NX20IL-G
Wiring Accessories
20A DP Switch
Wiring Instructions
Before commencing work always isolate the power at the consumer unit
/ fuse box.
*Note – If your installation uses a four-lug metal mounting box, remove the
top and bottom lugs or bend fully back.
1. Unscrew the accessory from the wall/mounting box.
2. Note the cable connections:
The illustration shows 1 wire of each colour connected to each terminal.
There should be an additional connection between the mounting box earth
terminal and the accessory earth terminal.
3. Unscrew each terminal to release the wire.
1. Install mounting box (metal or moulded) for either flush or surface
mounting, ensuring appropriate size of product (Mounting box to be
purchased separately).
2. Select the most suitable entry point of the mounting box (knock-out) and
route the cables through. If a metal box is used, a cable grommet should
be fitted to the entry point.
3. Cables should be prepared so a sufficient conductor length reaches the
terminals. Strip the ends of the individual conductors leaving an adequate
length bare to enter terminals.
1. Line up the new accessory to mounting box and take note of where each
terminal is located.
2. Connect each wire to the matching terminal.
An earth connection should always be made between the mounting box
earth terminal and the accessory earth terminal, where fitted.
All bare earth wires must be sheathed with green/yellow sleeving.
When connecting the new accessory ensure that only the bare end of the
wire enters the terminal and no bare wires are visible.
3. Tighten terminal screws securely. (Do not over tighten)
1. Carefully position the accessory into the mounting box, ensuring that no
wires are trapped between the plate and the wall and secure with screws
(do not over tighten) then insert screw covers (optional).
2. Once the installation has been completed correctly, replace the fuse/
reset MCB (trip), switch the power back on at the consumer unit and test.
The flex outlet arrangement comprises a fixed portion
integral to the main unit and a movable clamp portion,
held in place by a screwed fixing.
The appliance cable exits through the aperture on the
front/bottom face of the unit.
1. Prepare the flexible cable from the appliance as shown in the diagram.*
*NOTE - The cord clamps are reversible and should be orientated to suit
cable size to give proper clamping.
2. Loosen the cord grip screw fixing, remove blanking plug and pass cable
through the aperture.
3. Connect wires as shown in diagram.
4. Adjust protrusion of cable in clamp so that wires are not taut and then
fully tighten clamp to securely grip cable outer sheath.
DO NOT clamp on individual wires.
IMPORTANT
The cable MUST be clamped tight on outer sheath to ensure the cable connections are not damaged or disconnected through subsequent movement
of cable or appliance.
2a. Replacing an existing accessory
4. Complete Installation & Test
5. Products with Cord Clamps
1. Power Off
2b. New installation
3. Connection (See diagram)
55MM
8MM
Safety Warning
For your safety, this product must be installed in accordance with local
Building Regulations. If in any doubt, or where required by the law, con-
sult a competent person who is registered with an electrical self-certification scheme. Further information is available online or from your Local
Authority.
Please read carefully and use in accordance with these safety wiring
instructions. Before commencing any electrical work ensure the supply is
switched off at the mains. Either by switching off the consumer unit or by
removing the appropriate fuse or turning off MCB (trip). Wiring should be in
accordance with the latest edition of the IET regulations (BS 7671).
To prevent fire hazard always use cable of the correct rating & type for the
application.
Warning do not exceed the load rating of this device as stated on the rear
of the product.
Wire Identification – Twin & Earth Cable
Note - As from 1st April 2004 new colour codes for hard wire installations
were introduced.
EARTH = Green/Yellow Sleeving
NEUTRAL = Black (pre Apr 04) / Blue (after Apr 04)
LIVE = Red (pre Apr 04) / Brown (after Apr 04)
TO MOUNTING BOX
EARTH TERMINAL
EARTH TERMINAL
EARTH
20A DP Switch
TO LOAD
LIVE
LIVE
EARTH
EARTH
NEUTRAL
OUT
N
L
IN
L
N
NEUTRAL
20A DP Switch with cable outlet
OUT
N
L
IN
L
N
LIVE
NEUTRAL
TO LOAD
FROM SUPPLY
LIVE
EARTH
NEUTRAL
CORD GRIP

Additional Advice for Decorative Products
Fixing method varies depending on which product range is supplied.
Always ensure wall surface is reasonably flat and smooth, with no bumps
or projections. Metal frontplates WITH screw fixing holes, fix the unit to
the back box using two fixing screws supplied. All Decorative products
MUST have an earth connection between the frontplate and back box.
Frontplates WITHOUT screw fixing holes. These products comprise main
unit with integral gasket, and frontplate as separate item. Fix unit to
back box using two fixing screws supplied. Clip frontplate onto main
assembly, ensuring screwdriver notch is located bottom right hand
corner.
To remove plate, place medium size flat bladed screwdriver in notch and
lever off against gasket.
Technical
Voltage : 220-250V~
Frequency : 50/60Hz
Rating : 20A
SBL Rating : 250W
Terminal capacity : 4 x 1.5mm² 2 x 2.5mm² 1 x 4mm² 1 x 6.0mm²
Min box depth : 25mm
ASTA Approved
The ASTA quality mark is evidence that the product has been
independently tested to comply with the relevant clauses of the
applicable standards.
Lic No.1074
Batch Code explanation
yyWxx Manufacturing date code, year of manufacture (yy) and week of
manufacture (Wxx)
Care
To maintain the high quality appearance of decorative finish switches and
sockets, BG Electrical recommend the use of a soft cloth periodically to
clean the front face. When installing a decorative product please ensure
that the wall is decorated, finished and free of moisture prior to installation.
BG Electrical recommends avoiding using, but not restricted to, these
substances from becoming in contact with the decorative metal front-plates
when cleaning or decorating:
• Adhesive tape, including low tack masking tape
• Solvents
• White spirit
• Multi surface cleaners
• Industrial multipurpose cleaning wipes
• Wet wipes
Using items like those listed above may cause a degrading effect to
the front-plates lacquer/plated finish, although the function will remain
unaffected.
Address/Helpline
Luceco PLC
Stafford Park 1
Telford TF3 3BD
ENGLAND
If you have further technical assistance you can get in touch with our
Technical Helpline on:
+44 (0)3300 249 279
technical.support@bgelectrical.co.uk
(EU) Luceco SE
C/ Bobinadora 1-5
08302 Mataró
SPAIN
Environmental Protection
This symbol is known as the “Crossed-out Wheelie Bin
Symbol”. When this symbol is marked on a product or battery,
it means that it should not be disposed of with your general
household waste. Some chemicals contained within electrical/
electronic products or batteries can be harmful to health
and the environment. Only dispose of electrical/electronic/
battery items in separate collection schemes, which cater for
the recovery and recycling of materials contained within. Your
co-operation is vital to ensure the success of these schemes
and for the protection of the environment.