Installation

Instructions

BERWICK/ BOULEVARD7430.801

SPREAD LAVATORY FAUCET

7430.821

with Speed Connect™ Drain

7431.801

 

 

7431.821

Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets.

Speed Connect Drain*

7430 . 821

7431 . 821

7430 . 801

7431 . 801

Certified to comply with ANSI A112.18.1

Fewer parts, installs in less time

Never needs adjustment

Guaranteed to seal properly the first time, every time.

*Your new American Standard faucet is designed to work only with the Speed Connect drain.

M968640 REV . 1 . 1

To ensure that your installation proceeds smoothly-pleaseread these instructions carefully before you begin.

Recommended tools

 

 

Screwdriver

 

Channel Locks

Adjustable Wrench

Tubing Cutter

 

 

 

 

 

 

 

 

1

 

 

Turn off hot and cold water

 

 

 

 

INSTALL FAUCET

CAUTION

 

 

 

 

supplies before beginning.

 

 

 

 

 

 

 

 

 

NOTE: READ STEP #16 BEFORE INSTALLING SPOUT TO CONVERT FROM SWIVEL TO FIXED SPOUT.

Seat SEAL (1) into under side of SPOUT BASE(2).

Feed FAUCET SUPPLIES (3), MOUNTING STUD(4) and DRAIN CABLE ASSEMBLY(8) through the mounting hole of lavatory or mounting surface.Figure A.

From below, slide DRAIN CABLE ASSEMBLY (8) and FAUCET SUPPLIES(3) through opening in the SPACER(9) against underside of deck.Figure B. Note: For thick deck installaitons the SPACER(9) is not required.

From below, push GASKET (7) and RETAINING WASHER(5) onto MOUNTING STUD(4). Secure Faucet with MOUNTING NUT(6),

pulling faucet to front of sink, so SUPPLIES (3) rests againstFigure A mounting hole. Before final tightening, make sure collar on

MOUNTING NUT (6) is seated into RETAINING WASHER(5).

Figure B.

Adjust Faucet so that it is centered. Tighten MOUNTING NUT (6)

 

to complete faucet mounting.

 

GROOVE

 

 

 

 

(FAUCET

 

 

BASE)

 

 

4

 

9

MOUNTING

 

 

SURFACE

 

7

 

Figure B

5

 

 

6

 

COLLAR ON

4

8

MOUNTING NUT

 

2

1

3

5

1

2 VALVE INSTALLATION

 

Place RUBBER RING (9) into DECK ADAPTER(10).

 

Install LOCKNUT (11) and RUBBER WASHER(12) onto VALVE BODY(13).

 

From under side of mounting surface, install VALVE BODY (13) through valve

 

mounting holes. Threads of VALVE BODY (13) should extent at least 5/16

 

of a inch above mounting surface top. Fig. A. Thread DECK ADAPTER(10)

 

onto VALVE BODY (13) until snug against internal stop. If necessary, adjust

 

LOCKNUT (11).

1

 

10

9

5/16'' MIN.

MOUNTING

SURFACE

10

9

13

Fig. A.

 

12

12

11

 

11

 

13

13

 

8

 

3 VALVE OUTLET SUPPLY CONNECTION

Connect Red Banded Hose to Left

Valve and Blue Banded Hose to

Right Valve.

Attach COUPLING NUTS (1) of SUPPLY HOSES(2) and tighten making water tight connection.

Important: Loop SUPPLY HOSES (2) as illustrated so they do not kink.

HOT

2

BLUE

COLD

 

BAND

1

RED BAND

4 INSTALL HANDLES

Push ADAPTER (1) on VALVE STEM(2). Tighten

STEM SCREW (3) with a flat blade to secure ADAPTER(1).

(Figure A)

Find correct position of HANDLE ASSEMBLY (4, 4a) by adjusting male teeth on ADAPTER(1) to female teeth in HANDLE(4, 4a).

Thread HANDLE ASSEMBLY (4, 4a) onto DECK

ADAPTER (5) until snug against mounting surface.

FLAT BLADE SCREWDRIVER

(Figure A)

LEVER HANDLE

CROSS HANDLE

4

4a

THREAD ON

TO DECK

ADAPTER

 

1

1

3

 

2

 

5

M968640 REV . 1 . 1

2

5 POP-UPDRAIN

Fig. A.

