Anritsu MP0122A Data Sheet

MP1570A
1.5 Mbit/s to 10 Gbit/s
SONET/SDH/PDH/ATM Analyzer
Comprehensive Testing of Core Networks from One Compact Portable Analyzer
SDH Edition
2
ADM test
ADM test
MUX/DEMUX test
MUX/DEMUX test
DSn
system
PDH
system
ATM
switch
ADM
ADM
ADM ADM
SONET
OC-1/3/12/48/192
SDH
STM-0/1/4/16/64
ADM
ADM
DS1 DS2 DS3
ADMADM
ATM
network
ATM
network
ATM test
ATM
switch
Subscriber line
Subscriber line
E1 E2 E3 E4
DXC
Cross
connect test
Transmission
test
Optical
Electrical
Wireless
Possible VC4-64c/OC-192c Measurements
The MP1570A analyzer is designed for development, manufacturing, construction, maintenance, and inspection of SDH, SONET, PDH, and ATM equipment and networks. A variety of plug-in units and options are available that offer the flexibility to the users to configure various analysis systems for different applications. The MP1570A is scalable from 1.5 Mbit/s to 10 Gbit/s, and has six slots to install the plug-in units required for SDH and SONET tests at bit different rates. Installing the appropriate combinations of plug-in units can also perform ATM, jitter and wander tests conform to ITU-T O.171/O.172. The MP1570A conforms to the ITU-T recommendations
and Bellcore standards, and supports concatenation mapping, tandem connection, APS measurement, CID measurement and pos measurement. The user can mea­sure 1.5 Mbit/s to 10 Gbit/s signals using a single MP1570A; previously, this required several measuring instruments. The MP1570A has a built-in printer and a 3.5-inch floppy disk drive as standard output devices to print measurement results, and to save and read measurement data to and from the floppy disk (FD), which can also be read on an external PC. The user can also save screen data to the FD. The MP1570A has a "HELP" key function that explains operations, functions and connections.
3
Conforming to Bit Rates from 1.5 Mbit/s to 10 Gbit/s in a Single Unit
The MP1570A conforms to ITU-T Rec. G.703 (2, 8, 34, 139,
1.5, and 45 Mbit/s), G.703 and G.958 (52, 156, 622, 2,488, and 9,953 Mbit/s), and allows the user to select plug-in units for different applications, including SONET, SDH, ATM, jitter and wander tests.
Concatenation Mapping
The MP1570A can perform SDH and SONET tests through the mapping routes from VC4 to VC4-64c and can also core rooter interface tests.
Enhanced SDH and SONET Test Functions
The MP1570A can generate and detect CID patterns (ITU-T Rec. G.958), Tandem Connection patterns (ITU-T Rec. G.707), and Non-frame patterns. Also, APS switching time testing (ITU-T Rec. G.707, G.783, and G.842), Overhead testing and Alarm detection are supported.
Frame Memory and Capture (Option)
The MP1570A can be used to edit and analyze up to 64 frames of data (or up to 26 frames of data at 10 Gbit/s).
IP-over-SONET/SDH (Option)
The IP/PPP packet generation/analysis function uses the frame memory function: The Tx side transmits the SONET/SDH frame data in which the IP/PPP packet is written to the payload (Concatenation*). The Rx side captures the SONET/SDH frame data into the frame memory (option), and analyses the IP packet.
*
STM-64c/OC-192c, STM-16c/OC-48c, STM-4c/OC-12c, STM-1c/OC-3c
Enhanced Through-Modes
The MP1570A enables the user to select one of the four different types of through-modes that it offers: (1) Transparent, (2) Overhead/Overwrite, and (3) Payload/Overwrite. The user can also insert various errors and alarms into the through signals.
Error Analysis (Error Performance)
The MP1570A enables the user to perform error measurement conforming to ITU-T Rec. G.821, M.2100, G.826, M.2101, M.2110, and M.2120.
Frequency and Optical Power Measurements
The MP1570A can measure received frequencies and display measurement results in a graph. If an optical interface plug-in unit is installed, the MP1570A can measure the absolute and relative values of the optical power.
Jitter Generation and Measurement
The MP1570A can measure jitter tolerance and jitter transfer characteristics in conformance with ITU-T Rec. G.823/G.824/G.825/G.958, and Bellcore 253/499. It displays the measurement results as numeric values and as a graph, allowing the user to evaluate them easily.
Various wander generation functions (Option)
Various wander generations for evaluation are available: such as TDEV wander tolerance measurement and TDEV wander transfer characteristics measurement that were regulated by ITU-T, ANSI, Bellcore, and ETSI. Variable-type TDEV wander generation: All 38 types of TDEV masks regulated by ITU-T, ANSI, Bellcore and ETSI are avail­able as preset data. User-specified TDEV mask generation is also available. Phase transient: Changes the phase by an inclination of A (1 – e
–63.7t
). Moreover, the maximum phase shift quantity
can be set freely. (A: maximum phase shift)
ATM Pattern Generation and Measurement
The MP1570A can test, not only the cell performance but also measures the cell delay time, CDV, and cell traffic. For OAM testing, it can generate and detect the AIS, RDI, and continuity check cells for F4 and F5 flows. It can also generate loopback and performance-monitoring cells which conform to ITU-T Rec. I.610.
IP-over-ATM (Option)
The IP packet generation/analysis function uses the ATM unit cell memory function: The Tx side transmits the AAL5 data in which the IP packet is written to AAL5 payload. The Rx side captures the data of cells into the cell memory, and analyses the IP packet.
Supports SDH, SONET, and Japan Modes in One Frame (Option)
The MP1570A allows the user to set up the measurement of SDH, SONET, and 384k Japan mapping in one frame. The user can set a signaling pattern (multi-frame pattern of 8 frames or 64 frames) for Japanese mapping measurement.
4
1
2 3 4
5
6
10
8 9
7
18
1716
11
13
12
14 15
5
Setup: Displays setup screen Test Menu: Displays main test menu screen Result: Displays main measurement results screen Analyze: Displays main analysis screen Cursor Set: Sets data and opens windows for numeric, ASCII and
character input Cancel: Cancels data setting and closes windows for numeric, ASCII and character input
< >: Move cursor or window cursor on screen. At the numeric input window, the and keys increase and decrease the numeric value, respectively.
Start/Stop: Starts and stops measurement Alarm: Inserts alarms (The alarm target is selected at the
Manual screen.) Error: Inserts errors (The error target and single/rate are selected at the Manual screen.)
Help: Displays help screen Alarm/Error: Displays receiver alarms/errors, clock loss,
and power fail measurement results
Printer: Prints screen at built-in or external printer Screen Copy: Outputs screen in bitmap format to floppy
disk
Slot for interface unit Clock Sync Output: Clock output synchronized with PDH or SDH send clock External Clock Input: PDH or SDH external send clock input Receiver Clock Output: Clock output synchronized with receiving data DCC Interface: DCC clock output for send/receive, DCC data I/O an overhead Add/Drop connector External Interface: Any of the RS-232C, GPIB, Ethernet interfaces can be selected as an option. In addition, an optional VGA output can be installed for connecting an external monitor. Printer Floppy disk drive Slots for plug-in units
DCS Input: Data/clock input for SDH output synchronization Trigger Input: Input for APS and each capture measurement Trigger Output: Output for error alarm detection,
send/receive frame or clock Orderwire: Modular jack for connecting orderwire headset
1 2
3 4 5
6 7
8
9
10
11
12
13 14
15
16
17
20
18
19
21 22 23 24
25
<
<
<
<
19
20
21
22
24 25
23
6
SDH, SONET and PDH Measurement
Measurement at Bit Rates from 1.5 Mbit/s to 10 Gbit/s
A mapping route to a bit rate of up to 10 Gbit/s can be set. The MP1570A mainly supports SDH, SONET, Japanese mapping, PDH of the European system and DSn of the North American system for digital communications. For concatenation mapping, a route can be set from STM-1c up to STM-64c. Furthermore, the MP1570A supports a combination of channels. For example, 64 channels of VC4c, 16 channels of VC4-4c, and four channels of VC4-16c.(See figure 1 in page 20)
Mapping
Overhead Setting and Testing
The user can modify and capture the overhead, and test the overhead portion with overhead change, pointer 64 frames, overhead add/drop and overhead bit errors.
Overhead preset
Overhead test-1
Overhead monitor
Overhead test-2
7
APS Function
The user can test the automatic protection switch (APS) by measuring the equipment switching time accurately in milliseconds. The MP1570A also conforms to ITU-T Rec. G.783 and G.841.
APS program data
APS test sub-screen
APS capture
Mixed Payload
At mapping measurement in TUG-3 and AU3, the user can set different mapping for three additional channels other than the target measurement channel.
Mixed payload setting
Tandem Connection
The N1 and N2 bytes can be set and measured.
Tandem
Overhead monitor (Tandem)
8
Various Analysis Functions
The internal optical power meter and frequency counter allows the user to measure optical power and frequency during error and alarm measurement. (Photo A) The MP1570A can capture any SOH or POH (1 byte), K1/ K2 byte, or H1/H2 byte in 1023 frames to analyze errors and alarms, and check APS operation. (Photo B) Measured errors and alarms can be displayed as a graph with a time scale in 1 second, 1 minute, 15 minutes, or 60 minutes. (Photo C)
C: Error/alarm
Pointer V alue Monitoring
Changes in pointer value can be displayed as a graph with values updated in real time.
Pointer monitor
A: Optical power meter
B: Overhead capture
9
MUX/DEMUX Function (Option)
When the MUX/DEMUX option is added, the multiplexing structure including the frame alignment signal can be generated, and multiplexer/demultiplexer measurement can be performed.
STM
C4
C3
C2 C12
C11
139 Mbit/s
45 Mbit/s
34 Mbit/s
8 Mbit/s
2 Mbit/s
1.5 Mbit/s
N
64k
1.5M6M
45M
2M
8M
34M
139M
Dummy 34M
Dummy 384k
Dummy 1.5M
Dummy 2M
Dummy 6M
Dummy 8M
Dummy 2M
384k
Through Modes
One of the three through modes can be selected: (1) Transparent, (2) Overhead/Overwrite, and (3) Payload/Overwrite. The external DS1/DS3/PDH signal can be added/dropped
Transparent
For in-service monitoring
Rx
Tx
Rx
Tx
Overhead Overwrite
Modification of SOH/POH byte. Addition of various errors/alarms.
Payload Overwrite
Rx
Tx
Insertion of internal STS-3SPE/VC4, VT6/TU2, VT2/TU12, VT1.5/TU11 signals
Add/Drop
Add/Drop of external DS1, DS3, PDH signals
External DS1/DS3/PDH
Non Frame Pattern/CID Pattern
Frames can be set on/off at all bit rates. CID pattern can generate or analysis at SDH/SONET measurement.
10
Enhanced Error/Alarm Simulation
The MP1570A can generate normal and abnormal frames alter­nately to test the frame synchronization function of terminal equipment. (This is an SDH FAS error addition function.)
Normal frame word (N) Abnormal frame word (M)
Alternative
N=1 to 15
Example of FAS error
M=0 to 15
Easily operated pointer sequence test (combined jitter measurement)
Able to generate the justification pattern conforming to ITU-T G.783 from the transmission equipment side, and simultane­ously make the tributary signal offset variable. This makes the combined jitter test possible.
