Atec Guardian-6000 User Manual

0 (0)
Atec Guardian-6000 User Manual

Guardian

USES:

Production and Compliance Testing of Appliances, Instruments and Information Technology Equipment in Accordance with UL, CSA, IEC, TUV and Other Standards such as EN60335, EN60950, EN61010, CSA C22.2 No. 1010.1, UL3111 and UL1950

Transformer Electrical Safety Testing

Electric Motor Safety Testing

Power Supply Safety Testing

Verification of the Ground Connection on Products with a Three Prong Power Cord

FEATURES:

Programmable output voltage to 5KV AC and 6KV DC

Ground Bond Testing to 30A AC with Adjustable Limit

Insulation Resistance Measurements from 100kto 50G

Programmable Ramp and Test Times

Storage of 99 Tests Setups with 99 Steps per Setup

Continuous Leakage Current Monitoring

Trip Current Programmable to 40mA AC and 20mA DC

Front Panel Lockout via Password

Standard IEEE and Remote Control Interfaces

Optional RS232, Printer Interfaces

Built-in 8 Channel Scanner Option

6000 Series

Electrical Safety Analyzer

Introduction

The Guardian 6000 is four instruments in one providing AC Hipot, DC Hipot, Insulation Resistance and Ground Bond measurements from a single test connector in one versatile instrument. This provides a cost effective solution to electrical safety compliance testing with maximum flexibility for present and future requirements. Performing multiple electrical safety tests in one unit can reduce test time, increase productivity and reduce the number of instruments requiring calibration.

Description

The Guardian 6000 AC Hipot Tester performs AC dielectric testing (hipot)over the voltage range from 50V to 5000VAC RMS. The maximum leakage current of 40mA RMS makes the Guardian 6000 ideal for testing devices with high leakage currents such as power supplies which have large filter or “Y” capacitors for noise reduction.

The Guardian 6000 DC Hipot Tester voltage range for DC dielectric testing is 50V to 6000VDC with a resolution of 1V. The maximum current leakage is 20mA which allows quick charging of capacitive devices. A quick discharge of the device when the measurement is complete, also minimizes test times. Leakage currents can be monitored down to 0.1µA.

The Guardian 6000 Insulation Resistance measurements are similar to a DC hipot but rather than displaying leakage current, resistance is calculated and displayed. The insulation resistance can be measured over the range of 100kto 50Gwith test voltages from 50VDC to 1000VDC in 1V steps.

The Guardian 6000 Ground Bond provides up to 30AAC for ground bond testing. The test current can be programmed from 1A to 30A in 0.1A steps. Hi current limit, test time, frequency and open circuit no load voltage can all be programmed. The offset feature can automatically compensate for any lead resistance.

For more detailed

specifications, visit

www.quadtech.com

For more information about special purchase, rent & lease options, call

1-800-253-1230 Fax 1-978-461-4295 Intl. 1-978-461-2100

HIPOT TESTERS • LCR METERS • MEGOHMMETERS • MILLIOHMMETERS • CABLE TESTERS

Loading...
+ 1 hidden pages