Black Box SW981AE, SW982AE, SW981A, SW980A, SW980AE User Manual

...
0 (0)
Black Box SW981AE, SW982AE, SW981A, SW980A, SW980AE User Manual

MARCH 2000

SW980A SW980AE

SW981A SW981AE

SW982A SW982AE

Local/Remote Electronic Switches

®

 

 

BOX

BLACK

724

-746

-5500

 

 

 

R

B

A

2 TO

1

/ REMOTE

LOCAL

ITCH

SW

 

 

REMOTE

 

 

A

B

 

PW

R

 

CUSTOMER

Order toll-free in the U.S. 24 hours, 7

A.M. Monday to midnight Friday: 877-877-BBOX

SUPPORT

FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746

INFORMATION

Mail order: Black Box Corporation,

1000 Park Drive, Lawrence, PA 15055-1018

 

Web site: www.blackbox.com E-mail: info@blackbox.com

FCC/IC/CE STATEMENTS

FEDERAL COMMUNICATIONS COMMISSION AND INDUSTRY CANADA

RADIO-FREQUENCY INTERFERENCE STATEMENTS

This equipment generates, uses, and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference.

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of Industry Canada.

Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le Règlement sur le brouillage radioélectrique publié par Industrie Canada.

EUROPEAN UNION DECLARATION OF CONFORMITY

This equipment complies with the requirements of the European EMC Directive 89/336/EEC.

1

LOCAL/REMOTE ELECTRONIC SWITCHES

NORMAS OFICIALES MEXICANAS (NOM)

ELECTRICAL SAFETY STATEMENT

INSTRUCCIONES DE SEGURIDAD

1.Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado.

2.Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura.

3.Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben ser respetadas.

4.Todas las instrucciones de operación y uso deben ser seguidas.

5.El aparato eléctrico no deberá ser usado cerca del agua—por ejemplo, cerca de la tina de baño, lavabo, sótano mojado o cerca de una alberca, etc.

6.El aparato eléctrico debe ser usado únicamente con carritos o pedestales que sean recomendados por el fabricante.

7.El aparato eléctrico debe ser montado a la pared o al techo sólo como sea recomendado por el fabricante.

8.Servicio—El usuario no debe intentar dar servicio al equipo eléctrico más allá a lo descrito en las instrucciones de operación. Todo otro servicio deberá ser referido a personal de servicio calificado.

9.El aparato eléctrico debe ser situado de tal manera que su posición no interfiera su uso. La colocación del aparato eléctrico sobre una cama, sofá, alfombra o superficie similar puede bloquea la ventilación, no se debe colocar en libreros o gabinetes que impidan el flujo de aire por los orificios de ventilación.

10.El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores, registros de calor, estufas u otros aparatos (incluyendo amplificadores) que producen calor.

11.El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación, o como se indique en el aparato.

2

NOM STATEMENT, TRADEMARKS

12.Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no sea eliminada.

13.Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos, poniendo particular atención a los contactos y receptáculos donde salen del aparato.

14.El equipo eléctrico debe ser limpiado únicamente de acuerdo a las recomendaciones del fabricante.

15.En caso de existir, una antena externa deberá ser localizada lejos de las lineas de energia.

16.El cable de corriente deberá ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo.

17.Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilación.

18.Servicio por personal calificado deberá ser provisto cuando:

A:El cable de poder o el contacto ha sido dañado; u

B:Objectos han caído o líquido ha sido derramado dentro del aparato; o

C:El aparato ha sido expuesto a la lluvia; o

D:El aparato parece no operar normalmente o muestra un cambio en su desempeño; o

E:El aparato ha sido tirado o su cubierta ha sido dañada.

TRADEMARKS USED IN THIS MANUAL

Any trademarks used in this manual are acknowledged to be the property of the trademark owners.

3

LOCAL/REMOTE ELECTRONIC SWITCHES

Contents

Chapter

 

Page

1.

Specifications .............................................................................................

5

2.

Introduction ...............................................................................................

7

3.

Installation and Configuration .................................................................

8

 

3.1

Before You Install ................................................................................

8

 

3.2

The Setup Procedure ..........................................................................

9

4.

Operation .................................................................................................

17

 

4.1

Local Switching .................................................................................