MP1570A
Jitter data
1.5M 2M 8M
34M 45M
139M
PDH
STM-N
Pointer sequence + payload offset
Combined jitter measurement
11
Jitter and Wander
Automatic Measurement with Easy-to-Understand
Graphs
Jitter tolerance, jitter transfer and jitter frequency can all be measured automatically. And since the data can be saved to floppy disk in the text format, data management is made simple by using a personal computer. Masks conforming to ITU-T Rec. G.823/G.824/G.825/G.958 are provided as preset data. Measurement is performed simply by pressing the start key. Furthermore, the operator can also set any other mask as necessary.
Jitter transfer measurement that is able to set the selective bandwidth
In jitter standard such as ITU-T, ANSI, Bellcore, and ETSI, the bandwidth selective regulation is still unclear for jitter transfer measurement evaluation. This equipment selects the band­width selection at the jitter transfer measurement in the range of 1 to 30 Hz. It responds immediately when the standard such as ITU-T, is reconsidered.
Mapping Jitter Measurement Method
Mapping jitter can be measured just by making a simple con­nection with the MP1570A.
MP1570A
1.5 MHz/1.5 Mbit/s signal 2 MHz/2 Mbit/s signal
2/34/139/1.5/45M
SDHADM ADM
Extended jitter quantity and frequency shift monitoring
Able to measure jitter/wander and error/alarm at the same time, so that the relationship of error/alarm generation and jitter can be analyzed.
Through jitter function (only SONET/SDH)
Able to generate the jitter by through, while monitoring the input jitter quantity.
Input signal Output signal
Rx jitter measurement
Tx jitter generation
Variable-type jitter measurement filter based on DSP
(up to 622 Mbit/s jitter measurement)
Filters regulated by ITU-T G series, such as ITU-T O.171/O.172, ANSI, Bellcore, and ETSI are available as preset data. The user can set the setting value of the filter freely and analyze the cause of jitter trouble.
Variable filter
HP
Jitter measurement bandwidth(Hz)
LP
12
Wander Conforming to ITU-T Rec. G.823/G.824/G.825
Since MP1570A can generate wander [up to 57,600 UIp -p/10 µHz (at 2488M)], jitter and wander tolerance mask evaluation conforming to ITU-T Rec. G.823/G.824/G.825 is possible. (usable wander tolerance mask at manual measurements)
Various wander application software
It is possible to perform MTIE and TDEV measurements on real time by MX150001B wander application and external PC. Various wander measurements can also be performed, such as hold over, wander tolerance (TDEV), and wander transfer characteristics (TDEV). Real time wander measurement: Real time wander measurements, such as frequency offset, frequency drift rate, MTIE, TIE, and TDEV Wander tolerance (TDEV) measurement: Evaluates the wander tolerance by TDEV wander modulation Wander transfer (TDEV) measurement: Evaluates the wander transfer characteristics by TDEV wander modulation
[GPIB or RS-232C]
MX150001B Wander (MTIV, TDEV) Measurement Application Software
PC
CSM: Clock Supply Module NE: SDH/SONET Network Element
MP1570A
SDH/SONET data
1.5 MHz signal
Wander reference input
SDH/
SONET
network
NE
NE
CSM
MTIE/TDEV Measurement
MTIE/TDEV analysis can be performed by running the MX150001B Application Software on an external personal computer. Data collected in the field can be saved to floppy disk and taken to the office for easy analysis and management on a computer.
A0 A1 A2 A3 A4
f0 f12 f11 f10 f9 f8
f1
f3f2f4
Jitter or wander amplitude (p-p)
Slope:20 dB/decade
Jitter frequency
13
IP/PPP header setting
Able to set the value of each header optionally when selecting IPv4 or IPv6. Calculates FCS or header checksum automatically.
IP-over-SONET/SDH
Programs IP/PPP at will, transmits it, picks PPP packet from capture memory (option), and displays it. And supports high-speed POS router evaluation.
PPP packet transmission and real time count
Transmits the three types of packets (can be set separately) by optional sequence (the idle length between each packet can be set simultaneously.). Displays the number of Tx packets and Rx ppp packets at real time.
PPP packet capture and display
Samples PPP packet from the capture memory, and displays IP header. Detects FCS error and displays it in red.
Packet data list
Detail packet data
14
IP header setting
Able to select IPv4 or IPv6, and set the value of each header at will. Calculates header checksum automatically.
IP-over-ATM
Programs IP in the AAL5 payload at will, transmits it, picks the IP packet from the cell capture memory, and displays it. And supports ATM router evaluation.
IP packet transmission
At ATM/AAL5 testing, it transmits the edited IP packet by just setting AAL5.
IP packet capture and display
All IP packets (maximum 2016 packets) captured into the cell memory are displayed.
Packet data list
Detail packet data
15
Supports ATM from 1.5M to 622M rates
TC layer mappings of 622M, 156M, 52M, 139M, 45M, 34M, 2M and 1.5M are supported along with ATM mappings of O.191, AAL1, AAL2, AAL3/4, and AAL5, which makes the MP1570A ideal for various combinations of layers.
CPCS Layer Data Creation
The cell format supports both ATM (O.191, user program) and each AAL type. PRBS, word pattern, edit pattern, and time stamp can be inserted as the payload for each format. In particular, CPS packet editing is possible for AAL2, and CPCS-PDU editing is also possible for AAL3/4 and AAL5. In addition, CBR, burst, Poisson, and sawtooth waveforms can also be selected as the cell generation timing, making the traffic appear even more like an actual line.
ATM
Cell header Payload
Payload Payload
PayloadPointerSNPSNCSI
Payload
PPT UUI HEC
Payload
Payload
CPI B tag BA size
LICID
MID LI CRC10SNST MID
LIPAD
CRC10
CPI LengthCPCS-UUPAD
CRC10
ALPAD E tag Length
SNST
Payload
PPT UUI HECLICID
P PADSNOSF
SN TS TCPT CRC16
ATM (O.191
)
ATM (user program
)
AAL2
AAL3/4
AAL5
AAL1
16
Simultaneous Monitoring of 1023 Channel Cells and
Non-conforming Cells
The VPI/VCI for 1023 channels can be detected automatically, and the presence/absence of alarms, cell count, and non-con­forming cell count can be displayed graphically, for easy com­parison of line channel traffic.
1- and 2-Point CDV in Conformance with I.356
When measuring delay in cell traffic, either 1-point CDV or 2-point CDV conforming to ITU-T Rec. I.356 can be selected according to the conditions.
Simultaneous Display of Error Cells, Inserted Error
Cells and Lost Cells
The error/alarm generation conditions can be displayed both numerically and graphically to give a visual impression of the traffic conditions.
Traffic Monitoring
The constantly changing traffic can be displayed as a graph for the selected-one-channel VPI/VCI.
17
Specifications
Bit rate 2.048, 8.448, 34.368, 139.264 Mbit/s Level/waveform Conforms to ITU-T G.703 (with 20 dB monitoring point)
BNC (75 , unbalanced), 3-pin Siemens (120 , balanced)
Connectors
2.048 Mbit/s: HDB3 (balanced/unbalanced)
8.448, 34.368 Mbit/s: HDB3 (unbalanced)
139.264 Mbit/s: CMI (unbalanced)
Clock Internal (accuracy: ±7 ppm, jitter unit not installed), external (ECL [AC] 50 ), received signal
Unframed: 2, 8, 34, 139 Mbit/s
Frame format Framed: 2 Mbit/s (with/without CRC-4 at channels 30/31, G.704), 8 Mbit/s (G.742), 34 Mbit/s (G.751), 139 Mbit/s (G.751),
MUX/DEMUX (Option 06)
PRBS: 211– 1, 215– 1, 220– 1, 223– 1 (O.151)
Test patterns Invert: On/off
Word: 16-bit programmable, all 0, all 1 Bit (all, test pattern), code, E-bit
Error addition Timing: Single, rate (1E–3, 1E–4, 1E–5, 1E– 6, 1E–7)
FAS: n in 16 (n: 1 to 4), all LOS, LOF, AIS, RDI, RDI (MF)
Alarm addition
Timing: All Mode: Single, repeat, manual
In-service
Errors: Frame, code, CRC-4, E-bit Alarms: Power-fail, LOS, AIS, LOF, MF loss, RDI, RDI (MF)
Measurements Error performance: G.821 (inc. Annex D), M.2100, G.826
Out-of-service
Errors: Frame, code, CRC-4, E-bit, bit Alarms: Power-fail, LOS, AIS, LOF, MF loss, RDI, RDI (MF), sync loss
Error performance: G.821 (inc. Annex D), M.2100, G.826 LEDs LOS, AIS, LOF, MF loss, RDI, RDI (MF), sync loss, errors Monitor Frame word Trouble search Auto search for errors/alarms in all measured channels Delay measurement 0 to 1 s Auxiliary interface Clock sync output, frame sync output, error output
MP0121A 2/8/34/139/156M
*
1 Unit
*
1: Built-in 156M CMI (electrical) interface
18
MP0122A 1.5/45/52M
*
1
Unit, MP0122B 1.5/45/52/52M
*
2
(1.31) Unit
Bit rate 1.544, 44.736 Mbit/s
1.544 Mbit/s: ANSI T1.102 (with 20 dB monitoring point), 0/655 ft
Level/waveform
44.736 Mbit/s: ANSI T1.102 (with 20 dB monitoring point), 0/450/900 ft BNC (75 , unbalanced), Bantam (100 , balanced)
Connectors
1.544 Mbit/s: AMI/B8ZS (balanced), 44.736 Mbit/s: B3ZS (unbalanced)
Clock Internal (accuracy: ±7 ppm, jitter unit not installed), external (ECL [AC] 50 ) received signal
Unframed: 1.5, 45 Mbit/s
Frame format
Framed: 1.5 Mbit/s (D4, ESF, Japan ESF
*
3
), 45 Mbit/s (M13, C-bit), MUX/DEMUX (Option 07)
PRBS: 2
11
– 1, 2
15
– 1, 2
20
– 1 (zero suppress), 2
20 –
1, 2
23 –
1 (O.151)
Test patterns Invert: On/off
Word: 16-bit program, all 0, all 1, 3 in 24 (1.5 Mbit/s) Bit (all, test pattern), code, parity, CRC-6, C-bit, REI
Error addition Timing: Single, rate (1E–3, 1E–4, 1E–5, 1E– 6, 1E–7)
FAS (45 Mbit/s): n in 16 (n: 1 to 4), all
X-bit setting 00, 01, 10, 11
LOS, LOF, AIS, RDI
Alarm addition
Timing: All Mode: Single, repeat, manual
