AMX NI-3000, NI-2000, NI-4000 User Manual

0 (0)
instruction manual
NetLinx Central Controllers and Cards
NetLinx Integrated
Controllers
(NI-2000, NI-3000, and NI-4000)
AMX Limited Warranty and Disclaimer
AMX Corporation warrants its products to be free of defects in material and workmanship under normal use for three
(3) years from the date of purchase from AMX Corporation, with the following exceptions:
overlay components that are warranted for a period of one (1) year.
Disk drive mechanisms, pan/tilt heads, power supplies, and MX Series products are warranted for a period of one
(1) year.
AMX Lighting products are guaranteed to switch on and off any load that is properly connected to our lighting
products, as long as the AMX Lighting products are under warranty. AMX Corporation does guarantee the
control of dimmable loads that are properly connected to our lighting products. The dimming performance or
quality cannot be guaranteed due to the random combinations of dimmers, lamps and ballasts or transformers.
Unless otherwise specified, OEM and custom products are warranted for a period of one (1) year.
AMX Software is warranted for a period of ninety (90) days.
Batteries and incandescent lamps are not covered under the warranty.
This warranty extends only to products purchased directly from AMX Corporation or an Authorized AMX Dealer.
All products returned to AMX require a Return Material Authorization (RMA) number. The RMA number is
obtained from the AMX RMA Department. The RMA number must be clearly marked on the outside of each box.
The RMA is valid for a 30-day period. After the 30-day period the RMA will be cancelled. Any shipments received
not consistent with the RMA, or after the RMA is cancelled, will be refused. AMX is not responsible for products
returned without a valid RMA number.
AMX Corporation is not liable for any damages caused by its products or for the failure of its products to perform.
This includes any lost profits, lost savings, incidental damages, or consequential damages. AMX Corporation is not
liable for any claim made by a third party or by an AMX Dealer for a third party.
This limitation of liability applies whether damages are sought, or a claim is made, under this warranty or as a tort
claim (including negligence and strict product liability), a contract claim, or any other claim. This limitation of
liability cannot be waived or amended by any person. This limitation of liability will be effective even if AMX Corpo-
ration or an authorized representative of AMX Corporation has been advised of the possibility of any such damages.
This limitation of liability, however, will not apply to claims for personal injury.
Some states do not allow a limitation of how long an implied warranty last. Some states do not allow the limitation or
exclusion of incidental or consequential damages for consumer products. In such states, the limitation or exclusion of
the Limited Warranty may not apply. This Limited Warranty gives the owner specific legal rights. The owner may
also have other rights that vary from state to state. The owner is advised to consult applicable state laws for full
determination of rights.
EXCEPT AS EXPRESSLY SET FORTH IN THIS WARRANTY, AMX CORPORATION MAKES NO
OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. AMX CORPORATION
EXPRESSLY DISCLAIMS ALL WARRANTIES NOT STATED IN THIS LIMITED WARRANTY. ANY
IMPLIED WARRANTIES THAT MAY BE IMPOSED BY LAW ARE LIMITED TO THE TERMS OF THIS
LIMITED WARRANTY.
This product includes the GoAhead Web Server.
Copyright (c) 2003 GoAhead Software, Inc. All Rights Reserved.
This product includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit.
(http://www.openssl.org/)
This product includes cryptographic software written by Eric Young (eay@cryptsoft.com)
Table of Contents
i
NetLinx Integrated Controllers
Table of Contents
Introduction ...............................................................................................................1
NI-2000 Specifications ...................................................................................................... 1
NI-3000 Specifications ...................................................................................................... 5
NI-4000 Specifications .................................................................................................... 10
Quick Setup and Configuration Overview ............................................................15
Installation Procedures.................................................................................................... 15
Configuration and Communication .................................................................................. 15
Update the Controller and Control Card Firmware.......................................................... 16
Program NetLinx Security into the On-Board Master ...................................................... 16
Connections and Wiring ........................................................................................17
Setting the Configuration DIP Switch (for the Program Port) .......................................... 17
Baud rate settings .................................................................................................................. 17
Program Run Disable (PRD) mode ........................................................................................ 17
Using the Configuration DIP switch........................................................................................ 18
Modes and Front Panel LED Blink Patterns.................................................................... 18
Wiring Guidelines ............................................................................................................ 18
Preparing captive wires .......................................................................................................... 19
Wiring length guidelines ......................................................................................................... 19
Wiring a power connection ..................................................................................................... 19
Using the 4-pin mini-Phoenix connector for data and power ................................................. 20
Using the 4-pin mini-Phoenix connector for data with external power ................................... 20
Program Port Connections and Wiring............................................................................ 21
RS-232/422/485 Device Port Wiring Specifications ........................................................ 21
ICSNet RJ-45 Connections/Wiring .................................................................................. 22
ICSHub OUT port................................................................................................................... 23
Ethernet 10/100 Base-T RJ-45 Connections/Wiring ....................................................... 23
Ethernet ports used by the Integrated Controllers ................................................................. 24
Relay Connections and Wiring ........................................................................................ 24
Relay connections.................................................................................................................. 25
Input/Output (I/O) Connections and Wiring ..................................................................... 25
IR/Serial Connections and Wiring ................................................................................... 26
NetLinx Control Card Slot Connector (NI-4000 unit only) ............................................... 27
ii
NetLinx Integrated Controllers
Table of Contents
Installation and Upgrading ....................................................................................29
Installing NetLinx Control Cards (NI-4000 Only)............................................................. 29
Setting the NetLinx Control Card Addresses (NI-4000 Only).......................................... 30
Device:Port:System (D:P:S)............................................................................................ 30
Removing NetLinx Control Cards (NI-4000 Only) ........................................................... 31
Compact Flash Upgrades ............................................................................................... 31
Accessing the internal components on an Integrated Controller............................................ 31
Installation of Compact Flash upgrades................................................................................. 32
Closing and Securing the Integrated Controller ..................................................................... 33
Installing the Integrated Controller into an Equipment Rack ........................................... 34
Configuration and Firmware Update ....................................................................37
Communicating with the Master via the Program Port.................................................... 37
Setting the System Value................................................................................................ 38
Using multiple NetLinx Masters.............................................................................................. 39
Changing the Device Address on a NetLinx Device ....................................................... 40
Recommended NetLinx Device numbers............................................................................... 41
Resetting the Factory Default System and Device Values.............................................. 41
Obtaining the Master’s IP Address (using DHCP) .......................................................... 42
Assigning a Static IP to the NetLinx Master .................................................................... 43
Communicating with the On-board Master via an IP....................................................... 44
Verifying the current version of NetLinx Master Firmware .............................................. 46
Upgrading the On-board Master Firmware via an IP ...................................................... 46
Upgrading the NI Controller Firmware via an IP ............................................................. 48
Upgrading the new NI Controller firmware via an IP .............................................................. 49
Upgrading the Control Card Firmware via an IP ............................................................. 51
NetLinx Security and Web Server .........................................................................53
NetLinx Security web browser and feature support ............................................................... 53