Fig. B.

Remove CLEAR PLASTIC COVER (1).

1

 

Remove CARDBOARD SPACER (2) from under

3

DRAIN

DRAIN POP-UP(3).

BODY

Tighten TAILPIECE (4) on DRAIN BODY before

 

 

installing DRAIN BODY. Fig. B.

 

 

 

2

4

 

 

6 REMOVE FLANGE

Fig. A.

 

Fig. B.

Thread FLANGE (1) counter-clockwiseand remove

1

 

 

 

 

 

FLANGE (1) and FOAM GASKET(2) from drain

 

 

 

body. Fig. A.

 

 

 

Thread LOCKNUT (3) clock-wiseto bottom of

 

 

 

drain body. Push GASKET (4) down against

 

 

 

LOCKNUT (3). Fig. B.

 

2

4

 

 

 

3

7

INSTALL DRAIN FROM

 

 

8 TIGHTEN LOCKNUT

 

BELOW FIXTURE

 

REAR OF SINK

 

 

From under side of SINK

 

 

Tighten LOCKNUT (1) firmly with Adjustable

 

install DRAIN BODY (1) up

4

 

Wrench or Channel Locks.

 

 

through drain outlet.

 

 

 

 

Note: No plumber’s putty

 

OUTLET

 

 

 

or caulk is required.

3

 

 

 

The CABLE ATTACHMENT

 

 

 

 

POINT (2) must face towards

 

 

 

 

 

the rear of the SINK.

 

 

 

1

 

Install FOAM GASKET (3) and

 

1

 

 

 

 

 

 

FLANGE (4) onto drain body

 

2

 

 

 

from above SINK and tighten

 

 

 

 

 

FLANGE (4) firmly.

 

 

 

 

9 FLANGE GASKET ANDPOP-UPKNOB

Fig. A.

 

DOWN

 

Check DRAIN FLANGE in SINK to ensure that

 

 

 

 

WHITE FOAM GASKET (3) is fully compressed

 

 

 

 

and not visible. Fig. A.

 

 

 

 

 

POP-UPKNOB(1) must be fully down.Fig. B.

WHITE FOAM

DRAIN

 

 

 

 

GASKET

 

 

 

 

NOT VISIBLE

FLANGE

1

 

 

 

 

 

 

 

 

 

M968640 REV . 1 . 1

 

 

 

3

 

 

10 ATTACH CABLE CONNECTOR

Fig. A.

Fig. B.

Thread CABLE CONNECTOR (1) clockwise

 

 

onto DRAIN BODY CONNECTION (2) and

 

1

hand tighten. Fig. A.

 

 

 

Your new POP-UPDRAIN installation is

 

 

now complete. Fig. B.

 

 

Note: Tailpeice onpop-updrain is1-1/4”O.D.

 

 

Fig. B.

 

 

 

 

2

1-1/4”O.D.

11 CHECK OPERATION OFPOP-UP

Operate LIFT KNOB (1) to verify that STOPPER(2) opens and closes.

Note: If STOPPER(2) does not open and close properly then refer to the “troubleshooting section” of these instructions.

1

2

12 MAKE WATER SUPPLY AND WASTE CONNECTIONS

NOTE: FLEXIBLE SUPPLIES OR BULL-NOSERISERS MUST BE

PURCHASED SEPARATELY.

Connect water supply to FAUCET (1) with 1/2" IPS FLEXIBLE

 

SUPPLIES (2) or 3/8" O.D.BULL-NOSERISERS(3). Use

 

adjustable wrench to tighten connections.

COUPLING

Do not over tighten. Be careful not to kink copper supply when

NUT

 

bending. Use tubing cutter to cut to proper length.

1

 

3

 

FERRULE

2

M968640 REV . 1 . 1

4

13 TEST INSTALLED FITTING

With HANDLES (1) in OFF position, turn on WATER

SUPPLIES (2) and check all connections for leaks.

Remove AERATOR (3). First loosen aerator set screw with

HEX WRENCH (6) supplied. Pull out AERATOR(3) with

AERATOR KEY (7).

 

Operate both HANDLES (1) to flush water

1

 

 

lines thoroughly.

Replace AERATOR (3) and tighten set screw.

