B&B Electronics PES1A, PESV1A User Manual

0 (0)

Mini POE Ethernet to

RS-232 Converters

Models: PES1A, PESV1A

Manual Documentation Number: PES1A/PESV1A-2907m

pn# 6868-rev002

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

Manual Documentation Number: PES1A/PESV1A-2907m

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

International Headquarters

B&B Electronics Mfg. Co. Inc.

707 Dayton Road

Ottawa, IL 61350 USA

Phone (815) 433-5100 -- General Fax (815) 433-5105

Website: www.bb-elec.com

Sales e-mail: orders@bb-elec.com -- Fax (815) 433-5109

Technical Support e-mail: support@bb.elec.com -- Fax (815) 433-5104

European Headquarters

B&B Electronics Ltd.

Westlink Commercial Park

Oranmore, Co. Galway, Ireland

Phone +353 91-792444 -- Fax +353 91-792445

Website: www.bb-europe.com

Sales e-mail: sales@bb-europe.com

Technical Support e-mail: support@bb-europe.com

© B&B Electronics – November 2005

Manual Documentation Number: PES1A/PESV1A-2907m

pn# 6868-rev002

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

© 2005 B&B Electronics. No part of this publication may be reproduced or transmitted in any form or by any means, electronic or

mechanical, including photography, recording, or any information storage and retrieval system without written consent. Information in this manual is subject to change without notice, and does not represent a commitment on the part of B&B Electronics.

B&B Electronics shall not be liable for incidental or consequential damages resulting from the furnishing, performance, or use of this manual.

All brand names used in this manual are the registered trademarks of their respective owners. The use of trademarks or other designations in this publication is for reference purposes only and does not constitute an endorsement by the trademark holder.

Manual Documentation Number: PES1A/PESV1A-2907m

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

Table of Contents

 

CHAPTER 1: INTRODUCTION.............................................................................

1

FEATURES..................................................................................................................

1

COMMUNICATION MODES .........................................................................................

2

Direct IP ...............................................................................................................

2

Virtual COM Port .................................................................................................

2

Paired Mode .........................................................................................................

3

Other Communications Modes..............................................................................

3

CHAPTER 2: HARDWARE OVERVIEW .............................................................

5

PACKAGE CHECKLIST ................................................................................................

5

INDICATORS, SWITCHES AND CONNECTORS...............................................................

6

Link Integrity LED (Yellow)..................................................................................

6

Network Activity LED ...........................................................................................

6

Reset Switch ..........................................................................................................

6

Voltage Output Selector Switch (PESV1A only) ...................................................

6

Ethernet Port Connector.......................................................................................

7

Serial Port Connector ...........................................................................................

7

Power Connector ..................................................................................................

7

Output Power Connector (PESV1A only) .............................................................

7

CONNECTING THE HARDWARE ..................................................................................

8

Power over Ethernet (PoE)...................................................................................

8

Configuration Connections ...................................................................................

9

CHAPTER 3: GETTING STARTED ....................................................................

11

1.Check the contents of your PES1A/PESV1A package. It should contain… 11

2.

Set up the Hardware ...................................................................................

11

3.

Power it Up.................................................................................................

11

4.

Get the IP Address ......................................................................................

11

5.

Login ...........................................................................................................

11

6.

Configure the PES1A/PESV1A ...................................................................

12

7.

Set up VCOM (if using the RealPort profile) ..............................................

12

8.

Communicate ..............................................................................................

12

CHAPTER 4: CONFIGURING THE IP ADDRESS............................................

13

USING THE DISCOVERY SOFTWARE .........................................................................

13

Manual Documentation Number: PES1A/PESV1A-2907m

i

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

CHAPTER 5: USING THE WEB CONFIGURATION AND MANAGEMENT

INTERFACE.............................................................................................................

15

 

LOGGING IN .............................................................................................................

15

 

LOGGING OUT .........................................................................................................

15

 

USING TUTORIAL AND HELP....................................................................................

