ELLISSE OVAL™

WHIRLPOOL AND BATHING POOL

HIGH GLOSS

ELLISSE OVAL™ WHIRLPOOL and

BATHING POOL

2709.028WC Whirlpool featuring System II

Acrylic with fiberglass reinforcement

Pre-leveledtub bottom

Factory installed power cord and plug

Six multi-directionalandflow-adjustablebody massage jets

Pre-Drilledfor grab bars (purchased separately)

Two silent air volume controls

Quick Connect Safe-T-Heaterconnection system

Factory installed and tested whirlpool system

2.1 HP, two speed self-drainingpump/motor with dry run seal and Pulse feature

Deck-mountedelectronic On/Off with 20 minutebuilt-intimed safety shut off and chrome bezel

EverClean® System

2709.028WC.K2 Whirlpool Massage

with Chromatherapy

Same as 2709.018WC but also includes:

• Two digitally controlled lights

• Electronic control with color selector and

 

color cycle function

 

 

To Be Specified - Required:

 

 

 

2709.002 Bathing Pool only

Color:

Bath Filler: (specify finish)

 

 

Nominal Dimensions:

Bath Drain: 1583.470 (specify finish)

Grab Bar Kit: 9827-200-twoper kit (specify finish)

1759 x 978 x 502mm

 

(69-1/4"x38-1/2"x19-3/4")

 

To Be Specified - Optional:

 

 

Safe-T-Heater*:9075.120

Compliance Certifications -

 

Jet Trim Ring Kit: 9860.200-twoper kit (specify color)

Meets or Exceeds the Following Specifications:

 

System II Control Bezel: 9861.100 (specify finish)

• Underwriters Laboratories - Hydromassage

 

Air Blower Remote Mounting Kit: 754025-0071A

 

 

 

Bathtubs UL 1795

 

 

 

 

For color/finish availability and other faucet choices, please

• ASME A112.19.7M for Whirlpool Appliances

 

 

see the Product Selector and Pricing Guide.

• ANSI Z124.1 for Plastic Bathtubs

 

 

 

 

• ASTM E162 for Flammability

 

* NOTE: theSafe-T-Heateris designed to maintain water

• NFPA 258 for Smoke Density

 

 

temperature during operation. It will not heat cold water to

American Standard whirlpools and air baths with

 

desired bathing temperature.

 

 

 

EverClean® incorporate a patentedsilver-ion

 

 

 

additive right into the circulation piping to protect

 

 

 

the pipes from mold, mildew, algae and fungus that

 

 

 

could cause deterioration or staining of the pipes.

 

 

 

SEE REVERSE FOR PRODUCT DIMENSIONS

 

 

 

AND SPECIFICATIONS

 

 

 

 

H49

 

© 2008 AS America Inc.

Rev. 2/08

 

 

 

 

 

 

 

 

 

 

 

 

 

ELLISSE OVAL™

 

 

 

 

 

 

 

 

WHIRLPOOL AND BATHING POOL

 

 

 

 

 

 

 

 

 

 

 

 

 

HIGH GLOSS

 

 

 

 

 

1759 mm

 

 

 

 

 

 

1759 mm

 

 

 

 

240 mm

(69-1/4)

 

 

 

 

240 mm

(69-1/4)

 

 

 

 

 

OUTLINE OF

 

 

 

OUTLINE OF

 

 

 

(9-7/16)

 

 

 

(9-7/16)

 

 

 

 

 

CUTOUT

 

 

 

 

CUTOUT

 

 

 

 

 

 

 

 

 

 

 

 

SEE FTTG.SPECS

 

 

 

 

 

 

 

SEE FTTG.SPECS

 

 

 

 

 

FOR DIMENSION

 

 

 

 

 

 

 

FOR DIMENSION

 

 

 

 

 

C OF SUPPLIES

 

 

 

 

ON/OFF

 

 

C OF SUPPLIES

 

 

 

 

 

 

 

 

 

SWITCH

 

 

 

 

 

 

 

L

 

 

 

 

 

 

L

 

 

 

 

 

 

 

 

 

305mm(12) X 229mm(9)

 

PUMP

 

 

 

305mm(12) X 229?mm(9)

 

 

 

 

 

CUTOUT IN FLOOR FOR DRAIN

 

 

 

 

CUTOUT IN FLOOR FOR DRAIN

978 mm

 

 

 

 

 

 

 

978 mm

 

 

 

 

 

(38-1/2)

 

 

 

 

 

 

 

(38-1/2)

 

 

 

 

 

489mm

 

 

 

 

 

 

 

489mm

 

 

 

 

 

 

 

 

 

 

 

 

(19-1/4)

 

 

 

 

 

(19-1/4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PROVIDE ACCESS

76mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TO PUMP FOR

 

(3)

 

 

 

 

76mm

 

 

 

 

SERVICING ON ALL

 

 

CLOF DRAIN

 

 

 

 

 

 

 

 

INSTALLATIONS

 

 

 

 

 

 

(3)

 

 

 

 

 

 

 

OUTLET

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CL OF DRAIN

 

 

 

 

 

 

 

 

 

 

 

 

OUTLET

 

 

 

 

 

 

 

 

 

C/L OF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C/L OF

 

 

 

 

 

SHOWER ARM

 

 

 

 

 

 

 

 

 

 

 

 

 

SAFE-T-HEATER

C/L OF

 

SHOWER ARM

 

 

 

C/L OF

 

 

 

VALVES

 

 

 

 

 

 

VALVES

 

 

 

REMOVABLE BLANK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

86mm

 

 

 

 

C/L OF

 

 

95mm

 

 

 

C/L OF

 