5

14 CHECK DRAIN CONNECTIONS

Operate POP-UPKNOB(5) and fill Sink with water. Check that DRAIN STOPPER(4) makes a good seal and retains water in Sink. If STOPPER(4) does not seal properly, please refer to “Troubleshooting Guide” in these instructions.

Release POP-UPKNOB(5) down and check all drain connections and "P" trap for leaks. Tighten

if necessary.

WASTE

OUTLET

2

HOT

6

1

AERATOR

SET

SCREW

3

7

4

2

COLD

“P” TRAP

15 SERVICE

16

SPOUT CAN BE FIXED OR SWIVEL.

CONVERT TO A FIXED SPOUT IF DESIRED.

To change direction of handle

To change from swivel to fixed spout, proceed as follows:

 

Remove PLUG BUTTON (1) from back of spout.VIEW “A”

rotation, proceed as follows:

 

Turn valve to OFF position.

 

Remove SET SCREW (2) using screwdriver.

 

Install FIXING SET SCREW (3) using Hex Wrench supplied.

Thread counter-clockwise

 

 

Align SPOUT (4) and tighten SET SCREW(3) to secure SPOUT(4).

HANDLE BASE (1) to remove

 

 

Replace PLUG BUTTON (1).

HANDLE ASSEMBLY (2) from

 

 

 

 

ESCUTCHEON BASE (3).

 

 

 

Use a flat blade screw driver

2

 

 

to remove SPRING CLIP (4).

1

 

 

Lift STOP WASHER (5), turn 90˚

 

 

1

and replace.

 

 

VIEW "A"

3

Replace SPRING CLIP (4).

Reinstall HANDLE ASSEMBLY (2).

 

 

4

If spout drips, operate handles

90˚

 

2

several times from OFF to ON

5

 

 

position. Do not force - handles

4

VIEW "A"

turn only 90˚.

3

 

 

VALVE

1

 

 

 

17 CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A

CLOTH WITH A COARSE SURFACE.

M968640 REV . 1 . 1

5

Speed Connect™ Drain

Troubleshooting Guide

If sink does not hold water even though Stopper is in the “down” position:

• Follow CABLE ADJUSTMENT PROCEDURE.

If Stopper does not raise up fully or sink drains too slowly:

• Follow CABLE ADJUSTMENT PROCEDURE.

If you need to remove the Stopper:

• Follow STOPPER REMOVAL PROCEDURE.

If you would like the ability to remove your Stopper simply by lifting it out of the drain:

Follow STOPPER INSTALLATION PROCEDURE for“Unlocked” mode.

CABLE ADJUSTMENT PROCEDURE

Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise.Fig. A.

Look at the area on the Drain Body where the Cable was attached and locate the component labeled as “Cam” in the illustration. Fig. B.

Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the Stopper should be in the UP position. Fig. B, C.

Push DOWN on the Lift-Knobto make sure it is fully down.Fig. C.

Re-attachthe Cable to the Drain Body Connection(2) by threading the Cable Connector(1) clockwise onto the Drain Body Connection(2) andhand-tighten.Fig. A.

Fig. A.

 

Fig. B.

Fig. C.

 

 

 

DOWN

1

CAM

 

 

 

 

 

RE-ATTACH

 

 

 

 

CAM CAP

 

1

DISCONNECT

 

 

STOPPER

2

 

 

 

STOPPER REMOVAL PROCEDURE

Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise.Fig. A.

Look at the area on the Drain Body where the Cable was attached and locate the component labeled as “Cam” and “Cam Cap” in the illustration. Fig. B.

Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig. D.

Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig. E.

The Stopper can now be removed by lifting it out of the Drain. Fig. F.

Fig. D.

Fig. E.

Fig. F.

 

 

REMOVE

 

 

CAM

 

REMOVE

 

 

CAM CAP

 

M968640 REV . 1 . 1

6

STOPPER INSTALLATION PROCEDURE

The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be removed) or “Unlock” Mode (Stopper is removable).

Locked Mode:

Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper. Fig. G.

To install the stopper in “Locked” mode, insert the Stopper into the Drain so that the Plastic Loop is facing toward the rear of the Sink and the American Standard logo is facing front. Rotate

Stopper slightly if necessary so that the Stopper slides all the way down.Fig. G.

