Black Box LMC100AE-SMLC, LMC100A-SMLC, LMC100A-SMSC-R2, LMC100A-SMSC-SLH-R2, LMC100A-SMSC-LH-R2 User Manual

...
0 (0)
Black Box LMC100AE-SMLC, LMC100A-SMLC, LMC100A-SMSC-R2, LMC100A-SMSC-SLH-R2, LMC100A-SMSC-LH-R2 User Manual

LMC100A-SC-R2 LMC100A-RJ-R2 LMC100AE-SC-R2 LMC100AE-RJ-R2 LMC100A-SMSC-R2 LMC100A-SMSC-XLH-R2 LMC100AE-SMSC-R2 LMC100AE-SMSC-XLH-R2 LMC100A-R2 LMC100A-SMRJ-R2 LMC100AE-R2 LMC100AE-SMRJ-R2 LMC100A-SM-R2 LMC100A-SMSC-SLH-R2 LMC100AE-SM-R2 LMC100AE-SMSC-SLH-R2 LMC100A-SMSC-LH-R2 LMC100A-LC

LMC100AE-SMSC-LH-R2 LMC100AE-LC LMC100A-SMLC

LMC100AE-SMLC

FlexPoint10/100

CUSTOMER SUPPORT INFORMATION

LED Indicators:

Order toll-free in the U.S.: Call 877-877-BBOX

(outside U.S. call 724-746-5500)

FREE technical support 24 hours a day, 7 days a week; Call 724-746-5500 or fax 724-746-0746

Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018

Web site: www.blackbox.com E-mail: info@blackbox.com

LED

Color

Description

Power:

Yellow

Power applied

UTP Auto:

Green

Auto-Negotiation enabled

UTP FDx:

Green

Full-Duplex detected

UTP Link:

Green

Link / Data received

UTP 10:

Yellow

10 Mbps link detected

UTP 100:

Green

100 Mbps link detected

Fiber FDx:

Green

Full-Duplex selected

F/O Link:

Green

Link / Data received

SPECIFICATIONS:

 

Protocol:

 

IEEE 802.3

Connectors & Cables:

 

Twisted Pair UTP:

RJ45, Category 5 or higher

Fiber:

 

SC, ST or MT-RJ

Multimode:

 

50/125, 62.5/125, 100/140μm

Single-mode:

9/125μm

Supported Distances:

Half-Duplex Full-Duplex

Twisted PairUTP:

100m/328ft. 100m/328ft.

MM 1310nm fiber:

412m/1,350ft. 2km/1.2mi.

SM 1310nm fiber:

412m/1,350ft. 28km/16.8mi.

SM 1310nm LH fiber:

412m/1,350ft. 58km/36mi.

SM 1310nm XLH fiber: 412m/1,350ft. 85km/52.8 mi.

SM 1310nm SLH fiber: 412m/1,350ft. 110km/68.4 mi.

Dimensions / Weight:

W:3.0”xD:4.0”xH:1.0” / 6oz.

Power:

 

9VDC/500mA or 5VDC/750mA

Temperature:

0 to 40 degrees C

Humidity:

 

0-90% (non-condensing)

Overview and Description:

The FlexPoint 10/100 converts between Fast Ethernet fiber 100Base-Fx and 10Base-T or 100Base-Tx twisted pair (RJ45 UTP) cabling. It operates in half duplex (HD) or full duplex (FD).

The following FlexPoint 10/100 models are described here:

Model

Fiber Type

Distance

LMC100A-SC-R2

1310nm, MM, SC

2km / 1.2 mi.

LMC100AE-SC-R2

1310nm, MM, SC

2km / 1.2 mi.

LMC100A-SMSC-R2

1310nm, SM, SC

28km / 17.4 mi.

LMC100AE-SMSC-R2

1310nm, SM, SC

28km / 17.4 mi.

LMC100A-R2

1310nm, MM, ST

2km / 1.2 mi.

LMC100AE-R2

1310nm, MM, ST

2km / 1.2 mi.

LMC100A-SM-R2

1310nm, SM, ST

28km / 17.4 mi.

LMC100AE-SM-R2

1310nm, SM, ST

28km / 17.4 mi.

LMC100A-SMSC-LH-R2

1310nm,SM,SC

58km/ 35mi.

LMC100AE-SMSC-LH-R2 1310nm,SM,SC

58km/35mi.

LMC100A-RJ-R2

1310nm, MM,MTRJ

2km / 1.2mi.

LMC100AE-RJ-R2

1310nm, MM,MTRJ

2km / 1.2mi.

LMC100A-SMSC-XLH-R2 1550nm, SM,SC

85km / 52.8 mi.

LMC100AE-SMSC-XLH-R2

1550nm, SM, SC

85km / 52.8 mi.

LMC100A-SMRJ-R2

1310nm,SM,MTRJ

28km / 17.4 mi.

LMC100AE-SMRJ-R2

1310nm,SM,MTRJ

28km / 17.4 mi.

LMC100A-SMSC-SLH-R2 1550nm, SM,SC

110km/68mi.

LMC100AE-SMSC-SLH-R21550nm, SM, SC

110km/68mi.

LMC100A-LC

1310nm, MM, LC

2km/1.2mi.

LMC100AE-LC

1310nm, MM, LC

2km/1.2mi.

LMC100A-SMLC

1310nm, SM, LC

28km/17.4mi.

LMC100AE-SMLC

1310nm, SM, LC

28km/17.4mi

Installation and Configuration:

Power Adapter Notice:

1. When Using in a stand-alone configuration, this product is intended to be and must be used only with

TRADEMARKS USED IN THIS MANUAL

Black Box and the Double Diamon logo are registered trademarks of BB Technologies, Inc. Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owners.

