Smart-UPS® XL

Uninterruptible Power Supply

Rack-Mount 3U

SUA2200/3000 VA 120/230 Vac

SUA3000 VA 100/200 Vac

English

990-2404B

11/2008

Introduction

Introduction

About this UPS

The APC Uninterruptible Power Supply (UPS) provides protection for electronic equipment from utility power blackouts, brownouts, sags and surges. The UPS filters small utility line fluctuations and isolates electronic equipment from large disturbances by internally disconnecting from utility line power. The UPS provides continuous power from the batteries until utility power returns to safe levels or the batteries are fully discharged.

Accessories

This UPS is equipped with an accessory SmartSlot. Refer to the APC Web site, www.apc.com for available accessories.

If a standard accessory, such as a Network Management Card is installed on this UPS, refer to the accessory user manual or CD for installation and operation instructions.

Install accessories prior to connecting power to the UPS.

Unpack

Read the Safety Guide before installing the UPS.

Inspect the UPS upon receipt. Notify the carrier and dealer if there is damage. The packaging is recyclable; save it for reuse or dispose of it properly. Check the package contents:

• UPS

• Rail kit

 

 

• Front bezel

• EPO connectors

 

 

 

 

 

 

120 V Models Only:

 

100/200 V Models Only:

230 V Models Only:

UPS literature kit contents:

UPS literature kit contents:

UPS literature kit contents:

• Two rack-mount brackets

• Two rack-mount brackets

• Two rack-mount brackets

• Four cage nuts

 

• Four cage nuts

• Four cage nuts

• Eight flathead screws

 

• Eight flathead screws

• Eight flathead screws

• Product documentation

• Product documentation

• Product documentation

• Smart-UPS® User Manuals CD

• Serial communication cable

• Smart-UPS® User Manuals CD

• PowerChute® Business Edition CD

• Safety information

• PowerChute® Business Edition CD

• Serial and USB communication cable

• Warranty information

• Serial and USB communication cable

• Safety information

 

 

• Safety information

• Warranty information

 

 

• Warranty information

 

 

 

• Input power cord

 

 

 

• Alternate input power cord

 

 

 

(UK customers)

 

 

 

• Utility connector plug

 

 

 

• IEC jumper cables

 

 

 

 

NOTE: The model and serial numbers are located on a small, rear panel label. For some models, an additional label is located on the chassis under the front bezel.

Smart-UPS XL 3U Rack Mount 2200/3000 VA 120/230 Vac; 3000 VA 100/200 Vac User Manual

3

Specifications

Specifications

Environmental

Temperature

 

 

 

 

 

 

This unit is intended for indoor

Operating

0° to 40°C (32° to 104°F)

 

 

 

 

use only. Select a location sturdy

Storage

-15° to 30°C (5° to 86°F) charge the UPS battery every six

 

 

enough to handle the weight.

 

months

 

 

 

 

 

Do not operate the UPS where

 

30° to 45°C (86° to 113°F) charge the UPS battery every three

 

there is excessive dust or the

 

months

 

 

 

 

 

temperature or humidity are

 

 

 

 

 

 

 

outside the specified limits.

Maximum

 

 

 

 

 

 

 

 

 

 

 

 

Be sure the air vents on the

Elevation

 

 

 

 

 

 

 

 

 

 

 

 

UPS are not blocked.

Operating

3,000 m (10,000 ft)

 

 

 

 

 

 

 

 

Environmental factors impact

Storage

15,240 m (50,000 ft)

 

 

 

 

 

 

 

 

battery life. High temperatures,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

poor utility power, and frequent,

Humidity

0 to 95% relative humidity, non-condensing

 

 

 

 

short duration discharges will

 

 

 

 

 

 

 

shorten battery life.