(3-3/8)305mm

102mm

 

 

 

(3-3/4)305mm

 

 

 

 

SPOUT

 

 

102mm

 

SPOUT

 

38mm

(12)

(4)

 

 

 

 

 

38mm

(12)

(4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1-1/2)

 

 

 

 

 

 

1651-1981mm

(1-1/2)

 

 

 

 

1651-1981mm

 

 

 

 

 

 

 

(65-78)

 

 

 

 

 

(65-78)

502mm

 

 

 

 

 

INTEGRAL

OPTIONAL

 

 

 

 

 

OPTIONAL

 

 

 

 

 

 

502mm

 

 

 

 

INTEGRAL

(19-3/4)

 

 

 

 

 

FEET

 

(19-3/4)

 

 

 

 

FEET

464mm

 

 

 

 

 

SUPPORT

 

464mm

 

 

 

 

SUPPORT

(18-1/4)

 

 

 

 

 

ROUGH

 

(18-1/4)

 

 

 

 

ROUGH

 

 

 

 

 

 

FLOOR

 

 

 

 

 

 

FLOOR

 

 

1-1/2N.P.T.M.

 

35mm

 

 

 

 

1-1/2N.P.T.M.

 

 

 

 

 

 

THREADS

 

 

 

 

 

THREADS

 

35mm

 

 

 

1-1/2O.D.

 

(1-3/8)

98mm

 

 

 

1-1/2O.D.

 

(1-3/8)

98mm

 

 

 

 

 

 

 

 

 

 

 

 

(3-7/8)

 

 

 

 

 

 

 

TAILPIECE

 

 

 

 

 

TAILPIECE

 

 

(3-7/8)

 

 

 

 

 

 

 

 

 

 

GENERAL SPECIFICATIONS FOR 2709 WHIRLPOOL

INSTALLED SIZE

 

 

 

 

 

69-1/4x38-1/2x19-3/4In.(1759 x 978 x 502mm)

WEIGHT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

107 Lbs. (49 Kg.)

WEIGHT w/WATER

 

 

 

 

 

 

 

 

 

 

640 Lbs. (291 Kg.)

 

 

 

 

 

 

 

 

 

 

GAL. TO OVERFLOW

 

 

 

 

 

 

 

 

 

 

 

 

 

64 Gal. (243 L)

 

 

 

 

 

 

 

 

 

 

 

 

WHIRLPOOL MIN. OPERATING VOL.

 

 

 

 

 

 

 

 

53 Gal. (201 L)

 

 

 

 

 

 

 

BATHING WELL AT SUMP

 

 

 

 

45 x 23 In. (1143 x 584mm)

BATHING WELL AT RIM

 

 

 

 

 

 

63 x 32 In. (1600 x 813mm)

 

 

 

 

 

 

WATER DEPTH TO OVERFLOW

 

 

 

 

 

 

 

 

 

13 In. (330mm)

 

 

 

 

 

 

 

 

 

FLOOR LOADING

 

 

 

 

 

 

35 Lbs./Sq.Ft. (166 Kgs./Sq.m)

(PROJECTED AREA)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PTS.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25.6

CUBE (FT3)

 

 

 

 

 

 

49.4

 

 

 

 

 

 

 

 

 

WHIRLPOOL ELECTRICAL SPECIFICATIONS

SYSTEM II PUMP

 

 

 

 

 

 

 

 

2.1 HP, 15.6 AMPS, 120V.

 

 

 

 

 

 

 

 

NOTES:

GENERAL SPECIFICATIONS FOR 2709 BATHING POOL

INSTALLED SIZE

 

 

 

 

 

 

 

 

 

 

69-1/4x38-1/2x19-3/4In.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1759 x 978 x 502mm)

WEIGHT

 

 

 

 

 

 

 

77 Lbs. (35 Kg.)

 

 

 

 

 

 

 

WEIGHT w/WATER

 

 

 

 

 

 

 

 

 

611 Lbs. (275 Kg.)

 

 

 

 

 

 

 

 

 

GAL. TO OVERFLOW

 

 

 

 

 

 

 

 

 

 

 

64 Gal. (243 L)

 

 

 

 

 

 

 

 

 

 

BATHING WELL AT SUMP

 

 

 

 

45 X 23 In. (1143 x 584mm)

 

 

 

 

BATHING WELL AT RIM

 

 

 

 

 

63 x 32 In. (1600 x 813mm)

 

 

 

 

 

WATER DEPTH TO OVERFLOW

 

 

 

 

 

 

 

 

13 In. (330mm)

 

 

 

 

 

 

 

 

FLOOR LOADING

 

 

34 Lbs./Sq.Ft. (165 Kgs./Sq.m)

 

 

(PROJECTED AREA)

 

 

 

 

 

 

 

 

 

 

PTS.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25.6

CUBE (FT3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

49.4

BATH CAN BE INSTALLED EITHER ABOVE OR BELOW FLOOR LINE AS PIER, ISLAND OR PENINSULA TYPE INSTALLATION. SUPPORT OF BATH BY INTEGRAL FEET. NO ADDITIONAL SUPPORT IS REQUIRED. SUPPORT AND ENCLOSING MATERIAL BY OTHERS.

REFER TO INSTALLATION INSTRUCTIONS SUPPLIED WITH WHIRLPOOL FOR ADDITIONAL INFORMATION.

CUTOUT TEMPLATE PROVIDED IN SHIPPING BOX. MAY BE REQUESTED SEPARATELY.

FITTINGS NOT INCLUDED AND MUST BE ORDERED SEPARATELY.

PROVIDE SUITABLE REINFORCEMENT FOR ALL SUPPORTS.