A. O. Smith NW-150 User Manual

0 (0)
A. O. Smith NW-150 User Manual

Commercial Electric Hot Water Boilers

A. O. Smith’s Electric Boilers are designed for demanding hydronic and industrial heating needs. A wide variety of available electrical inputs and voltages allow the units to be perfectly matched to the heating requirements of the application and the available electrical services.

FEATURES

MODULATING STEP CONTROL - A solid state modulating step control modulates heat input to match load through progressive sequencing of steps. Standard on models with 90kW or above (optional below 90kW).

INCOLOY IMMERSION HEATERS - Heavy duty medium watt density elements (3 per immersion heater) have incoloy sheathing, provides excellent protection against oxidation and scaling. The input ranges from 45kW to 6,000kW (see accompanying chart).

OPTIONAL GOLDENROD® ELEMENTS - All NW models are available with the Goldenrod 24K gold plated element. Goldenrod Elements provide long-life and five times the scaling resistance of standard incoloy elements. Goldenrod Elements carry a three-year warranty against failure due to scale.

FUSING - Control and power circuit fusing to meet the National Electrical Code. 100,000 amp I.C. cartridge-type fuses protect all elements and contactors.

PILOT SWITCH AND LIGHT - Permits manual starting and stopping of heater by interrupting power to control circuit. Pilot light indicates when control circuit is energized.

MAGNETIC CONTACTORS - Heavy duty UL rated for 100,000 cycles.

LOW WATER CUTOFF - Probe type, electric low water cutoff prevent energizing of elements in the event of low water condition.

120 VOLT CONTROL CIRCUIT - Powered by fused transformer.

ASME CODE CONSTRUCTION - All vessels manufactured to applicable ASME Code. Vessels with maximum working pressure of 160 psi or less (standard design is for 125 psi) at 240°F maximum temperature bear the “H” symbol per Section IV of ASME Code. Vessels with greater

than 160 psi working pressure or higher than 240°F operating temperature will bear the “S” symbol per Section I of ASME Code.

UL LISTED - All boilers are UL listed per Underwriters’ Laboratories Standard No. 834.

ONE YEAR LIMITED WARRANTY

Θ For complete warranty information, consult written warranty.

OTHER STANDARD FEATURES

ΘTwo high temperature limit controls

ΘCabinet has a baked powder coat finish

ΘRectangular jacket made with 18 gauge (minimum) steel

Θ3” fiber glass insulation

ΘColor coded circuitry for easier servicing

ΘStandard voltages include 208, 240, 480 and 575 volt, single or three-phase

ΘFactory installed terminal block(s)

ΘCombination Temperature/Pressure Gauge

ΘBoiler drain valve

ΘCSA Certified and ASME Rated T&P Relief Valve

NW-37

through

NW-670

®

*Model shown with optional accessories

 

Page 1 of 4

May 2012R

AOSHE30000

Commercial Electric Hot Water Boilers

UL MINIMUM CLEARANCE REQUIRMENTS: 24” ALL SIDES, 12” TOP

NOTE: ALLOW 30” CLEARANCE FOR HINGED CONTROL

COMPARTMENT DOORS.

ELEMENTS CAN BE CHANGED WITH 24” CLEARANCE.

AN ADDITIONAL CONTROL PANEL IS REQUIRED ON

UNITS ABOVE 500kW RATED AT 208 OR 240 VOLTS.

MODELS: NW-37, NW-60, NW-96 AND NW-150

 

MODELS: NW-220, NW-334, NW-400, NW-500 AND NW-670

May 2012R

Page 2 of 4

www.hotwater.com

AOSHE30000