17

 

 

4.1.1 ABC and ABCDE Switches (SW980 and SW982 Units) ........

17

 

 

4.1.2 X Switches (SW981 Units) ......................................................

18

 

4.2

Remote Switching .............................................................................

19

 

 

4.2.1 ABC and ABCDE Switches (SW980 and SW982 Units) ........

19

 

 

4.2.2 X Switches (SW981 Units) ......................................................

19

 

4.3

Test Results ........................................................................................

22

5.

Troubleshooting ......................................................................................

23

 

5.1

Calling Black Box ..............................................................................

23

 

5.2

Shipping and Packaging ...................................................................

23

4

CHAPTER 1: Specifications

1. Specifications

Compliance —

FCC Part 15 Subpart J Class A, IC Class/classe A

Data Rate —

Up to 256 kbps typical; higher speeds possible with

 

careful consideration of cabling and equipment

 

requirements

User Controls —

All models: Remote switching either through TTL,

 

RS-232, RS-422/485, or other active drivers or

 

through dry-contact closure;

 

SW980 and SW982 models: (1) Rear-mounted

 

2-position DIP switch for grounding;

 

SW981 models: (2) Rear-mounted 2-position DIP

 

switches for grounding

Indicators —

Front-mounted LEDs:

 

All models: (1) for Power;

 

SW980 models: (2) for Active Port;

 

SW981 models: (1) for Straight, (1) for Crossed;

 

SW982 models: (4) for Active Port

Connectors —

All models: (1) Rear-mounted RJ-45 female,

 

(1) Internal 4-position terminal block;

 

SW980 models: (3) Rear-mounted DB25 female;

 

SW981 models: (4) Rear-mounted DB25 female;

 

SW982 models: (5) Rear-mounted DB25 female

Leads Supported —

DB25: All

Signal Levels —

Between ±15 VDC maximum for all leads

“On” Resistance

 

Through Switch —

SW980 and SW981 models: 35 ohms maximum,

 

22 ohms typical;

 

SW982 models: 100 ohms maximum, 40 ohms typical

Port-to-Port

 

Switching Speed

 

Using Remote

 

Inputs —

Less than 1 µs

5

LOCAL/REMOTE ELECTRONIC SWITCHES

Remote Input

Logic Levels — VIH greater than 2.5 volts, maximum +15 volts; VIL less than 0.5 volts, minimum –15 volts

NOTE

For dry-contact operation, the total externalconnection DC resistance must be less than 240 ohms when the dry contact is closed for the Local/Remote Electronic Switch to correctly read this condition as a “low” input.

Power — SW980A, SW981A, SW982A:

From wallmount power supply PS154: Input: 120 VAC, 60 Hz;

Output: 17 VAC CT; SW980AE, SW981AE, SW982AE:

From wallmount power supply PS154E: Input: 230 VAC, 50 Hz;

Output: 17 VAC CT; Consumption: 1 watt

MTBF —

65,000 hours

Operating

Temperature — 32 to 140˚F (0 to 60˚C)

Storage

Temperature — –4 to +158˚F (–20 to +70˚C)

Humidity — Up to 95% noncondensing

Enclosure —

High-impact plastic

Size — SW980 and SW981 models: 2.5"H x 6"W x 6.3"D (6.4 x 15.2 x 16 cm);

SW982 models: 3.5"H x 6"W x 6.3"D (8.9 x 15.2 x 16 cm)

Weight —

1.5 lb. (0.7 kg)

6

CHAPTER 2: Introduction

2. Introduction

Switching between data lines manually can often damage the connected equipment, because this relatively slow and imprecise action can cause data-line surges and spikes large enough to damage today’s sensitive circuitry. With the Local/Remote Electronic Switches, you can eliminate this potential hazard. Their electronic switching action provides surgeless, spikeless changeovers—something a mechanical switch just can’t do.

In addition, these switches can be controlled remotely, from a convenient out-of-sight location.

The stock models available are:

SW980A

115-VAC 2-to-1 Switch

SW980AE

230-VAC 2-to-1 Switch

SW981A

115-VAC “X” (2-to-2) Switch

SW981AE

230-VAC “X” (2-to-2) Switch

SW982A

115-VAC 4-to-1 Switch

SW982AE

230-VAC 4-to-1 Switch

These Switches can also be cascaded to allow a larger number of ports to be switched.