Air to water heatpump • Storage capacity 285 liter • Very high COP of 3,2 / 3,5 • Suitable for air temperatures between 0°C-35 °C (depending on the model) • Plug and play installation • Easy and user friendly control • Water temperature with the heat pump up to 55°C • Additional electric element of 1,5 kW standard • Water temperature with additional electric element up to 65 °C • Very silent operation • AH 290 basic version with air intake and air outlet indoors • AHD 290 with air intake and air outlet from outside the building and defrost function • AHDS 290 with additional integrated solar heat exchanger for thermal solar applications

Innovation has a name.

AH(D)(DS)

Technical specifications

 

 

AH 290

AHD 290

AHDS 290

Functioning parameters

 

 

 

 

Minimum air temperature

°C

8

0

-

Maximum air temperature

°C

35

35

-

Air flow per hour

m3

280

280

-

Max hot water temperature heatpump

°C

55

55

-

Max hot water temperature heatpump + electric element

°C

65

65

-

Electrical data

 

 

 

 

Main electric connection

 

 

230(-15%/+10%)/50(+/- 1Hz)

 

Motor

 

AC

AC

-

Power consumption

W

560

560

-

Electric connection

A

13

13

-

COP

-

3,2

3,5

-

Power consumption electric element

kW

1,5

1,5

-

Fan speed

r.p.m.

2500

2500

-

General/Cooling info

 

 

 

 

Heat capacity

kW

1,96

1,96

-

Refrigerant

 

R 134 a

R 134 a

-

Refrigerant filling

Kg

0,9

0,9

-

Maximum working pressure tank

bar

8

8

-

Sound level (1 meter in front of the unit)

dB

56

56

-

Anodes

-

1

1

-

Draw-off capacity

 

 

 

 

Storage capacity

l

285

285

-

Maximum temperature setting heatpump

°C

55

55

-

Maximum temperature setting heatpump + electric element

°C

65

65

-

Tcold = 10ºC / Tset = 55ºC (Heatpump function only)

 

 

 

 

30 min T = 28 °C

l

400

400

-

60 min T = 28 °C

l

430

430

-

90 min T = 28 °C

l

460

460

-

120 min T = 28 °C

l

490

490

-

Continuous T = 28 °C

l/h

60

60

-

Heating-up time T= 28°C

min

289

289

-

Tcold = 10ºC / Tset = 55ºC (Heatpump function only)

 

 

 

 

30 min T = 45 °C

l

249

249

-

60 min T = 45 °C

l

268

268

-

90 min T = 45 °C

l

286

286

-

120 min T = 45 °C

l

305

305

-

Continuous T = 45 °C

l/h

37

37

-

Heating-up time T= 45°C

min

465

465

-

Tcold = 10ºC / Tset = 65ºC (Heatpump + electric element)

 

 

 

 

30 min T = 55 °C

l

256

256

-

60 min T = 55 °C

l

283

283

-

90 min = 55°C

l

310

310

-

120 min T = 55 °C

l

337

337

-

Continuous T = 55°C

l/h

54

54

-

Heating-up time T= 55°C

min

398

398

-

Shipping data

 

 

 

 

Empty weight

kg

105

105

-

Weight including packaging

kg

115

115

-

Maximum weight

kg

390

390

-

Width packaging

mm

765

765

-

Height packaging

mm

1945

1945

-

Depth packaging

mm

765

765

-

 

 

 

 

 