American Standard 6063.051, 6063.101, 6063.510, 6063.505 User Manual

Installation Instructions
SELECTRONIC™ PROXIMITY URINAL FLUSH VALVE
0.5 & 1.0 GPF
MODEL NUMBERS
6063.510
6063.505
Exposed Flushometer for 3/4" Top Spud Urinals
CLOG RESISTANT
• Self-cleaning piston valve prevents clogging and reduces maintenance.
ONE SENSOR FITS ALL
• Only 1 sensor for entire Selectronic™ line of faucets, urinals, and ush valves.
• Range can be adjusted manually or with optional remote control.
• Sensor Features Low Battery Indicator.
6063.051
6063.101
Certified to comply with ASME A112.19.2M
© 2008 AS America, Inc.
Installation Instructions
NOTE TO INSTALLER: Please give this manual to the customer after installation.
To learn more about American Standard Faucets visit our website at: www.americanstandard-us.com or U.S. customer's e-mail us at: faucetsupport@americanstandard.com
For Parts, Service, Warranty or other Assistance, please call
M968567 Rev. 1.2
1-800-442-1902 (In Canada: 1-800-387-0369)
(In Toronto Area only: 1-905-3061093)
(In Toronto Area only: 1-905-3061093)
Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that
Installation Instructions
your installation proceeds smoothly--please read these instructions carefully before you begin.
UNPACKING
All American Standard Products Are Water Tested At Our Factory. Some Residual Water May Remain In The Valve During Shipping.
1. Remove the Flush Valve items from the carton. The illustration below shows all items after they have been removed from the carton. Some items may be packaged partially assembled to other items.
1. Flush Valve Assembly
2. Down Tube and Vacuum Breaker
3. Spud Coupling Nut and Washers
4. Spud Flange
5. Sweat Solder Adapter
6. Cover Tube
7. Wall Escutcheon
8. Supply Stop
9. Installation Instructions
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.
DO NOT REMOVE PROTECTIVE FILM FROM SENSOR EYE UNTIL INSTALLATION IS COMPLETE.
6
5
7
8
1
2
3
4
9
SELECTRONIC™ PROXIMITY URINAL FLUSH VALVE
0.5 & 1.0 GPF
MODEL NUMBERS
6063.510
6063.051
6063.505
6063.101
Exposed Flushometer for 3/4" Top Spud Urinals
CLOG RESISTANT
• Self-cleaning piston valve prevents clogging and reduces maintenance.
ONE SENSOR FITS ALL
• Only 1 sensor for entire Selectronic™ line of faucets, urinals, and ush valves.
• Range can be adjusted manually or with optional remote control.
• Sensor Features Low Battery Indicator.
Certified to comply with ASME A112.19.2M
© 2008 AS America, Inc.
Installation Instructions
M968567 Rev. 1.2
NOTE TO INSTALLER: Please give this manual to the customer after installation.
To learn more about American Standard Faucets visit our website at: www.americanstandard-us.com or U.S. customer's e-mail us at: faucetsupport@americanstandard.com
For Parts, Service, Warranty or other Assistance, please call
1-800-442-1902 (In Canada: 1-800-387-0369)
(In Toronto Area only: 1-905-3061093)
(In Toronto Area only: 1-905-3061093)
1
M968567 Rev.1.2
Fig. 1
Roughing-in Dimensions
72mm
(2-7/8)
116mm (4-5/8)
MANUAL
OVERRIDE
293mm
(11-1/2)
BUTTON
115mm-134mm (4-1/2 TO 5-1/4)
FOR 3/4" TOP SPUD FIXTURES
SUPPLY DN 19mm (3/4” I.P.S.)
409mm
(16-1/8)
DETECTION ZONE
400mm-800mm
(15-3/4 TO 31-1/2)
FINISHED WALL
57mm (2-1/4 MIN.)
GENERAL DESCRIPTION:
SELECTRONIC™ PROXIMITY URINAL FLUSH VALVE
Exposed Flushometer for 3/4" Top Spud Fixtures
Exclusive, self cleaning piston-type flush valve with proximity operation and manual override. Operates on DC (battery) power. Recommended
15˚
operating pressure 35 to 80 psi. Can install left or right-handed. Detection Zone can also be adjusted manually, or with optional remote control.
Right or Left Hand Installation
See
(Section 5) for converting Flush
Valve to Left Hand Installation.
RECOMMENDED TOOLS; Fig. 2
1.
Teflon Tape
2.
Flat Blade Screwdriver (For adjusting Supply Stop)
3.
Adjustable Wrench
4.
Tape Measure
5.
Hacksaw
6.
Tubing Cutter
7.
File
8.
For Sweat Connection; Solder and Torch
9.
2.5mm Hex Wrench
10.
1.5mm Hex Wrench
PRIOR TO INSTALLATION
Note: Prior to installing the Selectronic™Flush Valve
the following items must be installed.
1. Urinal
2. Drain line
3. Water supply line
IMPORTANT:
• All plumbing must be installed in accordance with applicable codes and regulations.
• Water supply lines must be sized to provide an adequate volume of water for each fixture.
Fig. 2
1
2
4
10'
3
6
5
8
7910
• Flush all water lines prior to operation (See Step 4). Dirt and debris can cause flush valve to run continuously.
• With the exception of Supply Stop Inlet, DO NOT use pipe sealant or plumbing grease on any valve component or coupling!
• Protect the chrome or special finish on the Flushometer. DO NOT USE toothed tools on finished surfaces to install or service these valves. Also see “Care and Cleaning” section of this manual.
• This product contains mechanical and/or electrical components that are subject to normal wear. These components should be checked on a regular basis and replaced as needed to maintain the valve’s performance.
2
M968567 Rev.1.2
Loading...