Ariston MARCO POLO Gi7S 11L FFI User Manual [ru]

0 (0)

PANTONE Warm Red C

АРІСТОН ТЕРМО УКРАЇНА

вул.Боженко 86 Е Київ, 03680, Україна Тел: +38 044 496 25 18

E?mail: info.ua@aristonthermo.com www.ariston.com/ua

Аристон Термо Русь

Россия, 127015, Москва, ул. Большая Новодмитровская, 14, стр.1, офис 626

Тел. +7 (495) 213 03 00, 213 03 01 Горячая линия Аристон +7 (495) 777 33 00 E?mail: service.ru@aristonthermo.com www.ariston.com/ru

GB Domestic gas instantaneous water heater

UA Інструкція з установки та технічного обслуговування

RU Водонагреватель газовый проточный бытовой Руководство по эксплуатации

Gi7S 11 / 16L

Marco Polo Gi7S 11L FFI

Marco Polo Gi7S 16L FFI

420010495001

Dear user,

Thank you for purchasing our ARISTON gas water heater. The product is the latest domestic gas water instantaneous.

We believe that ARISTON water heater can satisfy all your requirements because ARISTON series are results of high technology, high quality and rich experience. Therefore ARISTON series have gained continuous trusts from families around the world.

We recommend that you should carefully read this manual to acquire convenience and benefits from ARISTON water heater. Please carefully keep the manual for consultation by you and operators of installation and service.

Contents

Functions and features………………………………………………………………3

Parts……………………………………………………………………………………4

Pre-operation preparations …………………………………………………………6

Handle …………………………………………………………………………………7

Operation attentions…………………………………………………………………10

Anti-freezing attentions ……………………………………………………………11

Installation ……………………………………………………………………………12

Judgment and countermeasures for errors and abnormalities …………………16 Specification list………………………………………………………………………17 Wiring diagram ………………………………………………………………………18

1

2

I. Functions and features

1. Dashing profile

Treat the surface with several hi-tech finishing technologies. Match various designs of modern kitchens. Proud compact structure and small body. Greatly save the installation space.

2. Intelligent wide-extent constant temperature

The micro-computer surveils temperature and water flux, in combine with proportional valve to keep the temperature of out-let water stable

3. Intelligent 3 sections combustion

The micro-computer will choose the most suitable burning section based on the signals from the water flow sensor and water temperature sensor.

4. Obturation combustion and high-efficiency heat-exchange

With rear air inlet structure, and wind supply by the fan beneath, we make safer combustion; the TP2 material serves you with higher efficiency.

5. Intelligent bath mode

Humanized program specially designed for bathtub and alike water filling demands. The micro-computer controls the temperature and the flux in this mode, it’ll buzz to remind you when the

water volume reaches your setting. The machine switches to former mode and standby after user shut down the water.plus the machine

6.LCD display

The luxurious LCD shows many parametes as temperature and flux, and modes, operate with mechanical keys, facile to operate. And it shows error codes as well, which is pratical for maintenance.

7. Multi-protections for safer operation

●Automatic flameout protection: Water heater cuts off gas supply automatically if there’s accidental flameout during working so as to avoid gas leakage and ensure safety and reliability.

●Timeout protection

Gas supply is automatically shut off and the burner is extinguished after continuous use for 45±3min. If further use is required, please turn off the water valve, then re-open it several seconds later. By then re-ignition will be available.

●Air-blast combustion design: Exhaust all fume to outdoor with certified DC stepless fan for safe operation. ●In addition it has overheat protection, over-pressure relief, anti-freeze protection, fan stop prevention,

dry heating prevention and flue pipe blockage prevention to ensure water heater running in normal condition.