New Master Firmware Security Features........................................................................ 54
NetLinx Security Terms................................................................................................... 54
Accessing the NetLinx Master via its IP Address............................................................ 55
WebControl Tab .............................................................................................................. 55
Default Security Configuration ........................................................................................ 56
Security Tab .................................................................................................................... 57
Security tab - Enable Security page....................................................................................... 58
Security tab - Add Group page............................................................................................... 59
Security tab - Modify Group page .......................................................................................... 60
Security tab - Group Directory Associations page ................................................................. 61
Security tab - Add User page ................................................................................................. 63
Table of Contents
iii
NetLinx Integrated Controllers
Security tab - Modify User page............................................................................................. 64
Security tab - User Directory Associations page .................................................................... 65
Security tab - SSL Server Certificate page ............................................................................ 67
Security tab - Export Certificate Request page ...................................................................... 69
Security tab - Import Certificate page..................................................................................... 69
System Tab ..................................................................................................................... 70
Show Devices Tab .......................................................................................................... 70
Network Tab .................................................................................................................... 70
Master Security Setup Procedures.................................................................................. 71
Setting the system security options for a NetLinx Master (Security Options Menu) .............. 71
Adding a Group and assigning their access rights................................................................. 72
Modifying an existing Group’s access rights .......................................................................... 73
Showing a list of authorized Groups ...................................................................................... 74
Deleting an existing Group..................................................................................................... 74
Adding a Group directory association .................................................................................... 75
Confirming the new directory association .............................................................................. 76
Deleting a directory association ............................................................................................. 76
Adding a User and configuring their access rights ................................................................. 77
Modifying an existing User’s access rights ............................................................................ 78
Showing a list of authorized Users......................................................................................... 79
Deleting a User ...................................................................................................................... 79
Adding a User directory association....................................................................................... 80
Confirming the new directory association .............................................................................. 81
Deleting a directory association ............................................................................................. 81
SSL Certificate Procedures ............................................................................................. 81
Self-Generating a SSL Server Certificate Request ................................................................ 82
Creating a Request for a SSL Server Certificate ................................................................... 83
Importing a CA certificate to the Master over a secure SSL connection................................ 84
Display SSL Server Certificate Information............................................................................ 85
Regenerating an SSL Server Certificate Request.................................................................. 85
Common Steps for Requesting a Certificate from a CA.................................................. 86
Accessing an SSL-Enabled Master via an IP Address.................................................... 88
Using your NetLinx Master to control the G4 panel ............................................................... 90
Using your NetLinx Master to control the G3 panel ............................................................... 91
What to do when a Certificate Expires ............................................................................ 92
NetLinx Security with a Terminal Connection .....................................................93
NetLinx Security Features ............................................................................................... 93
Initial Setup via a Terminal Connection........................................................................... 93
Establishing a Terminal connection ....................................................................................... 93
iv
NetLinx Integrated Controllers
Table of Contents
Accessing the Security configuration options.................................................................. 94
Option 1 - Set system security options for NetLinx Master (Security Options Menu) ............ 95
Option 2 - Display system security options for NetLinx Master .............................................. 96
Option 3 - Add user ................................................................................................................ 96
Option 4 - Edit User................................................................................................................ 97
Option 5 - Delete user ............................................................................................................ 99
Option 6 - Show the list of authorized users .......................................................................... 99
Option 7 - Add Group ............................................................................................................. 99
Option 8 - Edit Group ........................................................................................................... 102
Option 9 - Delete Group ....................................................................................................... 102
Option 10 - Show List of Authorized Groups........................................................................ 103
Option 11 - Set Telnet Timeout in seconds.......................................................................... 103
Option 12 - Display Telnet Timeout in seconds ................................................................... 103
Option 13 - Make changes permanent by saving to flash .................................................... 103
Main Security Menu ...................................................................................................... 104
Default Security Configuration ...................................................................................... 105
Help menu............................................................................................................................ 106
Logging Into a Session.................................................................................................. 107
Logout ........................................................................................................................... 108
Help Security........................................................................................................................ 108
Setup Security...................................................................................................................... 108
Programming ........................................................................................................109
Converting Axcess Code to NetLinx Code.................................................................... 109
Using the ID Button ....................................................................................................... 109
Device:Port:System (D:P:S)................................................................................................. 109
Program Port Commands ............................................................................................. 110
ESC Pass Codes .......................................................................................................... 113
Notes on Specific Telnet/Terminal Clients .................................................................... 113
WindowsTM client programs ................................................................................................ 113
Linux Telnet client ................................................................................................................ 114
LED Disable/Enable Send_Commands ........................................................................ 114
RS-232/422/485 Send_Commands .............................................................................. 114
RS-232/422/485 Send_String Escape Sequences ....................................................... 117
IR / Serial Ports Channels............................................................................................. 118
IR RX Port Channels..................................................................................................... 118
IR/Serial Send_Commands........................................................................................... 118
Input/Output Send_Commands..................................................................................... 123
Troubleshooting ...................................................................................................125

