APC ACRP500, ACRP100, ACRP501, ACRP102, ACRP101 User Manual

...
4.3 (3)

InRow® RP

Chilled Water/Direct Expansion — 50/60 Hz

AIR-COOLED

ACRP100

ACRP101

ACRP102

CHILLED WATER

ACRP500

ACRP501

ACRP502

Technical Data

American Power Conversion Legal Disclaimer

The information presented in this manual is not warranted by the American Power Conversion Corporation to be authoritative, error free, or complete. This publication is not meant to be a substitute for a detailed operational and site specific development plan. Therefore, American Power Conversion Corporation assumes no liability for damages, violations of codes, improper installation, system failures, or any other problems that could arise based on the use of this Publication.

The information contained in this Publication is provided as is and has been prepared solely for the purpose of evaluating data center design and construction. This Publication has been compiled in good faith by American Power Conversion Corporation. However, no representation is made or warranty given, either express or implied, as to the completeness or accuracy of the information this Publication contains.

IN NO EVENT SHALL AMERICAN POWER CONVERSION CORPORATION, OR ANY PARENT, AFFILIATE OR SUBSIDIARY COMPANY OF AMERICAN POWER CONVERSION CORPORATION OR THEIR RESPECTIVE OFFICERS, DIRECTORS, OR EMPLOYEES BE LIABLE FOR ANY DIRECT, INDIRECT, CONSEQUENTIAL, PUNITIVE, SPECIAL, OR INCIDENTAL DAMAGES (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS, CONTRACT, REVENUE, DATA, INFORMATION, OR BUSINESS INTERRUPTION) RESULTING FROM, ARISING OUT, OR IN CONNECTION WITH THE USE OF, OR INABILITY TO USE THIS PUBLICATION OR THE CONTENT, EVEN IF AMERICAN POWER CONVERSION CORPORATION HAS BEEN EXPRESSLY ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. AMERICAN POWER CONVERSION CORPORATION RESERVES THE RIGHT TO MAKE CHANGES OR UPDATES WITH RESPECT TO OR IN THE CONTENT OF THE PUBLICATION OR THE FORMAT THEREOF AT ANY TIME WITHOUT NOTICE.

Copyright, intellectual, and all other proprietary rights in the content (including but not limited to software, audio, video, text, and photographs) rests with American Power Conversion Corporation or its licensors. All rights in the content not expressly granted herein are reserved. No rights of any kind are licensed or assigned or shall otherwise pass to persons accessing this information.

This Publication shall not be for resale in whole or in part.

Contents

Overview ..........................................................................

1

Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Room Air Distribution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Compliance Approval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Chilled Water Standard Features . . . . . . . . . . . . . . . . . . . . . . . . . 1

Air-cooled Standard Features . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Scalable Solution for Critical Environments ................

2

InRow Advantages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

 

Scalable for High Density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

 

Hot Aisle Containment System . . . . . . . . . . . . . . . . . . . . . . . . . . .

3

 

Standard Features...........................................................

4

Insulated Cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

Variable Speed Fans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

Shutdown Input/Alarm Output . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

Chilled Water Flow Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

2-way/3-way Floating Point Valve (CW Only) . . . . . . . . . . . . . . . . .

4

Counterflow Cooling Coil/Condensate Pan . . . . . . . . . . . . . . . . . .

4

Electric Reheat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

30% ASHRAE 52.1 Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

Pipe Adapters (CW only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

Pipe Adapters (Air-Cooled only) . . . . . . . . . . . . . . . . . . . . . . . . . .

4

Selectable Top or Bottom Piping Connections . . . . . . . . . . . . . . .

4

Dual Position Float Condensate Management . . . . . . . . . . . . . . .

5

Network Management Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

Bay Kit InRow RP/NetShelter SX . . . . . . . . . . . . . . . . . . . . . . . . .

5

Remote Temperature Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

Humidifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

Optional Features............................................................

6

Cable Water Detector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6

Network Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6

85% ASHRAE 52.1 Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6

Power Trough . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6

Data Partition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6

Height Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6

Flex Hose Piping Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6

Microprocessor Controller

............................................. 7

Microprocessor Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

Open Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

Control Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

Logging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

Chilled Water Only Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

Air-cooled Only Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

InRow RP Technical Data Manual

i

InRow RP Models ............................................................

