UP TO 96% THERMAL EFFICIENCY,DIRECT VENT

The A.O. Smith Cyclone Xi family of products represents the industry’s most technologically advanced commercial water heaters. The innovative Cyclone Xi design takes performance to its highest level with efficiencies of 95% and 96%. Models are available from 120,000 BTUs and now up to 500,000 BTUs. In addition, the Cyclone Xi features an Intelligent Control System making it the smartest water heater in the industry.

Cyclone Xi provides outstanding hot water output, with dramatic savings on operating costs compared to units with standard 80% efficiency. A.O. Smith’s leading-edge engineering delivers conventional power-vent or sealed combustion power direct-vent versatility, low NOx emissions and excellent space-saving characteristics. Powered anodes, standard on all Cyclone Xi models, provide superior tank protection for years of trouble free operation.

INTELLIGENT CONTROL SYSTEM WITH LCD DISPLAY

Exclusive A.O. Smith designed control

Provides detailed water heater status information

Precise temperature control

Built-in diagnostics

Run histrory information

SUBMERGED COMBUSTION CHAMBER,

WITH HELICAL HEAT EXCHANGER COIL

Positioned in center of tank, surrounded by water to virtually eliminate radiant heat loss from chamber

Spiral heat exchanger keeps hot burner gases swirling, uses centrifugal force to maximize efficiency of heat transfer to water in tank

Spiral heat exchanger prevents scale and sediment from forming on water-side surface, which can reduce energy efficiency over time

POWERED ANODES STANDARD ON ALL MODELS

Provides long-lasting tank protection in varying water conditions

Does not require maintenance or inspection

PERMAGLAS® ULTRA COATGLASS LINING

Exclusive process provides superior protection against corrosion

Both sides of heat exchanger coil are lined for protection against flue gas condensate inside coil

MECHANICAL VENTING VERSATILITY

Conventional power-venting or sealed combustion direct venting

Vents vertically or through sidewall

Direct-vent intake and exhaust pipe can terminate separately outside building, or through single opening, using concentric vent assembly

Uses inexpensive PVC, CPVC or ABS pipe for intake and exhaust

HIGH EFFICIENCY PRE-MIX POWERED BURNER

Down-fired pre-mix burner provides optimum efficiency and quiet operation

Top-mounted burner position prevents condensation from affecting burner operation

BTH-120 through BTH-500

Approved, Rule 1146.2 Low NOx for California and Texas

BTH-120-250

BTH-300-500

Page 1 of 4

ACGSS02407

JulyDecember2007R 2007R

UP TO 96% THERMAL EFFICIENCY,DIRECT VENT

OTHER CYCLONE Xi FEATURES

SPACE-SAVING DESIGN FOR INSTALLATION FLEXIBILITY

Reduced footprint, ease of service, protection from water damage in case of flooding

Easy to remove top cover for convenient access to serviceable parts

0˝ installation clearances on sides and rear, 2˝ installation clearance on top, 4˝ alcove installation clearance in front of unit

0˝ clearance to combustibles, approved for combustible floors

FACTORY-INSTALLED TEMPERATURE AND PRESSURE RELIEF VALVE

MAXIMUM HYDROSTATIC WORKING PRESSURE: 160 PSI

HANDHOLE CLEANOUT

Allows easy access to tank interior for cleaning

CODES AND STANDARDS

•Design-certified by UL (Underwriters Laboratories) International, according to ANSZ21.10.3-CSA4.3 standards governing storage-type water heaters

Meets ASHRAE/IESNA 90.1-1999• Design-certified by Underwriters Laboratories to NSF standard 5 for 180° F (62° C) water

Meets SCAQMD Rule 1146.2 for low-NOx emissions

ASME tank construction optional on 120 to 250 model sizes. ASME tank construction standard on 300,400 and 500 models

THREE-YEAR LIMITED TANK WARRANTY

For complete warranty details, consult written warranty shipped with heater, or contact A. O. Smith

INSTALLATION CONSIDERATIONS

1.Condensate Drain – This is a fully condensing water heater and should be located near a drain to permit proper disposal of condensate.

2.Vent Termination – Exhaust gases of this water heater are less than 140° F. In cold climates water vapor in flue

gases will condense into a cloud of vapor where the vent exits the building. This vapor can gradually discolor exterior building surfaces. Vent termination should be located where this vapor cloud and potential discoloration are not a concern. Locating vent termination 6˝ or more from the wall helps vapor from being trapped along a building’s face. To avoid this problem, the vent can be terminated on the roof. Always locate vent termination above the maximum snowline, and do not locate vent termination above a walkway.

3 Air Intake – In cold climates, air intake should be located at least three feet from the vent termination of the water heater and any other appliance vents that discharge moisture-laden air (such as clothes dryers). This will help prevent freeze-over of the intake screen required to prevent foreign objects from entering the intake pipe. Air intake should be located above the maximum snowline.

4.Blockage Sensors – The water heater is equipped with sensors to shut it down if blockage of vent or air intake occurs. A light on the heater’s diagnostic panel will alert service technicians to this problem.

5.Noise – Vent terminal should be located away from bedroom windows or other areas where blower noise will be objectionable. Avoid venting into corners or confined areas, which will amplify sound. Anchoring intake or vent pipe to walls or ceilings can cause noise to be transmitted to living areas, and isolation mounts should be used where anchoring is required.

6 Optional Concentric Vent Kit - Helps to minimize unsightly wall/roof penetrations. BTH-120 - 300 vent kit p/n 9003910105

BTH-400 - 500 vent kit p/n 9006144005

Page 2 of 4