II. Parts

2.1 Outline

Warning lable

Tech label

Control panel

 

Water inlet

Water outlet

Filter

 

safety valve

Power supply cable

Gas inlet

 

2.2Internal structure a. Gi7S 11L FFI

front cover

supporter

 

exhaust cover

back cover

 

over-heat device

heat-exchanger

PCB

ignition pin

fan

combustion chamber

 

control panel

flame sensor

ignitor

 

temperature sensor

gas colletor

 

 

water flow sensor

water outlet

 

 

water inlet

transformer

gas valve

 

gas inlet

3

4

 

Ariston MARCO POLO Gi7S 11L FFI User Manual

b. Gi7S 16L FFI

front cover

supporter

exhaust cover

back cover

over-heat device

heat-exchanger

PCB

ignition pin

 

fan

combustion chamber

control panel

flame sensor

temperature sensor

ignitor

gas colletor

 

 

water flow sensor

water outlet

 

 

water inlet

transformer

gas valve

 

 

gas inlet

2.3 Control panel (main controller)

Display

Hot water flowrate setting button

* Water-out temperature indication (e.g. 88)

* Press down hot-water flowrate setting button to enter flowrate

setting mode. At that time interface indicates 000L. Press down

* Water out flowrate setting indication (e.g. 100L)

temperature UP/DOWN button to adjust hot water flowrate

* Error code indication: Blinking display error code if any fault

(flowrate unit is 10L).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temperature/flowrate setting button

Power supply button

* To set hot-water temperature, stepless in low range 35~48, stepping

* Please press down the button once for initial use. Keep the

in high range 50, 55, 60, 65 and 70.

standby condition for normal use.

*To set water-out flowrate in water-in flowrate setting mode.

Standard mode: the default mode when first power on is the standard mode, if the water pressure is high enough, it’ll achieve the set temperature by gas modulation, if the highest heat-input failed to gain that temperature, the water flow will then be reduced.

5

III. Pre-operation preparations

Please refer to the following steps during initial use.

1 Please turn the water-in knob to the largest extent.

3 Please plug the power cable into the socket or turn on the power distribution box.

2 Open the hot-water faucet to check water flow-out then close

the faucet.

4 Please turn the gas valve to the largest extent.

Warning

•Please don’t spray the bursting hot water to human body or head when using sprinkler, before doing that you should check with hands to make sure the water temperature is proper.

•In order to prevent scald, please confirm the hot water temperature with hand before enjoying bath/shower in case that the machine just produced hot water a moment ago, because there’s hot water retained in the pipe.

• No people except for the user is allowed to change the temperature setting arbitrarily, the sudden spurt of hot water may cause scald, while it doesn’t feel good if water temperature suddenly turns cold.

6

. Handle

4.1 Hot-water output

●Press the power button on the control panel to turn the LCD on. The screen flashes to show 42 for 3 seconds (Default temperature setting).

●Open the hot-water faucet, the burner inflames automatically and hot water flows out. (For the first running, open and close the hot-water faucet repeatedly till water heater inflames, to discharge air residue in the gas pipe.)

●The faucet is recommended to be turned to large extent. Otherwise ignition may be unavailable, or it may be flameout during the cold-water mixing process.

●The water heater adopts new safe and gas-saving technology. Gas will be cut off automatically after water heater works for 45±3min without interruption. Then burner is extinguished. If more service is required, just close the faucet for several seconds and restart, re-ignition will be available then.

7

4.2 Water temperature adjustment

●If both control panel and wireless remote controller are connected with water heater, please confirm if priority indication lamp is on.

 

 

If priority indication on

●Control panel is given priority. It’s allowed to

 

 

the control panel turns

start/stop water heater, adjust the water

 

 

bright

temperature, set water flux and etc.

 

 

 

●Remote controller is given priority. Therefore

 

 

If priority indication on

temperature adjustment is not available for the

 

 

control panel. User can only read the

 

 

the control panel does

temperature, however, on/off button still works.

 

 

not turn bright

●Start/stop the water heater with on/off button

Adjustment by

 

 

to get the priority. Then priority indication turns

 

 

bright.

control panel

 

 

 

 

 

 

●Remote controller is given priority. Water

 

 

If priority indication on

temperature adjustment is locked at this time,

 

 

because hot water is being used. User can only

 

 

the control panel turns

read the temperature, however, water flux

 

 

flashing

setting still works.

