American Standard 6063.051, 6063.101, 6063.510, 6063.505 User Manual

0 (0)

Installation Instructions

SELECTRONIC™

PROXIMITY URINAL FLUSH VALVE 0.5 & 1.0 GPF

MODEL NUMBERS

6063.510 6063.051

6063.505 6063.101

Exposed Flushometer for 3/4" Top Spud Urinals

CLOG RESISTANT

• Self-cleaning piston valve prevents clogging and reduces maintenance.

ONE SENSOR FITS ALL

Only 1 sensor for entire Selectronic™ line of faucets, urinals, and flush valves.

Range can be adjusted manually or with optional remote control.

Sensor Features Low Battery Indicator.

Certified to comply with ASME A112.19.2M

© 2008 AS America, Inc.

M968567 Rev. 1.2

NOTE TO INSTALLER: Please give this manual to the customer after installation.

To learn more about American Standard Faucets visit our website at: www.americanstandard-us.com or U.S. customer's e-mail us at: faucetsupport@americanstandard.com

For Parts, Service, Warranty or other Assistance,

please call 1-800-442-1902 (In Canada: 1-800-387-0369)

(In Toronto Area onlly:: 1--905--3061093))

American Standard 6063.051, 6063.101, 6063.510, 6063.505 User Manual

Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.

UNPACKING All American Standard Products Are Water Tested At Our Factory. Some Residual Water May Remain In The Valve During Shipping.

1. Remove the Flush Valve items from the carton. The illustration below shows all items after they have been removed from the carton. Some items may be packaged partially assembled to other items.

1.

Flush Valve Assembly

5.

Sweat Solder Adapter

2. Down Tube and Vacuum Breaker

6. Cover Tube

3.

Spud Coupling Nut and Washers

7.

Wall Escutcheon

4.

Spud Flange

8.

Supply Stop

 

 

9.

Installation Instructions

CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.

DO NOT REMOVE PROTECTIVE FILM FROM SENSOR

EYE UNTIL INSTALLATION IS COMPLETE.

6

5

8

7 1

 

 

Instructions

Exposed Flushometer

 

 

 

 

SELECTRONIC™

 

 

 

 

PROXIMITY URINAL FLUSH VALVE

 

 

 

 

0.5 & 1.0 GPF

 

 

 

 

MODEL NUMBERS

 

 

 

6063.510

6063.051

 

 

 

6063.505

6063.101

2

 

Installation

for 3/4" Top Spud Urinals

 

 

 

M968567 Rev. 1.2

 

 

 

 

CLOG RESISTANT

 

 

 

 

• Self-cleaning piston valve prevents clogging and reduces maintenance.

 

9

 

ONE SENSOR FITS ALL

 

 

 

• Only 1 sensor for entire Selectronic™ line of faucets, urinals, and flush valves.

 

 

• Range can be adjusted manually or with optional remote control.

 

 

 

• Sensor Features Low Battery Indicator.

 

 

 

 

Certified to comply with ASME A112.19.2M

 

 

 

 

© 2008 AS America, Inc.

 

3

 

 

 

 

 

 

NOTE TO INSTALLER: Please give this manual to the customer after installation.

 

 

To learn more about American Standard Faucets visit our website at: www.americanstandard-us.com

 

 

or U.S. customer's e-mail us at: faucetsupport@americanstandard.com

 

 

 

For Parts, Service, Warranty or other Assistance,

 

4

 

please call 1-800-442-1902 (In Canada: 1-800-387-0369)

 

 

(In Toronto Area onlly:: 1--905--3061093))

 

M968567 Rev.1.2

1

Fig. 1

 

GENERAL DESCRIPTION:

Roughing-in Dimensions

SELECTRONIC™

 

 

PROXIMITY URINAL

 

DETECTION ZONE

FLUSH VALVE

 

400mm-800mm

Exposed Flushometer

 

(15-3/4 TO 31-1/2)

72mm

FINISHED WALL

for 3/4" Top Spud Fixtures

Exclusive, self cleaning piston-type flush

(2-7/8)

57mm

 

valve with proximity operation and

 

(2-1/4 MIN.)

 

 

manual override. Operates on DC

116mm

15˚

(battery) power. Recommended

 

operating pressure 35 to 80 psi. Can

(4-5/8)

 

 

install left or right-handed. Detection

 

 

 

 

Zone can also be adjusted manually, or

 

 

with optional remote control.

MANUAL

 

 

OVERRIDE

 

 

BUTTON

SUPPLY

Right or Left Hand Installation

 

DN 19mm

 

(3/4” I.P.S.)

 

 

See (Section 5) for converting Flush

115mm-134mm

 

Valve to Left Hand Installation.

(4-1/2 TO 5-1/4)

409mm

 

293mm

(16-1/8)

 

(11-1/2)

 

 

 

FOR 3/4" TOP

 

 

SPUD FIXTURES

 

RECOMMENDED TOOLS; Fig. 2

1.Teflon Tape

2.Flat Blade Screwdriver (For adjusting Supply Stop)

3.Adjustable Wrench

4.Tape Measure

5.Hacksaw

6.Tubing Cutter

7.File

8.For Sweat Connection; Solder and Torch

9.2.5mm Hex Wrench

10.1.5mm Hex Wrench

Fig. 2

 

 

 

 

1

2

 

 

3

 

4

 

 

 

 

10'

 

 

 

 

 

 

 

 

 

6

 

5

 

 

8

 

7

 

9

10

PRIOR TO INSTALLATION

 

Note: Prior to installing the Selectronic™Flush Valve

• Flush all water lines prior to operation (See Step 4). Dirt

the following items must be installed.

and debris can cause flush valve to run continuously.

1. Urinal

• With the exception of Supply Stop Inlet, DO NOT use

 

pipe sealant or plumbing grease on any valve component

2. Drain line

or coupling!

 

3. Water supply line

• Protect the chrome or special finish on the Flushometer.

DO NOT USE toothed tools on finished surfaces to install

 

IMPORTANT:

or service these valves. Also see “Care and Cleaning”

section of this manual.

• All plumbing must be installed in accordance with

 

applicable codes and regulations.

• This product contains mechanical and/or electrical

 

components that are subject to normal wear. These

• Water supply lines must be sized to provide an

components should be checked on a regular basis and

adequate volume of water for each fixture.

replaced as needed to maintain the valve’s performance.

 

 

 