AT29C010A

Features

Fast Read Access Time - 70 ns

5-Volt-Only Reprogramming

Sector Program Operation

Single Cycle Reprogram (Erase and Program) 1024 Sectors (128 bytes/sector)

Internal Address and Data Latches for 128-Bytes

Two 8 KB Boot Blocks with Lockout

Internal Program Control and Timer

Hardware and Software Data Protection

Fast Sector Program Cycle Time - 10 ms

DATA Polling for End of Program Detection

Low Power Dissipation

50 mA Active Current

μ

Typical Endurance > 10,000 Cycles

Single 5V ±10% Supply

CMOS and TTL Compatible Inputs and Outputs

Commercial and Industrial Temperature Ranges100 A CMOS Standby Current

Description

The AT29C010A is a 5-volt-only in-system Flash programmable and erasable read only memory (PEROM). Its 1 megabit of memory is organized as 131,072 words by 8 bits. Manufactured with Atmel’s advanced nonvolatile CMOS technology, the device offers access times to 70 ns with power dissipation of just 275 mW over the commercial temperature range. When the device is deselected, the CMOS standby current is less than 100 μA. The device endurance is such that any sector can typically be written to in excess of 10,000 times.

To allow for simple in-system reprogrammability, the AT29C010A does not require high input voltages for programming. Five-volt-only commands determine the opera-

Pin Configurations

DIP Top View

 

 

 

 

(continued)

 

Pin Name

Function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A0 - A16

Addresses

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CE

Chip Enable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OE

Output Enable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WE

Write Enable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I/O0 - I/O7

Data Inputs/Outputs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NC

No Connect

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PLCC Top View

TSOP Top View

Type 1

1 Megabit

(128K x 8)

5-volt Only CMOS Flash Memory

0394B

4-129

Description (Continued)

tion of the device. Reading data out of the device is similar to reading from an EPROM. Reprogramming the AT29C010A is performed on a sector basis; 128-bytes of data are loaded into the device and then simultaneously programmed.

During a reprogram cycle, the address locations and 128bytes of data are internally latched, freeing the address

Block Diagram

Device Operation

READ: The AT29C010A is accessed like an EPROM. When CE and OE are low and WE is high, the data stored at the memory location determined by the address pins is asserted on the outputs. The outputs are put in the high impedance state whenever CE or OE is high. This dualline control gives designers flexibility in preventing bus contention.

BYTE LOAD: Byte loads are used to enter the 128bytes of a sector to be programmed or the software codes for data protection. A byte load is performed by applying a low pulse on the WE or CE input with CE or WE low (respectively) and OE high. The address is latched on the falling edge of CE or WE, whichever occurs last. The data is latched by the first rising edge of CE or WE.

PROGRAM: The device is reprogrammed on a sector basis. If a byte of data within a sector is to be changed, data for the entire sector must be loaded into the device. The data in any byte that is not loaded during the programming of its sector will be indeterminate. Once the bytes of a sector are loaded into the device, they are simultaneously programmed during the internal programming period. After the first data byte has been loaded into the device, successive bytes are entered in the same manner. Each new byte to be programmed must have its high to low transition on WE (or CE) within 150 μs of the low to high transition of WE (or CE) of the preceding byte. If a high to low transition is not detected within 150 μs of the last low to high transition, the load period will end and the internal programming period will start. A7 to A16 specify the sector address. The sector address must be valid during each high to low transition of WE (or CE). A0 to A6 specify the byte address within the sector. The bytes may

4-130 AT29C010A

and data bus for other operations. Following the initiation of a program cycle, the device will automatically erase the sector and then program the latched data using an internal control timer. The end of a program cycle can be detected by DATA polling of I/O7. Once the end of a program cycle has been detected, a new access for a read or program can begin.

be loaded in any order; sequential loading is not required. Once a programming operation has been initiated, and for the duration of tWC, a read operation will effectively be a polling operation.

SOFTWARE DATA PROTECTION: A software controlled data protection feature is available on the AT29C010A. Once the software protection is enabled a software algorithm must be issued to the device before a program may be performed. The software protection feature may be enabled or disabled by the user; when shipped from Atmel, the software data protection feature is disabled. To enable the software data protection, a series of three program commands to specific addresses with specific data must be performed. After the software data protection is enabled the same three program commands must begin each program cycle in order for the programs to occur. All software program commands must obey the sector program timing specifications. Once set, the software data protection feature remains active unless its disable command is issued. Power transitions will not reset the software data protection feature, however the software feature will guard against inadvertent program cycles during power transitions.