 

 

 

●In such case it is impossible for the control

 

 

 

panel to get priority. On/off button is invalid.

 

 

 

 

 

 

 

●Remote controller is given priority. It’s allowed

 

 

If priority indication on

to start/stop water heater, adjust the water

 

 

temperature, set water flux and etc.

 

 

the wireless remote

●If hot water is not working, tap the priority

 

 

controller turns bright

button then the priority icon disappears.

 

 

 

Meanwhile control panel is given priority.

 

 

 

 

 

 

 

●Control panel or other remote controller is

 

 

If priority indication on

given priority. Adjustment buttons are locked,

 

 

user can only read the temperature. And other

Adjustment by

 

the wireless remote

function buttons are invalid, too. On/off button

wireless remote

 

controller does not

can only start or stop remote controller but not

controller

 

turn bright

water heater.

 

●Tap the priority button to get priority. Start

 

 

 

setting and/or adjustment till priority icon

 

 

 

shows up.

 

 

 

 

 

 

 

●Control panel or other remote controller (if

 

 

 

more than one remote controllers are mounted)

 

 

If priority indication on

is given priority. Adjustment buttons are locked

 

 

because hot water is working. At this time, user

 

 

the wireless remote

can only read the temperature. And other

 

 

controller flashes

functions are unavailable, too. On/off button

 

 

 

can only start or stop remote controller but not

 

 

 

water heater.

 

 

 

●In such case it is impossible to get priority.

 

 

 

 

 

 

 

 

●Temperature setting range of water heater is 35-70 . When temperature is within 35-48 ,tap the temperature setting button to increase or decrease temperature, it actually switches by 1 /tap. Right after the completion of temperature setting, temperature icon flashes for 3 sec and then stays still. If temperature is within 50-70 , tap the temperature setting button to increase or decrease the temperature by 5 /tap. And when temperature setting completes, temperature icon flashes for 10 sec and then stays still.

8

●We suggest that user shall turn the water flow modulation knob to lower extent in winter and to higher extent in summer, so as to keep the water temperature in moderate range for your comfortable use.

●If temperature setting cannot be reached because it is beyond range of gas modulation, such case

(is common in winter) shall not be regarded as quality defect. Turn down the water flow to achieve the set temperature.

4.3Bathtub water fill-in(only for control panel and wireless remote controller)

4.3.1Pre-operation preparations

●Close the drainage port in the bathtub.

●Please cover the bathtub lid if mounted. (Open the lid up to let water in)

4.3.2 Please follow the below filling steps if control panel is used.

A. Press the power supply button on the control panel. Then panel flashes to show water fill-in at 42

Water fill-in temperature (e.g. 42 )

Priority indication on

B. Adjust water fill-in temperature with setting buttons.

Temperature up

Changed water fill-in temperature (e.g. 45 )

Priority indication on

Temperature down

C. Adjust water volume with setting buttons.

●Tap the water volume setting button. LCD flashes to display water volume setting. Change water flow volume setting with volume button.

●The water volume range is within 0-990L (unit:10L) according to desire.

●After water fill-in volume be set, LCD flashes to show current setting and fill-in temperature for 8 seconds.

Flash to show

 

water fill-in

 

volume

volume up

(e.g. 100L)

 

Priority indication on

volume down

D. Open the water-out valve

If the mixing valve is used, please turn to hot-water position.

E. Please close the water-out valve when the beeper starts to buzz, the buzz indicates completion

of set volume. By then LCD flashes to show current volume setting for 8 seconds. Please stop filling.

Special note:

The water heater is provided without auto reach-and-stop function.

Default volume setting is 100L.

V.Operation attentions

A.Keep room ventilated

Open the window to ventilate the room during application of water heater.

