Commercial Storage Tanks
FACTORY JACKETED AND
INSULATED STORAGE TANKS
These A. O. Smith storage tanks are designed for storing potable water. Fitting locations are designed to meet the needs of normal installations plus those for the A. O. Smith Cer-Temp 80® piping methods.
FEATURES
A. O. Smith storage tanks are ideal for use with gas-fired copper heat exchanger equipment for storage of any potable water at temperatures up to 180°F.
GLASS LINED TANK - Alkaline borosilicate composition permanently fused to steel by firing at a temperature of 1600°F, providing years of corrosion protection and dependable use.
HEAVY GAUGE STEEL JACKET - With baked enamel finish.
THREADED OPENINGS - All tanks furnished with threaded openings for thermometer, relief valve, 2” recirculation lines, tankstat, and drain valve.
INSULATION - Storage Tanks meet or exceed R12.5 minimum thermal insulation requirements of the U. S. Department
of Energy and current edition of ASHRAE/IESNA 90.1
TJ-80S, TJ-80A, TJV-120M and TJV-120A
protection
TJ-80A
energy, helps reduce standby heat loss
TJV-120A
energy, helps reduce standby heat loss
TJ-80S
energy, helps reduce standby heat loss
TJV-120M
energy, helps reduce standby heat loss
TJV-200-M - 175 GALLONS
with 200 gallons of storage.
protection
5 YEAR WARRANTY
If the tank should leak any time during the first 5 years, under the terms of the warranty, A. O. Smith will repair or replace the tank. Installation, labor, handling
and local delivery are extra. For complete information, consult the written warranty.
MODELS
TJ-80S, TJ-80A
TJV-120A, TJV-120M
& TJV-200M
(FOR SELECT MODELS)
SUGGESTED SPECIFICATION
Storage tank shall be A. O. SMITH glasslined storage tank. Tank shall be ________ “ x ________ “ and have a nominal capacity of _________ gallons. Tank(s) shall have threaded openings as shown on drawings. Interior of tank(s) shall be glasslined with an alkaline borosilicate composition which has been fused to the steel by ring at a temperature of . lass coating shall be continuous over the entire inner surface of the tank. Outer acket shall have a baked enamel nish. Meets minimum thermal insulation reuirements of the .S. epartment of nergy and current edition of ASHAISA.. athodic protection shall be provided. Tank shall have a working pressure of _________ psi. Tank shall have a ve year limited warranty as outlined in the written warranty.
|
Page 1 of 2 |
April 2015R |
AOSTT35100 |