Quick Start Guide
AXC-REL8 Universal Eight Relay Card
Devices that require a simple momentary or latching contact closure can be controlled with the AXC-REL8 Universal Eight Relay Card (FIG. 1). This card can operate up to 8 relay-controlled functions; cards can be linked together, allowing a larger number of functions. Adjacent relays on the card may be selectively commoned to reduce device wiring.
FIG. 1 AXC-REL8 Universal Eight Relay Card (side view)
The table below provides specification information for the AXC-REL8 (FG715).
Specifications
Power |
• 150 mA, 12 VDC |
Consumption: |
|
|
|
Contact |
• 8 per card |
Closures: |
|
|
|
Relays: |
• Single pole double throw (SPDT). |
|
• Each relay is individually assignable as normally open |
|
(NO) or normally closed (NC) via jumpers provided on the |
|
card. |
|
|
Jumpers: |
• JP1: Installed between center pin and NC, relay 1 is |
|
Normally Closed; installed between center pin and NO, |
|
relay 1 is Normally Open. |
|
• JP2: Same as JP1 for relays 2 - 8, respectively a jumper |
|
must be in one of these locations for each relay used. |
|
|
LEDs: |
• CR1 - 8: Indicates energized condition of corresponding |
|
relay |
|
|
Contact Rating: |
• 1 A @ 24 VAC / 28 VDC |
|
• 750 mA MAX resistive load. |
|
|
The table below lists the AXC-REL8 pinout connectors.
Pinout Connectors
Pinout |
Description |
|
|
|
|
1 |
Common #1 |
|
|
|
|
2 |
Contact #1 |
|
|
|
|
3 |
Common #2 |
|
|
|
|
4 |
Contact #2 |
|
|
|
|
5 |
Common #3 |
|
|
|
|
6 |
Contact #3 |
|
|
|
|
7 |
Common #4 |
|
|
|
|
8 |
Contact #4 |
|
|
|
|
9 |
Common #5 |
|
|
|
|
10 |
Contact #5 |
|
|
|
|
11 |
Common #6 |
|
|
|
|
12 |
Contact #6 |
|
|
|
|
13 |
Common #7 |
|
|
|
|
14 |
Contact #7 |
|
|
|
|
15 |
Common #8 |
|
|
|
|
16 |
Contact #8 |
|
|
|
|
The table below lists the commons for the AXC-REL8 if installed in the On position.
Commons
Commons |
Description |
|
|
CO1 - 2 |
Connects Common #1 to Common #2. |
|
|
CO2 - 3 |
Connects Common #2 to Common #3. |
|
|
CO3 - 4 |
Connects Common #3 to Common #4. |
|
|
CO4 - 5 |
Connects Common #4 to Common #5. |
|
|
CO5 - 6 |
Connects Common #5 to Common #6. |
|
|
CO6 - 7 |
Connects Common #6 to Common #7. |
|
|
CO7 - 8 |
Connects Common #7 to Common #8. |
|
|
The table below provides a description for the illumination of each relay LED. Refer to FIG. 2 for a visual reference of LED locations.
Relay Status LEDs
Relay LED # |
Description |
|
|
CR1 (top LED) |
Indicates the energized condition of relay 1. |
|
|
CR2 |
Indicates the energized condition of relay 2. |
|
|
CR3 |
Indicates the energized condition of relay 3. |
|
|
CR4 |
Indicates the energized condition of relay 4. |
|
|
CR5 |
Indicates the energized condition of relay 5. |
|
|
CR6 |
Indicates the energized condition of relay 6. |
|
|
CR7 |
Indicates the energized condition of relay 7. |
|
|
CR8 |
Indicates the energized condition of relay 8. |
|
|
|
|
Top LED
FIG. 2 AXC-REL8 Relay status locations