Introduction

1
NetLinx Integrated Controllers
Introduction
NetLinx Integrated Master Controllers can be programmed to control RS-232/422/485, Relay, IR/
Serial, and Input/Output devices through the use of both the NetLinx programming language and
the NetLinx Studio application (version 2.2 or higher). Another key feature of this products is the
ability to easily access the configuration switches without having to remove a
cover plate.
The NI series of controllers use a combination lithium battery and clock crystal package called a
Timekeeper. Only one Timekeeper unit is installed within a given NI controller. The battery can be
expected to have up to 3 years of usable life under very adverse conditions. Actual life is
appreciably longer under normal operating conditions. This calculation is based on storing the unit
without power in 50° C (120° F) temperature until battery levels are no longer acceptable. The part
number for a replacement battery is 57-0032.

NI-2000 Specifications

The front panel LEDs (FIG. 1) are grouped by control type and are numbered according to their
corresponding port (connector) numbers on the rear of the unit. The back of the unit contains
three RS-232/422/485, one Relay, one IR/Serial and one I/O connectors. In addition, this unit
provides an ID pushbutton, AXlink LED, and other related connectors. FIG. 2 shows the front and
rear of the NI-2000.
NetLinx Integrated Master Controller Features
NI-2000
(FG2105-01)
1 RS-232 Program port
3 RS-232/RS-422/RS-485 ports
4 IR/Serial Output ports
4 Digital Input/Output ports
•4 Relays
NI-3000
(FG2105-02)
1 RS-232 Program port
7 RS-232/RS-422/RS-485 ports
8 IR/Serial Output ports
8 Digital Input/Output ports
•8 Relays
NI-4000
(FG2105)
Support for up to 4 NetLinx control cards (such as NXC-COM2, NXC-IRS4, etc.)
1 RS-232 Program port
7 RS-232/RS-422/RS-485 ports
8 IR/Serial Output ports
8 Digital Input/Output ports
•8 Relays
Introduction
2
NetLinx Integrated Controllers
FIG. 1 NI-2000 NetLinx Integrated Controller (front view)
FIG. 2 NI-2000 front and rear panel components
NI-2000 Specifications
Dimensions (HWD): 3.47" x 17.00" x 3.47" (8.81 cm x 43.18 cm x 8.82 cm)
2 RU (rack unit) high
Power requirements: 700 mA @ 12 VDC
Memory: 32 MB SDRAM
1 MB of Non-volatile Flash
Compact Flash: 32 MB Card (upgradeable). Refer to the Optional Accessories section on
page 5 for more information.
Weight: 4.50 lbs (2.04 kg)
Enclosure: Metal with black matte finish
AXLink LED
Relays
RS-232/422/485 (Ports 1-3)
I/O (Port 9)
IR/Serial (Ports 5-8)
Front
Rear
Program
DIP
switch
ICSNet (2)
ICSHub Out
(green)
ID Pushbutton
(Port 4)
Ethernet
AXLink
port
PWR
RS-232/422/485 TX/RX LEDs (red/yellow)
Relay LEDs (red)
IR/Serial LEDs (red)
I/O LEDs
port
Link/Active-Status-Output-Input
(yellow)
Introduction
3
NetLinx Integrated Controllers
NI-2000 Specifications (Cont.)
Front Panel Components:
LINK/ACT Green LED lights when the Ethernet cable is connected and an active link
is established. This LED also blinks when receiving Ethernet data packets.
Status Green LED lights to indicate that the system is programmed and
communicating properly.
Output Red LED lights when the Controller transmits data, sets channels On/Off,
sends data strings, etc.
Input Yellow LED blinks when the Controller receives data from button pushes,
strings, commands, channel levels, etc.
RS-232/422/485 LEDs Three sets of red and yellow LEDs light to indicate the rear DB9 Ports 1-3
are transmitting or receiving RS-232, 422, or 485 data:
- TX LEDs (red) light when transmitting data
- RX LEDs (yellow) light when receiving data
- LED activity reflects transmission and reception activity
Relay LEDs Four red LEDs light to indicate the rear relay channels 1-4 are active
(closed).
These LEDs reflect the state of the relay on Port 4
If the relay is engaged = LED On and if the relay is Off = LED Off
IR/Serial LEDs Four red LEDs light to indicate the rear IR/Serial channels 1-4 are
transmitting control data on Ports 5-8
LED indictor for each IR port remains lit for the length of time that IR/Serial
data is being generated
I/O LEDs Four yellow LEDs light when the rear I/O channels 1-4 are active
LED indicator for each I/O port reflects the state of that particular port
Rack-mount brackets Provide an installation option for the Integrated Controller to be mounted
into an equipment rack.
Rear Panel Components:
RS-232/422/485 (Ports 1 -3) Three RS-232/422/485 control ports using DB9 (male) connectors with
XON/XOFF (transmit On/transmit Off), CTS/RTS (clear to send/ready to
send), and 300-115,200 baud.
Channel range = 1-255
Channels 1-254 provide feedback
Channel 255 (CTS Push channel): Reflects the state of the CTS Input if a
'CTSPSH' command was sent to the port
Output data format for each port is selected via software
Three DB9 connectors provide RS-232/422/485 termination
ICSNet Two RJ-45 connectors for ICSNet interface
ICSHub Out Single RJ-45 connector provides data to another Hub connected to the
Controller
Relay (Port 4) Four-channel single-pole single-throw relay ports
Each relay is independently controlled.
Supports up to 4 independent external relay devices
Channel range = 1-4
Each relay can switch up to 24 VDC or 28 VAC @ 1 A
One 8-pin 3.5 mm mini-Phoenix (female) connector provides relay
termination
Introduction
4
NetLinx Integrated Controllers
NI-2000 Specifications (Cont.)
Digital I/O (Port 9) Four-channel binary I/O port for contact closure
Each input is capable of voltage sensing. Input format is software
selectable.
Interactive power sensing for IR ports
Channel range = 1-4
All inputs are assigned to respective IR/Serial ports for "automatic" power
control through the use of software commands. Power control is provided
via commands such as: ’PON’, ’POF’, ’POD’, ’DELAY’, I/O Link etc.).
Contact closure between GND and an I/O port is detected as a PUSH
When used as voltage input - I/O port detects a low signal (0- 1.5 VDC) as
a PUSH and a high signal (3.5 - 5 VDC) as a RELEASE
When used as an output - each I/O port acts as a switch to GND and is
rated at 200 mA @ 12 VDC
One 6-pin 3.5 mm mini-Phoenix (female) connector provides I/O port
termination
IR/Serial (Ports 5-8) Four IR/Serial control ports suppor t high-frequency carriers up to
1.142 MHz
Each output is capable of two electrical formats: IR or Serial
Four IR/Serial data signals can be generated simultaneously.
Channel range = 1-32,767
Channels 1-128 (output): IR commands
Channels 129-253: used as reference channels
Channel 254 (feedback): Power Fail (used with 'PON' and 'POF'
commands)
Channel 255 (feedback): Power status (when IO Link is set)
One 8-pin 3.5 mm mini-Phoenix (female) connector provides IR/Serial port
termination
IR/Serial (Ports 5-8) Four IR/Serial control ports suppor t high-frequency carriers up to 1.142
MHz
Each output is capable of two electrical formats: IR or Serial
Four IR/Serial data signals can be generated simultaneously
Channel range = 1-32,767
Channels 1-128 (output): IR commands
Channels 129-253: used as reference channels
Channel 254 (feedback): Power Fail (used with 'PON' and 'POF'
commands)
Channel 255 (feedback): Power status (when IO Link is set)
One 8-pin 3.5 mm mini-Phoenix (female) connector provides IR/Serial port
termination
Program port Single RS-232 DB9 connector (male) can be connected to a DB9 port on a
computer; used with serial commands, NetLinx programming commands,
other DB9 capable devices, and to upload/download information from the
NetLinx Studio 2.2 program.
Configuration DIP switch Use this DIP switch to set the communication parameters for the rear
RS232 Program port.
ID pushbutton Sets the NetLinx ID (D) assignment for the device.
The D notation is used to explicitly represent a device number.
Ethernet port Single RJ-45 port for 10/100 Mbps communication. The Ethernet Port
automatically negotiates the connection speed (10 Mbps or 100 Mbps) and
whether to use half duplex or full duplex mode.
Introduction
5
NetLinx Integrated Controllers