9

Chilled Water Interior Components (front of unit) . . . . . . . . . . . .10

Air-cooled Interior Components (front of unit) . . . . . . . . . . . . . .12

Air-cooled Interior Components (back of unit) . . . . . . . . . . . . . .13

Chilled Water and Air-cooled User Interface Connections . . . . . .14

Chilled Water Electrical Panel . . . . . . . . . . . . . . . . . . . . . . . . . . .15

Air-cooled Electrical Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

Performance Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Chilled Water Performance Specifications 5.5°C (42°F) EWT . . . .17

Chilled Water Performance Specifications 7.2°C (45°F) EWT . . . .18

Chilled Water Performance Specifications 8.9°C (48°F) EWT . . . .19

Chilled Water Performance Specifications 10°C (50°F) EWT . . . .20

Chilled Water Performance Specifications 12.8°C (55°F) EWT . . .21

Chilled Water Performance Specifications 15.5°C (60°F) EWT . . .22

Chilled Water Data - General . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 Glycol Correction Factors . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24

Altitude Correction Factors for InRow Products . . . . . . . . . . . . .24 Air-cooled Performance Specifications . . . . . . . . . . . . . . . . . . . .24

Air-cooled Data - General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 Sound Performance Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26

Dimensional Data ..........................................................

27

InRow RP Assembled Module . . . . . . . . . . . . . . . . . . . . . . . . . . .

27

SX to VX Height Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

28

SX to 48U SX Height Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . .

28

Piping and Mechanical Connections...........................

29

Chilled Water Piping Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . .

29

Top Chilled WaterPiping Access (top view) . . . . . . . . . . . . . . . .

30

Air-cooled Piping Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

32

Air-cooled Piping Access (top) . . . . . . . . . . . . . . . . . . . . . . . . . .

33

Air-Cooled Condensers ................................................

35

Mechanical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

35

Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

35

ACCD75201 and ACCD75204 . . . . . . . . . . . . . . . . . . . . . . . . . . .

36

ACCD75202 and ACCD75205 . . . . . . . . . . . . . . . . . . . . . . . . . . .

36

ACCD75203 and ACCD75206 . . . . . . . . . . . . . . . . . . . . . . . . . . .

36

ACCD75207 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

37

ACCD75208 and ACCD75209 . . . . . . . . . . . . . . . . . . . . . . . . . . .

37

Air-cooled Condenser Features . . . . . . . . . . . . . . . . . . . . . . . . .

37

Guide Specifications.....................................................

38

Guidelines for Installation ............................................

44

Room preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44

Service access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44

Receiving the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44

Rigging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44

Condensate Drain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44

ii

InRow RP Technical Data Manual

Overview

The modular, row-based computer room cooling system offers efficient, predictable, and economical cooling for a variety of spaces.

Critical environmental requirements now reach far beyond the confines of the traditional data center or computer room to encompass a larger suite of applications, referred to as technology rooms. Critical environment applications include:

Computer rooms

Telecommunication facilities

Clean rooms

Power equipment

Medical equipment rooms

LAN/WAN environments

A worldwide network of APC representatives is fully qualified to provide engineering, sales, installation, and service for our products.

APC warrants all parts for 18 months from shipment and 12 months from startup. Extended warranties are available.

Capacity

The InRow RP chilled water configuration is available in one size with a capacity that is up to 60 kW based on the particular application of the unit. The InRow RP air-cooled configuration is available in one size with a capacity that is up to 37 kW.

Room Air Distribution

Row-based systems are placed in line with rack enclosures. At least one system is used per hot aisle. Air is drawn in through the rear of the system, cooled, and discharged into the cold aisle, thereby neutralizing the sensible heating effects of the data processing equipment.The InRow RP delivers high volumes of airflow to eliminate hot spots in densely populated environments.

Configuration

Chilled Water

Air-cooled

Compliance Approval

UL Listed

VDE

CE

C-tick

C-UL Listed

Chilled Water Standard

Features

Insulated cabinet

Backward inclined impeller

Variable speed fans (3)

Shutdown input/alarm output

Chilled water flow meter

2-way/3-way floating point valve

Humidifier

Counter flow cooling coil

Electric reheat

Pleated 100 mm (4 in) filter

NPT to BSPT pipe adapters

Top or bottom piping

Condensate management with dual position float

Network management card

Baying Kit InRow RP to NetShelter® SX rack

Remote temperature sensor (3)

Microprocessor controller

Automatic transfer switch

Air-cooled Standard

Features

Insulated cabinet

Backward inclined impeller

Variable speed fans (2)

Shutdown input/alarm output

Humidifier

Cross circuited cooling coil

Electric reheat

Pleated 100 mm (4 in) filter

Pipe adapters

Top or bottom piping

Condensate management with dual position float

Network management card

Baying kit InRow RP to NetShelter® SX rack

Remote temperature sensor (3)