Once set, software data protection will remain active unless the disable command sequence is issued.

After setting SDP, any attempt to write to the device without the 3-byte command sequence will start the internal write timers. No data will be written to the device; however, for the duration of tWC, a read operation will effectively be a polling operation.

(continued)

Device Operation (Continued)

After the software data protection’s 3-byte command code is given, a byte load is performed by applying a low pulse on the WE or CE input with CE or WE low (respectively) and OE high. The address is latched on the falling edge of CE or WE, whichever occurs last. The data is latched by the first rising edge of CE or WE. The 128-bytes of data must be loaded into each sector by the same procedure as outlined in the program section under device operation.

HARDWARE DATA PROTECTION: Hardware features protect against inadvertent programs to the AT29C010A in the following ways: (a) VCC sense— if V CC is below 3.8V (typical), the program function is inhibited. (b) VCC power on delay— once V CC has reached the VCC sense level, the device will automatically time out 5 ms (typical) before programming. (c) Program inhibit— holding any one of OE low, CE high or WE high inhibits program cycles. (d) Noise filter— pulses of less than 15 ns (typical) on the WE or CE inputs will not initiate a program cycle.

PRODUCT IDENTIFICATION: The product identification mode identifies the device and manufacturer as Atmel. It may be accessed by hardware or software operation. The hardware operation mode can be used by an external programmer to identify the correct programming algorithm for the Atmel product. In addition, users may wish to use the software product identification mode to identify the part (i.e. using the device code), and have the system software use the appropriate sector size for program operations. In this manner, the user can have a common board design for 256K to 4-megabit densities and, with each density’s sector size in a memory map, have the system software apply the appropriate sector size.

For details, see Operating Modes (for hardware operation) or Software Product Identification. The manufacturer and device code is the same for both modes.

DATA POLLING: The AT29C010A features DATA polling to indicate the end of a program cycle. During a program cycle an attempted read of the last byte loaded will

Absolute Maximum Ratings*

Temperature Under Bias

................. -55°C to +125°C

Storage Temperature......................

-65°C to +150°C

All Input Voltages

 

(including NC Pins)

 

with Respect to Ground ...................

-0.6V to +6.25V

All Output Voltages

 

with Respect to Ground .............

- 0.6V to VCC + 0.6V

 

 

 

 

Voltage on OE

 

with Respect to Ground ...................

-0.6V to +13.5V

 

 

 

 

AT29C010A

result in the complement of the loaded data on I/O7. Once the program cycle has been completed, true data is valid on all outputs and the next cycle may begin. DATA polling may begin at any time during the program cycle.

TOGGLE BIT: I n a d d i t i o n t o DATA p o l li ng t he AT29C010A provides another method for determining the end of a program or erase cycle. During a program or erase operation, successive attempts to read data from the device will result in I/O6 toggling between one and zero. Once the program cycle has completed, I/O6 will stop toggling and valid data will be read. Examining the toggle bit may begin at any time during a program cycle.

OPTIONAL CHIP ERASE MODE: The entire device can be erased by using a 6-byte software code. Please see Software Chip Erase application note for details.

BOOT BLOCK PROGRAMMING LOCKOUT: The AT29C010A has two designated memory blocks that have a programming lockout feature. This feature prevents programming of data in the designated block once the feature has been enabled. Each of these blocks consists of 8K bytes; the programming lockout feature can be set independently for either block. While the lockout feature does not have to be activated, it can be activated for either or both blocks.

These two 8K memory sections are referred to as boot blocks. Secure code which will bring up a system can be contained in a boot block. The AT29C010A blocks are located in the first 8K bytes of memory and the last 8K bytes of memory. The boot block programming lockout feature can therefore support systems that boot from the lower addresses of memory or the higher addresses. Once the programming lockout feature has been activated, the data in that block can no longer be erased or programmed; data in other memory locations can still be changed through the regular programming methods. To activate the lockout feature, a series of seven program commands to specific addresses with specific data must be performed. Please see Boot Block Lockout Feature Enable Algorithm.