NI-3000 Specifications

The front LEDs (FIG. 3) are grouped by control type and are numbered according to their
corresponding port (connector) numbers on the rear of the unit. The back of the this unit contains
RS-232/422/485, Relay, IR/Serial and I/O connectors. In addition, this unit provides an ID
pushbutton, AXlink LED, and other related connectors. FIG. 4 shows the front and rear of the
NI-3000.
NI-2000 Specifications (Cont.)
Ethernet Link/Activity LED LEDs show communication activity, connections, speeds, and mode
information:
SPD-speed - Yellow LED lights On when the connection speed is 100 Mbps
and turns Off when the speed is 10 Mbps.
L/A-link/activity - Green LED lights On when the Ethernet cables are
connected/terminated correctly and blinks when receiving Ethernet data
packets.
AXlink LED One green LED indicates the state of the AXlink connector port.
Normal AXlink activity = 1 blink/second
Abnormal AXLink activity = cycle of 3 consecutive blinks and then Off
AXlink port 4-pin 3.5 mm mini-Phoenix (male) connector provides data and power to
external control devices.
Power port 2-pin 3.5 mm mini-Phoenix (male) connector
Included Accessories: 2 CC-NIRC IR Emitters (FG10-000-11)
Installation Kit (KA2105-01):
One 8-pin Relay Common Strip (41-2105-01)
Four rack mount screws (80-0186)
Four washers (80-0342)
One 8-pin 3.5 mm mini-Phoenix (female) Relay connector (41-5083)
One 6-pin 3.5 mm mini-Phoenix (female) I/O connector (41-5063)
One 4-pin 3.5 mm mini-Phoenix (female) AXlink connector (41-5047)
One 2-pin 3.5 mm mini-Phoenix (female) PWR connector (41-5025)
Removable rack ears. Allows for tabletop and under-counter mountings
Optional Accessories: 2 Pin Black Male Phoenix Connector (3.5mm) (41-5026)
CC-NIRC IR cables (FG10-000-11)
CC-NSER IR/Serial cables (FG10-007-10)
CSB Cable Support Bracket (FG517)
NCK, NetLinx Connector Kit (FG2902)
NI-2000 Quick Start Guide (93-2105-01)
PSN2.8 12 VDC power supply (FG423-17)
PSN6.5 12 VDC power supply (FG423-41)
STS, Serial To Screw Terminal (FG959)
Upgrade Compact Flash (factory programmed with firmware):
NXA-CFNI64M - 64 MB compact flash card (FG2116-31)
NXA-CFNI128M - 128 MB compact flash card (FG2116-32)
NXA-CFNI256M - 256 MB compact flash card (FG2116-33)
NXA-CFNI512M - 512 MB compact flash card (FG2116-34)
NXA-CFNI1G - 1 GB compact flash card (FG2116-35)
Introduction
6
NetLinx Integrated Controllers
FIG. 3 NI-3000 NetLinx Integrated Controller (front view)
FIG. 4 NI-3000 front and rear panel components
AXLink LED
Relays
RS-232/422/485 (Ports 1-7)
I/O (Port 17)
IR/Serial (Ports 9-16)
Front
Rear
Program
DIP
switch
ICSNet (2)
ICSHub Out
(green)
ID Pushbutton
(Port 8)
Ethernet
AXLink
port
PWR
RS-232/422/485 TX/RX LEDs (red/yellow)
Relay LEDs (red)
IR/Serial LEDs (red)
I/O LEDs (yellow)
port
Link/Active-Status-Output-Input
Introduction
7
NetLinx Integrated Controllers
NI-3000 Specifications (Cont.)
Dimensions (HWD): 3.47" x 17.00" x 3.47" (8.81 cm x 43.18 cm x 8.82 cm)
2 RU (rack unit) high
Power requirements: 900 mA @ 12 VDC
Memory: 32 MB SDRAM
1 MB of Non-volatile Flash
Compact Flash: 32 MB Card (upgradeable). Refer to the Optional Accessories section on
page 10 for more information.
Weight: 4.55 lbs (2.06 kg)
Enclosure: Metal with black matte finish
Front Panel Components:
LINK/ACT Green LED lights when the Ethernet cable is connected and an active link
is established. This LED also blinks when receiving Ethernet data packets.
Status Green LED lights to indicate that the system is programmed and
communicating properly.
Output Red LED lights when the Controller transmits data, sets channels On/Off,
sends data strings, etc.
Input Yellow LED lights when the Controller receives data from button pushes,
strings, commands, channel levels, etc.
RS-232/422/485 LEDs Seven sets of red and yellow LEDs light to indicate the rear DB9 Ports 1-7
are transmitting or receiving RS-232, 422, or 485 data:
- TX LEDs (red) light when transmitting data
- RX LEDs (yellow) light when receiving data
- LED activity reflects transmission and reception activity
Relay LEDs Eight red LEDs light to indicate the rear relay channels 1-8 are active
(closed)
These LEDs reflect the state of the relay on Port 8
If the relay is engaged = LED On and if the relay is Off = LED Off
IR/Serial LEDs Eight red LEDs light to indicate the rear IR/Serial channels 1-8 are
transmitting control data on Ports 9-16
LED indictor for each IR port remains lit for the length of time that IR/Serial
data is being generated
I/O LEDs Eight yellow LEDs light when the rear I/O channels 1-8 are active
LED indicator for each I/O port reflects the state of that particular port
Rack-mount brackets Provide an installation option for the Integrated Controller to be mounted
into an equipment rack.
Introduction
8
NetLinx Integrated Controllers
NI-3000 Specifications (Cont.)
Rear Panel Components:
RS-232/422/485 (Ports 1 -7) Seven RS-232/422/485 control ports using DB9 (male) connectors with
XON/XOFF (transmit on/transmit off), CTS/RTS (clear to send/ready to
send), and 300-115,200 baud.
Channel range = 1-255
Channels 1-254 provide feedback
Channel 255 (CTS Push channel): Reflects the state of the CTS Input if a
'CTSPSH' command was sent to the port
Output data format for each port is selected via software
Seven DB9 connectors provide RS-232/422/485 termination
ICSNet Two RJ-45 connectors for ICSNet interface
ICSHub Out Single RJ-45 connector provides data to another Hub connected to the
Controller
Relay (Port 8) Eight-channel single-pole single-throw relay ports
Each relay is independently controlled.
Supports up to 8 independent external relay devices
Channel range = 1-8
Each relay can switch up to 24 VDC or 28 VAC @ 1 A
Two 8-pin 3.5 mm mini-Phoenix (female) connectors provide relay
termination
Digital I/O (Port 17) Eight-channel binary I/O port for contact closure
Each input is capable of voltage sensing. Input format is software
selectable.
Interactive power sensing for IR ports
Channel range = 1-8
All inputs are assigned to respective IR/Serial ports for "automatic" power
control through the use of software commands. Power control is provided
via commands such as: ’PON’, ’POF’, ’POD’, ’DELAY’, I/O Link etc.).
Contact closure between GND and an I/O port is detected as a PUSH
When used as voltage input - I/O port detects a low signal (0- 1.5 VDC) as
a PUSH and a high signal (3.5 - 5 VDC) as a RELEASE
When used as an output - each I/O port acts as a switch to GND and is
rated at 200 mA @ 12 VDC
One 10-pin 3.5 mm mini-Phoenix (female) connector provides I/O port
termination
IR/Serial (Ports 9-16) Eight IR/Serial control por ts support high-frequency carriers up to
1.142 MHz
Each output is capable of two electrical formats: IR or Serial
Eight IR/Serial data signals can be generated simultaneously.
Channel range = 1-32,767
Channels 1-128 (output): IR commands
Channels 129-253: used as reference channels
Channel 254 (feedback): Power Fail (used with 'PON' and 'POF'
commands)
Channel 255 (feedback): Power status (when IO Link is set)
Two 8-pin 3.5 mm mini-Phoenix (female) connectors provide IR/Serial port
termination
Introduction
9
NetLinx Integrated Controllers
NI-3000 Specifications (Cont.)
IR/Serial (Ports 9-16) Eight IR/Serial control por ts support high-frequency carriers up to
1.142 MHz
Each output is capable of two electrical formats: IR or Serial
Eight IR/Serial data signals can be generated simultaneously
Channel range = 1-32,767
Channels 1-128 (output): IR commands
Channels 129-253: used as reference channels
Channel 254 (feedback): Power Fail (used with 'PON' and 'POF'
commands)
Channel 255 (feedback): Power status (when IO Link is set)
Two 8-pin 3.5 mm mini-Phoenix (female) connectors provide IR/Serial port
termination
Program port Single RS-232 DB9 connector (male) can be connected to a DB9 port on a
computer; used with serial commands, NetLinx programming commands,
other DB9 capable devices, and to upload/download information from the
NetLinx Studio 2.2 program.
Configuration DIP switch Use this DIP switch to set the communication parameters for the rear
RS232 Program port.
ID pushbutton Sets the NetLinx ID (D) assignment for the device.
The D notation is used to explicitly represent a device number.
Ethernet port Single RJ-45 port for 10/100 Mbps communication. The Ethernet Port
automatically negotiates the connection speed (10 Mbps or 100 Mbps) and
whether to use half duplex or full duplex mode.
Ethernet Link/Activity LED LEDs show communication activity, connections, speeds, and mode
information:
SPD-speed - Yellow LED lights On when the connection speed is 100 Mbps
and turns Off when the speed is 10 Mbps.
L/A-link/activity - Green LED lights On when the Ethernet cables are
connected/terminated correctly and blinks when receiving Ethernet data
packets.
AXlink LED One green LED indicates the state of the AXlink connector port.
Normal AXlink activity = 1 blink/second
Abnormal AXLink activity = cycle of 3 consecutive blinks and then Off
AXlink port 4-pin 3.5 mm mini-Phoenix (male) connector provides data and power to
external control devices.
Power port 2-pin 3.5 mm mini-Phoenix (male) connector
Included Accessories: 4 CC-NIRC IR Emitters (FG10-000-11)
One 10-pin 3.5 mm mini-Phoenix (female) I/O connector (41-5107)
Two 8-pin 3.5 mm mini-Phoenix (female) Relay connector (41-5083)
One 4-pin 3.5 mm mini-Phoenix (female) AXlink connector (41-5047)
One 2-pin 3.5 mm mini-Phoenix (female) PWR connector (41-5025)
Installation Kit (KA2105-01):
One 8-pin Relay Common Strip (41-2105-01)
Four rack mount screws (80-0186)
Four washers (80-0342)
Removable rack ears. Allows for tabletop and under-counter mountings
Introduction
10
NetLinx Integrated Controllers