 

 

 

 

 

 

 

 

 

 

 

 

 

Physical

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions

133 mm x 483 mm x 673 mm

 

 

 

 

 

 

 

H/W/D

5.2 in x 19 in x 27 in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Weight

73 kg (161 lbs) shipping weight

 

 

 

 

 

63 kg (139 lbs)

 

63 kg (139 lbs) with battery module

 

 

 

 

 

 

37 kg (82 lbs) without battery module

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum Number of External Battery Packs Supported by the

 

 

10

 

 

Smart-UPS XL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100 V models

120 V models

 

200 V models

 

230 V models

 

 

 

 

 

 

 

 

 

 

Output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output Frequency

 

50/60 Hz +/– 3 Hz

 

 

 

 

 

 

 

 

 

 

Nominal Output Voltage

100 V

120 V

 

 

200 V

 

230 V

 

 

 

 

 

 

 

 

 

 

Input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input Frequency

 

 

50/60 Hz +/– 3 Hz

 

 

 

 

 

 

 

 

 

 

Nominal Input Voltage

100 V

120 V

 

 

200 V

 

230 V

 

 

 

 

 

 

 

 

 

 

4

Smart-UPS XL 3U Rack Mount 2200/3000 VA 120/230 Vac; 3000 VA 100/200 Vac User Manual

APC SUA2200 User Manual

Installation

Installation

Your UPS model may vary in appearance from the examples depicted in this manual.

The UPS and the battery modules are heavy. Remove the battery modules to lighten the UPS during installation.

Install the Rails in the Rack

This UPS is intended for installation in a 19” rack.

For details on rail installation refer to the instructions in the rail kit.

Install the UPS in the Rack and Connect the Battery Module

Install the UPS at or near the bottom of the rack.

%

4x

4x

!

"

$

&

#

Smart-UPS XL 3U Rack Mount 2200/3000 VA 120/230 Vac; 3000 VA 100/200 Vac User Manual

5

Installation

Rear Panels

2200/3000 VA 120 Vac

3000 VA 100 Vac

3000 VA 200 Vac

2200/3000 VA 230 Vac

TVSS

G ND

Rear Panel Features

 

 

The UPS features a TVSS screw located on the rear panel for connecting the ground leads on

 

 

transient voltage devices.

 

 

The UPS is equipped with an external battery connector located on the rear panel of the unit.

 

 

Where appropriate use an APC extension battery cable. For ordering details contact your dealer or

 

 

APC through the Web site www.apc.com.

 

 

120 V models only: The UPS is equipped with a Site Wiring Fault LED located on the rear panel of

 

 

the unit. The LED will be illuminated if the UPS is plugged into an improperly wired utility power

 

 

outlet, (see Troubleshooting in this manual).

 

 

USB and Serial connectors are communication ports.

 

 

Use only an APC approved cable to connect to the serial port. A standard serial interface cable

USB

Serial

is incompatible with the UPS.

Serial and USB ports cannot be used simultaneously. USB has priority over Serial.

The UPS has a SmartSlot located on the rear panel for adding optional accessories to the unit.

100/120/200 V model circuit breaker and line cord connection.

230 V model circuit breaker and line cord connection.

The UPS is equipped with an emergency power off feature located on the rear panel of the unit.

6

Smart-UPS XL 3U Rack Mount 2200/3000 VA 120/230 Vac; 3000 VA 100/200 Vac User Manual

Start-up and Operation

Connect equipment, external battery pack(s), and power to the UPS

Prior to connecting the grounding cable, ensure that the UPS is NOT connected to utility or battery power.

1.Connect equipment to the UPS.

2.Optional external battery packs provide extended runtime during power outages. This unit supports up to ten external battery packs. Refer to the APC Web site, www.apc.com for information. Refer to the user manual for the external battery pack for installation instructions.

3.Add optional accessories to the SmartSlot located on the rear panel.

4.Plug the UPS into a two-pole, three-wire, grounded receptacle only. Avoid using extension cords.

230 V models: The utility power cord is supplied in the UPS literature kit. Prior to connecting the utility power, connect the ground lead (optional) to the chassis ground connection screw.

5.To use the UPS as a master on/off switch be sure all connected equipment is switched on.

Start-up and Operation

Start the UPS

1.Press the button on the front panel to start the UPS.

When the UPS utilizes only an internal battery, the internal battery charges to 90% capacity during the first four hours of normal operation.

Do not expect full battery run capability during this initial charge period.

The charge time for internal and external batteries will vary depending on the number of batteries connected to the UPS.

Refer to the APC Web site, www.apc.com for battery runtimes.

2.For optimal computer system security, install PowerChute Smart-UPS monitoring software.

Smart-UPS XL 3U Rack Mount 2200/3000 VA 120/230 Vac; 3000 VA 100/200 Vac User Manual

7

Loading...