Microprocessor controller

Variable speed reciprocating compressor using VFD control

Liquid line solenoid valve

Pressure equalization solenoid

Accessories

Cable leak detector

Baying kit InRow RP to NetShelter VX rack

NetShelter SX 42U to 48U height adapters

NetShelter VX 42U height adapters

Bridge trough power cable shield

Data cable bridge partition

Flex hose piping kits

InRow RP Technical Data Manual

1

Scalable Solution for Critical

Environments

InRow Advantages

The row-based solution improves energy efficiency and cooling ability in a number of ways. First, the InRow RP draws air directly from the hot aisle, allowing the InRow RP to take advantage of higher heat transfer efficiency due to higher temperature differences. It can then discharge room temperature air directly in front of the servers it is cooling. This increases energy efficiency by allowing the chiller to operate at higher leaving water temperatures. Placing the cooling unit in the row enables the unit to operate at higher return and supply air temperatures, yielding 100% sensible capacity. This significantly reduces the need for humidification.

Scalable for High Density

The predictable performance of the row-based architecture makes it well suited for high density applications. The focus on heat removal instead of cold air delivery is the key to making this approach scalable. The modular design of the InRow RP allows it to be easily added in the row as the demand for cooling increases.

The additional benefit of the row-based architecture is the ability to add hot aisle containment. Containing the hot aisle further reduces any chance of hot and cold air streams mixing. This provides ultimate predictability and allows the cooling capacity to be matched to the IT heat load.

2

InRow RP Technical Data Manual

Hot Aisle Containment System

Modular ceiling tiles and doors can be used to enclose the hot aisle. This increases the densities that can be handled in a single rack enclosure by eliminating mixing of hot and cold air streams. This method, called load neutralization, removes the heat from the hot aisle, cools it, and then returns it to the surrounding room area at or slightly below room temperature. The warmer return air temperatures that are achieved in this application increase the capacity of the air conditioner.

Use of modular ceiling tiles across a 914.4 mm (3 ft) hot aisle that connects two opposite rack enclosures makes expansion quick and simple. Expansion kits, with necessary ceiling tile and all baying hardware, can be ordered to increase the size of the hot aisle by one rack on each side. The end doors can be easily removed and re-attached for expansion.

The enclosed hot aisle prevents any warm return air from mixing with cold supply air. In effect, all surrounding room air can act as supply air to the system. The hot aisle containment system is beneficial in any environment. It can be deployed quickly in any controlled space without expensive additions to the infrastructure, such as raised floor or ductwork.

na2763b

NetShelter NetShelter

InRow

UPS

PDU

PDU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

990.60

 

 

 

 

 

1155.70

1325.88

(39.00)

 

 

 

 

 

(45.50)

( 52.20)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NetShelter NetShelter

InRow

NetShelter NetShelter

PDU

1798.58 (70.81)

874.523037.80

(34.43) (119.60)

1331.72

(52.43)

na2762d

600

600

600

600

600

600

(23.62)

(23.62)

(23.62)

(23.62)

(23.62)

(23.62)

Dimensions are shown in mm (in).

InRow RP Technical Data Manual

3

Standard Features

Insulated Cabinet

The frame is constructed of 1.5 mm (16 gauge) formed steel for maximum strength. Cabinet is serviceable from the front and rear. All exterior panels and corner posts on the frame are powder coated for durability and an attractive finish. Front and rear exterior panel are constructed of 1.2 mm (18 gauge) perforated steel with 69.5% open free area. Insulation is 80.1 kg/m3

(5 lb/ft3) density and complies with ASTM E84 rating of 25/50. All panels include a key latch for safety and security for easy access and removal.

Variable Speed Fans

The InRow RP unit is equipped with variable speed, electrically commutated, 400 mm (15.8-in) backward incline, direct drive fans. The chilled water unit is equipped with three fans while the air-cooled unit has two. In order to provide uniform airflow over the cooling coil, the fans provide a draw-through air pattern. Fans are easily serviced in the field.

Shutdown Input/Alarm Output

The unit provides one field connection input for remote shutdown and one field connection alarm output.

Chilled Water Flow Meter

Internal piping of the unit includes a flow meter wired into the microprocessor controller to display chilled water flow and determine operating performance.

2-way/3-way Floating Point Valve (CW Only)

A floating point valve is microprocessor controlled to regulate the amount of chilled water into the cooling coil to maintain desired conditions. The standard valve pressure rating is 4136.8 kPa

(600 psig). The maximum operation pressure of the unit is 2068.4 kPa (300 psig). The valve is user configurable to be two-way or threeway.