NI-4000 Specifications

The front LEDs (FIG. 5) are grouped by control type, and are numbered according to their
corresponding port (connector) numbers on the rear of the unit. The back of the this unit contains
RS-232/422/485, Relay, IR/Serial and I/O connectors. In addition, this unit provides an ID
pushbutton, AXlink LED, NetLinx Card slots, and other related connectors. FIG. 6 shows the front
and rear of the NI-4000.
NI-3000 Specifications (Cont.)
Optional Accessories: 2 Pin Black Male Phoenix Connector (3.5mm) (41-5026)
CC-NIRC IR cables (FG10-000-11)
CC-NSER IR/Serial cables (FG10-007-10)
CSB Cable Support Bracket (FG517)
NCK, NetLinx Connector Kit (FG2902)
NI-3000 Quick Start Guide (93-2105-01)
PSN2.8 12 VDC power supply (FG423-17)
PSN6.5 12 VDC power supply (FG423-41)
STS, Serial To Screw Terminal (FG959)
Upgrade Compact Flash (factory programmed with firmware):
NXA-CFNI64M - 64 MB compact flash card (FG2116-31)
NXA-CFNI128M - 128 MB compact flash card (FG2116-32)
NXA-CFNI256M - 256 MB compact flash card (FG2116-33)
NXA-CFNI512M - 512 MB compact flash card (FG2116-34)
NXA-CFNI1G - 1 GB compact flash card (FG2116-35)
FIG. 5 NI-4000 NetLinx Integrated Controller (front view)
Introduction
11
NetLinx Integrated Controllers
FIG. 6 NI-4000 front and rear panel components
NI-4000 Specifications
Dimensions (HWD): 5.21" x 17.00" x 9.60" (13.23 cm x 43.18 cm x 24.27 cm)
3 RU (rack unit) high
Power requirements: 900 mA @ 12 VDC (no cards)
Memory: 32 MB SDRAM
1 MB of Non-volatile Flash
Compact Flash: 32 MB Card (upgradeable). Refer to the Optional Accessories section on
page 14 for more information.
Weight: 9.15 lbs (4.15 kg)
Enclosure: Metal with black matte finish
Front Panel Components:
LINK/ACT Green LED lights when the Ethernet cable is connected and an active link
is established. This LED also blinks when receiving Ethernet data packets.
Status Green LED lights to indicate that the system is programmed and
communicating properly.
Output Red LED lights when the Controller transmits data, sets channels On/Off,
sends data strings, etc.
Input Yellow LED lights when the Controller receives data from button pushes,
strings, commands, channel levels, etc.
RS-232/422/485 LEDs Seven sets of red and yellow LEDs light to indicate the rear DB9 Ports 1-7
are transmitting or receiving RS-232, 422, or 485 data:
- TX LEDs (red) light when transmitting data
- RX LEDs (yellow) light when receiving data
- LED activity reflects transmission and reception activity
AXLink LED
Relays
RS-232/422/485 (Ports 1-7)
I/O (Port 17)
IR/Serial (Ports 9-16)
Front
Rear
Program port
DIP
switch
ICSNet (2)
ICSHub Out
(green)
ID Pushbutton
(Port 8)
Ethernet
AXLink
port
PWR
CardFrame DIP
switch
Slot 1-4 connectors
NetLinx
Card
slots
(1-4)
RS-232/422/485 TX/RX LEDs (red/yellow)
Relay LEDs (red)
IR/Serial LEDs (red)
I/O LEDs (yellow)
Link/Active-Status-Output-Input
Introduction
12
NetLinx Integrated Controllers
NI-4000 Specifications (Cont.)
Relay LEDs Eight red LEDs light to indicate the rear relay channels 1-8 are active
(closed)
These LEDs reflect the state of the relay on Port 8
If the relay is engaged = LED On and if the relay is Off = LED Off
IR/Serial LEDs Eight red LEDs light to indicate the rear IR/Serial channels 1-8 are
transmitting control data on Ports 9-16
LED indictor for each IR port remains lit for the length of time that IR/Serial
data is being generated
I/O LEDs Eight yellow LEDs light when the rear I/O channels 1-8 are active
LED indicator for each I/O port reflects the state of that particular port
NetLinx Control
Card slots 1- 4
Accepts up to 4 compatible NetLinx Control Cards:
NXC-COM2 Dual COM Port Control Card (FG2022)
NXC-I/O10 Input/Output Control Card (FG2021)
NXC-IRS4 4-Port IR/S Control Card (FG2023)
NXC-REL10 Relay Control Card (FG2020)
NXC-VAI4 Analog Voltage Control Card (FG 2025)
NXC-VOL4 Volume Control Card (FG2024)
Rack-mount brackets Provide an installation option for the Integrated Controller to be mounted
into an equipment rack.
Rear Panel Components:
RS-232/422/485 (Ports 1 -7) Seven RS-232/422/485 control ports using DB9 (male) connectors with
XON/XOFF (transmit on/transmit off), CTS/RTS (clear to send/ready to
send), and 300-115,200 baud.
Channel range = 1-255
Channels 1-254 provide feedback
Channel 255 (CTS Push channel): Reflects the state of the CTS Input if a
'CTSPSH' command was sent to the port
Output data format for each port is selected via software
Seven DB9 connectors provide RS-232/422/485 termination
ICSNet Two RJ-45 connectors for ICSNet interface
ICSHub Out Single RJ-45 connector provides data to another Hub connected to the
Controller
Relay (Port 8) Eight-channel single-pole single throw relay ports
Each relay is independently controlled.
Supports up to 8 independent external relay devices
Channel range = 1-8
Each relay can switch up to 24 VDC or 28 VAC @ 1 A
Two 8-pin 3.5 mm mini-Phoenix (female) connectors provide relay
termination
Introduction
13
NetLinx Integrated Controllers
NI-4000 Specifications (Cont.)
Digital I/O (Port 17) Eight-channel binary I/O port for contact closure
Each input is capable of voltage sensing. Input format is software
selectable.
Interactive power sensing for IR ports
Channel range = 1-8
All inputs are assigned to respective IR/Serial ports for "automatic" power
control through the use of software commands. Power control is provided
via commands such as: ’PON’, ’POF’, ’POD’, ’DELAY’, I/O Link etc.).
Contact closure between GND and an I/O port is detected as a PUSH
When used as voltage input - I/O port detects a low signal (0- 1.5 VDC) as
a PUSH and a high signal (3.5 - 5 VDC) as a RELEASE
When used as an output - each I/O port acts as a switch to GND and is
rated at 200 mA @ 12 VDC
One 10-pin 3.5 mm mini-Phoenix (female) connector provides I/O port
termination
IR/Serial (Ports 9-16) Eight IR/Serial control por ts support high-frequency carriers up to
1.142 MHz
Each output is capable of two electrical formats: IR or Serial
Eight IR/Serial data signals can be generated simultaneously.
Channel range = 1-32,767
Channels 1-128 (output): IR commands
Channels 129-253: used as reference channels
Channel 254 (feedback): Power Fail (used with 'PON' and 'POF'
commands)
Channel 255 (feedback): Power status (when IO Link is set)
Two 8-pin 3.5 mm mini-Phoenix (female) connectors provide IR/Serial port
termination
Program port Single RS-232 DB9 connector (male) can be connected to a DB9 port on a
computer; used with serial commands, NetLinx programming commands,
other DB9 capable devices, and to upload/download information from the
NetLinx Studio 2.2 program.
Configuration DIP switch Use this DIP switch to set the communication parameters for the rear
RS232 Program port.
ID pushbutton Sets the NetLinx ID (D) assignment for the device.
The D notation is used to explicitly represent a device number.
Ethernet port Single RJ-45 port for 10/100 Mbps communication. The Ethernet Port
automatically negotiates the connection speed (10 Mbps or 100 Mbps) and
whether to use half duplex or full duplex mode.
Ethernet Link/Activity LED LEDs show communication activity, connections, speeds, and mode
information:
SPD-speed - Yellow LED lights On when the connection speed is 100 Mbps
and turns Off when the speed is 10 Mbps.
L/A-link/activity - Green LED lights On when the Ethernet cables are
connected/terminated correctly and blinks when receiving Ethernet data
packets.
AXlink LED One green LED indicates the state of the AXlink connector port.
Normal AXlink activity = 1 blink/second
Abnormal AXLink activity = cycle of 3 consecutive blinks and then Off
AXlink port 4-pin 3.5 mm mini-Phoenix (male) connector provides data and power to
external control devices.
Power port 2-pin 3.5 mm mini-Phoenix (male) connector
Introduction
14
NetLinx Integrated Controllers
NI-4000 Specifications (Cont.)
CardFrame Number
DIP switch
Sets the starting address for the Control Cards in the CardFrame.(Factory
default CardFrame DIP switch value = 0).
The Control Card address range is 1-3064.
NetLinx Control Card
connectors (1-4)
Four 20-pin (male) connectors that bridge the gap between the Control
Cards in the CardFrame and external equipment.
Included Accessories: Two CC-NIRC IR Emitters (FG10-000-11)
One 10-pin 3.5 mm mini-Phoenix (female) I/O connector (41-5107)
Two 8-pin 3.5 mm mini-Phoenix (female) Relay connector (41-5083)
One 4-pin 3.5 mm mini-Phoenix (female) AXlink connector (41-5047)
One 2-pin 3.5 mm mini-Phoenix (female) PWR connector (41-5025)
Installation Kit (KA2105-01):
One 8-pin Relay Common Strip (41-2105-01)
Four rack mount screws (80-0186)
Four washers (80-0342)
Removable rack ears. Allows for tabletop, under-counter, and
front/rear rack mounting
Optional Accessories: 2 Pin Black Male Phoenix Connector (3.5mm) (41-5026)
CC-NIRC IR cables (FG10-000-11)
CC-NSER IR/Serial cables (FG10-007-10)
CSB Cable Support Bracket (FG517)
NCK, NetLinx Connector Kit (FG2902)
NI-4000 Quick Start Guide (93-2105-01)
PSN2.8 12 VDC power supply (FG423-17)
PSN6.5 12 VDC power supply (FG423-41)
STS, Serial To Screw Terminal (FG959)
Upgrade Compact Flash (factory programmed with firmware):
NXA-CFNI64M - 64 MB compact flash card (FG2116-31)
NXA-CFNI128M - 128 MB compact flash card (FG2116-32)
NXA-CFNI256M - 256 MB compact flash card (FG2116-33)
NXA-CFNI512M - 512 MB compact flash card (FG2116-34)
NXA-CFNI1G - 1 GB compact flash card (FG2116-35)
NXC cards (see the Card Slot section (page 12) of this Specification table
for more detailed information)