16

 

CONFIGURING NETWORK SETTINGS ........................................................................

16

 

IP Settings ...........................................................................................................

17

 

Network Services Settings ...................................................................................

17

 

Advanced Network Settings.................................................................................

18

 

CONFIGURING THE SERIAL PORT .............................................................................

18

 

Port Profile Settings............................................................................................

18

 

Basic Serial Settings ...........................................................................................

23

 

Advanced Serial Settings.....................................................................................

24

 

CONFIGURING ALARMS AND NOTIFICATION............................................................

24

 

Alarm Notification Settings.................................................................................

24

 

Alarm Conditions................................................................................................

24

 

Alarm Destinations .............................................................................................

25

CHAPTER 6: MANAGING THE PES1A/PESV1A .............................................

27

 

SYSTEM SETTINGS ...................................................................................................

27

 

Device Identity Settings.......................................................................................

27

 

Simple Network Management Protocol (SNMP) Settings...................................

27

 

USING REMOTE MANAGEMENT ...............................................................................

27

 

MANAGING USERS AND PERMISSIONS .....................................................................

27

 

Changing the Root Username and Password .....................................................

28

 

Adding New Users...............................................................................................

28

 

Configuring User Access and Permissions .........................................................

28

 

MANAGING SERIAL PORTS AND CONNECTIONS .......................................................

29

 

Serial Ports .........................................................................................................

29

 

Connections ........................................................................................................

29

CHAPTER 7: USING ADMINISTRATIVE FEATURES ...................................

31

 

FILE MANAGEMENT.................................................................................................

31

 

BACKUP/RESTORE ...................................................................................................

31

 

UPDATE FIRMWARE.................................................................................................

31

 

FACTORY DEFAULT SETTINGS .................................................................................

31

 

SYSTEM INFORMATION ............................................................................................

32

 

General ...............................................................................................................

32

 

GPIO...................................................................................................................

32

 

Serial...................................................................................................................

32

 

Network...............................................................................................................

33

 

REBOOT ...................................................................................................................

34

ii

Manual Documentation Number: PES1A/PESV1A-2907m

 

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com

 

 

B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

 

CHAPTER 8: USING REALPORT.......................................................................

35

Configuring the IP Address.................................................................................

35

Configuring the Serial Port for RealPort............................................................

35

Adding a Virtual COM Port using RealPort.......................................................

36

Removing a Virtual COM Port using RealPort ..................................................

36

Updating RealPort..............................................................................................

37

APPENDIX A: DEFAULT CONFIGURATION SETTINGS ..............................

39

APPENDIX B: PRODUCT SPECIFICATIONS ..................................................

41

APPENDIX C: DIMENSIONAL DIAGRAMS.....................................................

43

APPENDIX D: RS-232 CONNECTIONS..............................................................

45

APPENDIX E: NETWORK CONNECTIONS .....................................................

47

APPENDIX F: POWER OVER ETHERNET (POE)...........................................

49

Manual Documentation Number: PES1A/PESV1A-2907m

iii

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

Manual Documentation Number: PES1A/PESV1A-2907m

iv

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

Introduction

Chapter 1: Introduction

PES1A and PESV1A Mini PoE (Power over Ethernet) Ethernet to RS232 Converters provide simple and cost-effective solutions for connecting RS-232 devices to Ethernet networks. PES1A and PESV1A converters make it easy to connect serial printers, copiers, building automation, retail, point of sale, warehousing and banking equipment directly into Ethernet networks. Both models feature Power over Ethernet (PoE) operation and the PESV1A provides a switch selectable voltage output to power external devices.

PES1A and PESV1A converters support virtual COM port, console management, TCP and UDP socket, serial bridge, terminal, modem emulation and custom connections. Network addresses can be obtained dynamically or manually. Simple Network Management Protocol (SNMP) is supported. Configuration is accomplished through a web-based user interface.

