Certified for US EPA-Tier 2 / Constant Speed |
|
|
|
||
Standard Model [1000kWe/60Hz] |
|
|
MITSUBISHI |
||
S12H-Y2PTAW-1 |
SPECIFICATION SHEET |
|
DIESEL ENGINES |
||
GENERAL ENGINE DATA |
|
|
|
|
|
Type |
|
|
4-Cycle, Water Cooled |
|
|
Aspiration |
|
|
Turbo-Charged, Inter Cooler |
||
|
|
|
(Fresh water to Cooler) |
||
Cylinder Arragement |
|
|
|
60oV |
|
No.of Cylinders |
|
|
|
12 |
|
Bore mm(in.) |
|
|
|
150 |
(5.91) |
Stroke mm(in.) |
|
|
|
175 |
(6.89) |
Displacement liter(in3) |
|
|
|
37.11 |
(2265) |
Compression Ratio |
|
|
|
14.5:1 |
|
Dry Weight - Engine only - kg(lb) |
|
|
|
4300 |
(9482) |
Wet Weight - Engine only - kg(lb) |
|
|
|
4560 |
(10055) |
PERFORMANCE DATA |
|
|
|
|
|
Steady State Speed Stability Band at any Constant Load |
|
|
|
||
Electric Governor - % |
|
|
|
±0.25 or better |
|
Maximum Overspeed Capacity - rpm |
|
|
2000 |
|
|
Moment of inertia of Rotating Components - kgf m2(lbf ft2) |
|
55.6 |
(1319.6) |
||
(Includes Std.Flywheel) |
|
|
|
|
|
Cyclic Speed Variation with Flywheel at 1800rpm |
|
1/523 |
|
||
ENGINE MOUNTING |
|
|
|
|
|
Maximum Bending Moment at Rear Face of Flywheel Housing - kgf m(lbf ft) |
200 |
(1446.9) |
|||
AIR INLET SYSTEM |
|
|
|
|
|
Maximum Intake Air Restriction (Includes piping) |
|
|
|
||
With Clean Filter Element - mm H 2O (in.H2O) |
|
400 |
(15.7) |
||
With Dirty Filter Element - mm H2O (in.H2O) |
|
635 |
(25.0) |
||
EXHAUST SYSTEM |
|
|
|
|
|
Maximum Allowable Back Pressure - mm H2O (in.H2O) |
|
600 |
(23.6) |
||
LUBRICATION SYSTEM |
|
|
|
|
|
Oil Pressure at ldle - kgf/cm2(psi) |
|
|
|
2 3 |
(29 43) |
at Rate Speed - kgf/cm2(psi) |
|
|
5 6 |
(71 86) |
|
Maximum Oil Temperature - oC(oF) |
|
|
|
110 |
230 |
Oil Capacity of Standard Pan |
High |
- liter (U.S.gal) |
|
180 |
(48) |
|
Low |
- liter (U.S.gal) |
|
150 |
(39.6) |
Total System Capacity (lncludes Oil Filter) - liter (U.S.gal) |
|
200 |
(52.8) |
||
Maximum Angle of lnstallation (Std. Pan) |
Front Down |
|
9.5o |
|
|
(Engine Only) |
|
Front Up |
|
11o |
|
COOLING SYSTEM |
|
Side to Side |
|
22.5o |
|
|
|
|
|
|
|
Coolant Capacity of Jacket (Engine only) - liter (U.S.gal) |
|
83 |
(21.9) |
||
Coolant Capacity of Air cooler (Engine only) - liter (U.S.gal) |
|
17 |
(4.5) |
||
Maximum External Friction Head at Engine Outlet - kgf/cm 2(psi) |
|
|
|
||
(For Jacket and Air Cooler) |
|
|
|
0.35 |
(5.0) |
Maximum Static Head of Coolant above Crankshaft Center - m(ft) |
|
10 |
(32.8) |
||
Standard Thermostat (modulating)Range of Jacket - oC(oF) |
|
71 85 |
(160 185) |
||
Standard Thermostat (modulating)Range of Air Cooler - oC(oF) |
|
35 50 |
(95 122) |
||
Maximum Coolant Temperature at Engine Outlet of Jacket - oC(oF) |
|
98 |
(208) |
||
Minimum Coolant Expansion Space - % of System Capacity |
|
|
|
||
(For Jacket and Air Cooler) |
|
|
|
10 |
(0.4) |
Maximum Coolant Temperature at Intercooler lnlet, PTAW type - oC(oF) |
|
45 |
(113) |
||
Maximum Air Restriction on Discharge Side of Radiator and Fan - mm H 2O(in.H2O) |
10 |
(0.4) |
APPLICATION : GENERATOR
Pub. No. T13-0633-E
Dec. '06 Printed in Japan