent access manager for 1 ... 4 entrances (e.g. doors, man traps, barriers)

Host address selectable via DIL sliding switch

Four possible configurable host interfaces:

RS-485 2-wire

RS-485 4-wire

RS-232

Ethernet

Four peripheral input devices via Wiegand interface

Eight relay outputs

potential-free or

with internal power supply

Eight analog inputs with internal power supply

Battery buffered SRAM and real time clock (RTC)

Pluggable Compact Flash from 64 MB to 1024 MB

LC Display

Transfer rate host interface RS-485: 38,4 kBit/s

Transfer rate host interface RS-232: 38,4 kBit/s

Transfer rate host interface Ethernet: 10/100 Mbit/s

Self controlling transfer-receive-switching

Power supply for internal electronics: 10V - 30VDC - max. 5A

Tamper contact for internal and external covers

The AMC2 4W is to be used with power supply AMC PBC-60 (F.01U.026.573) with integrated UPS.

F.01U.024.965 | V.4 | 2006.09

Installation manual

Bosch Security Systems

Loading...
+ 42 hidden pages