American Standard 4508S User Manual

0 (0)

 

Installation

SYMPHONY

Instructions

4508

Spread Lavatory Faucet

with Speed Connect™ Drain

4508S

Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets.

Speed Connect Drain*

1/3 of the parts, installs in 1/3 of the time

No tools needed

Never needs adjustment

Guaranteed to seal properly the first time, every time.

Certified to comply with ANSI A112.18.1

M968672 Rev . 1 . 1

*Your new American Standard faucet is designed to work only with the Speed Connect drain.

Heplful tips for removing your current drain can be found in the Troubleshooting section of these instructions.

To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.

Recommended tools

Screwdriver

Channel Locks

Adjustable Wrench

Tubing Cutter

1

 

 

Turn off hot and cold water

INSTALL SPOUT

CAUTION

 

supplies before beginning.

 

 

 

 

Insert SPOUT (1) and CABLE CONNECTOR (12) through center hole, making sure the SPOUT ESCUTCHEON (2) and SEAL WASHER (3) are properly seated.

Assemble RUBBER WASHER (4), BRASS WASHER (5) and LOCKNUT (6) onto SPOUT SHANK (7) from under side of sink . Make sure SPOUT (1) is centered in the mounting hole and the slot in the BRASS WASHER (5) faces toward the rear of the sink.

Tighten LOCKNUT (6) firmly. Fig. A.

Fig. A.

1

27

3

1A INSTALL VALVE BODY

 

 

 

 

Place RUBBER RING (9) into ADAPTER (10).

 

 

4

Install LOCKNUT (11) onto VALVE BODY (8). From under side of mounting

 

SLOT

5

surface, install VALVE BODY (8) through valve mounting holes. Threads of

 

VALVE BODY (8) should extent at least 5/16 of a inch above mounting

 

 

surface top. Fig. B. Thread ADAPTER (10) onto VALVE BODY (8) until snug

 

6

against internal stop. If necessary, adjust LOCKNUT (11).

 

 

 

Hand tighten LOCKNUT (11) to secure VALVE BODY (8). Repeat above

 

12

steps for opposite VALVE BODY (8A).

 

1

 

 

 

 

 

10

 

10

 

 

9

MOUNTING

9

 

 

5/16'' MIN.

 

 

SURFACE

 

 

8a

 

 

 

 

Fig. B.

11 8

8 11

1

American Standard 4508S User Manual

2 INSTALL POP-UP DRAIN

Fig. A.

Fig. B.

REAR OF

 

 

 

Remove CLEAR PLASTIC COVER (1). Remove

 

 

SINK

1

 

 

CARDBOARD SPACER (2) from under DRAIN

 

 

POP-UP (3). Fig. A.

3

 

4

Drop DRAIN BODY (4) through sink drain

 

 

 

6

hole. Make sure WHITE FOAM GASKET (5)

 

 

 

 

5

is under flange of DRAIN BODY (4). Fig. B.

 

 

 

 

 

Note: No plumber’s putty or caulk is required.

2

 

SINK

 

DRAIN

The CABLE ATTACHMENT POINT (6) must

 

 

HOLE

 

 

 

face towards the rear of the SINK. Fig. B.

 

 

 

3 INSTALL BLACK GASKET

 

 

 

Install BLACK CONE GASKET (1) onto DRAIN BODY (2)

 

 

from below.

 

 

 

Note: The flat side of the BLACK CONE GASKET (1) must

 

 

face down.

 

2

 

 

 

 

 

1

 

 

 

 

FLAT SIDE OF GASKET

 

 

 

 

MUST FACE DOWN

4 INSTALL GRAY LOCKNUT

Fig. A.

 

Fig. B.

 

Install GRAY LOCKNUT (1) onto DRAIN BODY (2)

 

 

 

 

from below SINK. Fig. A.

 

 

 

 

Note: The flat side of the GRAY LOCKNUT (1)

 

 

 

 

must face up.

 

2

 

 

Tighten firmly by hand. No tools are required.

 

 

DRAIN

 

Check DRAIN FLANGE in SINK to ensure that

 

 

FLANGE

 

WHITE FOAM GASKET (3) is fully compressed

 

 

FLAT SIDE OF

 

and not visible. Fig. B.

 

 

GRAY LOCKNUT

 

 

 

MUST FACE UP

 

 

 

1

3 WHITE FOAM

 

 

 

 

GASKET

 

 

 

 

NOT VISIBLE

5

POP-UP KNOB

 

 

DOWN

 

 

 

 

POP-UP KNOB (1) must be fully down.

 

 

1

 

 

 

 

M968672 Rev . 1 . 1

2

6 ATTACH CABLE CONNECTOR

Fig. A.

Fig. B.

Thread CABLE CONNECTOR (1) clockwise

 

 

onto DRAIN BODY CONNECTION (2) and

 

1

hand tighten. Fig. A.

 

 

 

Your new POP-UP DRAIN installation is

 

 

now complete. Fig. B.

 

 

Note: Tailpeice on pop-up drain is 1-1/4” O.D.

 

 

Fig. B.

 

 

 

 

1-1/4” O.D.

 

 

2

7 CHECK OPERATION OF POP-UP

 

Operate LIFT KNOB (1) to verify that STOPPER (2) opens and

1

 

closes.

 

Note: If STOPPER (2) does not open and close properly then refer to the “troubleshooting section” of these instructions.

8 MAKE WATER SUPPLY AND WASTE CONNECTIONS

NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS NOT INCLUDED AND MUST BE PURCHASED SEPARATELY.

Thread TEE BODY (4) to SPOUT SHANK (5).

Thread HOSE CONNECTOR (6, 6A) to VALVE CONNECTIONS (7, 7A).

Connect water supply to VALVE BODIES (1,1A) with 1/2" IPS FLEXIBLE SUPPLIES (2) or 3/8" O.D. BULL-NOSE RISERS (3). Use

adjustable wrench to tighten connections. Do not over tighten.

Be careful not to kink copper supply when bending. Use tubing cutter to cut to proper length.

Connect HOT water supply to inlet of left SHANK and COLD water supply to right SHANK using sealant, appropriate connectors, and COUPLING NUTS.

Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to

waste outlet.

1

 

 

 

 

1/2" PIPE THREAD

 

 

 

 

 

2

 

 

 

 

 

 

 

 

FLEXIBLE

 

SUPPLIES

 

 

 

 

1A

 

5

 

7A

 

 

6A

 

 

 

 

 

 

 

 

 

COUPLING

 

 

 

 

NUT

7

 

4

3

3/8 O.D.

 

 

BULL-NOSE

6

 

 

 

RISERS

 

 

 

COMPRESSION

 

 

 

NUT

WASTE

 

 

FERRULE

OUTLET

 

 

 

 

 

 

COLD

HOT

3/8 COMPRESSION CONNECTION

M968672 Rev . 1 . 1

3