Counterflow Cooling Coil/ Condensate Pan

Designed for high sensible heat ratios, the coil is constructed with copper tubes, raised lance type aluminum fins, and 1.2 mm (18 gauge) galvanized steel end plates. Coil headers are equipped with anti drip shields in case of condensation. Condensate pan is UL94 V-0 thermal formed non-ferrous material sloped for positive drainage for higher indoor air quality.

Electric Reheat

Electric reheat elements are low watt density, wired for three-phase and loaded equally on all three phases, and electrically and thermally protected by both automatic and manual reset thermal cut outs. Reheat elements are stainless steel, fin tubular construction.

30% ASHRAE 52.1 Filter

The filtration of conditioned air is extremely vital to maintaining the clean, particle-free environment required by electrical equipment. The system uses a 30% efficient, 100 mm (4 in), deep loading, pleated filter. Deeper filters produce a lower pressure drop, requiring less energy during normal operation. The filter is moisture resistant up to a 100% relative humidity. Filters are easily replaceable from the rear of the unit. (MERV 8 per ASHRAE 52.2, EN779 G4)

Pipe Adapters (CW only)

Standard pipe connections are 38.1 mm (1 1/2 in) NPSM (manufactured in accordance with ANSI B.1.20.1).

Pipe Adapters (Air-Cooled only)

Standard pipe connections are 31.75 mm (1 1/4 in) 12 UNF female Rotolock (manufactured in accordance with ANSI B1.1). The adapter converts the rotolock to a sweat adapter.

Selectable Top or Bottom Piping Connections

Unit includes both top and bottom piping connections. Top piping connects to internal stubs and routes piping upward out of the unit. Bottom piping connects to internal stubs and routes piping downward out of the unit. All connections utilize unions or rotolok fittings for ease of installation and service

4

InRow RP Technical Data Manual

Dual Position Float Condensate Management

The pump is factory wired and piped internally to the condensate drain pan and humidifier outlet. The pump is capable of pumping a maximum of 18 m (60 ft) at 0.009 l/s (8.45 GPH), which may include a maximum lift of 3.5 m (11.5 ft) of head. A dual position float is included with the unit. One position is used for condensate pump control, the other to alarm condensate pump failure which shuts down the RP to prevent condensate pump overflow.

Network Management Card

Permits multi-level access to monitoring, control, and event notification features over the user’s network.

Bay Kit InRow RP/ NetShelter SX

Baying kits made of 1.5 mm

(16 gauge) steel enable baying of the cooling system to APC NetShelter SX enclosures.

Remote Temperature Sensors

To control the unit based on rack inlet temperature, three remote sensors are provided. These sensors measure at 4 m (13 ft) from the connection point inside the RP. The sensors are used for remote placement in the field on adjacent IT racks.

Humidifier

The humidifier is a self-contained, steam-generating type, factory piped and wired, with a disposable cylinder and an automatic solid state control circuit. Humidifier canisters are replaceable. The humidifier controller communicates directly to the microprocessor controller and provides complete status and control at the operator interface.

InRow RP Technical Data Manual

5

Optional Features

Cable Water Detector

A leak detection cable is placed on the floor or subfloor around all possible leak sources. If water or other conductive liquids contact the cable anywhere along its length, the microprocessor controller announces the leak visually, audibly, and across the network. The 6.1 m (20 ft) cable may be cascaded to make custom lengths up to 24.4 m (80 ft).

Network Cable

Various lengths of network cable are available to ship with your cooling system. The network cable is used to interconnect multiple cooling units in a redundant group, as well as to connect the network management card to your LAN.

85% ASHRAE 52.1 Filter

Electrical equipment requires clean, particle free air, thus making the filtration of the air extremely important. Optionally, the system uses a 85% efficient, 100 mm (4 in), deep loading, pleated filter. Deeper filters produce a lower pressure drop, requiring less energy during normal operation. The 100% synthetic media will not absorb moisture and is resistant to most common chemicals. The filter is moisture resistant up to a 100% relative humidity. Filters are easily replaceable from the rear of the unit. (MERV 13 per ASHRAE 52.2, EN779 F7)

Power Trough

Overhead power distribution between adjacent NetShelter racks allows for removal of the InRow RP without disrupting overhead power cabling.

Data Partition

Overhead cable distribution between adjacent NetShelter racks allows for removal of the InRow RP without disrupting overhead cabling.

Height Adapters

To match height of the InRow RP to various rack heights, height adapters are available for NetShelter 42U VX and 48U SX racks.

