Installation

Instructions

ENFIELD

T373.742

BATH/SHOWER

T373.741

TRIM KITS

T373.740

 

Thank you for selecting American-Standard...thebenchmark of fine quality for over 100 years.

To ensure that your installation proceeds smoothly--pleaseread these instructions carefully before you begin.

Certified to comply with ANSI A112.18.1

M 9 6 8 2 9 4 R E V 1 . 1

ATTENTION:

If TRIM T373.742 or diverter tub spout is used make sure TWIN ELL (B) P/N 8888.120 is connected to valve body as indicated in roughingin sketch.

TWIN ELL

TWIN ELL P/N 8888.120 can be ordered as shown in the American Standard List Price Book

ROUGHING-INDIMENSIONS

Installation for Bath/Shower,

Shower only, or Valve only Trim.

Dimensions are for reference.

 

FINISHED WALL

1/2" NPT

1" MIN.

 

 

 

 

 

5-1/8"REF.

 

7-7/8"REF.

 

 

 

OPTIONAL TO FINISHED

 

 

FLOOR USUALLY

 

 

BETWEEN 74'' AND 80''

 

 

FOR HEAD CLEARANCE

9-1/2"

4"

 

 

 

 

18" OPTIONAL

 

1" MIN.

 

4"

 

 

1/2" NPT

5-3/4"REF.

TOP OF

TUB RIM

 

 

BOTTOM OF TUB

Required Tools

Phillips Screwdriver

Flat Blade Screwdriver

Adjustable Wrench

Channel Locks

1

TRIMINSTALL

CAUTION: Protect finish on SHOWER ARM,

SHOWER HEAD and TUB SPOUT when installing.

When finished tiling the wall, remove PLASTER GUARD (A) and turn off water supply.

Attach STEM ADAPTER (1) to TEMPERATURE CONTROL (2) valve stem with SELF TAPPING SCREW (3). Attach HANDLE SCREW (4) to VOLUME CONTROL ADAPTER (5).

Push CAPS (6) onto TEMPERATURE CONTROL (2) and VOLUME CONTROL ADAPTER (5).

Mount ESCUTCHEON (7) to valve body with SCREWS (8).

Push DIAL PLATE (9) over CAPS (6) and into the four alignment holes in ESCUTCHEON (7) and snap into place.

Remove PIPE CAP (10) and PIPE CAP (11) from shower pipe and tub filler pipe.

Install SHOWER ARM (17) with SHOWER ARM ESCUTCHEON (18), SHOWER HEAD (12) and TUB FILLER SPOUT (13) by threading onto pipe nipples. Use teflon tape or pipe sealant on pipe threads.

 

18

 

 

 

17

 

TOP

 

10

 

 

 

 

 

12

 

 

 

5

PLASTER GUARD (A)

 

4

 

 

 

 

6

7

(4) ALIGNMENT

 

 

 

HOLES FOR

 

 

 

DIAL PLATE

 

 

 

9

TWIN ELL (B)

2

 

 

 

 

 

 

3

 

 

 

1

 

 

 

8

 

 

11

13

 

 

 

 

 

M 9 6 8 2 9 4 R E V 1 . 1

2 INSTALL HANDLES

Align CROSS HANDLE (1) and push onto VOLUME CONTROL ADAPTER (2). Tighten set screw in CROSS HANDLE (1) securley with HEX WRENCH (3) supplied.

Align LEVER HANDLE (4) and push onto TEMPERATURE CONTROL ADAPTER (5). Tighten set screw in LEVER HANDLE (4) securley with HEX WRENCH (3) supplied.

2

1

4

5

3

3 TRANSPOSED SUPPLY PIPING OR BACK TO BACK INSTALLATION

Should the hot and cold water supply pipes have been transposed making adjustment impossible, proceed as follows:

Shut off water supply.

Remove handle and rim

Remove check stops andre-installthem transposed.

Important note: RED CHECK STOP is now on the right of the mixer body and the BLUE CHECK STOP is now on the left.

Turn the water supply back on and perform the temperature adjustment in step 2.

CHECK STOP (RED TO BLUE)

CHECK STOP (BLUE TO RED)

4 TEMPERATURE ADJUSTMENT

Loosen set screw in LEVER HANDLE ASSEMBLY (1) with HEX WRENCH (2) supplied and pull off LEVER HANDLE ASSEMBLY (1).

Check that arrow marking B points vertically upward. If not, push the BLACK CLAMP on the SECURING RING to the right, pull off KNOB MOUNT (3) and reinstall KNOB MOUNT (3) with arrow "B" vertically upward. See Figure 1.

SET HOT LIMIT STOP

The maximum mixed water temperature is set at 109 F at the factory. This setting can be changed if desired.

Remove the TEMPERATURE LIMIT STOP (H shaped Black Plastic part). Reinstall it at the desired notch as indicated in the diagram to limit the maximum mixed water temperature to 104 F or 112 F.

For 100 F adjustment, turn the water supply on. Turn KNOB MOUNT (3) until the spout temperature is 100 F. Check that arrow "A" on the KNOB MOUNT (3) still points vertically upward after adjusting the thermostat to 100 F.

