American Standard 7415.801, 7420.801, 7415.821, 7420.821 User Manual

0 (0)

Installation

Instructions

PORTSMOUTH™

7420.801

Spread Lavatory Faucet

7420.821

with Speed Connect™ Drain

Series

Congratulations on purchasing your

American Standard faucet with

7415.801

Speed Connect drain, a feature found

onlyon American Standard faucets.

7415.821

Speed Connect Drain*

Series

• Fewer parts, installs in less time

 

• Never needs adjustment

• Guaranteed to seal properly the first time, every time.

74 2 0

74 15

Certified to comply with ANSI A112.18.1

M965015 REV. 1. 7

*Your new American Standard faucet is designed to work only with the Speed Connect drain.

Heplful tips for removing your current drain can be found in the Troubleshooting section of these instructions.

To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.

Recommended tools

Screwdriver

Channel Locks

Adjustable Wrench

Tubing Cutter

1

 

 

Turn off hot and cold water

 

INSTALL SPOUT

CAUTION

 

supplies before beginning.

 

 

 

 

Insert SPOUT (1) and CABLE CONNECTOR (12) through center hole, making sure the SEAL WASHER (3) is properly seated in the SPOUT ESCUTCHEON (2).

Assemble RUBBER WASHER (4), BRASS WASHER (5) and LOCKNUT (6) onto SPOUT SHANK (7) from under side of sink . Make sure SPOUT (1) is centered in the mounting hole and the slot in the BRASS WASHER (5) faces toward the rear of the sink.

Tighten LOCKNUT (6) firmly. Fig. A.

Fig. A.

1

2

7 3

1A INSTALL VALVE BODY

Place RUBBER RING (9) into ADAPTER (10).

Install LOCKNUT (11) onto VALVE BODY (8).

From under side of mounting surface, install VALVE BODY (8) through valve mounting holes. Threads of VALVE BODY (8) should extent at least 5/16 of a inch above mounting surface top. Fig. B. Thread ADAPTER (10)

onto VALVE BODY (8) until snug against internal stop. If necessary, adjust LOCKNUT (11).

Hand tighten LOCKNUT (11) to secure VALVE BODY (8).

1

Repeat above steps for opposite VALVE BODY (8A).

SLOT

5

6

12

10

9

5/16'' MIN.

MOUNTING

SURFACE

Fig. B.

10

9

8A

11 8

8 11

1

American Standard 7415.801, 7420.801, 7415.821, 7420.821 User Manual

2 POP-UP DRAIN

Fig. A.

Fig. B.

Remove CLEAR PLASTIC COVER (1).

1

 

Remove CARDBOARD SPACER (2) from under

3

DRAIN

DRAIN POP-UP (3).

BODY

Tighten TAILPIECE (4) on DRAIN BODY before

 

 

installing DRAIN BODY. Fig. B.

 

 

 

2

4

 

 

3 REMOVE FLANGE

Fig. A

 

Fig. B.

Thread FLANGE (1) counter-clockwise and remove

1

 

 

 

 

 

FLANGE (1) and FOAM GASKET (2) from drain

 

 

 

body. Fig. A.

 

 

 

Thread LOCKNUT (3) clock-wise to bottom of

 

 

 

drain body. Push GASKET (4) down against

 

 

4

LOCKNUT (3). Fig. B.

 

2

 

 

 

3

4

INSTALL DRAIN FROM

 

REAR OF SINK

5 TIGHTEN LOCKNUT

BELOW FIXTURE

 

 

From under side of SINK

4

 

Tighten LOCKNUT (1) firmly with Adjustable

 

install DRAIN BODY (1) up

 

Wrench or Channel Locks.

 

through drain outlet.

 

 

 

 

Note: No plumber’s putty

3

 

 

 

or caulk is required.

 

 

 

The CABLE ATTACHMENT

 

 

 

 

POINT (2) must face towards

 

 

 

 

the rear of the SINK.

 

1

1

 

Install FOAM GASKET (3) and

 

 

 

2

 

 

FLANGE (4) onto drain body

 

 

 

from above SINK and tighten

 

 

 

 

FLANGE (4) firmly.

 

 

 

6 FLANGE GASKET AND POP-UP KNOB

Fig. A.

Fig. B. DOWN

 

Check DRAIN FLANGE in SINK to ensure that

 

1

 

 

 

 

WHITE FOAM GASKET (3) is fully compressed

 

 

 

and not visible. Fig. A.

 

 

 

 

POP-UP KNOB (1) must be fully down. Fig. B.

WHITE FOAM

 

 

GASKET

 

 

 

 

NOT VISIBLE

DRAIN

 

 

 

 

FLANGE

 

 

 

 

M965015 REV. 1. 7

2

7 ATTACH CABLE CONNECTOR

Fig. A.

Fig. B.

Thread CABLE CONNECTOR (1) clockwise

 

 

onto DRAIN BODY CONNECTION (2) and

 

1

hand tighten. Fig. A.

 

 

 

Your new POP-UP DRAIN installation is

 

 

now complete. Fig. B.

 

 

Note: Tailpeice on pop-up drain is 1-1/4” O.D.

 

 

Fig. B.

 

 

 

 

2

1-1/4” O.D.

8 CHECK OPERATION OF POP-UP

 

Operate LIFT KNOB (1) to verify that STOPPER (2) opens and

1

closes.

 

Note: If STOPPER (2) does not open and close properly then refer

 

to the “troubleshooting section” of these instructions.

 

9 MAKE WATER SUPPLY AND WASTE CONNECTIONS

NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS NOT INCLUDED AND MUST BE PURCHASED SEPARATELY.

Thread TEE BODY (4) to SPOUT SHANK (5).

Thread HOSE CONNECTOR (6, 6A) to VALVE CONNECTIONS (7, 7A).

Connect water supply to VALVE BODIES (1,1A) with 1/2" IPS FLEXIBLE SUPPLIES (2) or 3/8" O.D. BULL-NOSE RISERS (3). Use

adjustable wrench to tighten connections. Do not over tighten. Be careful not to kink copper supply when bending. Use tubing

cutter to cut to proper length.

Connect HOT water supply to inlet of left SHANK and COLD water supply to right SHANK using sealant, appropriate connectors, and COUPLING NUTS.

Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to

1

 

waste outlet.

 

7

 

 

 

 

1/2" PIPE THREAD

6

 

 

2

WASTE

 

 

OUTLET

FLEXIBLE

SUPPLIES

HOT

 

5

1A

 

 

 

 

7A

 

 

6A

 

 

COUPLING

 

 

NUT

4

 

3/83O.D.

 

BULL-NOSE

 

 

RISERS

 

 

COMPRESSION

 

 

NUT

 

 

FERRULE

COLD

3/8 COMPRESSION

 

CONNECTION

M965015 REV. 1. 7

 

3

Loading...
+ 5 hidden pages