If the boot block lockout feature has been activated on either block, the chip erase function will be disabled.

(continued)

*NOTICE: Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.

4-131

Device Operation (Continued)

BOOT BLOCK LOCKOUT DETECTION: A software method is available to determine whether programming of either boot block section is locked out. See Software Product Identification Entry and Exit sections. When the device is in the software product identification mode, a read from location 00002 will show if programming the lower address boot block is locked out while reading location FFFF2 will

do so for the upper boot block. If the data is FE, the corresponding block can be programmed; if the data is FF, the program lockout feature has been activated and the corresponding block cannot be programmed. The software product identification exit mode should be used to return to standard operation.

DC and AC Operating Range

 

 

 

 

 

 

AT29C010A-70

AT29C010A-90

 

 

AT29C010A-12

AT29C010A-15

Operating

 

Com.

 

0°C - 70°C

 

 

0°C - 70°C

 

 

0°C - 70°C

 

0°C - 70°C

Temperature (Case)

Ind.

 

 

 

 

 

 

 

 

 

-40°C - 85°C

 

 

-40°C - 85°C

 

-40°C - 85°C

VCC Power Supply

 

 

 

 

 

5V ± 5%

 

 

5V ± 10%

 

 

5V ± 10%

 

5V ± 10%

Operating Modes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mode

 

 

CE

 

 

OE

WE

 

 

Ai

I/O

 

 

Read

 

 

VIL

 

 

VIL

VIH

 

 

Ai

DOUT

 

Program (2)

 

VIL

 

VIH

VIL

 

 

Ai

DIN

 

 

5V Chip Erase

 

VIL

 

VIH

VIL

 

 

Ai

 

 

 

Standby/Write Inhibit

VIH

 

 

X (1)

X

 

 

X

 

High Z

 

Program Inhibit

 

X

 

 

X

VIH

 

 

 

 

 

 

 

 

Program Inhibit

 

X

 

 

VIL

X

 

 

 

 

 

 

 

 

Output Disable

 

X

 

VIH

X

 

 

 

 

 

High Z

 

Product Identification

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A1 - A16 = V

IL

, A9 = V , (3)

Manufacturer Code (4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

Hardware

 

VIL

 

 

VIL

VIH

 

A0 = VIL

 

 

 

 

 

 

 

A1 - A16 = V

IL

, A9 = V , (3)

Device Code (4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A0 = VIH

 

 

 

Software (5)

 

 

 

 

 

 

 

 

 

 

 

 

 

A0 = VIL

Manufacturer Code (4)

 

 

 

 

 

 

 

 

 

 

 

 

 

A0 = VIH

Device Code (4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes: 1. X can be VIL or VIH.

 

 

 

 

 

 

 

 

4. Manufacturer Code: 1F, Device Code: D5

 

2. Refer to AC Programming Waveforms.

 

 

5. See details under Software Product Identification Entry/Exit.

3. VH = 12.0V ± 0.5V.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC Characteristics

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Symbol

Parameter

 

 

 

 

 

 

 

Condition

 

 

 

 

Min

 

Max

Units

ILI

 

Input Load Current

 

 

VIN = 0V to VCC

 

 

 

 

10

μA

ILO

 

Output Leakage Current

 

 

 

VI/O = 0V to VCC

 

 

 

 

10

μA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Com.

 

100

μA

ISB1

 

VCC Standby Current CMOS

 

 

CE = VCC - 0.3V to VCC

 

 

 

 

Ind.

 

300

μA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ISB2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VCC Standby Current TTL

 

 

 

CE = 2.0V to VCC

 

 

 

 

3

mA

ICC

 

VCC Active Current

 

 

f = 5 MHz; IOUT = 0 mA

 

 

 

 

50

mA

VIL

 

Input Low Voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.8

V

VIH

 

Input High Voltage

 

 

 

 

 

 

 

 

 

 

 

 

2.0

 

 

V

VOL

 

Output Low Voltage

 

 

 

IOL = 2.1 mA

 

 

 

 

 

 

.45

V

VOH1

 

Output High Voltage

 

 

IOH = -400 μA

 

 

2.4

 

 

V

VOH2

 

Output High Voltage CMOS

 

 

 

IOH = -100 μA; VCC = 4.5V

 

 

4.2

 

 

V

4-132 AT29C010A