Installation
Instructions
3821.631 SERIES 3821.641 SERIES
3821.634 SERIES
SINGLE CONTROL KITCHEN 3821.644 SERIES FAUCET WITH CAST SPOUT
Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.
Certified to comply with ANSI A112.18.1M
M 9 6 8 1 8 8 E
TOOLS REQUIRED
|
|
Phillips Screwdriver |
|
|
|
|
Adjustable Wrench |
Plumbers' Putty or Caulking |
|
|
Channel Locks |
Regular Screwdriver |
Tubing Cutter |
|
|
|
|
|
|
1 |
INSTALL FAUCET WITH OR WITHOUT DECK ESCUTCHEON |
|
|
|
CAUTION Turn off hot and cold water supplies before beginning. |
|
|
(A) Installation with ESCUTCHEON (1). Apply a bead of putty to bottom edge of ESCUTCHEON (1). Insert supply TUBES (3) and SHANK (4) through hole of ESCUTCHEON (1) and mounting surface. Make certain the O-RING (2)
is properly seated in recess of SPOUT BASE. Follow mounting instructions below to secure faucet to mounting surface.
(B) Installation less ESCUTCHEON (1). Remove ESCUTCHEON (1) , feed FAUCET TUBES (3) and SHANK (4) through DECORATIVE FLANGE (10). Push FLANGE so the raised step fits into recess of SPOUT BASE.
Push O-RINGS (2) onto SPOUT SHANK. Make certain the O-RING (2) is properly seated in recess of DECORATIVE FLANGE (10).
Insert SUPPLY TUBES (3) and SHANK (4) through mounting hole and seat DECORATIVE FLANGE (10) onto sink or mounting surface.
Assemble RUBBER WASHER (5), BRASS WASHER (6), and threaded LOCKNUT (7) onto SHANK (4) from underside of sink or mounting surface. Hand tighten LOCKNUT (7) and check that rotation of HANDLE (8) from HOT to COLD is centered.
Use a screwdriver to tighten SCREWS (9) on LOCKNUT (7). Work your way around LOCKNUT (7), tightening the screws slightly each time until all are snug to ensure even pressure.
|
A |
|
B |
|
8 |
|
8 |
|
|
|
|
SPOU T BASE |
|
SPOU T BASE |
|
|
2 |
|
10 |
|
|
|
|
1 |
|
|
2 |
|
|
|
4 |
|
|
4 |
|
P U T T Y |
3 |
SIN K OR |
3 |
|
MOUNTING |
|
|
|
|
|
SURFACE
5 |
5 |
6 |
6 |
7 |
7 |
9 |
9 |
2 MAKE WATER SUPPLY CONNECTIONS
NOTE: FLEXIBLE SUPPLIES HAVE TO BE PURCHASED SEPARATELY
Carefully bend COPPER SUPPLIES to meet water supply lines using the palms of the hands to avoid kinking.
Connect HOT water supply line to left tube, and COLD water supply line to right tube using appropriate connectors.
Use 1/2" IPS FLEXIBLE SUPPLIES (3) or 3/8" O.D. BULL-NOSE RISERS (4). Use adjustable wrench to tighten connections. Do not over tighten. Be careful not to kink copper supply when bending. Use tubing cutter to cut to proper length.
COPPER SUPPLIES TUBES
FERRULE
HOT
3 4
COLD
3 INSTALL SPRAY HOLDER
On model with separate spray, place the SPRAY HOLDER (1) into the appropriate mounting hole. Assemble the SPRAY HOLDER WING NUT (2) onto the shank of SPRAY HOLDER (1) from below and tighten. Do not use putty.
On model with spray through the ESCUTCHEON (3), place |
|
SPRAY HOLDER (4) into the hole of ESCUTCHEON (3). Assemble |
1 |
SPRAY HOLDER NUT (5) onto the shank of SPRAY HOLDER (4) |
|
from below and tighten. Do not use putty. |
|
For installation less spray cap off SPRAY HOSE CONNECTION with PIPE CAP (6).
SPRAY HOSE
CONNECTION
4 |
3 |
2 |
|
|
|
5 |
6 |
|
4 CONNECT HOSE SPRAY
Feed SPRAY HOSE (1) through SPRAY HOLDER (2) and attach COUPLING NUT (3) of HOSE (1) to HOSE ADAPTOR (4) on valve
body. Tighten COUPLING NUT (3) firmly.
1
2
4
3
M 9 6 8 1 8 8 E