If not, pull out the RED LOCKING DEVICE. Remove KNOB MOUNT (3) by pulling it towards you while standing directly in front of the valve.

Reinstall the KNOB MOUNT (3) with arrow marking "A" vertically upward.

 

ARROWS AT 12 O'CLOCK

Reinstall RED LOCKING DEVICE.

 

POSITION

 

(Vertically Upward)

 

 

 

3

 

KNOB MOUNT

Figure 1

 

BLACK

 

 

CLAMP

ARROW

 

 

 

ARROW

"A"

 

 

 

"B"

3

1

104

 

 

 

109

 

 

112

 

 

TEMPERATURE

 

 

LIMIT STOP

 

 

RED LOCKING

 

 

DEVICE

2

 

CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE

M962289-YYY0A

SHOWER ARM AND ESCUTCHEON

ENFIELD

BATH/SHOWER

TRIM KITS

MODEL NUMBER

T373.742

T373.741

T373.740

M962365-YYY0A

ESCUTCHEON AND SCREWS

907090-YYY0A

ESCUTCHEON CAP

A918434-YYY0A

ESCUTCHEON SCREWS

M950220-YYY0A

DIVERTER SPOUT (IPS)

HOT LINE FOR HELP

For toll-freeinformation and answers to your questions, call:1-800442-1902

Weekdays 8:00 a.m. to 8:00 p.m. EST

IN CANADA 1-800-387-0369(TORONTO1-905-306-1093)

Weekdays 8:00 a.m. to 7:00 p.m. EST

Product names listed herein are trademarks of American Standard Inc. © American Standard Inc. 2003

M953565-YYY0A

SHOWER HEAD

M909625-YYY0A

DIAL PLATE

M918318-0070A

HANDLE SCREW

M950119-YYY0A

CROSS HANDLE

ASSEMBLY

M950118-YYY0A

LEVER HANDLE

ASSEMBLY

M918990-0070A

SELF TAPPING

HANDLE SCREW

M918038-0070A

HANDLE ADAPTER

M962256-YYY0A

DIVERTER SPOUT

REPAIR KIT

Replace the "YYY" with appropriate finish code

CHROME

002

POLISHED NICKEL

008

BLACKENED BRONZE

068

POLISHED BRASS

099

SATIN

295

M 9 6 8 2 9 4 R E V 1 . 1

Installation

Instructions

R540

3/4" CENTRAL THERMOSTAT WITH VOLUME CONTROL

Thank you for selecting American-Standard...thebenchmark of fine quality for over 100 years.

To ensure that your installation proceeds smoothly--pleaseread these instructions carefully before you begin.

ROUGHING-INDIMENSIONS

CONNECTIONS ARE: 3/4" NPT

3/4" NPT SHOWER

TOP

Certified to comply with ANSI A112.18.1M ASSE 1016

M968480

6-1/4

3-15/16

II

 

 

 

 

7

 

 

 

 

II

 

 

 

 

3-5/8

 

3/4" NPT

 

 

INLET

 

 

 

 

3/4" NPT

3/4" NPT

 

 

INLET

 

 

TUB

1-5/8-2-1/2

 

 

 

5-7/8

 

 

THERMOSTATIC BATH/ SHOWER INSTALLATION USING A TWIN ELL, DIVERTER SPOUT AND FIXED SHOWER

 

C/L

80"-86"

 

18"

TUB PORT

(OPTIONAL)

MUST BE

 

PLUGGED

 

4"

TWIN

 

ELL

 

TOP OF TUB RIM

 

BOTTOM OF TUB

IMPORTANT: WHEN NOT USING A DIVERTER SPOUT A SEPARATE DIVERTER VALVE MUST BE USED.

THERMOSTATIC SHOWER INSTALLATION USING A DIVERTER VALVE, FIXED SHOWER HEAD AND ADJUSTABLE HAND HELD SHOWER

DIVERTER

VALVE

HOT

COLD

3/4"

3/4"

TUB PORT MUST

BE PLUGGED

THERMOSTATIC SHOWER INSTALLATION USING A DIVERTER VALVE, FIXED SHOWER HEAD, ADJUSTABLE HAND HELD SHOWER, ON/OFF VALVE AND TWO BODY SPRAYS

DIVERTER

VALVE

ON/OFF

VALVE

HOT

COLD

3/4"

3/4"

TUB PORT MUST

BE PLUGGED

NOTE: MINIMUM FLOWING PRESSURE REQUIRED FOR THIS SYSTEM OPERATING WITH ONE SHOWER HEAD AND 2 BODY SPRAYS IS 40 PSI

1

 

 

DO NOT SOLDER DIRECTLY TO THE VALVE BODY; THIS WILL DAMAGE

 

ROUGHING-INTHE VALVE

WARNING

MIXED

THE TEMPERATURE CONTROL ELEMENT AND CHECK STOP VALVES.

 

 

 

 

 

 

 

 

 

Prepare water supplies per ROUGHING-INDIMENSIONS. Make sure the finished wall is between the minimum and maximum rough dimension.