In-service
Errors: FAS, code, parity, CRC-6, C-bit, REI Alarms: Power-fail, LOS, AIS, LOF, RDI
Measurements Error performance: G.821 (inc. Annex D), M.2100, G.826
Out-of-service
Errors: FAS, code, parity, CRC-6, C-bit, REI, bit Alarms: Power-fail, LOS, AIS, LOF, RDI, sync loss
Error performance: G.821 (inc. Annex D), M.2100, G.826 LEDs LOS, LOF, AIS, RDI, sync loss, errors Trouble search Auto search for errors/alarms in all measured channels Delay measurement 0 to 1 s Auxiliary interface Clock sync output, frame sync output, error output
*
1: Built-in 52M B3ZS (electrical) interface
*
2: Built-in 52M B3ZS (electrical) and optical interfaces
*
3: Mounted Option 09 (Japan mapping)
19
Bit rate 51.84, 155.52, 622.08, 2488.32, 9953.28 Mbit/s
52M (electrical: B3ZS)
*
1
: ANSI T1.102, 0/450 ft 52M (optical): As per MP0122B unit optical interface specifications 156M (electrical: CMI)
*
2
: ITU-T G.703
Level/waveform 156M (optical): As per optical 156M/622M unit specifications
622M (electrical/optical): As per optical 156M/622M unit and NRZ unit specifications 2488M (electrical/optical): As per 2.5G unit and 2.5G/10G unit specifications 9953M (electrical/optical): As per 2.5G/10G unit specifications
Clock
Internal (accuracy: ±3.5 ppm, jitter unit not installed), Lock (2 MHz, 1.5 MHz, 64 kHz + 8 kHz, 2 Mbit/s, 1.5 Mbit/s), external (ECL [AC] 50 , 9953M: 1.02 to 0.58 Vp-p, 50 ), received signal
Frame SDH/SONET, CID pattern, non-frame Mapping See Fig. 1 Through Trance parent, over head overwrite, payload overwrite
PRBS: 2
11
–1, 2
15
–1, 2
20
–1 (zero suppress, MP0122A/B installed), 2
20
–1, 2
23
–1, 2
31
–1 (only concatenation mapping 16c/64c,
Test patterns
conform to O.151) Invert: On/off Word: 16-bit programmable, all 0, all 1
Bit all (all, test pattern), FAS, B1, B2, B3, BIP-2, MS-REI, HP-REI, LP-REI Timing: Single, single (burst) bit (1 to 64000), rate (1E–3, 1E–4, 1E–5, 1E–6, 1E– 7, 1E–8, 1E– 9)
Error addition
User program AE-B [A: 1.0 to 9.9 (step: 0.1), B: 2 to 10] Alternative: Error frame (0 to 8000), normal frame (1 to 8000)
LOS, LOF, MS-AIS, MS-RDI, AU-AIS, AU-LOP, HP-SLM, HP-TIM, HP-RDI, HP-UNEQ, TU-AIS, TU-LOP, TU-LOM, LP-SLM, LP-TIM, LP-RDI, LP-UNEQ, LP-RFI
Alarm addition
Timing: Single, single (burst) frame Alternative: Alarm frame (0 to 8000), normal frame (1 to 8000), all
Mode: Single, repeat, manual In-service/Out-of-service
Errors: B1, B2, B3, BIP-2, MS-REI, HP-REI, LP-REI
Measurements Alarms: Power-fail, LOS, LOF, OOF, MS-AIS, MS-RDI, AU-AIS, AU-LOP, HP-SLM, HP-TIM, HP-RDI, HP-UNEQ, TU-AIS,
TU-LOP, TU-LOM, LP-SLM, LP-TIM, LP-RDI, LP-UNEQ, LP-RFI Error performance: G.826, M2101, M2110, M2120 Preset: Alarm measurement condition
LEDs
LOS, LOF, OOF, MS-AIS, MS-RDI, AU-AIS, AU-LOP, HP-RDI, HP-SLM, TU-AIS, TU-LOM, TU-LOP, LP-RDI, LP-RFI, LP-SLM, Tandem, sync. loss, errors
N1 byte (Type 1, Type 2), N2 byte
Tandem connection Errors: N2 BIP-2, TC-REI, OEI, IEC
Alarms: VC-AIS, ISF, FAS, HP-Incoming-AIS, HP-TC-RDI, HP-ODI, LP-Incoming-AIS, LP-TC-RDI, LP-ODI
Justification
AU pointer, TU pointer, C, C1/C2 Measurement: NDF, +PJC, –PJC, Cons, C, C1/C2
Monitor SOH, POH, K1/K2, pointer, path trace (TIM alarms detectable), Tandem, payload
Signal of opposites polarity, regular with double, regular with missing, double of opposites polarity, 87-3/26-1 (normal, add,
Pointer sequence cancel), continuous pattern (normal, add, cancel), single pointer adjustment, maximum rate pointer burst, phase transient pointer
burst, initialize period polarity, cooldown period
Over head capture SOH/POH (any 1 byte), H1/H2, K1/K2 Dummy channel setting
Payload: Dummy, copy, mixed payload Setting: POH, pathtrace, SS bit, Tandem
Simultaneous measurement
VC2, VC12, VC11
Trouble search Auto search for errors/alarms in all measured channels
Measurement period: 0.5, 1, 2, 5, 10 s
Delay Measurement range: 0 to 999 µs, 1.0 to 999.9 ms, 1.0 to 10.0 s, time out
Display accuracy: ±5 µs (0.5, 1 s), ±50 µs (2, 5, 10 s) Switching time measurement
Measurement range: 1 to 2000 ms, >2000 ms Trigger
Internal: B1, B2, B3, BIP-2, MS-REI, HP-REI, LP-REI, MS-AIS, AU-AIS, AU-LOP, HP-RDI, TU-AIS, TU-LOM, TU-LOP, LP-RDI,
LP-RFI, Bit
APS (K1/K2)
External: Measures trigger input signal (active high) Threshold: Specify non-error alarm between 1 ms, 10 ms, 100 ms Sequence generation: 2 to 64 word, repeat (8000 frame) Sequence capture: 2 to 64 word, repeat (8000 frame)
Frequency measurement
Range: ±100 ppm, Accuracy: ±3.5 ppm (jitter unit not installed) OH change: SOH/POH 1 byte, K1/K2, RSOH, MSOH, SOH, POH (except B1, B2, B3, BIP-2)
PTR 64 frame: AU pointer, TU pointer
Timing: Single, repeat (2 to 64)
Over head test Setting: PTR, NDF, +PJC, –PJC
OH BERT: SOH/POH 1 byte (exclude B1, B2, B3, BIP-2), D1-D3, D4-D12
Test pattern: 2
11
–1, 2
15
–1
OH add/drop: SOH/POH 1 byte, D1-D3, D4-D12 (exclude B1, B2, B3, BIP-2 additional type)
52/156/622/2488/9953M
20
139M (Async.)
1
Bulk
1
34M (Async.)
1
34M (Sync.)
1
45M (Async.)
3
Bulk
3
Bulk 6M (Async.) 6M (Bit sync.) mc
x 3
x 7
x 7
x 3
x 4
x 3
x 4
x 4
STM-4 STM-1
STM-0
AUG
AU-4 VC-4
TUG-3 TU-3
VC-3
TU-2 VC-2
TUG-2
AU-3 VC-3
1: Requires MP0121A
2: Requires Japan mapping (Option 09)
3: Requires MP0122A/B
4: Requires MU150000A
5: Requires MU150000A, MU150008A, MU150009A or MU150010A
TU-12
TU-11
VC-12
VC-11
STM-16
VC4-64c
STM-64c
4
STM-64
x 16
x 64
2M (Async.)
1
2M (Bit sync. F)
1
2M (Bit sync. L)
1
2M (Byte sync. F)
1
2M (Byte sync. L)
1
Bulk
1
1.5M (Async.)
1.5M (Bit sync. F)
1.5M (Bit sync. L)
1.5M (Byte sync. F)
1.5M (Byte sync. L) Bulk
Bulk
VC4-16c
STM-16c
4,∗5
Bulk
384k (data)
2
384k (voice)
2
Byte (data)
2
Byte (voice)
2
x 4
VC4-4c
STM-4c
Bulk
x 4
VC4
STM-1c
Bulk
Fig. 1 Mapping structure
Printer Internal, external Internal memory Measurement settings memory: 10, Graphics memory: 15 Others
FDD, RS-232C (Option 01)
*
1
, GPIB (Option 02)
*
1
, Ethernet (Option 03)
*
1
, video output (Option 04)
*
1
, buzzer, clock, help, screen copy
EN61326: 1997/A1, 1998 (Class A)
EMC EN61000-3-2: 1995/A2, 1998 (Class A)
EN61326: 1997/A1, 1998 (Annex A)
LVD EN610101-1: 1993/A2, 1995 (Installation Category ΙΙ, Pollution degree 2) Dimensions and mass 320 (W) x 177 (H) x 350 (D) mm, 10 kg approx. (excluding plug-in units and options) Power 100 to 240 Vac, 47.5 to 63 Hz, 500 VA Temperature 0˚ to +40˚C
General
Japan mapping (option 09)
VC11 Signaling (8-multiframe, 64-multiframe setting)
Frame memory/capture
Memory size: 64 frame (156M, 622M, Option 13), 64 frame (MU150008A-01/150009A-01/150010A-01, 2.5G),
26 frame (MU150000A-01, 2.5G/10G) Insert/extract Bit rate: 10G (52M, 156M), 2.5G (52M, 156M) Payload offset ±100 ppm/0.1 ppm step Auxiliary interface Clock sync output, trigger input, trigger output, DCC interface (V.11), orderwire, receive clock output
*
1: The video output, RS-232C, GPIB and Ethernet options cannot all be used simultaneously.
Only the video output + RS-232C, or video output + GPIB, or RS-232C + GPIB board, or Ethernet board combinations support simultaneous use, so change the board combinations according to the purpose.
*
1: Mounted MP0122A/B
*
2: Mounted MP0121A
21
Bit rate 155.52, 622.08, 2488.32, 9953.28 Mbit/s
Flag, address, control: Any settable Protocol: 8/16 bit selectable and any settable
PPP setting (RFC1662)
FCS: 16/32 bit selectable and auto calculate Information: IPv4/IPv6 selectable and any settable
Any setting: Version, IHL, TOS, total length, ID, flags, flagment offset, TTL, protocol, address (source, destination)
IPv4 setting (RFC0791) Header checksum: Auto calculate
Data byte: All 0, all 1, 8 bits program, single PRBS 7, user program (max. 65535 byte)
IPv6 setting (RFC1883)
Any setting: Version, priority, flow label, payload length, next header, hop limit, address (source, destination) Data byte: All 0, all 1, 8 bits program, single PRBS 7, user program (max. 65535 byte)
Packect transmission 1 to 3 in IP/PPP (independently), IP/PPP sending pattern, packet sending interval (max. 100000 bytes), single/repeat, sending on/off, setting scramble (X
43
+ 1) on/off, control escape auto insertion, FCS error insertion (single), number of packet count display
Packet receiving/analysis PPP frame calculation (count), scramble (X43+ 1) on/off setting, automatic analysis of control escape. Frame/capture memory
(option) required data captured into the capture memory (max. 64 frames
*
2
), IPv4/IPv6 select, IP address filter set
IP-over-SONET/SDH (option)
*
1
*
1: The frame/capture memory (option) is required.
*
2: Max. 26 frames at 2488/9953 Mbit/s when MU150000A is inserted.
Bit rate 155.52, 622.08 Mbit/s AAL5 edit pattern IPv4/IPv6 selectable
Any setting: Version, IHL, TOS, total length, ID, flags, flagment offset, TTL, protocol, address (source, destination)
IPv4 setting (RFC0791) Header checksum: Auto calculate
Data byte: All 0, all 1, 8 bit program, single PRBS 7, user program (max. 65535 bytes)
IPv6 setting (RFC1883)
Any setting: Version, priority, flow label, payload length, next header, hop limit, address (source, destination)
Data byte: All 0, all 1, 8 bits program, single PRBS 7, user program (max. 65535 bytes) Packet sending Follow with AAL5 distribution setting Packet receiving/analysis Displays the IP packet from the data captured into cell capture memory (max. 2016 cells), IPv4/IPv6 selectable
IP-over-ATM (option)
*
3
*
3: MP0123AATM Unit is required.
