Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets.
Speed Connect Drain*
•1/3 of the parts, installs in 1/3 of the time
•No tools needed
•Never needs adjustment
•Guaranteed to seal properly the first time, every time.
Certified to comply with ANSI A112.18.1
M968672 Rev . 1 . 1
*Your new American Standard faucet is designed to work only with the Speed Connect drain.
Heplful tips for removing your current drain can be found in the Troubleshooting section of these instructions.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Recommended tools
Screwdriver |
Channel Locks |
Adjustable Wrench |
Tubing Cutter |
1 |
|
|
Turn off hot and cold water |
|
INSTALL SPOUT |
CAUTION |
|||
|
supplies before beginning. |
|||
|
|
|
|
Insert SPOUT (1) and CABLE CONNECTOR (12) through center hole, making sure the SPOUT ESCUTCHEON (2) and SEAL WASHER (3) are properly seated.
Assemble RUBBER WASHER (4), BRASS WASHER (5) and LOCKNUT (6) onto SPOUT SHANK (7) from under side of sink . Make sure SPOUT (1) is centered in the mounting hole and the slot in the BRASS WASHER (5) faces toward the rear of the sink.
Tighten LOCKNUT (6) firmly. Fig. A.
Fig. A.
1
27
3
1A INSTALL VALVE BODY |
|
|
|
|
|
Place RUBBER RING (9) into ADAPTER (10). |
|
|
4 |
||
Install LOCKNUT (11) onto VALVE BODY (8). From under side of mounting |
|
||||
SLOT |
5 |
||||
surface, install VALVE BODY (8) through valve mounting holes. Threads of |
|||||
|
|||||
VALVE BODY (8) should extent at least 5/16 of a inch above mounting |
|
|
|||
surface top. Fig. B. Thread ADAPTER (10) onto VALVE BODY (8) until snug |
|
6 |
|||
against internal stop. If necessary, adjust LOCKNUT (11). |
|
||||
|
|
||||
Hand tighten LOCKNUT (11) to secure VALVE BODY (8). Repeat above |
|
12 |
|||
steps for opposite VALVE BODY (8A). |
|
1 |
|
||
|
|
|
|
||
10 |
|
10 |
|
|
|
9 |
MOUNTING |
9 |
|
|
|
5/16'' MIN. |
|
|
|||
SURFACE |
|
|
8a |
||
|
|
|
|
Fig. B.
11 8
8 11
1
2 INSTALL POP-UP DRAIN |
Fig. A. |
Fig. B. |
REAR OF |
|
|
|
|
Remove CLEAR PLASTIC COVER (1). Remove |
|
|
SINK |
1 |
|
|
|
CARDBOARD SPACER (2) from under DRAIN |
|
|
|
POP-UP (3). Fig. A. |
3 |
|
4 |
Drop DRAIN BODY (4) through sink drain |
|
||
|
|
6 |
|
hole. Make sure WHITE FOAM GASKET (5) |
|
|
|
|
|
5 |
|
is under flange of DRAIN BODY (4). Fig. B. |
|
|
|
|
|
|
|
Note: No plumber’s putty or caulk is required. |
2 |
|
SINK |
|
DRAIN |
||
The CABLE ATTACHMENT POINT (6) must |
|
|
HOLE |
|
|
|
|
face towards the rear of the SINK. Fig. B. |
|
|
|
3 INSTALL BLACK GASKET |
|
|
|
Install BLACK CONE GASKET (1) onto DRAIN BODY (2) |
|
|
|
from below. |
|
|
|
Note: The flat side of the BLACK CONE GASKET (1) must |
|
|
|
face down. |
|
2 |
|
|
|
|
|
1 |
|
|
|
|
FLAT SIDE OF GASKET |
|
|
|
|
MUST FACE DOWN |
4 INSTALL GRAY LOCKNUT |
Fig. A. |
|
Fig. B. |
|
|
Install GRAY LOCKNUT (1) onto DRAIN BODY (2) |
|
|
|
|
from below SINK. Fig. A. |
|
|
|
|
Note: The flat side of the GRAY LOCKNUT (1) |
|
|
|
|
must face up. |
|
2 |
|
|
Tighten firmly by hand. No tools are required. |
|
|
DRAIN |
|
Check DRAIN FLANGE in SINK to ensure that |
|
|
FLANGE |
|
WHITE FOAM GASKET (3) is fully compressed |
|
|
FLAT SIDE OF |
|
and not visible. Fig. B. |
|
|
GRAY LOCKNUT |
|
|
|
MUST FACE UP |
|
|
|
|
1 |
3 WHITE FOAM |
|
|
|
|
GASKET |
|
|
|
|
NOT VISIBLE |
5 |
POP-UP KNOB |
|
|
DOWN |
|
|
|
||
|
POP-UP KNOB (1) must be fully down. |
|
|
1 |
|
|
|
|
M968672 Rev . 1 . 1
2
6 ATTACH CABLE CONNECTOR |
Fig. A. |
Fig. B. |
Thread CABLE CONNECTOR (1) clockwise |
|
|
onto DRAIN BODY CONNECTION (2) and |
|
1 |
hand tighten. Fig. A. |
|
|
|
|
|
Your new POP-UP DRAIN installation is |
|
|
now complete. Fig. B. |
|
|
Note: Tailpeice on pop-up drain is 1-1/4” O.D. |
|
|
Fig. B. |
|
|
|
|
1-1/4” O.D. |
|
|
2 |
7 CHECK OPERATION OF POP-UP |
|
Operate LIFT KNOB (1) to verify that STOPPER (2) opens and |
1 |
|
|
closes. |
|
Note: If STOPPER (2) does not open and close properly then refer to the “troubleshooting section” of these instructions.
8 MAKE WATER SUPPLY AND WASTE CONNECTIONS
NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS NOT INCLUDED AND MUST BE PURCHASED SEPARATELY.
Thread TEE BODY (4) to SPOUT SHANK (5).
Thread HOSE CONNECTOR (6, 6A) to VALVE CONNECTIONS (7, 7A).
Connect water supply to VALVE BODIES (1,1A) with 1/2" IPS FLEXIBLE SUPPLIES (2) or 3/8" O.D. BULL-NOSE RISERS (3). Use
adjustable wrench to tighten connections. Do not over tighten.
Be careful not to kink copper supply when bending. Use tubing cutter to cut to proper length.
Connect HOT water supply to inlet of left SHANK and COLD water supply to right SHANK using sealant, appropriate connectors, and COUPLING NUTS.
Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to
waste outlet. |
1 |
|
|
|
|
1/2" PIPE THREAD |
|
|
|
|
|
|||
|
2 |
|
|
|
|
|
|
|
|
|
FLEXIBLE |
|||
|
SUPPLIES |
|
|
|
|
1A |
|
5 |
|
7A |
|
|
|
6A |
|
|
|
|
|
|
|
|
|
|
|
COUPLING |
|
|
|
|
NUT |
7 |
|
4 |
3 |
3/8 O.D. |
|
|
BULL-NOSE |
||
6 |
|
|
|
RISERS |
|
|
|
COMPRESSION |
|
|
|
|
NUT |
|
WASTE |
|
|
FERRULE |
|
OUTLET |
|
|
||
|
|
|
|
COLD
HOT
3/8 COMPRESSION CONNECTION
M968672 Rev . 1 . 1