Installation Instructions
SELECTRONIC™
PROXIMITY TOILET FLUSH VALVE 1.28 & 1.6 GPF
MODEL NUMBERS
6065.161 6065.162
6065.121 6065.122
6065.565 6065.525
Bowls
CLOG RESISTANT
• Self-cleaning piston valve prevents clogging and reduces maintenance.
ONE SENSOR FITS ALL
•Only 1 sensor for entire Selectronic™ line of faucets, urinals, and flush valves.
•Range can be adjusted manually or with optional remote control.
•Sensor Features Low Battery Indicator.
Certified to comply with ASME A112.19.2M
© 2008 AS America, Inc.
M968699 Rev.1.3
NOTE TO INSTALLER: Please give this manual to the customer after installation.
To learn more about American Standard Faucets visit our website at: www.americanstandard-us.com or U.S. customer's e-mail us at: faucetsupport@americanstandard.com
For Parts, Service, Warranty or other Assistance,
please call 1-800-442-1902 (In Canada: 1-800-387-0369)
(In Toronto Area onlly:: 1--905--3061093))
Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.
UNPACKING All American Standard Products Are Water Tested At Our Factory. Some Residual Water May Remain In The Valve During Shipping.
1. Remove the Flush Valve items from the carton. The illustration below shows all items after they have been removed from the carton. Some items may be packaged partially assembled to other items.
1. |
Flush Valve Assembly |
5. |
Sweat Solder Adapter |
2. Down Tube and Vacuum Breaker |
6. Cover Tube |
||
3. |
Spud Coupling Nut and Washers |
7. |
Wall Escutcheon |
4. |
Spud Flange |
8. |
Supply Stop |
|
|
9. |
Installation Instructions |
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.
DO NOT REMOVE PROTECTIVE FILM FROM SENSOR
EYE UNTIL INSTALLATION IS COMPLETE.
|
6 |
7 |
5 |
8 |
1
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Instructions |
|
SELECTRONIC™ |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
PROXIMITY TOILET FLUSH VALVE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1.28 & 1.6 GPF |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
MODEL NUMBERS |
|
|
||
|
|
|
|
|
|
|
|
|
|
6065.161 |
6065.162 |
|
|
|
|
|
|
|
|
|
|
|
|
|
6065.121 |
6065.122 |
|
|
|
|
|
|
|
|
|
|
|
|
|
6065.565 |
6065.525 |
|
|
|
2 |
|
9 |
|
|
|
|
Bowls |
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
Installation |
|
M968699 Rev.1.3 |
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
CLOG RESISTANT |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
• Self-cleaning piston valve prevents clogging and reduces maintenance. |
|
||||
|
|
|
|
|
|
|
|
|
ONE SENSOR FITS ALL |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
• Only 1 sensor for entire Selectronic™ line of faucets, urinals, and flush valves. |
|
||||
|
|
|
|
|
|
|
|
|
• Range can be adjusted manually or with optional remote control. |
|
||||
|
|
|
|
|
|
|
|
|
• Sensor Features Low Battery Indicator. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Certified to comply with ASME A112.19.2M |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
© 2008 AS America, Inc. |
|
|
|
|
|
3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
NOTE TO INSTALLER: Please give this manual to the customer after installation. |
|
|
||||||
|
|
|
|
|
|
|
To learn more about American Standard Faucets visit our website at: www.americanstandard-us.com |
|
|
|||||
|
|
|
|
|
|
|
or U.S. customer's e-mail us at: faucetsupport@americanstandard.com |
|
|
|
|
|||
|
|
|
|
|
|
|
For Parts, Service, Warranty or other Assistance, |
|
|
|
|
|||
|
|
|
|
|
|
|
please call 1-800-442-1902 (In Canada: 1-800-387-0369) |
|
|
|||||
|
|
|
|
|
|
|
|
|
(In Toronto Area onlly:: 1--905--3061093)) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4
M968699 Rev. 1.3
1
Fig. 1 |
|
|
GENERAL DESCRIPTION: |
|
Roughing-in Dimensions |
|
|||
DETECTION ZONE |
SELECTRONIC™ |
|
||
|
|
400mm-800mm |
PROXIMITY TOILET |
|
|
|
(15-3/4 TO 31-1/2) |
|
|
|
|
|
FLUSH VALVE |
|
|
72mm |
FINISHED WALL |
Exposed Flushometer |
|
|
(2-7/8) |
|
|
|
|
|
57mm |
for 1-1/2" Top Spud Fixtures |
|
|
|
(2-1/4 MIN.) |
Exclusive, self cleaning piston-type flush |
|
|
|
|
||
|
|
15˚ |
valve with proximity operation and |
|
116mm |
|
|
manual override. |
Operates on DC |
(4-5/8) |
|
|
(battery) power. Recommended |
|
|
|
|
||
|
|
|
operating pressure 35 to 80 psi. Can |
|
|
|
|
install left or right-handed. Detection |
|
MANUAL |
|
|
Zone can also be adjusted manually, or |
|
|
|
with optional remote control. |
||
OVERRIDE |
|
|
||
BUTTON |
SUPPLY |
|
|
|
|
DN 25mm |
|
|
|
|
(1” I.P.S.) |
|
|
|
|
115mm-134mm |
|
Right or Left Hand Installation |
|
|
|
See (Section 5) for converting Flush |
||
|
(4-1/2 TO 5-1/4) |
Y |
||
|
|
|||
X |
|
|
Valve to Left Hand Installation. |
|
|
FOR 1-1/2" TOP |
|
|
|
|
SPUD FIXTURES |
|
|
|
MODEL |
X |
Y |
|
|
|
6065.121 |
293mm |
409mm |
6065.161 |
(11-1/2) |
(16-1/8) |
|
|
|
6065.122 |
683mm |
799mm |
6065.162 |
(27) |
(31-1/2) |
|
|
|
RECOMMENDED TOOLS; Fig. 2
1.Teflon Tape
2.Flat Blade Screwdriver
3.Adjustable Wrench
4.Tape Measure
5.Hacksaw
6.Tubing Cutter
7.File
8.For Sweat Connection; Solder and Torch
9.2.5mm Hex Wrench
10.1.5mm Hex Wrench
Fig. 2 |
|
|
|
|
1 |
2 |
|
|
3 |
|
4 |
|
|
|
|
|
10' |
|
|
|
|
|
|
|
|
|
|
|
6 |
|
5 |
|
|
8 |
|
7 |
|
9 |
10 |
PRIOR TO INSTALLATION |
|
|
Note: Prior to installing the Selectronic™Flush Valve |
• Flush all water lines prior to operation (See Step 4). Dirt |
|
the following items must be installed. |
and debris can cause flush valve to run continuously. |
|
1. Water Closet |
• With the exception of Supply Stop Inlet, DO NOT use |
|
|
pipe sealant or plumbing grease on any valve component |
|
2. Drain line |
or coupling! |
|
|
||
3. Water supply line |
• Protect the chrome or special finish on the Flushometer. |
|
DO NOT USE toothed tools on finished surfaces to install |
||
|
||
IMPORTANT: |
or service these valves. Also see “Care and Cleaning” |
|
section of this manual. |
||
• All plumbing must be installed in accordance with |
||
|
||
applicable codes and regulations. |
• This product contains mechanical and/or electrical |
|
|
components that are subject to normal wear. These |
|
• Water supply lines must be sized to provide an |
components should be checked on a regular basis and |
|
adequate volume of water for each fixture. |
replaced as needed to maintain the valve’s performance. |
|
|
|
|
|
M968699 Rev. 1.3 |