22
MU150005A /150006A/150007A Jitter Units
MU150005A: 2.048, 8.448, 34.368, 139.264, 155.52, 622.08 Mbit/s
Bit rate MU150006A: 1.544, 44.736, 51.84, 155.52, 622.08 Mbit/s
MU150007A: 1.544, 2.048, 8.448, 34.368, 44.736, 139.264, 51.84, 155.52, 622.08 Mbit/s Conform to ITU-T O.171/O.172
Modulation frequency: 0.1 Hz to 6 MHz Amplitude: 0 to 404.0 UIp-p Resolution:0.001 UIp-p (2 UI range), 0.01 UIp-p (16 UI range), 0.1 UIp-p (80 UI range), 0.2 UIp-p (400 UI range)
Jitter generation
Accuracy
2 UI range: (±Q% of setting) ±0.02 UIp-p, 16 UI range: (±Q% of setting) ±0.2 UIp-p, 80 UI range: (±Q% of setting) ±1.2 UIp-p, 400 UI range: (±Q% of setting) ±6 UIp-p
Bit rate f1 f2 f3 f4 f5 f6 f7
(Mbit/s) (Hz) (Hz) (kHz) (kHz) (kHz) (kHz) (kHz)
1.544 130 630 3.2 25 100
2.048 300 1.5k 7.5 60 240
8.448 1.1k 5.5k 28 220 880
34.368 2.5k 13k 63 500 5000
44.736 2.5k 13k 63 500 5000
139.264 9k 45k 230 1800 6000
51.84 2.5k 13k 63 500 5000
155.52 7.5k 38k 190 1500 6000
622.08 3k 15k 75 600 6000
Bit rate (Mbit/s) Error Q Frequency range
±12% 0.1 to 2 Hz
1.544 ±8%2 Hz to 100 kHz
±12% 0.1 to 10 Hz
2.048 ±8% 10 Hz to 240 kHz
±12% 0.1 to 20 Hz
8.448 ±8% 20 Hz to 880 kHz
±12% 0.1 to 100 Hz
34.368 ±8% 0.1 to 500 kHz ±12% 500 kHz to 5 MHz ±12% 0.1 to 2 Hz
44.736
±8% 2 Hz to 5 MHz
±12% 0.1 to 100 Hz
±8% 0.1 to 500 kHz
139.264 ±12% 0.5 to 2 MHz
±15% 2 to 6 MHz ±12% 0.1 to 300 Hz
51.84 ±8% 300 Hz to 5 MHz
±12% 0.1 to 500 Hz
155.52 ±8% 0.5 to 500 kHz ±12% 0.5 to 6 MHz ±12% 0.1 Hz to 1 kHz
±8%1 to 500 kHz
622.08 ±12% 0.5 to 2 MHz
±15% 2 to 6 MHz
f1 f2 f3 f4 f5 f6 f7
Modulation frequency
0.20
0.50
0.60
2.020
16.16
80.8
400.0
2 Ul range
16 Ul range
80 Ul range
400 Ul range
400 Ul range
80 Ul range 16 Ul range
2 Ul range
–20 dB/dec
–20 dB/dec
–20 dB/dec
–20 dB/dec
[UIp-p]
(Hz)
Jitter modulation
23
Range: ±999.9 ppm/0.1 ppm steps (jitter off), ±100 ppm/0.1 ppm steps (jitter on/off)
Frequency offset
Accuracy: ±0.1 ppm after power-on, calibrates after 60 min warm-up, 23˚ ±5˚C
Auxiliary interface External modulation input, External 5/10 MHz reference input, Jitter clock/Jitter reference output, Wander reference output
Conform to ITU-T O.171/O.172 Modulation frequency: 0.1 Hz to 5 MHz Amplitude: 0.0 to 400 UI (800 UI: at 622M) Resolution:
0.001 UIp-p/0.001 UIrms (2 UI range), 0.01 UIp-p/0.01 UIrms (8 UI/20 UI range), 0.2 UIp-p (400 UI range), 0.5 UIp-p (800 UI range)
Jitter measurement
F1 F2 F3 F4
Modulation frequency (Hz)
A1
A2
[2/8 UI range]
[UIp-p]
Jitter measurement
Bit rate
A1 A2 F1
F2 F3 F4
(Mbit/s)
(UIp-p)
(UIp-p) (Hz) (Hz) (Hz) (Hz)
—Full Wide Full Wide Full Wide
1.544 0.5 8 2 0.1 10 1.25k 5k 20k 40k
2.048 0.5 8 2 0.1 10 3.75k 15k 60k 100k
8.448 0.5 2 10 50k 200k 400k
34.368 0.5 8 2 0.1 10
18.75k
75k 300k 800k
44.736 0.5 8 2 0.1 10 25k 100k 400k 400k
139.264 0.5 8 2 0.1 10 50k 200k 800k 3.5M
51.84 0.5 8 2 1 10 25k 100k 400k 400k
155.52 0.4 8 2 1 10 25k 100k 500k 1.3M
622.08 0.3 8 2 1 10 75k 300k 2M 5M
Bit rate
A1 F1
F2 F3 F4
(Mbit/s)
(UIp-p)
(Hz) (Hz) (Hz) (Hz)
—Full Wide
1.544 0.67 0.1 1 600 15k 15k
2.048 1.67 0.1 1 1.5k 18k 18k
8.448 1.43 0.1 1 5k 70k 70k
34.368 0.5 0.1 1 8k 300k 300k
44.736 0.5 0.1 1 10k 400k 400k
139.264 0.5 0.1 1 20k 800k 1.2M
51.84 0.5 1 1 10k 400k 400k
155.52 0.4 1 1 10k 500k 1.3M
622.08 0.3 1 1 30k 2M 5M
Bit rate A1 A2 F1∗∗F2 F3
(Mbit/s)
(UIp-p) (UIp-p)
(Hz) (Hz) (Hz)
1.544 20 400 0.1 10 200
2.048 20 400 0.1 10 200
8.448 20 400 0.1 10 200
34.368 20 400 0.1 10 200
44.736 20 400 0.1 10 200
139.264 20 400 0.1 10 200
51.84 20 400 0.1 10 200
155.52 4 400 0.1 10 1k
622.08 4 800 0.1 10 2k
F1 F2 F3 F4
A1
[20 Ul range]
[UIp-p]
20
(
7.07
)
Jitter measurement
Modulation frequency (Hz)
F1 F2 F3
A1
A2
[400/800 Ul range]
[UIp-p]
Modulation frequency (Hz)
Jitter measurement
F1 = 100 Hz at RMS
∗∗
: Full band only
F1 = 100 Hz at RMS
24
Filter: Conform to O.171/O.172, LP, HP0 + LP, HP1 + LP, HP2 + LP, HP + LP, user
Accuracy (UIp-p, UI+p, UI-p)
2 UI range: ±R% of reading ±W UIp-p, 20 UI range: ±R% of reading ±W UIp-p, 400 UI range: ±R% of reading ±W UIp-p, 800 UI range: ±R% of reading ±W UIp-p
Fixed error [W]
UIp-p
Jitter measurement
Bit rate
Pseudo-random signal
(Mbit/s)
HP1 + LP HP2 + LP
2 UI 8 UI 20 UI
400/800 UI
2 UI 8 UI 20 UI
Bit length
1.544 0.040 0.08 0.22 3.5 0.025 0.05 0.15 2
20
– 1
2.048 0.040 0.08 0.22 3.5 0.025 0.05 0.15 2
15
– 1
8.448 0.040 0.22 3.5 0.025 0.15 2
15
– 1
34.368 0.040 0.08 0.22 3.5 0.025 0.05 0.15 2
23
– 1
44.736 0.040 0.08 0.22 3.5 0.025 0.05 0.15 2
15
– 1
139.264 0.040 0.08 0.30 5.0 0.025 0.05 0.15 2
23
– 1
Bit rate
Clock signal
(Mbit/s)
HP1 + LP HP2 + LP
2 UI 8 UI 20 UI
400/800 UI
2 UI 8 UI 20 UI
1.544 0.015 0.03 0.10 1.6 0.010 0.02 0.08
2.048 0.015 0.03 0.10 1.6 0.010 0.02 0.08
8.448 0.015 0.10 1.6 0.010 0.08
34.368 0.030 0.06 0.18 2.8 0.020 0.04 0.15
44.736 0.030 0.06 0.18 2.8 0.020 0.04 0.15
139.264 0.030 0.06 0.22 3.8 0.020 0.04 0.20
Bit rate
SONET/SDH signal
(Mbit/s)
HP1 + LP HP2 + LP
2 UI 8 UI 20 UI
400/800 UI
2 UI 8 UI 20 UI
Container
51.84e 0.070 0.14 0.30 5.0 0.050 0.10 0.20 VC3
51.84o 0.070 0.14 0.30 5.0 0.050 0.10 0.20 VC3
155.52e 0.070 0.14 0.30 5.0 0.025 0.05 0.20 VC4
155.52o 0.070 0.14 0.30 5.0 0.050 0.10 0.20 VC4
622.08 0.100 0.20 0.30 10.0 0.050 0.10 0.20 VC4-4c At PRBS 2
23
– 1
Bit rate
Clock signal
(Mbit/s)
HP1 + LP HP2 + LP
2 UI 8 UI 20 UI
400/800 UI
2 UI 8 UI 20 UI
51.84e 0.050 0.10 0.22 3.8 0.030 0.06 0.20
155.52e 0.050 0.10 0.22 3.8 0.030 0.06 0.20
622.08 0.050 0.10 0.22 5.0 0.030 0.06 0.20
Bit rate HP0 HP1 HP2 HP2' HP LP (Mbit/s) (Hz) (Hz) (Hz) (Hz) (Hz) (Hz)
1.544 10 10 8k 12k 40k
2.048 10 20 18k 700 12k 100k
8.448 10 20 3k 80k 12k 400k
34.368 10 100 10k 12k 800k
44.736 10 10 30k 12k 400k
139.264 10 200 10k 12k 3.5M
51.84 10 100 20k 12k 400k
155.52 10 500 65k 12k 1.3M
622.08 10 1k 250k 12k 5M
25
Frequency error [R]
UIrms
2 UI range: ±R% ±Y UIrms, 20 UI range: ±R% ±Y UIrms
Fixed error [Y]
UIrms
Jitter measurement
Frequency error [R]
Hit measurement Count, Seconds, % free seconds Frequency measurement
Resolution: 0.1 ppm, Display: Hz or ppm (After power-on, calibrates after 60 min warm-up, 23˚ ±5˚C)
Auxiliary interface Demodulation output, Clock/Reference input
Jitter tolerance measurement: Evaluates jitter tolerance point automatically Jitter sweep measurement: Conforms to high-speed jitter tolerance evaluation for mass production, etc.