Figure 1. PES1A Mini POE Ethernet to RS-232 Converter

Features

Converts Ethernet to RS-232 serial

Small, economical and configurable

PESV1A provides selectable output power supply

Supports TD, RD, TRS, CTS, DTR, DCD, DSR and GND RS-232 lines

LEDs indicate link integrity and data transfer activity

Manual Documentation Number: PES1A/PESV1A-2907m

1

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

Introduction

10/100 Mbps auto-detecting operation

IEEE 802.3af (Power over Ethernet) compatible

Web Configuration and Management user interface

Email event notification

Communication Modes

PES1A/PESV1A Ethernet to RS-232 converters allow you to connect serial devices over a LAN or WAN. Serial devices no longer are limited to a physical connection to the PC COM port. They can be installed anywhere on the LAN using TCP/IP or UDP/IP communications. This allows traditional Windows PC software access to serial devices anywhere on the LAN/WAN network.

Direct IP

Direct IP Mode allows applications using TCP/IP or UDP/IP socket programs to communicate with the asynchronous serial ports on the serial server. In this mode the PES1A/PESV1A is configured as a TCP or UDP server. The socket program running on the PC establishes a communication connection. The data is sent directly to and from the serial port on the server.

TCP Server Mode allows network devices to initiate a TCP connection to the serial device connected to the serial port on the PES1A/PESV1A. This is also referred to as reverse telnet.

UDP Server Mode allows network devices to initiate a UDP connection to the serial device attached to the serial port of the PES1A/PESV1A. When using UDP protocol the PES1A/PESV1A can be configured to broadcast data to and receive data from multiple IP addresses.

Virtual COM Port

Virtual COM Port mode (also called RealPort, or com port redirection) allows you to map a COM port on your PC to the serial port on your PES1A/PESV1A. Using the RealPort software (included with the PES1A/PESV1A) you create virtual COM ports on your PC. When your application sends data to this port, RealPort redirects the data across the network to serial device connected to the PES1A/PESV1A serial port. The network is transparent to the user application and the serial device connected to the PES1A/PESV1A.

2

Manual Documentation Number: PES1A/PESV1A-2907m

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

Introduction

Paired Mode

Paired Mode (also called Serial Tunneling or Serial Bridge mode) allows serial devices connected to two PES1A/PESV1A converters to communicate across a network. The two PES1A/PESV1A converters automatically connect to each other.

In Paired Mode the heartbeat feature ensures reliable communications by restoring the connection if communications are temporarily lost at either end due to loss of power or Ethernet connection.

Other Communications Modes

PES1A/PESV1A Converters also feature the following communications profiles:

Terminal Mode allows you to connect a PC running terminal software to the PES1A/PESV1A serial port and communicate with the PES1A/PESV1A via a command line interface.

Modem Emulation Mode allows you to configure the serial port to operate as if it is a modem. For legacy applications where a serial device is set up to communicate through a modem, the serial device can now be connected to the PES1A/PESV1A and communication occurs over the network. The PES1A/PESV1A emulates modem responses to and from the serial device.

In Console Management Mode the PES1A/PESV1A can be configured for connection to the management port typically found on network devices such as routers, switches and servers. This allows remote management of the network device. Communication can be accomplished using telnet to a specific port in the converter.

Custom Mode allows you to custom configure the PES1A/PESV1A serial port and is used if your application does not fit into any other predefined modes.

Manual Documentation Number: PES1A/PESV1A-2907m

3

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

Introduction

4

Manual Documentation Number: PES1A/PESV1A-2907m

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

B&B Electronics PES1A, PESV1A User Manual

Hardware Overview

Chapter 2: Hardware Overview

Package Checklist

PES1A/PESV1A PoE Ethernet to RS-232 Converters are shipped with the following items included:

9The PES1A or PESV1A module

9A printed version of this user manual

9A printed version of the PES1A/PESV1A Quick Start Guide

9CD-ROM disc with

o B&B discovery software

o RealPort drivers for Windows 98/ME/2000/XP/NT 4.0/Vista o this manual in pdf format

o a Quick Start guide in pdf format

Figure 2. Top View of the PES1A Converter

Figure 3. Top View of the PESV1A Converter

Manual Documentation Number: PES1A/PESV1A-2907m

5

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

Hardware Overview

Indicators, Switches and Connectors

Link Integrity LED (Yellow)

When the yellow LED located on the Ethernet jack is illuminated it indicates that a connection (link integrity) has been established between the converter and a node on the network.