Quick Setup and Configuration Overview

15
NetLinx Integrated Controllers
Quick Setup and Configuration Overview

Installation Procedures

These are the steps involved with the most common installation procedures of these devices:
Carefully unpack the contents of the box.
Confirm the contents of box (page 2 thru page 14).
Familiarize yourself with the units’ connectors and wiring configurations (Connections
and Wiring section on page 17).
Upgrade the factory default 32 MB memory module with a selection of memory sizes
ranging from 64 MB to 1 GB (Compact Flash Upgrades section on page 31), if
necessary.
Install any optional NXC Control Cards (Installing NetLinx Control Cards (NI-4000
Only) section on page 29).
Set the Control Card Address range (Setting the NetLinx Control Card Addresses (NI-
4000 Only) section on page 30) and a Device value (Device:Port:System (D:P:S) section
on page 30).
Set the communication speed on the Program Port DIP switch (Setting the Configuration
DIP Switch (for the Program Port) section on page 17). Default is 38400.
Connect all rear panel components and supply power to the NI unit from the optional
PSN power supply.

Configuration and Communication

These are the general steps involved with setting up and communicating with the Integrated
Controllers’ on-board Master. In the initial communication process:
Connect and communicate with the on-board Master by using the Program port
(Communicating with the Master via the Program Port section on page 37).
Setup the System Value being used with the on-board Master (Setting the System
Va l ue section on page 38).
Re-assign any Device values (Changing the Device Address on a NetLinx Device section
on page 40).
You can then either get a DHCP address for the on-board Master (Obtaining the Master’s
IP Address (using DHCP) section on page 42) or assign a Static IP to the on-board
Master (Assigning a Static IP to the NetLinx Master section on page 43).
Once the IP information is determined, rework the parameters for Master Communication
in order to connect to the on-board Master via the Ethernet and not the Program port
(Communicating with the On-board Master via an IP section on page 44).
Quick Setup and Configuration Overview
16
NetLinx Integrated Controllers

Update the Controller and Control Card Firmware

Before using your new Integrated Controller, you must FIRST update your NetLinx
Studio to the most recent release.
Upgrade the on-board Master firmware through an IP Address via the Ethernet connector
(Upgrading the On-board Master Firmware via an IP section on page 46)
(IP recommended).
Upgrade any connected NetLinx Control Cards being used within the NI-4000 unit
through an IP Address (Upgrading the Control Card Firmware via an IP Address section
on page 52).
Once programming of the on-board Master is complete and the NetLinx Control Cards
are installed; you can now finalize the installation process.
This installation process is done by replacing the faceplate on the NI-4000 (Installing
NetLinx Control Cards (NI-4000 Only) section on page 29) and installing the Controller
into an equipment rack (Installing the Integrated Controller into an Equipment
Rack section on page 34).

Program NetLinx Security into the On-Board Master

Setup and finalize your NetLinx Security Protocols (NetLinx Security and Web
Server section on page 53 or NetLinx Security with a Terminal Connection section on
page 93).
Program your NI Controller (Programming section on page 109).