Re-installthe Cam into the Drain, rotating the Cam if necessary to make sure it is fully inserted.Fig. J.

Re-installthe Cam Cap, making sure the guide teeth are facing outward. If the Cam Cap does not “snap” into place, then rotate the Cam to make sure it is fully inserted.Fig. K.

Fig. G.

LOGO

LOOP TOWARD

REAR OF SINK

DRAIN

Re-attachCable. See “CABLE ADJUSTMENT PROCEDURE” in Troubling Shooting Guide to complete installation. Stopper will be in“Locked” mode and not be removable.

Unlocked Mode:

Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper. Fig. H.

To install the stopper in “Unlocked” mode, insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the

Sink and the American Standard logo is facing rear. Rotate Stopper

slightly if necessary so that the Stopper slides all the way down.

Fig. H.

Re-installthe Cam into the Drain, rotating the Cam if necessary to make sure it is fully inserted.Fig. J.

Re-installthe Cam Cap, making sure the guide teeth are facing outward. If the Cam Cap does not “snap” into place, then rotate the Cam to make sure it is fully inserted.Fig. K.

Locked Mode

(Vandal Proof)

Fig. H.

LOGO

180˚

LOOP TOWARD

FRONT OF SINK

DRAIN

Re-attachCable. See “CABLE ADJUSTMENT PROCEDURE” in “Troublingshooting Guide” to complete installation. Stopper will be in“Unlocked” mode and removable.

Fig. J.

INSTALL CAM

Unlocked Mode

Fig. K.

CAM

INSTALL

CAM CAP

M968640 REV . 1 . 1

7

BERWICK/ BOULEVARD

 

SPREAD

 

LAVATORY FITTING

M962817-YYY0A

MODEL NUMBER

SPOUT KIT

7430.801

7431.801

 

 

7430.821/ 7431.821

 

M962420-YYY0A

M962837-YYY0A

POP-UPROD

CROSS HANDLE

 

ASSEMBLY

 

M962832-YYY0A

RIGHT LEVER

HANDLE ASSEMBLY

M962831-YYY0A

 

LEFT LEVER

 

HANDLE ASSEMBLY

 

M962905-0070A

 

SPOUT SET

 

SCREW KIT

M962818-0070A

 

AERATOR KIT

M962830-YYY0A

 

ESCUTCHEON KIT

 

918555-0070A

A912831-0070A

SPOUT O-RING

HANDLE SCREW

 

617852-0070A

 

M962492-0070A

 

HANDLE ADAPTER

 

 

 

MOUNTING KIT

M962544-YYY0A

 

 

 

 

 

 

 

 

STOPPER

994053-0070A

 

 

ASSEMBLY

 

M918462-0070A

 

CARTRIDGE

 

 

 

CABLE ADAPTER

 

 

 

 

 

 

 

M952430-0070A

 

 

 

CABLE ASSEMBLY

M961634-0070A

 

 

 

VALVE

 

 

M962457-YYY0A

MOUNTING

 

 

KIT

 

 

FLANGE

 

 

 

ASSEMBLY

 

 

M952425-YYY0A

 

 

 

DRAIN ASSEMBLY

 

 

 

 

M922872-0070A

 

 

 

CAM SEAT INSERT

 

 

 

M962552-0070A

 

 

 

CAM ASSEMBLY

024220-0070A

 

 

M913207-0070A

COUPLING NUT

 

 

TAILPIECE INSERT

Replace the "YYY" with

A923480-0070A

 

appropriate finish code

SPACER

 

CHROME

002

M919660-0020A

A919661-0020A

SATIN NICKEL

295

 

 

6” TAILPIECE

TAILPIECE

 

 

(NOT INCLUDED

 

 

 

WITH FAUCET)

 

 

HOT LINE FOR HELP

M962458-0070A

For toll-freeinformation and answers to your questions, call:

DRAIN MOUNTING KIT

 

1 (800) 442-1902

 

 

Weekdays 8:00 a.m. to 6:00 p.m. EST

 

IN CANADA 1-800-387-0369(TORONTO1-905-306-1093)

Weekdays 8:00 a.m. to 7:00 p.m. EST

IN MEXICO 01-800-839-1200

Product names listed herein are trademarks of American Standard Inc.

© AS America,Inc. 2009

M968640 REV . 1 . 1

8