Network Activity LED

When the green LED located on the Ethernet jack is flashing it indicates data is being sent across the network.

Figure 4. LED Indicators on the PES1A

Reset Switch

The Reset switch is a recessed switch located on the RJ-45 end of the PES1A and on the side of the PESV1A. The Reset switch provides two functions:

Press and release within 10 seconds

Resets the PES1A/PESV1A

Press and hold for more than 10 seconds

Reloads factory default values

while powering up

 

Voltage Output Selector Switch (PESV1A only)

A three-position slide switch located on the side of the PESV1A allows you to select the voltage output (available on the two position terminal block). The three voltages available are:

5 VDC

9 VDC

12 VDC

6

Manual Documentation Number: PES1A/PESV1A-2907m

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

Hardware Overview

Ethernet Port Connector

The Ethernet Port connector is a standard RJ-45 receptacle that allows the serial server to be connected to an Ethernet network. It also carries Power over Ethernet (PoE) based on the IEEE 802.3af standard.

On the PES1A/ PESV1A two indicator LEDs are built into the RJ-45 connector.

Serial Port Connector

The Serial Port Connector is a DB-9 male connector (configured as a DTE) supporting RS-232 serial communications including TD, RD, TRS, CTS, DTR, DCD, DSR and GND signal lines. Use a standard serial cable if connecting to a DCE; use a null modem (crossover) cable if connecting to a DTE.

Refer to Appendices D, E and F for connection pin-outs.

Power Connector

Power is supplied to the PES1A/PESV1A by PoE (Power over Ethernet) via the RJ-45 Ethernet receptacle. Power over Ethernet may be delivered via unused pairs in the CAT-5 cable, or via a simplexed power technique. Both options are supported by the PES1A and PESV1A. PoE power consumption for the PES1A and PESV1A are rated Class 3.

Refer to Appendix E for Ethernet connection pin-outs and additional information on PoE.

Output Power Connector (PESV1A only)

The output power connector (on the PESV1A only) is a two position removable terminal block that provides a DC power supply voltage output (derived from the PoE input power) in three selectable ranges: 5 VDC, 9 VDC and 12 VDC. Maximum output power is 4 watts.

Figure 5. Side View of the PESV1A

Manual Documentation Number: PES1A/PESV1A-2907m

7

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

Hardware Overview

Connecting the Hardware

Typically, the PES1A/PESV1A is connected to a network via a hub, switch or router using standard CAT-5 cable. Power must be supplied to the converter via the CAT-5 cable using Power over Ethernet. Configuration is accomplished over the network, or via a direct connection (see below) using the Web Configuration and Management Interface

Power over Ethernet (PoE)

Power is supplied to your PES1A/PESV1A from PoE power source equipment (PSE), which must be installed within 100 meters of the converter. PSEs may be endspan or midspan devices. Endspan PSE devices may be switches or hubs with integrated PoE capability. Midspan PSE devices are dedicated, inline devices that are installed between your network switch and the PES1A/PESV1A.

For more information on PoE see Appendix C.

Endspan PoE

Switch or Hub*

 

 

Serial Cable

PC

PES1A

Serial Device

 

or

 

PC

 

PESV1A

 

 

 

* Must be w ithin 100 ft of the PES1A/PESV1A

Figure 6. Connection using Endspan Power Source

8

Manual Documentation Number: PES1A/PESV1A-2907m

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

Loading...