Connections and Wiring

17
NetLinx Integrated Controllers
Connections and Wiring

Setting the Configuration DIP Switch (for the Program Port)

Prior to installing the Controller, use the Configuration DIP switch to set the baud rate used by the
Program port for communication. The Configuration DIP switch is located on the rear of the
NI-4000/3000/2000 Integrated Controllers.

Baud rate settings

Before programming the on-board Master, make sure the baud rate you set matches the
communication parameters set on both your PC’s COM port or and those set through your NetLinx
Studio 2.2. By default, the baud rate is set to 38,400 (bps).

Program Run Disable (PRD) mode

You can also use the Program port’s Configuration DIP switch to set the on-board Master to
Program Run Disable (PRD) mode according to the settings listed in the table below.
The PRD mode prevents the NetLinx program stored in the on-board Master from running when
you power up the Integrated Controller. This mode should only be used when you suspect the
resident NetLinx program is causing inadvertent communication and/or control problems. If
necessary, place the on-board Master in PRD mode and use the NetLinx Studio 2.2 program to
resolve the communication and/or control problems with the resident NetLinx program. Then
download the new NetLinx program and try again.
Baud Rate Settings on the Configuration DIP Switch
Baud Rate Position 5 Position 6 Position 7 Position 8
9600 bps OFF ON OFF ON
38,400 bps (default) OFF ON ON ON
57,600 bps ON OFF OFF OFF
115,200 bps ON ON ON ON
Note the orientation of the Configuration DIP Switch and the ON position label.
DIP switches 2,3, and 4 must remain in the OFF position at all times.
PRD Mode Settings
PRD Mode Position 1
Normal mode (default) OFF
PRD Mode ON
Connections and Wiring
18
NetLinx Integrated Controllers

Using the Configuration DIP switch

1. Disconnect the power supply from the 2-pin PWR (green) connector on the rear of the NetLinx
Integrated Controller.
2. Set DIP switch positions according to the information listed in the Baud Rate Settings on the
Configuration DIP Switch and PRD Mode Settings tables.
3. Reconnect the 12 VDC power supply to the 2-pin 3.5 mm mini-Phoenix PWR connector.

Modes and Front Panel LED Blink Patterns

The following table lists the modes and blink patterns for the front panel LEDs associated with
each mode. These patterns are not evident until after the unit is powered.

Wiring Guidelines

The Integrated Controllers require 12 VDC power from a NetLinx Power Supply to operate
properly (this supply is unit dependent). The Integrated Controller connects to the power supply via
a 2-pin 3.5 mm mini-Phoenix connector.
Think of the PRD Mode (On) equating to a PC’s SAFE Mode setting. This mode
allows a user to continue powering a unit, update the firmware, and download a new
program while circumventing any problems with a currently downloaded program.
Power must be cycled to the unit after activating/deactivating this mode on the
Program Port DIP switch #1.
Modes and LED Blink Patterns
LEDs and Blink Patterns
Mode Description
STATUS
(green)
OUTPUT
(red)
INPUT
(yellow)
OS Start Starting the operating system (OS). On On On
Boot On-board Master is booting. On Off On
Contacting DHCP
server
On-board Master is contacting a DHCP
server for IP configuration information.
On Off Fast Blink
Unknown DHCP
server
On-board Master could not find the
DHCP server.
Fast Blink Off Off
Downloading Boot
firmware
Downloading Boot firmware to the
Master’s on-board flash memory.
Do not cycle power during this process!
Fast Blink Fast Blink Fast Blink
No program running There is no program loaded, or the
program is disabled.
On Normal Normal
Normal On-board Master is functioning normally. 1 blink per second Indicates
activity
Indicates
activity
This unit should only have one source of incoming power. Using more than one
source of power to the Controller can result in damage to the internal components
and a possible burn out.
Apply power to the unit only after installation is complete.
Connections and Wiring
19
NetLinx Integrated Controllers

Preparing captive wires

You will need a wire stripper and flat-blade screwdriver to prepare and connect the captive wires.
1. Strip 0.25 inch (6.35 mm) of insulation off all wires.
2. Insert each wire into the appropriate opening on the connector (according to the wiring
diagrams and connector types described in this section).
3. Tighten the screws to secure the wire in the connector. Do not tighten the screws excessively,
doing so may strip the threads and damage the connector.

Wiring length guidelines

The NetLinx Integrated Controllers require auxiliary 12 VDC power from a PSN to operate
properly. The unit should only have one source of incoming power.
Refer to the following tables for the wiring length information used with the different types of
NetLinx Integrated Controllers:

Wiring a power connection

To use the NetLinx 2-pin 3.5 mm mini-Phoenix power supply jack for power transfer from the PSN
power supply, the incoming PWR and GND cables from the PSN must be connected to their
corresponding locations on the 2-pin 3.5 mm mini-Phoenix connector (FIG. 7).
Never pre-tin wires for compression-type connections.
Wiring Guidelines - NI-4000 & NI-3000@ 900 mA
Wire size Maximum wiring length
18 AWG 130.41 feet (39.75 meters)
20 AWG 82.51 feet (25.15 meters)
22 AWG 51.44 feet (15.68 meters)
24 AWG 32.43 feet (9.88 meters)
Wiring Guidelines - NI-2000 @ 700 mA
Wire size Maximum wiring length
18 AWG 167.67 feet (51.11 meters)
20 AWG 106.08 feet (32.33 meters)
22 AWG 66.14 feet (20.16 meters)
24 AWG 41.69 feet (12.71 meters)
FIG. 7 2-pin mini-Phoenix connector wiring diagram (direct power)
PWR +
GND -
To the Integrated Controller
NetLinx Power Supply
Connections and Wiring
20
NetLinx Integrated Controllers

Using the 4-pin mini-Phoenix connector for data and power

Connect the 4-pin 3.5 mm mini-Phoenix (female) captive-wire connector to an external NetLinx
device as shown in FIG. 8.

Using the 4-pin mini-Phoenix connector for data with external power

To use the NetLinx 4-pin 3.5 mm mini-Phoenix (female) captive-wire connector for data
communication and power transfer, the incoming PWR and GND cable from the PSN must be
connected to the AXlink cable connector going to the Integrated Controller. FIG. 9 shows the
wiring diagram. Always use a local power supply to power the Integrated Controller unit.
Make sure to connect only the GND wire on the AXlink/PWR connector when using a separate
12 VDC power supply. Do not connect the PWR wire to the AXlink connector’s PWR (+)
opening.
FIG. 8 Mini-Phoenix connector wiring diagram (direct data and power)
FIG. 9 4-pin mini-Phoenix connector wiring diagram (using external power source)
To the Integrated Controller’s
To the external NetLinx device
AXlink/PWR connector
PWR +
AXP/TX
AXM/RX
GND -
Top view
Top view
PWR +
AXP/TX
AXM/RX
GND -
PWR (+)
GND (-)
Local +12 VDC
(coming from
To the Integrated Controller’s
To the external NetLinx device
AXlink/PWR connector
power supply
the PSN
power supply)
Top view
Top view
AXP/TX
AXM/RX
GND -
AXP/TX
AXM/RX
GND -
When you connect an external power supply, do not connect the wire from the PWR
terminal (coming from the external device) to the PWR terminal on the Phoenix
connector attached to the Controller unit. Make sure to connect only the AXM, AXP,
and GND wires to the Controller’s Phoenix connector when using an external PSN
power supply.
Connections and Wiring
21
NetLinx Integrated Controllers

Program Port Connections and Wiring

The Integrated Controllers are equipped with one Program port located on the rear of the unit. Use
an RS232 programming cable to connect the Program port to your PC's COM port, this connection
provides communication with the NetLinx Integrated Controller. Then you can download NetLinx
programs to this on-board Master using the NetLinx Studio 2.2 software program. Refer to the
NetLinx Studio instruction manual for programming instructions.
The following table shows the rear panel Program Port connector (male), pinouts, and signals.