Jitter auto measurement Jitter transfer measurement: High dynamic range measurement by selective level method (variable)
Jitter frequency measurement: Measures the mapping jitter automatically Frequency sweep measurement: Measures the jitter tolerance automatically while changing the offset
Modulation frequency: 10 µHz to 10 Hz (sine wave) Amplitude: 0 to 400,000 UI (10 UIp-p steps)
Line wander generation
Frequency error Frequency range
±10% 0.1 to 20 Hz
±7% 20 Hz to 300 kHz
±8% 300 kHz to 1 MHz ±10% 1 to 3 MHz ±15% 3 to 5 MHz
Bit rate
Pseudo-random signal
(Mbit/s)
HP + LP
2 UI 8 UI 20 UI
Bit length
1.544 0.006 0.02 0.04 2
20
– 1
2.048 0.006 0.02 0.04 2
15
– 1
8.448 0.006 0.04 2
15
– 1
34.368 0.008 0.02 0.05 2
23
– 1
44.736 0.008 0.02 0.05 2
15
– 1
139.264 0.008 0.02 0.05 2
23
– 1
Bit rate
Clock signal
HP + LP
(Mbit/s)
2 UI 8 UI 20 UI
1.544 0.004 0.02 0.03
2.048 0.004 0.02 0.03
8.448 0.004 0.03
34.368 0.006 0.02 0.04
44.736 0.006 0.02 0.04
139.264 0.006 0.02 0.04
Frequency error Frequency range
±10% 0.1 to 20 Hz
±7% 20 Hz to 300 kHz
±8% 300 kHz to 1 MHz ±10% 1 to 3 MHz ±15% 3 to 5 MHz
At PRBS 2
23
– 1
Bit rate
SONET/SDH signal
(Mbit/s)
HP + LP
2 UI 8 UI 20 UI
Container
51.84e 0.010 0.02 0.06 VC3
51.84o 0.010 0.02 0.06 VC3
155.52e 0.010 0.02 0.06 VC4
155.52o 0.010 0.02 0.06 VC4
622.08 0.012 0.03 0.08 VC4-4c
Bit rate
Clock signal
(Mbit/s)
HP + LP
2 UI 8 UI 20 UI
51.84e 0.008 0.02 0.05
155.52e 0.008 0.02 0.05
622.08 0.010 0.02 0.06
f0 f1 f2
A1
A0
[UIp-p]
–20 dB/dec
C
BA
(Hz)
Bit rate f0 f1 f2 A0 A1 (Mbit/s) (µHz) (mHz) (Hz) (UIp-p) (UIp-p)
1.544 10 20 10
400,000
800
2.048 10 20 10
400,000
800
8.448 10 200 10
400,000
8,000
34.368 10 400 10
400,000
16,000
44.736 10 400 10
400,000
16,000
139.264 10 2,000 10
400,000
80,000
51.84 10 400 10
400,000
16,000
155.52 10 2,000 10
400,000
80,000
622.08 10 400 10
400,000
16,000
26
Accuracy: ±Q% of setting ±100 UIp-p
Line wander generation
Wander auto measurement
Automatically evaluates the wander of the sine wave by the wander sweep measurement Off: Able to set non-modulated status
TDEV mask: Reference wander The 37 types of TDEV masks that are regulated by ITU-T, ETSI, ANSI, and Bellcore standards are available as default. generation (Option 03) It is possible to add the wander modulation on the user specified TDEV mask.
Transient: It is possible to change the A(1 – e
–63.7t
) phase by the timing of the start.
Signal off: It is possible to disconnect the standard signal.
Conform to ITU-T O.172
Reference input: 2.048M (HDB3, Clock), 1.544M (AMI/B8ZS, Clock), 64k + 8 kHz, 5 MHz, 10 MHz
Sampling frequency: 40 Hz, 1 Hz, 0.1 Hz, 5 mHz (select by MX150001B)
Measurement range
P-P: 0.0 to 2E10 ns, +P/–P: 0.0 to 1E10 ns, TIE: 0.0 to ±1E10 ns
Accuracy: Conform to ITU-T O.172 Wander measurement Measurement time: 10 to 1 x 10
8
s (max. 120,000 s; MP1570A only)
(Option 02) Wander application (requires MX150001B Wander Application Software)
TIE: Max. 1 x 10
8
s, MTIE: Max. 1 x 108s, TDEV: Max. 1 x 106s Frequency offset: Measurement conforms to ANSI TI.105.09 Frequency drift rate: Measurement conforms to ANSI TI.105.09 MRTIE: The evaluation separated from the wander by a frequency offset Wander tolerance (TDEV) measurement: Evaluation by the various TDEV mask generations Wander transfer (TDEV) measurement: Calibration method by simulation,outputting results by the one measurement
Conforms to ITU-T O.172 Frequency: 2488.32 MHz Modulation frequency: 0.1 Hz to 20 MHz Amplitude: 0 to 808.0 UIp-p Resolution: 0.001 UIp-p (2 UI range), 0.01 UIp-p (20 UI range), 0.4 UIp-p (800 UI range)
Jitter generation
Accuracy
2 UI range: (±Q% of setting) ±0.02 UIp-p, 20 UI range: (±Q% of setting) ±0.3 UIp-p, 800 UI range: (±Q% of setting) ±12.5 UIp-p
Frequency offset
Range: ±100 ppm/0.1 ppm steps (jitter on/off) Accuracy: ±0.1 ppm (after power-on, calibrate after 60 min warm-up, 23˚±5 ˚C)
Auxiliary interface External clock input, Jitter reference output
Error Q Frequency range
±8% 10 µHz to 0.125 Hz ±12% 0.125 Hz to 1 Hz ±15% 1 to 10 Hz
MU150011A 2.5G Jitter Unit
F1F1' F2 F2' F3 F4 F5
0.2
0.5
2.02
20.2
808
[UIp-p]
800 Ul range
20 Ul range
20 Ul range
–20 dB/dec
–20 dB/dec
–20 dB/dec
Modulation frequency (Hz)
Jitter measurement
Bit rate F1 F1' F2∗F2'∗F3∗F4∗F5
(Mbit/s) (Hz) (Hz) (kHz) (kHz) (MHz) (MHz) (MHz)
2488.32 0.1 60 2.5 30 1.2 2 20 Typical value
Bit rate (Mbit/s)
Error Q Frequency range
±12% 0.1 Hz to 5 kHz
±8%5 to 500 kHz
2488.32 ±12% 0.5 to 2 MHz
±15% 2 to 20 MHz
27
Conforms to ITU-T O.172 Frequency: 2488.32 MHz ±100 ppm Modulation frequency: 10 Hz to 20 MHz Amplitude: 0.0 to 32 UI Resolution: 0.001 UIp-p/0.001 UIrms (2 UI range), 0.01 UIp-p/0.01 UIrms (32 UI range)
Conforms to ITU-T O.172 LP, HP0 + LP, HP1 + LP, HP2 + LP, HP + LP
Accuracy (UIp-p, UI+p, UI–p)
2 UI range: Measurement value ±R% ±W UIp-p, 32 UI range: Measurement value ±R% ±W UIp-p [MU150008A/150009A/150010A are simultaneously installed, conform to ITU-T O.172]
Fixed error [W]
Jitter measurement Input level: –12 to –10 dBm (adds to 0.01 UIp-p/dB at <–12 dBm)
Accuracy (UIrms)
2 UI range: ±R% ±Y UIrms, 32 UI range: ±R% ±Y UIrms
Fixed error [Y]
Input level: –12 to –10 dBm (adds to 0.002 UIrms/dB at <–12 dBm)
Frequency error [R]
Hit measurement Count, Seconds, % free seconds Frequency measurement
Resolution: 0.1 ppm, Display: Hz or ppm (after power-on, calibrates after 60 min warm-up, 23˚ ±5˚C)
Auxiliary interface Reference clock input
Jitter tolerance measurement: Evaluates jitter tolerance point automatically Jitter sweep measurement: Conforms to high-speed jitter tolerance evaluation for mass production, etc.
Auto jitter measurement
Jitter transfer measurement: High dynamic range measurement by selective level method Frequency sweep measurement: Measures the jitter tolerance automatically while changing the offset
F4F3'F2' F2''F0 F0'
0.2
(
0.071
)
2
(
0.707
)
32
(
11.31
)
32 Ul range
2 Ul range
–20 dB/dec
[UIp-p]
(Hz)
Modulation frequency
Jitter modulation
Bit rate F0 F0' F2' F2'' F3' F4
(Mbit/s) (Hz) (Hz) (kHz) (kHz) (MHz) (MHz)
2488.32
2 UI 100 100 1 20
32 UI 10 6.25 1 20
At PRBS 2
23
– 1
Bit rate
SONET/SDH signal
(Mbit/s)
HP1 + LP HP2 + LP
2 UI 32 UI 2 UI 32 UI
Container
2488.32 0.100 2.2 0.050 1.40 VC4-16c
At PRBS 2
23
– 1
Bit rate
SONET/SDH signal Clock signal
(Mbit/s)
HP + LP
Container
HP + LP
2 UI 32 UI 2 UI 32 UI
2488.32 0.012 0.08
VC4-16c
0.010 0.16
Bit rate
Clock signal
(Mbit/s)
HP1 + LP HP2 + LP
2 UI 32 UI 2 UI 32 UI
2488.32 0.050 0.60 0.030 0.50
Frequency error Frequency range
±7%5 to 300 kHz
±8% 300 kHz to 1 MHz ±10% 1 to 3 MHz ±15% 3 to 10 MHz ±20% 10 to 20 MHz
Bit rate HP0 HP1 HP2 HP LP
(Mbit/s) (Hz) (Hz) (Hz) (Hz) (Hz)
2488.32 10 5k 1M 12k 20M
28
Modulation frequency: 10 µHz to 0.2 Hz (sine wave) Amplitude: 0 to 57,600 UIp-p (30 UIp-p steps)
Line wander generation
Accuracy: ±Q% ±160 UIp-p
Auto wander measurement
Wander sweep measurement Reference wander generation is valid when MU150005A/150006A/150007A Option 03 is mounted.
Off: Able to set non-modulated status
Reference wander
TDEV mask:
generation
The 37 types of TDEV masks that are regulated by ITU-T, ETSI, ANSI, and Bellcore standards are available as default. It is possible to add the wander modulation to the user specified TDEV mask. Transient: It is possible to change the A(1 – e
–63.7t
) phase by the timing of the start.
Signal off: It is possible to disconnect the standard signal.