Flex Hose Piping Kits

For hard piping to the chilled water InRow RP, stainless steel flex piping kits are available. The kits ship with two 0.914 m (3 ft) or 1.828 m (6 ft) pipes, depending on selection.

Connections are 1.25 in NPT to 1.5 in NPSM, OFS female.

6

InRow RP Technical Data Manual

Microprocessor Controller

Microprocessor Controller

The microprocessor controller is standard on each system. The controller provides precision control for the demanding requirements of:

Computer rooms

Telecommunication facilities

Clean rooms

Power equipment

Medical equipment rooms

LAN/WAN environments

The easy-to-use display allows the operator to select options from the device’s menu-driven interface to control and monitor the connected air conditioning system.

Open Architecture

The InRow RP protocol is open for integration with all building management systems. Communication interface on the system can be MODBUS RS485 or Ethernet.

Control Type

Controller utilizes proportional/ integral/derivative (PID), a timeproven precision environmental control method. This allows for custom tuning of control variables to achieve desired system response.

Functions

Supply and Return Air Conditions

Operational Mode Control

Event Logging

Alarms

Redundant Group Control

Fan Speed Adjustment

Input/Output Module Programming

 

Critical Alarm LED

 

 

 

Warning Alarm LED

 

 

 

Check Log LED

 

 

 

Status LED

 

 

 

Liquid Crystal Display (LCD)

 

 

 

Menu Selection scroll keys

 

 

 

Escape key

 

 

 

Enter key

 

 

 

Help key

 

 

Logging

The event log keeps a record of all alarms and events. Each event log contains a time/date stamp as well as operating conditions at the time of occurrence. The controller also displays run time, in hours, for major components (air filters, fans, and condensate pump, as well as humidifier, heater, and compressor for the air-cooled unit).

Control

The backlit, four-line by twentycharacter display is password configurable.

InRow RP Technical Data Manual

7

Alarms

The microprocessor controller shall activate a visible and audible alarm in the following occurrences:

Cool Fail

Rack inlet temperature violation

Rack inlet temperature sensor fault

Air filter clogged

Air filter run hours exceeded

Filter DP sensor failure

Supply air sensor fault

Return air sensor fault

Supply air high temperature violation

Return air high temperature violation

Fan fault

Fan run hours exceeded

Water detection fault

Condensate pump fault

Condensate run hours exceeded

Humidifier water conductivity high violation

Humidifier fault tolerance exceeded

Humidifier low water

Humidifier excessive output reduction

Humidifier drain fault

Humidifier cylinder full

Humidifier replace cylinder

Humidifier RS485 communication fault

Humidifier run hours violation

Humidity high/low violation

Supply humidity sensor fault

Return humidity sensor fault

Heater fault

Heater run hours exceeded

Heater interlock shutdown

Group communication fault

Internal communication fault

A-link isolation relay fault

External communication fault

Input contact fault

Invalid supply setpoint

Idle mode active

Chilled Water Only Alarms

Coil fluid valve actuator fault

Fluid flow fault

Entering fluid temperature high violation

Entering fluid temperature sensor fault

Leaving fluid temperature sensor fault

Power source failure

Fluid calibration

Air-cooled Only Alarms

High discharge pressure

Low suction pressure

High suction pressure

Compressor drive failure

Compressor drive warning

Compressor run hours violation

Compressor drive RS485 communication fault

Excessive compressor cycling

Air flow decreased while compressor off

Suction pressure sensor failure

Discharge pressure sensor failure

High pressure switch active

Fan speed decreased to avoid high pressure (event only)

Compressor speed decreased to avoid high pressure (event only)

Compressor high pressure

Oil return pump active

8

InRow RP Technical Data Manual

InRow RP Models

na1824a

 

Hinged rear doors

 

Casters (all swiveling)

 

Side panel lock

 

Door handle and lock

 

Removable side panel

 

Display interface

 

Adjustable leveling foot

 

Hinged front door

InRow RP Technical Data Manual

9

APC ACRP500, ACRP100, ACRP501, ACRP102, ACRP101 User Manual

Chilled Water Interior Components (front of unit)

na2090a

Electric heater (for reheat)

Electrical panel

Fan

Supply temperature sensors

Fan guard

Main feed breakers

Humidifier

Ladder diagrams

Condensate drain pan

User interface connectors

Condensate pump

Supply humidity sensor

10

InRow RP Technical Data Manual

Chilled Water Interior Components (back of unit)

na2105a

Chilled water coil

Chilled water control actuator

Chilled water three-way valve body

Flow meter

Pipe chase

Rear doors

Air filters

Return humidity sensor

Return temperature sensor

InRow RP Technical Data Manual

11