American Standard 2555.602 User Manual

0 (0)
American Standard 2555.602 User Manual

Installation

Instructions

T O W N S Q U A R E

2555.602

P R E S S U R E B A L A N C I N G B AT H A N D

S H O W E R - B u i l t - i n D i v e r t e r f o r T U B F I L L E R

Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years.

To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.

 

 

 

 

 

Certified to comply with ANSI A112.18.1

 

 

 

 

 

 

M968789 Rev. 1.5

Required Tools

ROUGHING-IN DIMENSIONS

 

 

 

 

 

To assure proper positioning in relation to wall, note

 

 

 

roughing-in dimensions.

 

 

 

 

 

FINISHED WALL

 

1-5/8" TO 3-1/4"

 

 

Phillips Screwdriver

 

 

 

 

 

1

 

 

 

 

 

 

 

1/2" I.P.S.

 

 

 

 

 

 

 

 

 

2" REF.

 

 

OPTIONAL TO

 

 

Flat Blade Screwdriver

 

 

 

 

 

 

 

 

FINISHED FLOOR

 

 

 

 

 

 

USUALLY BETWEEN

 

 

 

 

 

 

65'' AND 78''

 

 

 

 

8" REF.

 

 

 

OUTLETS 1/2" NPT

 

74" FOR

 

 

 

 

 

 

HEAD CLEARANCE

 

 

 

 

 

Plumbers' Putty or Caulking

 

 

SHW

"SEE ILLUSTRATION"

 

 

 

 

 

5-5/8"

 

7-1/2"

 

 

 

 

 

 

 

 

 

 

TUB

 

 

 

 

18"

 

 

 

 

 

 

OPTIONAL

 

 

 

 

1-3/4"

 

 

7-1/4" REF.

 

 

 

Channel Locks

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/2" COPPER

INLETS

5-5/8"

 

TOP OF

4"

1/2" NPT

THREADED INLETS (STOPS)

 

 

1-3/4" REF.

 

 

 

TUB RIM

 

 

 

 

 

Adjustable Wrench

BOTTOM OF

 

 

 

 

 

TUB

 

 

 

 

 

1

ROUGHING-IN

CAUTION

Turn off water at main supply.

 

 

 

 

 

 

NOTE

When soldering, remove PLASTER GUARD, CARTRIDGES and CHECK STOPS (IF PRESENT). When finished soldering,

5

 

 

flush valve body, replace cartridges, check stops (if present) and plaster guard to continue installation. Use thread

sealant or Teflon tape on threaded connections.

7

 

See Roughing-in diagram before starting. Connections are:

1/2" female NPT for threaded inlets Connect RISER PIPE (1) to MANIFOLD (2) top outlet marked "SHR".

Connect TUB FILLER PIPE (3) at bottom outlet marked "TUB".

For proper positioning the finished wall must be within side wall of PLASTER GUARD (4).

If the valve is installed on a fiberglass or other thin wall application, the

PLASTER GUARD (4) can be used as a support. Cut a 4" dia. hole in the shower stall.

Drill two additional 1" holes to allow access to the stops.

Remove PLASTER GUARD (4), rotate 180˚

so that indicated screw holes fit MANIFOLD (2). Push CAP on valve, place ESCUTCHEON on and

attach with screws.

Connect hot and cold water supplies.

1

2 COLD 4

HOT

3

Cap off shower pipe (5) and tub filler pipe (6).

6

For support, use pipe BRACES (7) secured to wooden braces.

 

With valve turned off, turn on water supplies. Check for leaks.

Loading...