American Standard 2460.XXXW, 2461.XXXW User Manual

0 (0)

CAMBRIDGE™

AMERICAST BRAND ENGINEERED MATERIAL

2460.XXXW SERIES 2461.XXXW SERIES WHIRLPOOL/BATHING POOL

INSTALLATION INSTRUCTIONS

 

 

 

 

1524mm

 

 

 

 

 

 

203mm

(60)

 

 

 

 

19mm

 

 

70mm

 

 

 

 

(8)

FINISHED

 

 

 

 

(2-3/4)

 

 

 

(3/4)

 

 

WALL

 

SERVICING ON ALL INSTALLATIONS

 

 

 

 

PROVIDE ACCESS TO PUMP FOR

406mm

102mm

 

 

PUMP

(16)

 

 

(4)

 

 

 

 

 

 

 

 

 

 

 

 

229mm x 305mm

 

 

 

 

 

(9 x 12)

 

 

102mm

 

 

FLOOR

 

 

 

 

CUTOUT

 

 

(4)

 

 

 

813mm

 

 

 

ON / OFF

 

 

 

 

(32)

 

 

 

 

SWITCH

 

 

 

 

 

 

60mm+13mm

 

 

 

 

 

 

 

 

 

 

(2-3/8)+(1/2)

 

 

 

 

 

 

 

 

25mm

64mm

 

 

 

C/L OF 1/2

 

(1)

(2-1/2)

 

 

 

 

C/L OF

 

 

 

 

SUPPLIES

 

 

 

 

 

 

DRAIN

 

 

 

 

AS REQ'D

 

 

 

 

 

 

 

 

 

 

 

SHOWER ARM- 1/2 N.P.T.

32mm(1-1/4) DIA. HOLE

C/L OF CURTAIN ROD

 

711mm

USUALLY 1930mm(76) FROM

 

 

 

 

 

 

 

(28)

FINISHED FLOOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FINISHED

 

C/L OF

(2) 54mm(2-1/8)

 

102mm

 

WALL

 

VALVES

 

(4)

 

 

 

 

DIA. HOLES

 

 

 

 

OPTIONAL

 

 

102mm

SPOUT-

 

 

TO FLOOR

 

102mm

 

 

406mm

 

(4)

1/2 N.P.T.

 

SAFE-T-HEATER

USUALLY

(4)

 

 

(16)

 

 

76mm

 

BETWEEN

 

 

 

 

REMOVABLE BLANK

1651 & 1981mm

 

 

 

 

(3)

 

 

(65 & 78)

24mm

 

 

 

 

 

 

 

 

 

 

 

 

(15/16)

 

 

 

 

SEE

441mm

 

451mm

 

 

 

 

 

 

 

 

 

NOTE

 

 

 

 

 

(17-3/8)

 

(17-3/4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

70mm

 

 

 

 

 

 

 

 

 

 

 

 

(2-3/4)

 

 

 

 

 

 

 

ROUGH

 

 

117mm

 

 

 

 

FLOOR

 

 

 

 

1-1/2 N.P.T. THREADS

 

 

(4-5/8)

 

 

 

 

 

 

1-1/2 O.D. TAILPIECE

 

 

 

 

 

THANK YOU...

for selecting an American Standard bath. Your new bath is shipped to you after careful inspection. The whirlpool version is completely assembled with pump, motor, and system piping. All you need to finish the installation are your selected fittings and electrical connections for a whirlpool.

To insure maximum performance and pleasure from this product, please follow the instructions and cautions.

List of Optional Components (not included):

• Safe-T-Heater 9075.120*

* see your American Standard Distributor

List of Required Components (not included):

Drain 1583.470*

Bath Filler*

* see your American Standard Distributor

GENERAL SPECIFICATIONS FOR 2460/2461 WHIRLPOOL

INSTALLED SIZE

 

 

 

 

60 x 32 x 17-3/4 In. (1524 x 813 x 451mm)

 

 

 

WEIGHT

 

 

 

 

 

 

 

 

 

190 Lbs. (86 Kg.)

WEIGHT w/WATER

 

 

 

 

 

 

607 Lbs. (273 Kg.)

GAL. TO OVERFLOW

 

 

 

 

 

 

 

 

 

 

50 Gal. (190 L)

WHIRLPOOL MIN. OPERATING VOL.

