Bosch 24CDI, 28CDI User Manual

0 (0)

 

 

 

 

 

Vote

for your

at

 

year’

‘Installer

of the

 

 

-bosch.co.uk

 

 

.worcester

 

 

www

 

 

 

 

24CDi, 28CDi & 35CDi II COMBI

Worcester supports the

Benchmark code of practice

 

G.C. NUMBERS

 

APPLIANCE

NATURAL GAS

L.P.G.

24CDi Fanned Flued (RSF)

47 311 30

47

311 31

24CDi Balanced Flued (BF)

47 311 29

 

 

24CDi Open Flued (OF)

47 311 32

47

311 33

28CDi Fanned Flue (RSF)

47 311 34

47

311 35

35CDi II Fanned Flue (RSF)

47 311 58

47

311 59

USER INSTRUCTIONS & CUSTOMER CARE GUIDE

Bosch 24CDI, 28CDI User Manual

EXCELLENCE COMES

AS STANDARD

Thank you for purchasing a Worcester CDi gas-fired combination appliance.

The CDi appliances are made by Worcester and the strictest quality control standards are demanded throughout every stage of production.

Indeed, Worcester, part of the Bosch Group have led the field in innovative appliance design and performance for more than 40 years.

The result is that your new Worcester CDi appliance offers you the very best of everything - quality, efficiency, economical running costs, proven reliability and value for money.

What’s more, you also have the assurance of our nononsense 1 year parts and labour guarantee.

And, to keep your boiler operating at peak condition and efficiency, an optional maintenance scheme is available from Worcester. Contact our Service Contracts team on 01905 754624 for further details.

CONTENTS

Page No.

Operating Instructions

.................................... 3-11

Fault and Breakdowns 12

Maintenance and

Extended Warranty

Information ............ 13-14

Guarantee Details .. 15-16

2

GENERAL

INFORMATION

GAS SAFETY (INSTALLATION AND USE) REGULATIONS 1998

It is the law, in GB, that all gas appliances must be installed by a competent person in accordance with the above regulations. Failure to install appliances correctly could lead to prosecution. It is in your interest and that of safety to ensure compliance with the law. The manufacturer’s notes must not be taken, in any way, as over-riding statutory obligations.

In GB, a competent person is someone registered with CORGI. All CORGI registered installers carry a CORGI ID card and have a registration number. Both should be recorded in the BENCHMARK checklist. You can check that your installer is CORGI registered by calling CORGI on 01256 372300.

WARNING: This appliance must be earthed and protected by a 3 amp fuse.

ELECTRICITY SUPPLY: 230V ~ 50Hz

IMPORTANT: To get the best from your Worcester CDi please read these instructions carefully.

NOTE: In the event of a fault the appliance should not be used until the fault has been corrected by a competent person.

BENCHMARK

The Benchmark initiative is a code of practice to encourage the correct installation, commissioning and servicing of domestic central heating boilers and system equipment.

A checklist can be found in the back of every installation manual. This is a vital document that needs to be completed by the installer at the time of installation. It confirms that the boiler has been installed and commissioned according to the manufacturers instructions.

In Eire the declaration found in IS 813 must be completed. Without completion of the checklist and/or declaration, manufacturers may refuse to respond to a call-out request. It is important that the checklist and/or declaration are fully completed by your installer.

GENERAL DESCRIPTION

(See Fig.1.)

The WORCESTER CDi MODELS are combined domestic hot water and central heating appliances. They consist of a gas fired boiler having a varying output of between:

 

CH

 

DHW

24CDi

9.0 - 24kW

9.0 - 24kW

28CDi

9.0 - 24kW

9.0

- 28kW

35CDi II

10.5 - 27.5kW

9.5 -

35.3kW

a heat exchanger to provide domestic hot water via the boiler, circulating pump and water diverting valve. All the necessary controls to provide mains fed domestic hot water and central heating.

The appliances are supplied as standard with a manual operating switch. Alternatively a facia mounted programmer may have been fitted.

The appliances can operate in one of two modes. Hot water only or hot water and central heating.

3

Hot Water Mode:

The appliance operates to supply only domestic hot water when the heating temperature mode is fully anti-clockwise, at the position or the timer is programmed to OFF mode.

A flow restrictor is fitted within the appliance which limits a hot water delivery rate to a maximum of:

24CDi

9.0 (±15%) litres/minute

28CDi

10.0 (±15%) litres/minute

35CDi II 12.0 (±15%) litres/minute

Hot Water and Central Heating mode:

Fig. 1. System Diagram.

Automatic air vent

Gas to water heat exchanger

Boiler

Circulating

pump Expansion vessel

Water to

Pressure

water heat

relief valve

exchanger

 

Diverter valve

CH

Domestic

Domestic CH

Safety dis-

flow

hot water

cold supreturn

charge

 

out

ply

 

When a demand is made for heating by the system controls (i.e. a programmer or room thermostat), the pump will energise, circulating primary water around the heating system and the burner will light. The heat output from the appliance in this mode has been factory set to maximum. The appliance will operate as necessary to maintain the temperature of the radiators at the level set by the adjustment of the Heating Temperature Control Knob. (See Fig. 2.)

If the system no longer requires output to maintain the desired room temperature, the burner will extinguish. The pump will continue to run for a short period to dissipate the residual heat from the appliance and then switch off.

The appliance will supply heat to the central heating system as required. A demand for hot water at a tap or shower will override the central heating function for the period of the domestic hot water demand.

4

GENERAL NOTES

CENTRAL HEATING SYSTEM

During the first few hours of operation of the central heating system, check that all radiators are being heated at an even rate. Should the upper area of a radiator be at a lower temperature than the base of the radiator, it should be vented by releasing air through the venting screw at the top of each radiator. Make sure your installer shows you how to carry out the operation. Repeated venting will reduce the quantity of water in the system and this must be replenished for safe and satisfactory operation of the appliance. Should water leaks be found in the system or excessive venting be required from any radiator, your installer or heating engineer should be contacted and the system corrected.

Fig. 1a.

SEALED HEATING SYSTEM

The appliance can be fitted to a sealed heating sys-

 

 

tem which is pre-pressurised. In this case your installer

 

will advise you on the minimum and maximum pres-

 

sure that should be indicated on the pressure gauge. See

 

Fig. 2. Check regularly that this pressure is maintained

 

and contact your installer or maintenance engineer if

 

there is a permanent significant drop in pressure indi-

 

cated on the gauge. If the system loses pressure it

 

should be re-pressurised as instructed by the installer

 

(N.B. Maximum operating pressure 2.5 bar).

 

Re-pressurising The System (See Fig. 1a).

 

(If in doubt leave this procedure to your installer).

 

Remove the bottom panel to gain access to the fill-

 

ing loop assembly.

 

Insert the bayonet end of the filling key into the

 

corresponding cut outs in the filling loop housing and

Grey

twist to lock the key in place.

Turn the grey knob anti-clockwise to allow water

Knob

ingress and fill until the required pressure is reached.

 

 

Turn the grey knob clockwise to stop filling and

 

remove the filling key by lining up the bayonet end of

Filling Key

the key with the cut outs in the filling loop housing and

 

withdrawing the key.

 

N.B. The key must always be removed from the

 

filling loop housing after the system has been filled to

 

prevent accidental filling and to comply with Bylaw 14

 

of the Water Bylaws Scheme.

 

Store the key in a safe place for future use and

 

refit the bottom panel.

 

OPEN VENTED HEATING SYSTEM

 

The appliance may be fitted to an open vented

 

heating system your installer will advise you. There is

 

no need to observe the pressure gauge.

5

Loading...