Bionaire BCM645 User Manual

77.18 Kb
Loading...

BCM64505EM1.qxd 5/23/05 9:09 Page 1

10.Fill the reservoir and place back into housing.

11.Repeat Operating Instructions It will take about 30 minutes for the humidifier to reach maximum output. You can purchase replacement filters (model BWF100 filters) at your local retailer, by calling 1-800-253-2764, filling out the accessory card, or by visiting www.bionaire.com. It is recommended that a replacement filter is purchased for uninterrupted use.

CLEANING AND MAINTENANCE INSTRUCTIONS

Humidifiers provide comfort by adding moisture to dry, heated indoor air. To benefit most from the humidifier and avoid product misuse, follow all instructions carefully. Please note that this is an electrical appliance and requires attention when in use.

In addition, if you do not follow the recommended care and maintenance guidelines, micro-organisms may be able to grow in the water within the water tank. You must routinely follow the cleaning procedures that follow in order to ensure proper, efficient operation of your humidifier. Proper maintenance and cleaning is essential to the continued performance of your unit and the avoidance of algae or bacteria build-up.

DAILY MAINTENANCE

1.Be sure the unit is OFF and is disconnected from the electrical outlet.

2.Remove the housing and the tank from the humidifier and place in sink or tub.

3.Carry the base of the unit to the sink, remove the wick, place in sink, drain any remaining water and rinse thoroughly to remove any sediment or dirt. Wipe clean, and dry with a clean cloth or paper towel.

4.Drain the water from the tank into the sink and rinse tank thoroughly. Wipe clean, and dry with a clean cloth or paper towel.

5.Put filter back in, replace the housing, then refill tank with cool tap water as instructed earlier in the Filling Instructions. Do not overfill.

6.Follow Operating Instructions.

WEEKLY MAINTENANCE

To Remove Scale:

1.Repeat steps 1-4 above.

2.Clean the base by partially filling the base with one 8-oz cup of undiluted white vinegar, or by using CleanAwayTM (Model dms216) by the manufacturer. Leave this solution in the base for 20 minutes, while cleaning all interior surfaces with a soft brush. Remove base scale by wiping the base with a cloth dampened with undiluted white vinegar.

3.Rinse with clean warm water to remove the cleaning solution before disinfecting the tank.

TO DISINFECT RESERVOIR

1.Fill humidifier reservoir 1/2 full with water and 1/2 tablespoon of chlorine bleach.

2.Let the solution stand for 20 minutes, swishing every few minutes. Wet all surfaces.

3.Carefully empty the reservoir after 20 minutes, and rinse with warm water until you can not detect any bleach smell. Dry with a clean cloth or paper towel.

4.Place filter back into reservoir and refill the water reservoir as directed in Operating Instructions, and turn the unit on.

STORAGE INSTRUCTIONS

When not using your humidifier for an extended period of time:

1.Dispose of the filters. DO NOT leave in unit.

2.Clean, rinse and thoroughly dry the humidifier as directed in weekly maintenance. DO NOT leave any water in the unit when storing. Leaving water in the unit may render the unit inoperable for the following season.

3.Place the humidifier in the original carton and store in a cool, dry place.

4.Order your replacement filter for next year’s use.

SERVICE INSTRUCTIONS

1.Do NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void the warranty. The inside of the unit contains no user serviceable parts. All servicing should be performed by qualified personnel only.

2.If you need to exchange the unit, please return it in its original carton, with a sales receipt, to the store where you purchased it. If you are returning the unit more than 30 days after the date of purchase, please see the enclosed warranty.

3.Should your humidifier require service, please call 1-800-253-2764 in North America for further assistance.

4.If you have any other questions or comments, feel free to write to us or visit our website www.bionaire.com

The Holmes Group, Inc.

Consumer Service Department

13052 Jurupa Avenue

Fontana, CA 92337

Trouble Shooting

Trouble

Unit does not turn on

Mist output minimal to none

Filter Turns Brown

Probable Cause

Solution

Not plugged in

Plug in Unit

Filter has not absorbed

Wait 15 minutes for filter to

water

absorb water

The filter has absorbed

Replace your filter (BWF100)

minerals

by calling 1-800-253-2764

 

or visiting:

 

www.bionaire.com

 

 

FREQUENTLY ASKED QUESTIONS

Question

What are the variables that affect run time?

How do I remove film on water tank?

How can I extend the run time?

ANSWER

The estimated run time for this humidifier is based on average room conditions. The actual run time of your humidifier is dependent on numerous variables such as:

1.Air exchange in the room where the humidifier is placed.

2.Room construction of the room where the humidifier is placed.

3.Temperature of the room where the humidifier is placed.

4.Humidity levels in the room where the humidifer is placed.

5.Movement of occupants and the opening and closing of doors in the room where the humidifier is placed.

6.Home furnishings in the room where the humidifer is placed.

See Daily Maintenance instructions. Regular cleaning is recommended.

Run your unit on the lowest setting.

If your unit has electronics, set it to your desired humidity level. The unit will turn on and off, which will extend the run time.

Fill the tank all the way full, place it on the base, let the water empty into the base until it stops bubbling, then refill the tank full again. This ensures maximum water capacity and will extend run time.

WARRANTY

The Manufacturer warrants to the original retail purchaser, for TWO (2) YEARS from the date of original purchase, either to repair or replace at its option, without charge (parts and labor), any supplied or manufactured part of this humidifier which, upon inspection by an authorized service center, proves to have failed in normal use due to defects in material or workmanship, or, at its option, to replace the unit.

Operation under conditions other than those recommended or at voltages other than the voltage indicated on the unit, or any attempts by unauthorized personnel to service the unit or modify it, will render the guarantee void.

The Manufacturer shall not be liable for any personal injury, property damage or any incidental or consequential damages of any kind, resulting from defects, malfunctions, misuse, improper installation or alteration of the product.

THE MANUFACTURER EXPRESSLY DISCLAIMS ALL RESPONSIBILITY FOR CONSEQUENTIAL DAMAGES OR INCIDENTAL LOSSES CAUSED

BY USE OF THIS PRODUCT.

The provisions of this Warranty are in addition to, and not a modification of, or subtraction from the statutory warranties and other rights and remedies contained in any applicable legislation and to the extent that any such provision purports to disclaim, exclude or limit any such statutory warranties or other rights or remedies, such provisions shall be deemed to be amended to the extent necessary to comply therewith.

FOR WARRANTY SERVICE, PLEASE CALL 1-800-253-2764 IN NORTH AMERICA.

A consumer service representative will help determine which is the best procedure in order for your humidifier to be repaired.

KEEP THIS NUMBER FOR FUTURE REFERENCE.

Bionaire® , the Bionaire logo® and Clean-Away™ are trademarks of The Holmes Group, Inc.

BCM64505EM1

Printed In China

digital COOL MOISTURE

humidifier

MODEL BCM645

FILTER#: BWF100 (2)

Filter Type: Wick

Read instructions before operating.

Retain for future reference.

Instruction Leaflet

INFO-LINE

If after having read this leaflet, you have any questions or comments on your humidifier, call 1-800-253-2764 in North America.

9100030002513