 

 

 

 

 

39 Gal. (148 L)

 

 

 

 

 

BATHING WELL AT SUMP

 

 

 

 

41 x 20 In. (1041 x 508mm)

 

 

 

 

BATHING WELL AT RIM

 

 

 

 

 

54 x 26 In. (1372 x 660mm)

 

 

 

 

 

WATER DEPTH TO OVERFLOW

 

 

 

 

 

 

14 In. (356mm)

 

 

 

 

 

 

FLOOR LOADING

 

 

 

 

46 Lbs./Sq.Ft. (220 Kgs./Sq.m)

 

 

 

 

(PROJECTED AREA)

 

 

 

 

 

 

 

 

 

 

PTS.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CUBE (FT3)

 

 

 

 

31.5

 

 

 

 

 

 

 

WHIRLPOOL ELECTRICAL SPECIFICATIONS

SYSTEM I PUMP

 

 

 

 

1.6 HP, 9.7 AMPS,120V.

SAFETY HEATER

 

 

 

 

 

 

12 AMPS, 120V.

GENERAL INSTALLATION INFORMATION

List of Required Tools and Supplies:

Tools

Supplies

Level

Nails

Tape Measure

Putty

Pipe Wrench

Caulking (waterproof)

Slip Joint Pliers

1 x 3 or 2 x 4

Screw Driver

 

Stringers

Standard

Drop Cloth

 

Woodworking Tools

15 amp GFCI

Personal Safety

 

Outlet

 

Equipment

Cement, Plaster,

Caulking Gun

 

Grout

Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor immediately.

After inspection and during installation, protect the bath from construction damage. After installation, and before enclosing with wallboard, tile, etc., water test the unit and check for leaks.

Do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump, motor, or piping system.

Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead (required for recess installations).

Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.

WARNING! Do not lift whirlpool by the piping harness at any time.

FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.

© American Standard Inc. 2003

791033-100 Rev. I All product names listed herein are trademarks

of American Standard Inc. unless otherwise noted.

American Standard 2460.XXXW, 2461.XXXW User Manual

FRAMING AND INSTALLATION

BATH MAY ONLY BE INSTALLED ABOVE THE FLOOR LINE IN A RECESS TYPE INSTALLATION, AS SHOWN IN RECESS INSTALLATION DIAGRAM.

LOCATE STUDS AS REQUIRED. INSURE ROUGH DIMENSIONS ARE PROPER, PLUMB AND SQUARE. FOR WHIRLPOOLS, PROVISION MUST

BE MADE IN ALL INSTALLATIONS FOR AN ACCESS OPENING FOR SERVICING PUMP AND CONTROLS.

THE FOLLOWING PROCEDURE MUST BE USED FOR ALL INSTALLATIONS: LEVELING SUPPORT STRINGER SHOULD BE AS INDICATED. THE BATH IS SUPPORTED FROM THE APRON AND THE REAR TILING FLANGE. NO SUPPORT UNDER THE SUMP IS NECESSARY.

POSITION BATHTUB/WHIRLPOOL WITHIN THE RECESS, CHECK LEVEL, FRONT TO BACK, SIDE TO SIDE, AND SHIM AS NECESSARY. ALSO CHECK DRAIN CLEARANCE HOLE IN THE SUBFLOOR.

TO SECURE THE TUB TO WOOD STUDS USE ROOFING NAILS IMMEDIATELY ABOVE THE FLANGE OF THE TUB. TO SECURE THE TUB TO STEEL STUDS USE DRYWALL SCREWS AND FLATWASHERS.

CAUTION: TAKE EXTRA CARE WHEN DRIVING NAILS OR SCREWS TO AVOID DAMAGING THE TUB.

THE TILE OR SIMILAR FINISHED FLOOR WILL BE BUTTED AGAINST THE BOTTOM OF THE TUB APRON, ALSO HOLDING THE TUB IN PLACE.

TYPICAL RECESS INSTALLATION

441mm (17-3/8)

1527mm (60-1/8)

 

 

 

 

m

 

 

 

m

 

3

 

1

 

 

)

8

 

 

 

 

 

 

2

 

 

3

WIDTH

 

(

 

 

TUB

 

229 X 305mm (9 X 12) FLOOR CUTOUT

305mm

(12)

610 mm

(24)

WHIRLPOOL ONLY:

UNLESS AN ACCESS OPENING OF AT LEAST

12" X 24" (305 X 610MM) IS PROVIDED,

WARRANTY SERVICE WILL NOT BE PERFORMED.