B.Do not touch the fume exhaust pipe and/or surrounding parts to prevent scald from hot water when water heater is on or after work.

C.No outdoor use. This water heater is a product designed for indoor only. Don’t make it work outside because rainwater may penetrate the housing of the water heater and cause damage to it.

9

10

 

D. Countermeasures for abnormality

Please immediately close the gas valve and water-in valve if following abnormalities occurs during the water heater running. Find out the reason in accordance with statements in judgments and countermeasures of errors and abnormalities. If it’s unable to be solved, please contact our after-sale service center immediately.

a.Gas flavor

b.Abnormal burning sound

c.Water leakage

E. Away from flammable matters

Gasoline, benzene and other flammable stuffs are strictly forbidden to be put near water heater.

F. Do not dismantle the water heater willfully

There are 220V electrical components and high-precision electronic components in the water heater, people except for authorized serviceman is not allowed to dismantle the housing to avoid electric shock and/or other unexpected loss.

G. Please close the gas valve after water heater stops.

VI. Anti-freezing attentions

6.1 If water residue is frozen in the water heater and no water flows out even if water-out valve is openning, please wait for natural defreezing.

Carefully check leakage of water-in and water-out pipes till water flows out from the valve. Then use the water heater as per correct operation procedure if no leakage is confirmed. To use water heater with frozen water residue can cause damage.

Damage from freezing is excluded from our warranty scope.

If water heater is to be idle for long term, please drain off residual water in pipes.

6.2 Indoor anti-freezing water heater is equipped with automatic heating unit to effectively avoid freezing. But please pay attention:

●Keep water heater energized. Anti-freezing function is not available without power supply.

●In extremely clod area , anti-freezing function is not available because electrical heating unit is not powerful enough.

●Anti-freezing function is only effective to water heater but not to water-in and water-out pipes.

6.3 Drain out water residue

1.Turn off the gas knob

 

2.Turn off the water supply konb

 

3.Turn on all hot-water faucets

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.Remove anti-freezing drainage plug and

 

5.Disconnect the power supply(turn off the

filter assembly

 

electric supply)

 

 

 

 

 

 

 

 

 

 

 

 

VII. Installation

7.1 Pre-unpacking check

Check out the attached fittings according to the below attachment list before installation.

Name and shape of attachment

Quantity

Name and shape of attachment

Quantity

 

2

 

2

Φ8 nylon expansion pipe

 

Φ4x50 wood screw

 

 

1

 

 

Operational instruction

 

 

 

11

12

7.2 Dimension

7.3 Installation attentions

●Check if gas supply is the same as specified gas on the label before installation, and check the voltage. Any inconformity is forbidden to the water heater.

 

 

 

Gas

 

 

 

 

 

Gas

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Manufactured gas

 

 

 

 

 

Natural gas

 

 

 

 

Liquefied petroleum gas

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated voltage 220V

 

 

 

 

 

Rated voltage 220V

Rated voltage 220V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated frequency 50HZ

 

 

 

 

Rated frequency 50HZ

 

 

 

 

 

Rated frequency 50HZ

 

Electricity

 

 

Electricity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

source

 

 

 

 

source

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

●Only authorized servicemen and qualified personnels are allowed for installation to ensure safety, reliability and correct use.

●Installation must comply with regulations and rules by local gas governing authority.

●If water heater is installed and used with inconformed gas, fire accident and blast combustion may occur or incomplete combustion can produce CO that leads to poisoning.

7.4 Installation site

●Install the water heater at well-ventilated site. The flue must be fitted with fume exhaust pipe whose outlet is located outside. It is necessary to open the window or door for smooth ventilation especially when range hood is working at the same time.

13

●Make sure the water heater installation is definitely away from cabinet, closet, chest, cupboard, curtain or other flammable materials.

●Installation over cooktop or other source of heat is forbidden.

●It’s forbidden to install water heater near electrical appliances or flammable materials (as gasoline, organic solvent) & corrosive

chemicals (as alcohol and muriatic acid), for prevention of fire accident and corrosion to the machine.