Install VALVE at indicated height and depth. Make sure the "TOP" marking on the PLASTER GUARD is up.

 

Connect the hot and cold water supplies. Assemble all connecting pipes. Flush lines to

 

 

 

 

remove any dirt. Connections are 3/4" NPT.

HOT

 

Assemble the connection pipe to one of the MIXED OUTLETS of the VALVE.

WOOD

 

 

Cap the other MIXED OUTLET. (Tub port is fitted with a plug at the factory).

 

BRACE

 

 

IMPORTANT! INSTALL ANY REQUIRED SHUT OFF OR DIVERTER VALVES

INTO THE PIPING SYSTEM.

1

If the CHECK STOPS (4, 5) were removed during installation, ensure the hot and cold CHECK STOPS (4, 5) are not reversed. The hot CHECK STOP (4) has a red top and the cold CHECK STOP (5) has a blue top.

CHECK STOPS (4,5) are supplied in the open position.

 

 

 

Closing using 5/32" (4 mm) hex wrench to pressure

 

 

 

test and to check for leaks.

 

 

 

To flush lines, remove the CHECK STOPS (4,5)

 

 

COLD

and run water. If desired, the TEMPERATURE

 

 

CONTROL UNIT can be removed. Reinstall CHECK

 

 

 

STOPS (4,5) and CONTROL UNIT (6), if it was

 

 

 

removed.

3

PLUG

6

Remove PLASTER GUARD (2) if still installed.

 

TUB

 

Turn on water supplies and check for leaks.

 

PORT

2

 

 

 

Reassemble PLASTER GUARD (2) and FINISH

HOT

 

WALL.

 

 

 

Beware of Freezing. No water should remain

 

CHECK STOP

4

in the MIXING VALVE if freezing is a possibility.

 

Remove the CHECK STOPS (4,5) to completely

 

(HOT RED)

 

drain the MIXER UNIT (1).

 

 

 

2TEMPERATURE ADJUSTMENT

COLD

TOP

PLUG TUB

PORT

5CHECK STOP (COLD BLUE)

 

P

T

O

 

Unscrew PLASTER GUARD SCREWS and remove PLASTER GUARD.

 

Check that arrow marking B points vertically upwards. If not, push the BLACK

 

CLAMP on the SECURING RING to the right, pull off KNOB MOUNT and reinstall

 

KNOB MOUNT with arrow "B" pointing upwards.

 

The maximum mixed water temperature is set at 109 F at the factory.

TEMPERATURE

This setting can be changed if desired.

LIMIT STOP

 

Remove the TEMPERATURE LIMIT STOP (H shaped Black Plastic part). Reinstall it at the desired notch as indicated in the diagram to limit the maximum mixed water temperature to 104 F or 112 F.

For 100 F adjustment, turn the water supply on. Turn KNOB MOUNT until the spout temperature is 100 F. Check that arrow marking A on the KNOB MOUNT still points upward after adjusting the thermostat to 100 F. If not, pull out the RED LOCKING DEVICE. Remove KNOB MOUNT by pulling it towards you while standing directly in front of the valve.

Reinstall the KNOB MOUNT so that the arrow marking A points upwards.

Reinstall RED LOCKING DEVICE.

ARROW "B"

104

109

112

SECURING

RING

RED LOCKING

DEVICE

BLACK

CLAMP

ARROW "A"

KNOB

MOUNT

3TRANSPOSED SUPPLY PIPING OR BACK TO BACK INSTALLATION

Should the hot and cold water supply pipes have been transposed making adjustment impossible, proceed as follows:

Shut off water supply.

Remove handle and rim

Remove check stops andre-installthem transposed.

Important note: RED CHECK STOP is now on the right of the mixer body and the CHECK STOP is now on the left.

Turn the water supply back on and perform the temperature adjustment in step 2.

CHECK STOP (BLUE TO RED)

CHECK STOP

(RED TO BLUE)

M968480

3/4" CENTRAL THERMOSTAT WITH VOLUME CONTROL

MODEL NUMBER

R540

912647-0070A

O-RING

A953971-0070A

CHECK STOP (COLD BLUE)

A994352-0070A

CARTRIDGE

923348-0070A

HANDLE ADAPTER

918428-0070A

CARTRIDGE SCREW

 

954040-0070A

 

953963-0070A

 

 

HANDLE EXTENSION

 

THERMOSTAT

 

 

 

 

 

CARTRIDGE

 

 

A953972-0070A

 

 

953957-0070A

CHECK STOP (HOT RED)

 

912647-0070A

 

TEMPERATURE

 

 

O-RING

 

 

CALIBRATION UNIT

 

 

 

963434-YYY0ADEEP ROUGH KIT

(SOLD SEPARATELY)

HOT LINE FOR HELP

For toll-freeinformation and answers to your questions, call:1-800442-1902

Weekdays 8:00 a.m. to 8:00 p.m. EST

IN CANADA 1-800-387-0369(TORONTO1-905-306-1093)

Weekdays 8:00 a.m. to 7:00 p.m. EST

Product names listed herein are trademarks of American Standard Inc.

 

© American Standard Inc. 2003

M968480