RS-232/422/485 Device Port Wiring Specifications

FIG. 10 shows the connector pinouts for the rear RS-232/RS-422/RS-485 (DB9) Device Ports.
These ports support most standard RS-232 communication protocols for data transmission. This
figure gives a visual representation of the wiring specifications for the RS-232/422/485 Device
connectors. Refer to the rear of the unit for more detailed connector pinout information.
The rear DB9 Device Port connectors support RS-232 communication protocols for PC data
transmission. The table below provides information about the connector pins, signal types, and
signal functions. This table’s wiring specifications are applicable to the rear RS-232/422/485
Device Port connectors on the: NI-4000/NI-3000 (Ports 1-7) and NI-2000 (Ports 1-3).
Program Port, Pinouts, and Signals
Program Port Connector Pin Signal
2RX
3TX
5GND
7RTS
8CTS
FIG. 10 RS-232/422/485 DB9 (male/female) connector pinouts for the rear Device Ports
5
4
3
2
1
9
8
7
6
Male
5
4
3
2
1
9
8
7
6
Male
DB9 Serial Port pinouts (male connector)
Pin 2: RX signal
Pin 3: TX signal
Pin 5: GND
Pin 7: RTS
Pin 8: CTS
RS-232
Pin 1: RX -
Pin 4: TX +
Pin 5: GND
Pin 6: RX +
Pin 9: TX -
RS-422
Pin 1: A (strap to 9)
Pin 4: B (strap to 6)
Pin 5: GND
Pin 6: B (strap to 4)
Pin 9: A (strap to 1)
RS-485
Connections and Wiring
22
NetLinx Integrated Controllers

ICSNet RJ-45 Connections/Wiring

The following tables show the signal and pinouts/pairing information to use for ICSNet RJ-45
connections.
RS-232/422/485 Device Port Wiring Specifications
Pin Signal Function RS-232 RS-422 RS-485
1 RX- Receive data X X (strap to pin 9)
2 RXD Receive data X
3 TXD Transmit data X
4 TX+ Transmit data X X (strap to pin 6)
5 GND Signal ground X X
6 RX+ Receive data X X (strap to pin 4)
7 RTS Request to send X
8 CTS Clear to send X
9 TX- Transmit data X X (strap to pin 1)
ICSNet RJ-45 Signals
Pin Signal-Master Signal-Device
1 TX + RX +
2 TX - RX -
3N/A N/A
4GND GND
5N/A N/A
6N/A N/A
7 RX + TX +
8 RX - TX -
RJ-45 Pinout Information (EIA/TIA 568 B)
Pin Wire Color Polarity Function
1 Orange/White + Transmit
2 Orange - Transmit
3 Green/White - Mic
4 Blue - Ground
5 White/Blue + 12 VDC
6 Green + Mic
7 White/Brown + Receive
8 Brown - Receive
TIA 568B
1
2
3
4
5
6
7
8
1 2 3 4 5 6 7 8
RJ-45 connector - pin configurations
(female) (male)
Connections and Wiring
23
NetLinx Integrated Controllers
The FIG. 11 illustrates the relative location of the ICSNet and ICSHub Out connectors on the rear
panel.

ICSHub OUT port

The following table describes the pinout/signal information for the ICSHub OUT port located on
the rear panel of the Integrated Controller (as shown in FIG. 11).

Ethernet 10/100 Base-T RJ-45 Connections/Wiring

The following table lists the pinouts and signals associated to the Ethernet connector. FIG. 12
describes the RJ-45 pinouts, signals, and pairing for the Ethernet 10/100 Base-T RJ-45 connector
and cable.
FIG. 12 diagrams the RJ-45 cable and connectors.
FIG. 11 Location of ICSNet and ICSHub Out connectors
PORT 1
Por ts
ICSNet
ICSNet ICSHub Out
Unlike the ICSNet ports, the ICSHub connections require a specific polarity. The
IN/OUT configuration, on the hub ports, was implemented to use the same cables as
ICSNet, but these ports need TX and RX crossed. You must connect an OUT to an
IN, or an IN to an OUT port.
This is done simply to keep the polarity straight. The Hub bus is still a bus. All Hub
connections are bi-directional.
ICSHub OUT Pinouts and Signals
Pin Signal Color
1 RX + orange-white
2 RX - orange
3 ------ ------
4 ------ ------
5 ------ ------
6 ------ ------
7TX + brown-white
8TX - brown
Ethernet RJ-45 Pinouts and Signals
Pin Signals Connections Pairing Color
1 TX + 1 --------- 1 1 --------- 2 Orange-White
2 TX - 2 --------- 2 Orange
3 RX + 3 --------- 3 3 --------- 6 Green-White
4 no connection 4 --------- 4 Blue
5 no connection 5 --------- 5 Blue-White
6 RX - 6 --------- 6 Green
7 no connection 7 --------- 7 Brown-White
8 no connection 8 --------- 8 Brown
Connections and Wiring
24
NetLinx Integrated Controllers
Ethernet LEDs

Ethernet ports used by the Integrated Controllers

Relay Connections and Wiring

You can connect up to 8 independent external relay devices on both the NI-4000 and NI-3000 units
(4 on the NI-2000) to the Relay connectors on the Integrated Controller (Port 7).
Connectors labeled A are for common; B are for output.
Each relay is isolated and normally open.
FIG. 12 RJ-45 wiring diagram
FIG. 13 Layout of Ethernet LEDs
Ethernet Ports Used by the NetLinx Integrated Controllers
Port type Description Standard Port #
ICSP Peer-to-peer protocol used for both Master-to-Master and Master-to-device
communications.
For maximum flexibility, the on-board Master can be configured to utilize a
different port than 1319, or disable ICSP over Ethernet completely from
either Telnet or the Program Port located on the rear of the Controller itself.
1319 (UDP/TCP)
Telnet The NetLinx Telnet server provides a mechanism to configure and
diagnose a NetLinx system.
For maximum flexibility, the on-board Master can be configured to utilize a
different port than 23, or disable Telnet completely from either Telnet or the
Program Port located on the rear of the Controller itself. Once disabled, the
only way to enable Telnet again is from the Controller’s program port.
23 (TCP)
HTTP The on-board Master has a built-in web server that complies with the
HTTP 1.0 specification and supports all of the required features of
HTTP v1.1.
80 (TCP)
HTTPS The Master has a built-in SSL protected web server. 443 (TCP)
FTP The on-board Master has a built-in FTP server that conforms to RFC959. 21/20 (TCP)
Internet Inside The Internet Inside feature the on-board Master uses, by default, is port
10500 for the XML based communication protocol. This port is connected
to the client web browser’s JVM when Internet Inside control pages are
retrieved from the on-board Master’s web server.
For maximum flexibility, the on-board Master can be configured to utilize a
different port than 10500 or to disable Internet Inside completely.
10500 (TCP)
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
RJ-45
plug
RJ-45
plug
10/100
ETHERNET
SPD - Speed LED
connection speed is 100 Mbps
and turns Off when speed is
lights (yellow) when the
L/A - Link/Activity LED
lights (green) when the
Ethernet cables are
connected and terminated
10 Mbps.
correctly.