Wander measurement is valid when MU150005A/150006A/150007A Option 02 is mounted. Conforms to ITU-T O.172 Reference input: 2.048M (HDB3, clock), 1.544M (AMI/B8ZS, clock), 64k + 8 kHz, 5 MHz, 10 MHz Sampling frequency: 320 Hz, 40 Hz, 1 Hz, 0.1 Hz, 5 mHz (select from MX150001B) Measurement range
P-P: 0.0 to 2E10 ns, +P/–P: 0.0 to 1E10 ns, TIE: 0.0 to ±1E10 ns Accuracy: Conform to ITU-T O.172 Measurement time: 10 to 1 x 10
8
s (Max. 120,000 s: MP1570A only)
Wander application (requires MX150001B Wander Application Software)
Wander measurement
TIE: Max. 1 x 10
8
s
MTIE: Max. 1 x 10
8
s
TDEV: Max. 1 x 10
6
s Frequency offset: Measurement with conform to ANSI TI.105.09 Frequency drift rate: Measurement with conform to ANSI TI.105.09 MRTIE: Evaluation separated from the wander by the frequency variation Wander tolerance (TDEV) measurement: Evaluation by the various TDEV mask generations Wander transfer (TDEV) measurement: Calibration method by simulation, outputting results by the one measurement
Frequency error Frequency range
±8% 10 µHz to 0.1 Hz
±12% 0.1 to 0.2 Hz
F5F4F3F2F1F0
A2
A1
A0
[UIp-p]
Wander modulation
Modulation frequency (Hz)
Bit rate
Amplitude (UIp-p) Frequency (Hz)
(Mbit/s)
A0 A1 A2 f0 f1 f2 f3 f4 f5
2488.32 57600 6480 810 10µ 180µ 1.6m 16m 0.13 0.2
29
MP0123A ATM Unit
Bit rate 1.544, 2.048, 34.368, 44.736, 139.264, 51.84, 155.52, 622.08 Mbit/s
Mapping
Traffic pattern CBR, burst, sawtooth, CBR/PCR with CDV, Poisson
Cell: Single cell PRBS 9, cross cell PRBS 9/15/23, 16-bit word pattern, edit pattern, time stamp O.191: Edit pattern AAL1: Single cell PRBS 9, cross cell PRBS 9/15/23, 16-bit word pattern, edit pattern, time stamp
Test patterns
AAL2 (CPS-PDU): Time stamp AAL2 (CPS-PACKET): Single cell PRBS 7, 8-bit word pattern, edit pattern AAL3/4 (SAR-PDU): Time stamp AAL3/4 (CPCS-PDU): Single cell PRBS 9, cross cell PRBS 9/15/23, 16-bit word pattern, edit pattern AAL5: Single cell PRBS 9, cross cell PRBS 9/15/23, 16-bit word pattern, edit pattern
Cell: HEC, programmable pattern O.191: Lost cell, misinserted cell, errored cell, SECB AAL1: Lost cell, SNP, PRBS, word
Error addition
AAL2 (CPS-PDU): P, SN, OSF AAL2 (CPS-PACKET): HEC, PRBS, word AAL3/4 (SAR-PDU): SN, CRC10, segment type, LI, abort AAL3/4 (CPCS-PDU): CPI, B/E tag mismatch, BA size, AL, length, PRBS, word
AAL5: Frame size, length, CRC32, abort, PRBS, word Alarm addition LCD, VP/VC AIS, VP/VC RDI, VP/VC CC, VP/VC loopback cell PM cell Error insertion: Lost cell, misinserted cell, BIPV, SECB Cell editing O.191, AAL1, AAL2, AAL3/4, AAL5, AIS, RDI, CC, loopback, FM, BR, background (10 ch) Memorized cell Possible to send after editing receiver's capture data
Mode: Single, repeat, manual
Error
Cell: Cell count, correctable HEC, uncorrectable HEC, non-conforming cell O.191: Errored cell, lost cell, misinserted cell, SECB AAL1: SAR-PDU count, lost cell, SNP, uncorrectable SNP, PRBS, word AAL2: CPS-PDU count, P, OSF, SN, CPS packet count, CID count (CPS packet with selected CID value), HEC, PRBS, word AAL3/4
*
:SAR-PDU count, CRC10, MID count (SAR-PDU with selected MID value), SN, ST (segment type), LI, abort, discarded
PDU (one of SN error, Ll error, abort, COM with ST error, or EOM with ST error), CPCS-PDU count, CPI, B/E tag
Measurement mismatch, BA size, AL, length, undeliverded PDU (one of CPI error, B/E tag mismatch, BAsize error, AL error, or
length error), PRBS, word
*
CRC10 is calculated for all SAR-PDU. The others are calculated for SAR-PDU with specified MID.
AAL5: CPCS-PDU count, frame size, length, CRC32, abort, discarded PDU (one of frame size error, length error, CRC32 error, or
abort), PRBS, word FM: Lost cell, misinserted cell, BIPV, SECB BR: Lost cell, misinserted cell, BIPV, SECB
Alarm: LCD, VP/VC segment AIS, VP/VC end-to-end AIS, VP/VC segment RDI, VP/VC end-to-end RDI, VP/VC segment LOC, VP/VC
end-to-end LOC LED LCD, VP-AIS, VP-RDI, VP-LOC, VC-AIS, VC-RDI, VC-LOC, errors Monitor Live monitor (1023 channel monitor), traffic monitor, cell monitor Delay measurement 1-point CDV, 2-point CDV Capture 1 to 2016 cells
SDH
PDH
AAL1
ATM/AAL
AAL2
AAL3/4
AAL5
ATM
STM-1c
STM-0
139M (G.832)
34M (G.832)
2M (G.704)
45M (G.704)
1.5M (G.704)
STM-4c (optical) STM-1c (optical)
30
Bit rate 1.544, 2.048, 34.368, 44.736, 139.264 Mbit/s
1.544 Mbit/s: ANSI T1.102, 0/655 ft
Level/waveform 44.736 Mbit/s: ANSI T1.102, 0/450/900 ft (0 ft: Drop only)
2.048/34.368/139 Mbit/s: ITU-T G.703 Bantam (100 , balanced): 1.544 Mbit/s (AMI/B8ZS)
Connector 3-pin Siemens (120 , balanced): 2.048 Mbit/s (HDB3)
BNC (75 , unbalanced): 2.048 Mbit/s, 34.368 Mbit/s (HDB3), 139.264 Mbit/s (CMI)
Mapping See Fig. 2
MP0131A Add/Drop Unit
139M (Async.)
34M (Async.)
45M (Async.)
2M (Async.)
1.5M (Async.)
x 3
x 3
x 3
x 7
x 7
STM-16
STM-64
STM-4
AUG
STM-1
AU-4
VC-4
TUG-3 TU-3 VC-3
TU-11 VC-11
TUG-2
VC-3
AU-3
STM-0
x 4
x 16
x 64
x 4
VC-12
TU-12
Fig. 2 Add/Drop mapping structure
Bit rate: 155.52, 622.08 Mbit/s (NRZ) Wavelength: 1550 nm
Transmit Output level: –5 dBm ±2 dB
Optical safety: IEC825-1 Class 1, 21CFR1040.10 Class Ι Connector: FC-PC (SM-F)
Bit rate: 155.52, 622.08 Mbit/s (NRZ) Sensitivity
156M: –33 to –8 dBm (test pattern: PRBS 2
23
– 1, BER 10
–10
, +10˚ to +40˚C)
622M: –28 to –8 dBm (test pattern: PRBS 2
23
– 1, BER 10
–10
, +10˚ to +40˚C)
Receive Connector: FC-PC (SM-F)
Power measurement
Measurement range: –30 to 0 dBm (peak power) Accuracy: ±1 dB (–20 dBm) Linearity: ±1 dB (–30 to 0 dBm)
Bit rate: 155.52, 622.08 Mbit/s (NRZ) Wavelength: 1310 nm
Transmit Output level: –11.5 dBm ±3.5 dB
Optical safety: IEC 825-1 Class 1, 21CFR1040.10 Class Ι Connector: FC-PC (SM-F)
Bit rate: 155.52, 622.08 Mbit/s (NRZ) Sensitivity
156M: –33 to –8 dBm (test pattern: PRBS 2
23
– 1, BER 10
–10
, +10˚ to +40˚C)
622M: –28 to –8 dBm (test pattern: PRBS 2
23
– 1, BER 10
–10
, +10˚ to +40˚C)
Receive Connector: FC-PC (SM-F)
Power measurement
Measurement range: –30 to 0 dBm (peak power) Accuracy: ±1 dB (–20 dBm) Linearity: ±1 dB (–30 to 0 dBm)
MP0111AOptical 156M/622M (1.31) Unit
MP0112A Optical 156M/622M (1.55) Unit
31
MP0113A Optical 156M/622M (1.31/1.55) Unit
Bit rate: 155.52, 622.08 Mbit/s (NRZ) Wavelength: 1310/1550 nm
Transmit
Output level
1.31 µm: –11.5 dBm ±3.5 dB, 1.55 µm: –5 dBm ±2 dB Optical safety: IEC825-1 Class 1, 21CFR1040.10 Class Ι Connector: FC-PC (SM-F)
Bit rate: 155.52, 622.08 Mbit/s (NRZ) Sensitivity
156M: –33 to –8 dBm (test pattern: PRBS 2
23
– 1, BER 10
–10
, +10˚ to +40˚C)
622M: –28 to –8 dBm (test pattern: PRBS 2
23
– 1, BER 10
–10
, +10˚ to +40˚C)
Receive Connector: FC-PC (SM-F)
Power measurement
Measurement range: –30 to 0 dBm (peak power) Accuracy: ±1 dB (–20 dBm) Linearity: ±1 dB (–30 to 0 dBm)
Bit rate: 51.84 Mbit/s (NRZ) Wavelength: 1310 nm
Transmit Output level: –11.5 dBm ±3.5 dB
Optical safety: IEC 825-1 Class 1, 21CFR1040.10 Class Ι Connector: FC-PC (SM-F)
Bit rate: 51.84 Mbit/s (NRZ) Sensitivity
52M: –33 to –8 dBm (test pattern: PRBS 2
23
– 1, BER 10
–10
, +10˚ to +40˚C)
Connector: FC-PC (SM-F)
Receive Power measurement
Measurement range: –30 to 0 dBm (peak power) Accuracy: ±1 dB (–20 dBm) Linearity: ±1 dB (–30 to 0 dBm)
Monitor input
Level: 0.1 to 1.0 Vp-p (AC), Connector: SMA (50 Ω)
MP0122B 1.5/45/52/52 (1.31) Unit
Optical interface
TransmitBit rate: 155.52 Mbit/s, Level: 1 ±0.1 V, Connector: BNC (75 Ω)
Bit rate: 155.52 Mbit/s
Receive Level: 1 ±0.1 V (0 to 12 dB, with f auto correction and monitor function)
Connector: BNC (75 Ω)
Bit rate: 155.52, 622.08 Mbit/s
Transmit Level: ECL
Connector (Data, Clock): SMA (50 Ω) Bit rate: 155.52, 622.08 Mbit/s
Receive Level: ECL (–2 V)
Connector (Data, Clock): SMA (50 Ω)
MP0105A CMI Unit
MP0108A NRZ Unit
32
Bit rate 2488.32 Mbit/s (NRZ)
Wavelength: 1310 nm (MU150008A), 1550 nm (MU150009A), 1310/1550 nm (MU150010A)
Optical Output level: –4 dBm ±3 dB output Optical safety: IEC825-1 Class 3A, 21CFR1040.10 Class ΙΙΙb
Connector: FC-PC (SM-F) Sensitivity
Narrow: –28 to –9 dBm(BER 10
–10
, +10˚ to +30˚C), –27 to –9 dBm (BER 10
–10
, 0˚ to +30˚C)
Wide: –20 to –9 dBm (BER 10
–10
, +10˚ to +40˚C) Optical Connector: FC-PC (SM-F) input Power measurement
Range: –30 to –9 dBm (peak power) Accuracy: ±2 dB (–20 dBm) Linearity: ±2 dB (–30 to –9 dBm)
Transmit (NRZ)
Level: ECL (–2 V), Connector (Data, Clock): SMA (50 Ω) Electrical Receive (NRZ) I/O Level: ECL (–2 V), Connector (Data, Clock): SMA (50 Ω)
Monitor input
Level: 0.1 to 1.0 Vp-p (AC), Connector (Data): SMA (50 Ω) Auxiliary
External clock input, Receive clock output, Sync. output
interface
MU150008A/150009A/150010A 2.5G Unit
Bit rate 9953.28, 2488.32 Mbit/s (NRZ)
Transmit (NRZ)
Level
Data H: 0 to –0.2 V, Data L: –0.85 to –1.4 V Clock H: 0 to –0.2 V, Clock L: –0.85 to –1.3 V
Electrical
Connector (Data, Clock): SMA (50 Ω)
I/O
Receive (NRZ)
Level
Data: 0.65 to 1.4 Vp-p, Clock: 0.65 to 1.3 Vp-p
Connector (Data, Clock): SMA (50 Ω) Auxiliary
External clock input, Internal clock output, Receive clock output,156M sync. output
interface
MU150000A 2.5G/10G Unit
Bit rate 9953.28, 2488.32 Mbit/s (Option)
Wavelength:
10G: 1550 nm band Optical 2.5G: 1310 nm band (Option 01),1550 nm band (Option 02),1310/1550 nm band (Option 03) output Output level: –4 dBm ±3 dB
Optical safety: IEC825-1 Class 3A, 21CFR1040.10 Class ΙΙΙb Connector: FC-PC (SMF)
Data input
Electrical
H: 0 to –0.2 V, L: –0.85 to –1.4 V
Clock input
H: 0 to –0.2 V, L: –0.85 to –1.3 V
Connector: SMA 50
MU150001A/B Optical 10G Tx (1.55) Unit
Bit rate 9953.28, 2488.32 Mbit/s (Option 01)
Sensitivity
10G: –13 to –3 dBm (BER 10
–12
, NRZ, mark ratio: 1/2, PRBS: 2
31
–1)
2.5G: –29 to – 10 dBm (BER 10
–11
, NRZ, mark ratio: 1/2, PRBS: 2
23
–1) (Option 01)
Connector: FC-PC (SMF) Optical Power measurement input Range:–16 to 0 dBm (10G, average power), –30 to –10 dBm (2.5G, average power)
Accuracy: ±2 dB (10G, –10 dBm), ±2 dB (2.5G, – 20 dBm) Linearity: ±2 dB (10G, –16 to 0 dBm), ±2 dB (2.5G, –30 to –10 dBm)
Data output: 0.65 to 1.4 Vp-p
Electrical
Clock output: 0.65 to 1.3 Vp-p
output
Connector: SMA 50
MU150002A Optical 10G Rx (Narrow) Unit
*
These units are not supported path penalty specification.