FEDERALCOMMUNICATIONS COMMISSIONAND CANADIAN DEPARTMENT OFCOMMUNICATIONS RADIOFREQUENCYINTERFERENCESTATEMENTS

This equipment generates, uses, and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment. Operation of this equipment in a residential area is likely to be cause interference, in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference.

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of the Canadian Department of Communications.

Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numéirques de las classe A prescrites dans le Règlement sur le brouillage radioélectrique publié par le ministère des Communications du Canada.

a Listed Direct Plug-In Power Unit marked “Class 2” and rated at 9VDC, 1 Amp.

2.This product should always be used only with the Supplied Power Unit.

WARNING!

Before inserting the Power Adapter, verify that the power on the unit is appropriate

for yourAC line voltage source.

Mounting and Cable Attachment:

The FlexPoint 10/100 can be solo-mounted using a wall-mounting kit, or rack-mounted using a 5-position shelf or a high-density 14-unit FlexPoint Powered Chassis.

Attach the FlexPoint 10/100 UTP via a category 5 cable to a 10Base-T or 100Base-Tx Ethernet device.

Attach the FlexPoint 10/100 fiber via cable to a 100Base-Fx Fast Ethernet device. The FlexPoint transmit (Tx) must attach to the receive side on other device; the receive (Rx) must attach to the transmit.

Switch Settings:

“RJ45 Cross-Over” Switch:

When connecting the UTP to a hub or switch, set switch to “Straight-Through” (factory setting). When connecting to a workstation, set it to “Cross-Over.”

“UTP Auto/UTP Manual” Switch:

Setting the switch to “Auto” (factory setting) enables the UTP port to determine the speed and duplex mode automatically. If the connected device cannot provide the proper signal to indicate its own mode of operation, the “Manual” switch should be used. This feature allows connections with devices that do not auto-negotiate properly.

“UTP 10/UTP 100” Switch:

When the “Auto/Manual” switch is in “Manual” position,

NORMAS OFICIALES MEXICANAS (NOM)

ELECTRICAL SAFETY STATEMENT

1.Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado.

2.Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura.

3.Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben ser respetadas.

4.Todas las instrucciones de operación y uso deben ser seguidas.

5.El aparato eléctrico no deberá ser usado cerca del agua— por ejemplo, cerca de la tina de baño, lavabo, sótano mojado o cerca de una alberca, etc.

6.El aparato eléctrico debe ser usado únicamente con carritos o pedelstales que sean recomendados por el fabricante.

7.El aparato eléctrico debe ser montado a la pared o al techo sólo como sea recomendado por el fabricante.

8.Servicio—El usuario no debe intentar dar servicio al equipo eléctrico más allá a lo descrito en las instrucciones de operación. Todo otro servicio deberá ser referido a personal de servicio calificado.

9.El aparato eléctrico debe ser situado de tal manera que su posición no interfiera su uso. La colocación del aparato eléctrico sobre una cama, sofá, alfombra or superficie similar puede bloquea la ventilación, no se debe colocar en libreros o gabinetes que impidan el flujo de aire por los orificios de ventilación.

10.El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores, registros de calor, estufas u ostros aparatos (incluyendo amplificadores) que producen calor.

11.El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación, o como se indique en el aparato.

the “UTP 10/UTP 100” switch determines the speed of operation for the UTP port. When set to “UTP 100” (factory setting), the UTP port will operate at 100 Mbps. When set to “UTP 10” the UTP port will operate at 10 Mbps. Adjust the 10/100 Mbps switch to the speed of the connecting device and check for link status.

“UTP Full Duplex/UTP Half Duplex” Switch:

When the “Auto/Manual” switch is in “Manual” position, the “UTP Full Duplex/UTP Half Duplex” switch determines the duplex operation mode for the UTP port. When set to “Full Duplex” (factory setting), the UTP port will operate in full duplex. When set to “Half Duplex” the UTP port will operate in half duplex. Adjust the half/full-duplex switch to accommodate the connecting device and check for link status.

Half duplex must be used when connecting to a hub. Full duplex should be used when connecting switches or between a switch and a full-duplex workstation.

“Fiber Full Duplex/Fiber Half Duplex” Switch:

Since the IEEE 802.3 standard defines the Ethernet 10Base-FL fiber differently than the Fast Ethernet 100Base-Fx, it should be noted that they are incompatible. The FlexPoint 10/100 supports 100Base-Fx only. It operates in a halfor full-duplex mode of operation. This switch controls the half/full-duplex operation of the fiber port.

Half duplex should be used when connecting to a hub (with a shared/non-switched fiber port) or a workstation that supports only half-duplex. Full duplex can be used when connecting to a switch or a workstation that supports full-duplex operation.

©Copyright 2011. Black Box Corporation. All rights reserved.

1000 Park Drive · Lawrence, PA 15055-1018 724-746-5500 · Fax 724-746-0746

12.Precación debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no sea eliminada.

13.Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos, poniendo particular atención a los contactos y receptáculos donde salen del aparato.

14.El equipo eléctrico debe ser limpiado únicamente de acuerdo a las recomendaciones del fabricante.

15.En caso de existir, una antena externa deberá ser localizada lejos de las lineas de energia.

16.El cable de corriente deberá ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo.

17.Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilación.

18.Servicio por personal calificado deberá ser provisto cuando:

A:El cable de poder o el contacto ha sido dañado; u

B:Objectos han caído o líquido ha sido derramado dentro del aparato; o

C:El aparato ha sido expuesto a la lluvia; o

D:El aparato parece no operar normalmente o muestra un cambio en su desempeño; o

E:El aparto ha sido tirado o su cubierta ha sido dañada.

LMC100A-SC-R2, version 2

040-01009-R21B 3/11

Loading...
+ 1 hidden pages