SUGGESTED WHIRLPOOL/BATH INSTALLATION METHOD

WOOD STUDS

STUD

SHIM

DRY WALL

TILE

ROOFING NAIL

SEALANT

TUB

51 x 102mm (2 x 4) WOOD

STRINGER FULL LENGTH

STEEL STUDS

STEEL

STUD

SHIM

WASHER

DRY WALL

TILE

SEALANT

4" (102mm) DRYWALL

SCREW

TUB

51 x 102mm (2 x 4) WOOD

STRINGER FULL LENGTH

SECURE THE BATH TO THE STUDS

AS SHOWN FOR WOOD OR STEEL STUD

CONSTRUCTION.

791033-100 Rev. I

(2)

ELECTRICAL INSTALLATION INSTRUCTIONS

All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes.

WARNING:

When using electrical products, basic precautions should always be observed, including the following:

1.DANGER: RISK OF ELECTRIC SHOCK

Connect only to a circuit protected by a ground-fault circuit interrupter.

2.Grounding is required. The unit should be installed by a licensed electrician and grounded.

3.Install to permit access for servicing.

4.All building materials and wiring should be routed away from the pump body and heater (if equipped).

The whirlpool should be installed on a 120 vac, 15 amp dedicated circuit. The circuit should be hard-wired from the electrical power supply panel. The circuit must be a three (3) wire circuit from the electrical supply panel. A grounded neutral wire and a third wire, earth ground, are essential. ADDING THE SAFE-T-HEATER REQUIRES A SEPARATE

15 AMP MAXIMUM GFCI CIRCUIT.

ELECTRICAL INSTALLATION

 

SEPARATE 15 AMP

 

GFCI OUTLET

 

120 VAC

 

WHIRLPOOL MOUNTED

 

AIR SWITCH or

 

WALL TIMER

WHITE

BLACK

 

PUMP/MOTOR

 

GND.

ELECTRICAL DIAGRAM

READ AND FOLLOW ALL INSTRUCTIONS

791033-100 Rev. I

(3)

WIRE SELECTION GUIDE

 

 

 

 

 

 

 

 

 

 

 

Maximum distance from

The sizes shown on this

 

 

fusebox to motor

 

Motor

 

 

 

 

 

chart are recommendations

50'

100'

150'

 

200'

Hi-Performance

 

for copper conductors

Rating

 

 

 

 

 

only. Always follow

 

120V Power Line

 

 

 

 

local and national

1.6

12

12

10

 

8

electrical codes

 

 

 

 

 

 

 

 

 

DRAIN CONNECTION AND SYSTEM TEST

Using recommended drain opening, connect whirlpool drain to waste line. Tighten all drain joints securely. Check the pump couplings and make sure they are hand-tight. Clean the whirlpool and fill with water to a point 2" above the top of the highest jet. Recheck the pump couplings and make certain that they are not leaking. (Although the pump couplings are factory tightened and inspected, some loosening may have occured during transit.) Make sure the whirlpool is connected to the electrical supply and turn the whirlpool on. Check for leaks around all piping connections while the whirlpool is running.

POST INSTALLATION CLEAN-UP

Remove all construction debris from bath. Tile grout can be removed with a wooden popsicle stick or tongue depressor. Do not use wire brushes or any other metal implement on bath surface.

Post installation clean-up generally can be completed using warm water and liquid dishwashing detergent. Stubborn dirt or stains may be removed using granular Spic and Span® mixed with water.

Painter's naphtha can be used to remove excess adhesives and/or wet oil-base paint.

HARSH CHEMICALS SHOULD NEVER BE USED ON ENAMEL SURFACES.

Abrasive cleaners must not be used since they will scratch and dull the surface. Dulled areas can be restored by rubbing with a white automotive-type polishing compound and waxing with a liquid wax.

791033-100 Rev. I

(4)

SPIC AND SPAN

®

IS A REGISTERED TRADEMARK OF PROCTER & GAMBLE

 

 