●Please keep a distance of at least 20cm away from both sides of water heater to ensure normal working and easy maintenance.

7.5 Flue gas exhaust

●Optimum performance of fume exhaust is guaranteed with our exhaust pipe, which is special designed for gas water heater. Do not change the structure or shape of the exhaust pipe.

●The distance between installation site and terminal of exhaust pipe must be within confined range. ●Fore-end of exhaust outlet (terminal) must be exposed. in the open air.

●Front end of exhaust pipe must be mounted with 1/50 inclination downward. ●Please install the extending pipe with 1/50 inclination down the horizon. ●Do not place any hazardous materials near terminal of exhaust pipe.

7.6 Positioning of exhaust outlet

Side view

Elevation

14

7.7 Water heater installation

1.Drill the wall and insert 2xΦ8 expansion pipes as per the sketch map and the drawn pitch for suspending installation holes.

2.Fix the hanger support with 2xΦ4x50 wood screw to the wall.

3.Suspend the water heater on the hanger support.

Wood screw Expansion pipe

Position to fixup the screw

Attention

The supporting wall bears a 16kg weight of the water heater, please take reinforcement actions in case of strength deficiency.

7.8 Fume exhaust pipe installation

7.8.1 Installation attentions

●The water heater must be mounted with fume exhaust pipe with ID Φ60mm/Φ100mm, please do not use fume exhaust pipe of other diameter.

●Fume exhaust pipe is allowed to have extension of 2m/1bent at most.

7.8.2 Typical installation case

●In order to settle the problem that fume exhaust hose is short in water heater installation, our company particularly offers two options for extension pipe, 500mm and 1000mm. If extension is required, please purchase it from local subsidiary or franchisor.

. Judgment and countermeasures for errors and abnormalities

8.1 Non-error cases

 

Phenomenon

Cause and countermeasure

 

Auto flameout after 45min continuous

Overtime safety protection. Close the hot-water faucet for

 

use

several seconds and re-open.

 

White flame from exhaust outlet

Exhausted fume contains much water steam, it turns white

 

when contacts cold air outside.

 

 

 

No hot water flows out immediately after

There is certain distance from the water heater to hot-water

 

hot-water faucet is turned on

faucet, what comes out first is the water residue, so you

 

 

need to wait a short while till it’s all drained.

 

Difficult ignition for initial use

Because there is air in the gas pipe, please turn the faucet

 

on and off times over, then you’ll make it.

 

 

 

Forced fan still rotates in the short term

Forced fan is designed with stop lag function in order to

 

after hot-water faucet is turned off

exhaust all flue gas in the combustion chamber.

 

Cold water flow out when the hot-water

Hot-water faucet is turned too small (less than startup flux)

 

so that automatic flameout and the water turns cold.

 

faucet is openned/turned small

 

It’s inappropriate to turn the faucet too small during use.

 

 

 

 

 

 

 

Water flows out from the safety valve

To relieve excessive pressure in order to avoid too much

 

pressure in the heat exchanger

 

 

 

 

 

 

 

Occassional sharp sound during use

Gas is empty or too low pressure for reducing valve

 

 

 

 

8.2 When flame symbol on the control panel disappears

●During use if the flame symbol on the control panel disappeared, it means safety protection be activated. Display flashes to show the error code from E1 to E8. Then user can know the cause for error and/or abnormality according to the indicated code.

Error code

Cause

Confirmation and countermeasures

E1

Ignition failure

Is gas knob turned on? Is there no gas in

the gas tank? Stop the water supply and

 

 

restart.

 

Accidental flameout or flue

Is there no gas in the gas tank? Is water

E2

pressure too low? Is gas supply smooth?

blockage

 

Stop the water supply and restart.

 

 

E3

Excess hot water or dry

Stop the water supply and restart

heating

 

 

E4

Failure of temperature sensor

Stop the water supply and restart.

 

 

 