Important safety instructions

CAUTION: High voltage! Risk of death! High voltages of up to 500 V DC may be present inside the casing for long periods after being disconnected from the mains. To avoid lethal electric shock, do not open the casing. There are no user-serviceable components inside. Refer all maintenance to qualified service personnel. Remove the mains cable when the unit is not in use.

WARNING: To eliminate the risk of fire and electric shock, do not expose this unit to rain or moisture and splashing or dripping liquid, which might enter the device. Do not place any objects filled with liquid, such as vases, on the unit.

This symbol, wherever it appears, alerts you to the presence of uninsulated dangerous voltage

**inside the enclosure—voltage that may be sufficient to constitute a risk of shock.

This symbol, wherever it appears, alerts you to important operating and maintenance instruc-

!!tions in the accompanying literature. Please read the manual.

1)Read these instructions.

2)Keep these instructions.

3)Heed all warnings.

4)Follow all instructions.

5)Do not use this apparatus near water.

6)Clean only with dry cloth.

7)Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.

8)Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus

(including amplifiers) that produce heat.

9)Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.

10)Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.

11)The apparatus shall be connected to a MAINS socket outlet with a protective earthing connection.

12)Where the MAINS plug or an appliance coupler is used as the disconnect device, the disconnect device shall remain readily operable.

13)Only use attachments/accessories specified by the manufacturer.

14)Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.

en

15)Unplug this apparatus during lightning storms or when unused for long periods of time.

16)Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

17)CAUTION - These service instructions are for use by qualified service personnel only. To reduce the risk of electric shock do not perform any servicing other than that contained in the operation instructions unless you are qualified to do so.

18)CAUTION! During use, the valves get very hot and high surface temperatures may be reached at the rear of this unit. To avoid burning yourself, make all connections while the unit is still cold.

2

Table of contents

 

IMPORTANT NOTICE!........................................................................

4

Introduction......................................................................................

4

Before you get started........................................................................................................

4

Online registration..............................................................................................................

4

Control elements...............................................................................

5

Front panel.......................................................................................................................

5

Rear panel........................................................................................................................

6

Footswitch........................................................................................................................

6

Inside the BUGERA.............................................................................................................

7

Instructions for qualified service personnel only.....................................................................

7

Wiring the BUGERA...........................................................................

8

Audio connections.............................................................................

9

Specifications..................................................................................

10

Limited warranty............................................................................

11

en

3

IMPORTANT NOTICE!

FAILURE TO OBSERVE THE FOLLOWING POINTS MAY RESULT IN DAMAGE TO THE AMPLIFIER OR LOUDSPEAKERS. DAMAGES CAUSED IN SUCH A WAY ARE NOT COVERED BY WARRANTY.

$$ Before you start, always make sure that your

Bugera Valve Amplifier is connected to a suitable loudspeaker. Observe the correct impedance for your loudspeaker and use the appropriate output socket.

$$ Always use loudspeaker cables for connection between the amplifier and the loudspeaker. Never use other types of cable, like instrument cable or microphone cable.

Switching the amplifier on and off:

$$ Before connecting the amplifier to a power outlet, make sure that both POWER and STANDBY switches are set to the OFF position.

Power on (mandatory):

$$ Switch the POWER switch on—wait for 60 sec- onds—then switch the STANDBY switch on.

Power off (recommended):

$$ Switch the STANDBY switch off—wait for 30 seconds—then switch the POWER switch off.

Note—after powering off we recommend that the amplifier is allowed to cool down for ten minutes before any attempt is made to move the amplifier. This reduces the risk of mechanical damage to the sensitive valve elements.

ATTENTION! TO AVOID DAMAGE TO YOUR !!AMP, NEVER USE THE BUGERA VALVE AM-

PLIFIER WITHOUT A LOUDSPEAKER CONNECTED!

$$ Please ensure proper disposal of all packing materials.

Ensure adequate air supply and to avoid overheating do not place the unit near radiators etc.

$$ Please make sure that all devices are properly grounded. For your own safety, never remove or disable the ground conductors from the devices or on the power cords. The unit must always be connected to the mains outlet with a protective grounding connection.

$$ The tone quality may diminish within the range of powerful radio broadcasting stations and high-frequency sources. Increase the distance between the transmitter and the unit, and use shielded cables for all connections.

Online registration

Please do remember to register your new BUGERA equipment right after your purchase by visiting www.bugeraamps.com and kindly read the terms and conditions of our warranty carefully.

Should your BUGERA product malfunction, our goal is to have it repaired as quickly as possible. To arrange for warranty service, please contact the retailer from whom the equipment was purchased. Should your BUGERA dealer not be located in your vicinity, you may directly contact the BEHRINGER company nearest to you. This contact information is included in the original equipment packaging (Global Contact Information/European Contact Information). Should your country not be listed, please contact our exclusive distributor BEHRINGER

Singapore (BEHRINGER Holdings (Pte) Ltd., 1 Kim Seng Promenade #08-08, Great World City West Tower, Singapore 237994, Tel.: +65 6845 1800, Fax: +65 6214

0275).

Registering your purchase and equipment with us helps us process your repair claims quicker and more efficiently.

Thank you for your cooperation!

en Introduction

Congratulations! By purchasing the BUGERA, you have chosen a state-of-the-art valve amplifier.

This 120-Watt full-valve amp offers you 2 full-fledged channels with 3 tone controls, a separate switchable Effects Loop plus integrated Reverb, a Crunch function on the Clean channel and much more. This way you’re in full control and can get down to the nitty-gritty—your music! Discover the killer sound of the BUGERA and be inspired by its versatility. Whatever style you play, this monster amp gives you the full valve power that you require.

Before you get started

Your product was carefully packed at the factory to ensure safe transport. Nevertheless, if the box is damaged inspect the unit immediately for signs of damage.

$$ If the unit is damaged please do NOT return it to us, but notify your dealer and the shipping company immediately; otherwise, claims for damage or replacement may not be granted.

$$ Always use the original box to prevent damage during storage or transport.

$$ Make sure that children cannot play unsupervised with the unit or its packaging.

CAUTION!

$$ Please note that high volume levels may cause permanent damage to your hearing and/or your loudspeakers. Turn all LEVEL controls to the left before switching on the unit. Be sure to keep the volume at an appropriate level.

4

Introduction

Loading...