INSTALLATION INSTRUCTIONS

For Two-Piece Toilets with Aquameter™ Fill Valve

RENAISSANCE 2241

COMPACT 2149.012, 3505

COLONY 2388 / 2399 / 2359

COLONY AFTON 2329.016

Thank you for selecting American Standard - the benchmark of fine quality for over 100 years. To ensure this product is installed properly, please read these instructions carefully before you begin. (Certain installations may require professional help.) Also be sure your installation conforms to local codes

!CAUTION: PRODUCT IS FRAGILE. TO AVOID BREAKAGE AND POSSIBLE INJURY

HANDLE WITH CARE!

NOTE: Pictures may not exactly define contour of china and components.

U S E

RECOMMENDED TOOLS AND MATERIALS

Putty Knife

Regular Screwdriver

Adjustable Wrench

Sealant

Tape Measure

Hacksaw

Wax Ring/Gasket

Flexible Supply Tube

Closet Bolts

Carpenters Level

1REMOVE OLD TOILET

a.Close toilet supply valve and flush tank completely. Towel or sponge remaining water from tank and bowl.

b.Disconnect and remove supply line. NOTE: If replacing valve, first shut off main water supply!

c.Remove old mounting hardware, remove toilet and plug floor waste opening to prevent escaping sewer gases.

d.Remove closet bolts from flange and clean away old wax, putty, etc. from base area. NOTE: Mounting surface must be clean and level before new toilet is installed!

2 ROUGHING-IN DIMENSIONS:

NOTE: Distance from wall to closet flange centerline must be as listed below:

For 4010.010/4310.016 Tanks: A = 254mm (10") For 4014/4314 Tanks: A = 356mm (14")

For 4010.012/4392.016 and all other Tanks: A = 305mm (12")

FINISHED WALL

SUPPLY

AS

REQ'D.

A

FINISHED

FLOOR

 

3

CLOSET FLANGE

A

CLOSET BOLTS

INSTALL CLOSET BOLTS

Install closet bolts in flange channel, turn 90° , and slide into place 6" (152 mm) apart and parallel to wall.

S A V E F O R F U T U R E

Saniwares

P r o d u c t n a m e s l i s t e d h e r e i n a r e t r a d e m a r k s o f A m e r i c a n S t a n d a r d I n c . © A m e r i c a n S t a n d a r d I n c . 2 0 0 4

730237-100 REV. Q

American Standard Renaissance 2241, Compact 2149.012, 3505, Two-Piece Toilets with Aquameter, Compact 3505 User Manual

4

 

SEALANT

WAX RING

 

INSTALL WAX SEAL

Invert toilet on floor (cushion to prevent damage), and install wax ring evenly around waste flange (horn), with tapered end of ring facing toilet. Apply a thin bead of sealant around base flange.

5

NUT

TAPERED

WASHER

CLOSET

BOLT

FLANGE

POSITION TOILET ON FLANGE

a.Unplug floor waste opening and install toilet on closet flange so bolts project through mounting holes.

b.Loosely install retainer washers and nuts. Side of washers marked "THIS SIDE UP" must face up!

6

BOLT CAP

CLOSET FLANGE

CLOSET BOLT

WASHER NUT

INSTALL TOILET

a. Position toilet squarely to wall and, with a rocking motion, press bowl down fully on wax ring and flange. Alternately tighten nuts until toilet is firmly seated on floor.

! CAUTION:

DO NOT OVERTIGHTEN NUTS OR BASE MAY BE DAMAGED!

b.Install caps on washers. (If necessary, cut bolt height to size before installing caps.)

c.Smooth off the bead of sealant around base. Remove excess sealant.

7a

For Tanks/Bowls using Speed

 

Connect System (Tank

mounting bolts pre-installed).

TANK MTG.

RUBBER

GASKET

BOLTS PRE-

 

INSTALLED

 

WASHER

NUT

INSTALL TANK

a.Install large rubber gasket over threaded outlet on bottom of tank and lower tank onto bowl so that tapered end of gasket fits evenly into bowl water inlet opening, and tank mounting bolts go through mounting holes. Secure with metal washers and nuts.

b.With tank parallel to wall, alternately tighten nuts until tank is snugged down evenly against bowl surface.

! CAUTION:

DO NOT OVERTIGHTEN NUTS MORE THAN REQUIRED FOR A SNUG FIT!

7b For all other Tanks/Bowls

RUBBER

WASHER

RUBBER TANK MTG. GASKET

BOLTS

WASHER

NUT

INSTALL TANK

a.Install large rubber gasket over threaded outlet on bottom of tank and lower tank onto bowl so that tapered end of gasket fits evenly into bowl water inlet opening.

b.Insert tank mounting bolts and rubber washers from inside tank, through mounting holes, and secure with metal washers and nuts.

c.With tank parallel to wall, alternately tighten nuts until tank is snugged down evenly against bowl surface.

! CAUTION:

DO NOT OVERTIGHTEN NUTS MORE THAN REQUIRED FOR A SNUG FIT!

8

INSTALL TOILET SEAT Install toilet seat in accordance with manufacturer's directions.

 

- 2 -