33
Typical Configuration
2.5G for Europe
1
2
3
5 6
4
2.5G for North America and Japan
7
8
9
12
10 11
1 2 3
4 5
MP1570A main frame MP0113AOptical 156M/622M (1.31/1.55) Unit MP0121A 2/8/34/139/156M Unit MU150010A 2.5G (1.31/1.55) Unit MU150011A2.5G Jitter Unit MU150007A 2/8/34/139M, 1.5/45/52M, 156/622M Jitter Unit
6
ATM
18
13
16
15
17
14
7 8 9
10
11
MP1570A main frame (Japan: with Option 09) MP0113AOptical 156M/622M (1.31/1.55) Unit MP0122A 1.5/45/52M Unit MU150010A 2.5G (1.31/1.55) Unit MU150011A2.5G Jitter Unit MU150007A 2/8/34/139M, 1.5/45/52M, 156/622M Jitter Unit
12
13 14 15
16 17
MP1570A main frame MP0113AOptical 156M/622M (1.31/1.55) Unit MP0121A 2/8/34/139/156M Unit MP0122A 1.5/45/52M Unit MP0123AATM Unit MU150007A 2/8/34/139M, 1.5/45/52M, 156/622M Jitter Unit
18
34
10G for Europe
23 24
19
21 22
20
10 G for North America and Japan
19 20 21
22
23
MP1570A main frame MP0113AOptical 156M/622M (1.31/1.55) Unit MP0121A 2/8/34/139/156M Unit MU150002A Optical 10G Rx (Narrow) Unit MU150001A Optical 10G Tx (1.55) Unit MU150000A 2.5G/10G Unit
24
25 26 27 28 29
MP1570A main frame (Japan: with Option 09) MP0113AOptical 156M/622M (1.31/1.55) Unit MP0122A 1.5/45/52M Unit MU150002A Optical 10G Rx (Narrow) Unit MU150001A Optical 10G Tx (1.55) Unit MU150000A 2.5G/10G Unit
30
Note: The same model name units can not be used simultaneously with inserted them in to the plural slots. Only one unit is usable at a time.
*
1: MP0122A/B can not insert in to Slot 1 when MP0123A is inserted in to Slot 3.
29 30
25
27 28
26
Unit Slot 1 Slot 2 Slot 3 Slot 4/5 Front
MP0121A 2/8/34/139/156M Unit
MP0122A 1.5/45/52M Unit
*
MP0122B 1.5/45/52/52M (1.31) Unit
*
MP0123AATM Unit
MU150005A 2/8/34/139M,156/622M Jitter Unit
MU150006A
1.5/45/52M, 156/622M Jitter Unit
MU150007A 2/8/34/139M,1.5/45/52M, 156M/622M
Jitter Unit MP0111A Optical 156/622M (1.31) Unit MP0112AOptical 156/622M (1.55) Unit MP0113AOptical 156/622M (1.31/1.55) Unit MU150008A 2.5G (1.31) Unit
MU150009A 2.5G (1.55) Unit
MU150010A 2.5G (1.31/1.55) Unit
MU150011A
2.5G Jitter Unit
MP0131AAdd/Drop Unit
√√
MU150000A 2.5G/10G Unit
MU150001A/B Optical 10G Tx (1.55) Unit
MU150002A Optical 10G Rx (Narrow) Unit
MP0105A CMI Unit MP0108A NRZ Unit
Slot 3Front Slot 4/5
Slot 1 Slot 2
35
Please specify the model/order number and quantity when ordering.
Model/Order No. Name Remarks
MP1570A
*
1
SONET/SDH/PDH/ATM Analyzer
AC power cord: 1 pc Z0169 Printer paper (5 rolls/pack): 1 pack F0079 Fuse, 10 A: 2 pcs B0329G Front cover: 1 pc Z0486 Side cover: 1 pc J0907Q Remote interlock cord: 1 pc For MU150001A/B, MU150008A, MU150009A, MU150010A,
MU150031A/C, MU150061A/B
J0908 Remote interlock terminator: 1 pc For MU150001A/B, MU150008A, MU150009A, MU150010A,
MU150031A/C, MU150061A/B
E0008A Optical output control key: 2 pc For MU150001A/B, MU150008A, MU150009A, MU150010A,
MU150031A/C, MU150061A/B J0747A Fixed optical attenuator (5 dB): 1 pc For MU150017A/B J0747B Fixed optical attenuator (10 dB): 1 pc For MU150002A J0747C Fixed optical attenuator (15 dB): 1 pc For MU150008A, MU150009A, MU150010A J0900A Coaxial cable (AA-165-200), 20 cm: 2 pcs For MU150011A J0635A Optical fiber cable (FC • PC-FC • PC), 1 m: 1 pc For MU150002A, MU150008A, MU150009A, MU150010A,
MU150017A/B, MP0111A, MP0112A, MP0113A MX150001B Wander (MTIE, TDEV) Measurement Application Software: 1 pc Supplied with MU150005A-02, MU150006A-02, MU150007A-02 W1719AE MP1570A operation manual (Vol. 1 Basic operation for SDH): 1 copy W1720AE
MP1570A operation manual (Vol. 1 Basic operation for SONET):
1 copy W1721AE MP1570A operation manual (Vol. 2 Remote control): 1 copy W1722AE MP1570A operation manual (Vol. 3 ATM measurement): 1 copy W1723AE MP1570A operation manual (Vol. 4 2.5G/10G measurement): 1 copy W1724AE MP1570A operation manual (Vol. 5 Add/Drop function): 1 copy W1725AE
MP1570A operation manual (Vol. 6 Jitter/wander measurement):
1 copy For MU150005A, MU150006A, MU150007A W1726AE
MP1570A operation manual (Vol. 7 2.5G jitter/wander measurement):
1 copy For MU150011A W1763AE
Wander (MTIE, TDEV) Measurement Application Software Manual:
1 copy Supplied with MX150001B J1002A Semi-rigid cable: 2 pcs For MU150001A/B J1002B Semi-rigid cable: 2 pcs For MU150002A J1002C Semi-rigid cable: 3 pcs For MU150000A
MP0121A 2/8/34/139/156M Unit MP0122A 1.5/45/52M Unit MP0122B
*
2
1.5/45/52/52M (1.31) Unit MP0123A ATM Unit MU150005A 2/8/34/139M, 156/622M Jitter Unit Only jitter generation/measurement, requires MP0121A MU150006A 1.5/45/52M, 156/622M Jitter Unit Only jitter generation/measurement, requires MP0122A/B MU150007A 2/8/34/139M, 1.5/45/52M, 156/622M Jitter Unit Only jitter generation/measurement, requires MP0121A or
MP0122A/B
MU150008A
*
2
2.5G (1.31) Unit With optical power meter MU150009A
*
2
2.5G (1.55) Unit With optical power meter MU150010A
*
2
2.5G (1.31/1.55) Unit With optical power meter MU150011A 2.5G Jitter Unit Only jitter generation/measurement, requires MU150008A,
MU150009A, or MU150010A MP0131A Add/Drop Unit MU150000A 2.5G/10G Unit MU150001A
*
2
Optical 10G Tx (1.55) Unit 2 km transmission
MU150001B
*
2
Optical 10G Tx (1.55) Unit 40 km transmission
MU150002A
*
2
Optical 10G Rx (Narrow) Unit With optical power meter
MP0111A
*
2
Optical 156M/622M (1.31) Unit With optical power meter
MP0112A
*
2
Optical 156M/622M (1.55) Unit With optical power meter
MP0113A
*
2
Optical 156M/622M (1.33/1.55) Unit With optical power meter, 1.31/1.55 switchable MU150017A Optical 10G Rx (Wide) Unit MU150017B Optical 2.5G/10G Rx (Wide) Unit MU150031A Optical 10G Tx (1.55) High Power Unit MU150031C Optical 2.5G/10G Tx (1.55) High Power Unit MU150061A Optical 10G Tx (1.31) Unit MU150061B Optical 2.5G/10G Tx (1.31) Unit MP0105A CMI Unit MP0108A NRZ Unit
MP1570A-01
*
3
RS-232C MP1570A-02
*
3
GPIB MP1570A-03
*
3
Ethernet MP1570A-04
*
3
VGA output MP1570A-06 MUX/DEMUX (2/8/34/139 Mbit/s) For MP0121A MP1570A-07 MUX/DEMUX (1.5/45 Mbit/s) For MP0122A/B MP1570A-08 45M-2M MUX/DEMUX Requires MP0121Aand MP0122A/B MP1570A-09 Japan mapping Requires MP0122A or MP0122B MP1570A-10
*
1
SDH MP1570A-11
*
1
SONET MP1570A-13 Frame memory capture (156M/622M) 64 frame MP1570A-14 IP-over-SONET/SDH Requires option of frame memory/capture MP1570A-15 IP-over-ATM Requires MP0123A MP1570A-22 K1/K2 overwrite through
Options
Plug-in units
Standard accessories
Main frame
Ordering Information
36
Model/Order No. Name Remarks
MU150005A-02 Wander measurement MU150006A-02 Wander measurement MU150007A-02 Wander measurement MU150005A-03 Wander reference output MU150006A-03 Wander reference output MU150007A-03 Wander reference output MU150008A-01 Frame memory capture (2.5G) 64 frame MU150009A-01 Frame memory capture (2.5G) 64 frame MU150010A-01 Frame memory capture (2.5G) 64 frame MU150000A-01 Frame memory capture (2.5G/10G) 26 frame MU150001A/B-01 2.5G (1.31) MU150001A/B-02 2.5G (1.55) MU150001A/B-03 2.5G (1.31/1.55) MU150002A-01 2.5G MU150002A-04 Available for 10G (1.31) MP0111A/0112A-37
FC connector Replaceable, 2 sets
MP0111A/0112A-38
ST connector Replaceable, 2 sets
MP0111A/0112A-39
DIN connector Replaceable, 2 sets
MP0111A/0112A-40
SC connector Replaceable, 2 sets
MP0111A/0112A-43
HMS-10/A connector Replaceable, 2 sets
MP0113A-37 FC connector Replaceable, 3 sets MP0113A-38 ST connector Replaceable, 3 sets MP0113A-39 DIN connector Replaceable, 3 sets MP0113A-40 SC connector Replaceable, 3 sets MP0113A-43 HMS-10/A connector Replaceable, 3 sets MP0122B-37 FC connector Replaceable, 2 sets MP0122B-38 ST connector Replaceable, 2 sets MP0122B-39 DIN connector Replaceable, 2 sets MP0122B-40 SC connector Replaceable, 2 sets MP0122B-43 HMS-10/A connector Replaceable, 2 sets MU150008A-37 FC connector Replaceable, 2 sets MU150008A-38 ST connector Replaceable, 2 sets MU150008A-39 DIN connector Replaceable, 2 sets MU150008A-40 SC connector Replaceable, 2 sets MU150008A-43 HMS-10/A connector Replaceable, 2 sets MU150009A-37 FC connector Replaceable, 2 sets MU150009A-38 ST connector Replaceable, 2 sets MU150009A-39 DIN connector Replaceable, 2 sets MU150009A-40 SC connector Replaceable, 2 sets MU150009A-43 HMS-10/A connector Replaceable, 2 sets MU150010A-37 FC connector Replaceable, 3 sets MU150010A-38 ST connector Replaceable, 3 sets MU150010A-39 DIN connector Replaceable, 3 sets MU150010A-40 SC connector Replaceable, 3 sets MU150010A-43 HMS-10/A connector Replaceable, 3 sets MU150001A/B-37 FC connector Replaceable, 1 set MU150001A/B-38 ST connector Replaceable, 1 set MU150001A/B-39 DIN connector Replaceable, 1 set MU150001A/B-40 SC connector Replaceable, 1 set MU150001A/B-43 HMS-10/Aconnector Replaceable, 1 set MU150002A-37 FC connector Replaceable, 1 set
*
4
MU150002A-38 ST connector Replaceable, 1 set
*
4
MU150002A-39 DIN connector Replaceable, 1 set
*
4
MU150002A-40 SC connector Replaceable, 1 set
*
4
MU150002A-43 HMS-10/A connector Replaceable, 1 set
*
4
MU150017A/B-37 FC connector Replaceable, 1 set MU150017A/B-38 ST connector Replaceable, 1 set MU150017A/B-39 DIN connector Replaceable, 1 set MU150017A/B-40 SC connector Replaceable, 1 set MU150017A/B-43 HMS-10/A connector Replaceable, 1 set MU150031A/C-37 FC connector Replaceable, 1 set MU150031A/C-38 ST connector Replaceable, 1 set MU150031A/C-39 DIN connector Replaceable, 1 set MU150031A/C-40 SC connector Replaceable, 1 set MU150031A/C-43 HMS-10/A connector Replaceable, 1 set MU150061A/B-37 FC connector Replaceable, 1 set MU150061A/B-38 ST connector Replaceable, 1 set MU150061A/B-39 DIN connector Replaceable, 1 set MU150061A/B-40 SC connector Replaceable, 1 set MU150061A/B-43 HMS-10/A connector Replaceable, 1 set
MP1570A-90 Extended three year warranty service MP0121A-90 Extended three year warranty service MP0122A-90 Extended three year warranty service MP0122B-90 Extended three year warranty service MP0123A-90 Extended three year warranty service MU150005A-90 Extended three year warranty service MU150006A-90 Extended three year warranty service MU150007A-90 Extended three year warranty service MU150008A-90 Extended three year warranty service MU150009A-90 Extended three year warranty service MU150010A-90 Extended three year warranty service
Maintenance service
*
5
37
*
1: Must specify SDH (Option 10) or SONET (Option 11) when ordering depends on your system. The option price is included in the MP1570A. These two
options can be installed simultaneously. But in this case, one option price is charged.
*
2: Specify the connector to be supplied as the standard connector when ordering the above options.
If the connector is not specified the FC connector (MP0111A/0112A/0113A/0122B-37, MU150008A/150009A/150010A/150001A/150001B/150002A-37) is supplied as standard.
*
3: The video output, RS-232C, GPIB and Ethernet options cannot all be used simultaneously. Only the video output + RS-232C, or video output + GPIB,
or RS-232C + GPIB board, or Ethernet board combinations support simultaneous use, so change the board combinations according to the purpose.
*
4: With Option 01, 2 sets
*
5: Please ask your local Anritsu Field Office or Sales. Representative for price and availability.
The units for MP1552A/B and MP1555A/B can be used with MP1570A.
Model/Order No. Name Remarks
MU150011A-90 Extended three year warranty service MU150000A-90 Extended three year warranty service MU150001A-90 Extended three year warranty service MU150001B-90 Extended three year warranty service MU150002A-90 Extended three year warranty service MP0111A-90 Extended three year warranty service MP0112A-90 Extended three year warranty service MP0113A-90 Extended three year warranty service MP0105A-90 Extended three year warranty service MP0108A-90 Extended three year warranty service MU150017A/B-90 Extended three year warranty service MU150031A/C-90 Extended three year warranty service MU150061A/B-90 Extended three year warranty service
MP1777A 10 GHz Jitter Analyzer MP9677B E/O, O/E Converter MU967701A Clock Recovery Unit 9.95328 Gbit/s MP1580A Portable 2.5G/10G Analyzer MU150018A 2.5G/10G Jitter Unit For MP1580A
J0796A ST connector Replaceable, with protective caps, 1 set J0796B DIN connector Replaceable, with protective caps, 1 set J0796C SC connector Replaceable, with protective caps, 1 set J0796D HMS-10/Aconnector Replaceable, with protective caps, 1 set J0796E FC connector Replaceable, with protective caps, 1 set J0162A Balanced cable, 1 m Siemens 3p-Siemens 3p J0162B Balanced cable, 2 m Siemens 3p-Siemens 3p J0845A Balanced cable, 6 ft Bantam 3P/Bantam 3P J0775D Coaxial cable (BNC-P620
3C-2WS •BNC-P620, 75 ), 2 m
J0776D Coaxial cable (BNC-P-3W
3D-2W •BNC-P-3W, 50 ), 2 m
J0898A Conversion cable (M-1PS
Bantam 3P), 1 m
J0898B Conversion cable (M-1PS
Bantam 3P), 2 m J0635A Optical fiber cable, 1 m SM, FC-SPC connector both ends J0635B Optical fiber cable, 2 m SM, FC-SPC connector both ends J0635C Optical fiber cable, 3 m SM, FC-SPC connector both ends J0660A Optical fiber cable, 1 m SM, SC connector both-ends J0660B Optical fiber cable, 2 m SM, SC connector both-ends J0660C Optical fiber cable, 3 m SM, SC connector both-ends J0756A Optical fiber cable, 1 m SM, ST connector both-ends J0756B Optical fiber cable, 2 m SM, ST connector both-ends J0756C Optical fiber cable, 3 m SM, ST connector both-ends J0747A Fixed optical attenuator (5 dB) J0747B Fixed optical attenuator (10 dB) J0747C Fixed optical attenuator (15 dB) J0747D Fixed optical attenuator (20 dB) J1049A Fixed optical attenuator (SC, 5 dB) J1049B Fixed optical attenuator (SC, 10 dB) J1049C Fixed optical attenuator (SC, 15 dB) J1049D Fixed optical attenuator (SC, 20 dB) J1050A Fixed optical attenuator (ST, 5 dB) J1050B Fixed optical attenuator (ST, 10 dB) J1050C Fixed optical attenuator (ST, 15 dB) J1050D Fixed optical attenuator (ST, 20 dB) J0322B Coaxial cable (11SMA
SUCOFLEX104 •11SMA), 1 m J0008 GPIB cable, 2 m A0006 Head set B0453B Blank panel (for front panel) B0454C Blank panel (for Slot 1 to 3) B0454D Blank panel (for Slot 4/5) B0448 Soft case B0336C Carrying case
Optional accessories
Application equipment
Carrying case
Soft case
ANRITSU CORPORATION
5-10-27, Minamiazabu, Minato-ku, Tokyo 106-8570, Japan Phone: +81-3 - 3446 - 1111 Telex: J34372 Fax: +81-3 - 3442-0235
U.S.A. ANRITSU COMPANY North American Region Headquarters
1155 East Collins Blvd., Richardson, TX 75081, U.S.A. Toll Free: 1 - 800 - ANRITSU (267 - 4878) Phone: +1- 972-644 - 1777 Fax: +1-972 - 671-1877
Canada ANRITSU ELECTRONICS LTD.
700 Silver Seven Road, Suite 120, Kanata, ON K2V 1C3, Canada Phone: +1-613-591 - 2003 Fax: +1-613-591 - 1006
Brasil ANRITSU ELETRÔNICA LTDA.
Praia de Botafogo 440, Sala 2401 CEP 22250-040, Rio de Janeiro, RJ, Brasil Phone: +55-21-5276922 Fax: +55-21 - 537-1456
U.K. ANRITSU LTD.
200 Capability Green, Luton, Bedfordshire LU1 3LU, U.K. Phone: +44-1582-433200 Fax: +44-1582 - 731303
Germany
ANRITSU GmbH
Grafenberger Allee 54-56, 40237 Düsseldorf, Germany Phone: +49-211- 96855 - 0 Fax: +49-211- 96855 - 55
France
ANRITSU S.A.
9, Avenue du Québec Z.A. de Courtabœuf 91951 Les Ulis Cedex, France Phone: +33-1-60 - 92 - 15 - 50 Fax: +33-1-64 - 46 - 10 - 65
Italy
ANRITSU S.p.A.
Via Elio Vittorini, 129, 00144 Roma EUR, Italy Phone: +39-06-509 - 9711 Fax: +39-06 - 502-24 - 25
Sweden
ANRITSU AB
Botvid Center, Fittja Backe 1-3 145 84 Stockholm, Sweden Phone: +46-853470700 Fax: +46-853470730
Spain
ANRITSU ELECTRÓNICA, S.A.
Europa Empresarial Edificio Londres, Planta 1, Oficina 6 C/ Playa de Liencres, 2 28230 Las Rozas. Madrid, Spain Phone: +34-91-6404460 Fax: +34-91 - 6404461
Singapore
ANRITSU PTE LTD.
10, Hoe Chiang Road #07-01/02, Keppel Towers, Singapore 089315 Phone: +65-6282-2400 Fax: +65-6282-2533
Hong Kong
ANRITSU COMPANY LTD.
Suite 719, 7/F., Chinachem Golden Plaza, 77 Mody Road, Tsimshatsui East, Kowloon, Hong Kong, China Phone: +852-2301 - 4980 Fax: +852-2301 - 3545
Korea
ANRITSU CORPORATION
8F Hyun Juk Bldg. 832-41, Yeoksam-dong, Kangnam-ku, Seoul, 135-080, Korea Phone: +82-2-553 - 6603 Fax: +82-2-553 - 6604
˜
5
Australia
ANRITSU PTY LTD.
Unit 3/170 Forster Road Mt. Waverley, Victoria, 3149, Australia Phone: +61-3-9558 - 8177 Fax: +61-3-9558 - 8255
Taiwan
ANRITSU COMPANY INC.
7F, No. 316, Sec. 1, NeiHu Rd., Taipei, Taiwan Phone: +886-2-8751 - 1816 Fax: +886-2-8751 - 1817
Specifications are subject to change without notice.
Catalog No. MP1570A(SDH)- E - A - 1- (7.00) Printed in Japan 2003 - 2 W/M
030220
Loading...